首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Preprocessing of near-infrared spectra to remove unwanted, i.e., non-related spectral variation and selection of informative wavelengths is considered to be a crucial step prior to the construction of a quantitative calibration model. The standard methodology when comparing various preprocessing techniques and selecting different wavelengths is to compare prediction statistics computed with an independent set of data not used to make the actual calibration model. When the errors of reference value are large, no such values are available at all, or only a limited number of samples are available, other methods exist to evaluate the preprocessing method and wavelength selection. In this work we present a new indicator (SE) that only requires blank sample spectra, i.e., spectra of samples that are mixtures of the interfering constituents (everything except the analyte), a pure analyte spectrum, or alternatively, a sample spectrum where the analyte is present. The indicator is based on computing the net analyte signal of the analyte and the total error, i.e., instrumental noise and bias. By comparing the indicator values when different preprocessing techniques and wavelength selections are applied to the spectra, the optimal preprocessing technique and the optimal wavelength selection can be determined without knowledge of reference values, i.e., it minimizes the non-related spectral variation. The SE indicator is compared to two other indicators that also use net analyte signal computations. To demonstrate the feasibility of the SE indicator, two near-infrared spectral data sets from the pharmaceutical industry were used, i.e., diffuse reflectance spectra of powder samples and transmission spectra of tablets. Especially in pharmaceutical spectroscopic applications, it is expected beforehand that the non-related spectral variation is rather large and it is important to remove it. The indicator gave excellent results with respect to wavelength selection and optimal preprocessing. The SE indicator performs better than the two other indicators, and it is also applicable to other situations where the Beer-Lambert law is valid.  相似文献   

2.
Wilson SR  Forgan BW 《Applied optics》1995,34(24):5475-5484
A technique for calibrating spectral radiometers measuring global (2π sr) irradiance using solar irradiance at the top of the atmosphere as the absolute irradiance reference is reported. In addition to providing a calibration at all measured wavelengths, the technique provides a direct measure of the angular response of the radiometer. For instruments that can be used to measure the ultraviolet-B region, the calibration also provides an estimate of the ozone column amount.  相似文献   

3.
A fundamental limitation to the use of single-point absorbance detection for capillary electrophoresis is irradiance, since it is not possible to create an image at the detection point on capillary that is brighter than the light source. This limitation may be overcome by illuminating a length of the capillary using a fiber-optic bundle and using a charge coupled device (CCD) camera that can image the full length of the illuminated zone. The present paper describes design and development of a CCD detector for UV absorbance that can be used in both multiwavelength and single-wavelength modes. The CCD camera images analyte peaks in the capillary dimension, together with wavelength-resolved absorbance in the dimension perpendicular to the capillary. Successive snapshots of the peaks are added together, after appropriate correction for time-dependent peak displacement, without sacrificing spatial resolution. Measured baseline rms noise values at 200 nm are 34 μAU using a holographic grating in multiwavelength mode and 8 μAU with the addition of a band-pass filter. Both values are in excellent agreement with calculations of limiting shot noise. Performance in multiwavelength mode is constrained by the 470-ms readout time of the CCD used, which sets a maximum duty cycle of 2.3%. Noise contributions from source intensity fluctuations are reduced by using a portion of the CCD image to provide a baseline reference signal. With 4-hydroxybenzoate as test analyte, the linear dynamic range in multiwavelength mode is shown to be between 3 and 4 orders of magnitude. High-quality spectra of 2-, 3-, and 4-methylbenzoates are obtained on capillary and used in deconvolution of closely migrating peaks of the 2- and 3-isomers.  相似文献   

4.
Earthshine spectra measured by the nadir-viewing Global Ozone Monitoring Experiment (GOME) spectrometer aboard the second European Remote Sensing (ERS-2) Satellite in the range of 240-790 nm are widely used for the retrieval of concentrations and vertical profiles of atmospheric trace gases. For the near-real-time delivery of ozone columns and profiles at the Royal Netherlands Meterological Institute, a tailor-made wavelength calibration method was developed. The method use a high-resolution (0.01-nm) solar spectrum as the reference spectrum and applies both a shift and a squeeze to the wavelengths in selected windows to find the optimal wavelength grid per window. This method provides a calibration accuracy of 0.002 nm below and 0.001 nm above 290 nm. The new wavelength calibration method can be used on any wavelength window, for example, to improve the calibration of spectra from the GOME Data Processor. A software package, GomeCal, which performs this recalibration, along with an improved polarization and radiometric correction, has been made and has been released via the World Wide Web. The method can be used for any high-resolution (ir)radiance spectrometer, such as the satellite instruments SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Cartography), Ozone Monitoring Instrument, and GOME-2.  相似文献   

5.
利用光谱相位还原直接电场重建法对飞秒脉冲激光时域波形进行重建,分析了光谱测量波长示值误差和光谱辐照度示值误差对于飞秒脉冲光谱测量的影响。使用低压汞灯对光谱仪波长校准,根据校准结果,对测量光谱蓝移和红移,通过数值模拟研究波长示值误差对重建脉冲波形的影响;利用光谱辐射照度标准装置对光谱仪光谱辐照度校准,通过增加白噪声模拟分析和各种常用反射片实验测量研究光谱辐照度示值误差对重建脉冲波形的影响。结果表明,光谱测量波长示值误差和光谱辐照度示值误差对于飞秒脉冲光谱测量的相对标准差在1%之内。  相似文献   

6.
Kindel BC  Qu Z  Goetz AF 《Applied optics》2001,40(21):3483-3494
A radiometrically stable, commercially available spectroradiometer was used in conjunction with a simple, custom-designed telescope to make spectrally continuous measurements of solar spectral transmittance and directly transmitted solar spectral irradiance. The wavelength range of the instrument is 350-2500 nm and the resolution is 3-11.7 nm. Laboratory radiometric calibrations show the instrument to be stable to better than 1.0% over a nine-month period. The instrument and telescope are highly portable, can be set up in a matter of minutes, and can be operated by one person. A method of absolute radiometric calibration that can be tied to published top-of-the-atmosphere (TOA) solar spectra in valid Langley channels as well as regions of strong molecular absorption is also presented. High-altitude Langley plot calibration experiments indicate that this technique is limited ultimately by the current uncertainties in the TOA solar spectra, approximately 2-3%. Example comparisons of measured and modtran-modeled direct solar irradiance show that the model can be parameterized to agree with measurements over the large majority of the wavelength range to the 3% level for the two example cases shown. Side-by-side comparisons with a filter-based solar radiometer are in excellent agreement, with a mean absolute difference of tau = 0.0036 for eight overlapping wavelengths over three experiment days.  相似文献   

7.
Uncertainties in the NIST spectral standards for detectors and sources in the visible wavelength range are propagated from the high accuracy cryogenic radiometer measurements, taking correlations into account at every stage. Partial correlations between spectral values at different wavelengths, important for subsequent radiometric calculations, are estimated. Uncertainty propagation through fitting and through transfer spectral measurements is described in detail. Detector uncertainties are propagated through the spectral comparator facility for external calibrations and for internal photometric quantities. Uncertainties in spectral irradiance are derived for the detector-based temperature determination, then propagated through working standards to calibrated artifacts. Spectral irradiance calibrations are generally provided at a limited number of wavelengths. Interpolation, rather than fitting, is recommended for the interpolation of NIST-provided spectral irradiance values.  相似文献   

8.
A flat-field extreme ultraviolet (EUV) spectrometer with a nominal 2400 grooves/mm aberration-corrected ruled grating has been developed to analyze the emission spectrum in the wavelength range of 10 to 130 A from large helical device (LHD) plasmas. Spectral properties such as resolution, sensitivity, contribution of higher-order light, and background stray light have been studied using emission spectra mainly from intrinsic impurities, e.g., C and Fe. It is found that the spectrometer well resolves closely existing spectral lines of highly ionized medium- and high-Z impurities even in a very short wavelength range such as 10 to 20 A. As a result, it allows one to study the charge state distribution of elements in high-temperature fusion plasma. The ruled grating was then replaced by a laminar type holographic grating for the comparative study. The spectral resolution for the ruled grating (Dlambda approximately 0.08 A at 33.73 A) is clearly better than the holographic grating (Dlambda approximately 0.13 A at 33.73 A). Both gratings well suppress the higher-order light, e.g., the second-order light is only less than 11% of the first-order light for C vi(33.73 A). Relative sensitivity calibration with the wavelength has been done using bremsstrahlung continuum from the LHD plasmas. Absolute intensity calibration has been done by comparing the spectral intensities directly with the absolutely calibrated 1200 grooves/mm EUV spectrometer in the overlapping range of 90-120 A due to the absence of a good branching pair in 10-130 A. As a typical result on the present spectrometer well-resolved n=2-3 full transition arrays from Ne- to Li-like ions are measured for Fe and Ti and wavelengths of the spectral array are tabulated for each charge state. Spectroscopic comparison is also made between the 1200 grooves/mm and 2400 grooves/mm gratings in a range of 50-130 A.  相似文献   

9.
Bais AF 《Applied optics》1997,36(21):5199-5204
A methodology for the absolute calibration of spectral measurements of direct solar ultraviolet radiation, performed with a Brewer spectrophotometer is presented. The method uses absolute measurements of global and diffuse solar irradiance obtained practically simultaneously at each wavelength with the direct-Sun component. On the basis of this calibration, direct-Sun spectra, measured over a wide range of solar zenith angles at a high altitude site, were used to determine the extraterrestrial solar spectrum by applying the Langley extrapolation method. Finally this spectrum is compared with a solar spectrum derived from the airborne tunable laser absorption spectrometer 3 Space Shuttle mission, showing an agreement of better than +/-3%.  相似文献   

10.
Hu Y  Zeng L 《Applied optics》2007,46(28):7018-7025
A practical grating mosaic method is proposed based on quantitative image processing of three far-field diffraction intensity patterns in two wavelengths. This method aims at making a perfect mosaic of two planar gratings that can substitute for a single and larger grating without introducing wavefront aberration at any wavelength. The zeroth-order and first-order far-field patterns of one wavelength are analyzed for separating and eliminating the angular mosaic errors. The first-order far-field patterns of two wavelengths are applied for separation of the lateral and longitudinal phase errors. Then the three patterns are considered together to enlarge the target range of coarse adjustment required for further fine adjustment in longitudinal position. Experimentally, angular and positional detection sensitivities of less than 6 microrad and 14 nm were achieved, respectively, and the periodicity in positional adjustment was checked, which departed less than 1.8% from the theoretical period. The performance of the perfect mosaic grating was diagnosed with the far-field diffraction intensity pattern in a third wavelength, and the necessity for a perfect mosaic was verified.  相似文献   

11.
A novel procedure is proposed as a method to characterize the chemical basis of selectivity for multivariate calibration models. This procedure involves submitting pure component spectra of both the target analyte and suspected interferences to the calibration model in question. The resulting model output is analyzed and interpreted in terms of the relative contribution of each component to the predicted analyte concentration. The utility of this method is illustrated by an analysis of calibration models for glucose, sucrose, and maltose. Near-infrared spectra are collected over the 5000-4000-cm(-)(1) spectral range for a set of ternary mixtures of these sugars. Partial least-squares (PLS) calibration models are generated for each component, and these models provide selective responses for the targeted analytes with standard errors of prediction ranging from 0.2 to 0.7 mM over the concentration range of 0.5-50 mM. The concept of the proposed pure component selectivity analysis is illustrated with these models. Results indicate that the net analyte signal is solely responsible for the selectivity of each individual model. Despite strong spectral overlap for these simple carbohydrates, calibration models based on the PLS algorithm provide sufficient selectivity to distinguish these commonly used sugars. The proposed procedure demonstrates conclusively that no component of the sucrose or maltose spectrum contributes to the selective measurement of glucose. Analogous conclusions are possible for the sucrose and maltose calibration models.  相似文献   

12.
This report describes the details of a recently upgraded spectral irradiance measurement facility in optical radiation standards at National Physical Laboratory, India. This facility provides the calibration of spectral irradiance in the wavelength range 280 nm – 2500 nm. PTB, Braunschweig, Germany calibrated five numbers of 1000 W quartz halogen lamps, which are used as reference standards for spectral irradiance scale. In addition to providing the details of instruments, the procedure of calibration and evaluation of uncertainties is also described. For checking the fidelity, repeatability and reproducibility of the upgraded system, calibration of one of the PTB calibrated lamps, was done against the other four PTB calibrated lamps. These measurements not only provide confidence on the upgraded system but also verify the retention of the PTB certificate values after a lapse of two years after their calibration.  相似文献   

13.
基于线阵 CCD 的全息光栅位移传感器   总被引:5,自引:2,他引:3  
目的:提出了一种新型的基于全息光栅的CCD位移传感器。方法:利用CCD分辨率高,像素均匀等特点,对干涉条纹的移动进行精确定位,利用全息光栅在测量过程中又具有不受光源波长的影响,适用光谱范围宽等特点,实现位移的自动精确测量。结果:系统能够对位移实现自动精确测量。结论:该系统具有一定的实用价值及应用前景。  相似文献   

14.
The ex vivo removal of urea during hemodialysis treatments is monitored in real time with a noninvasive near-infrared spectrometer. The spectrometer uses a temperature-controlled acousto optical tunable filter (AOFT) in conjunction with a thermoelectrically cooled extended wavelength InGaAs detector to provide spectra with a 20 cm(-1) resolution over the combination region (4000-5000 cm(-1)) of the near-infrared spectrum. Spectra are signal averaged over 15 seconds to provide root mean square noise levels of 24 micro-absorbance units for 100% lines generated over the 4600-4500 cm(-1) spectral range. Combination spectra of the spent dialysate stream are collected in real-time as a portion of this stream passes through a sample holder constructed from a 1.1 mm inner diameter tube of Teflon. Real-time spectra are collected during 17 individual dialysis sessions over a period of 10 days. Reference samples were extracted periodically during each session to generate 87 unique samples with corresponding reference concentrations for urea, glucose, lactate, and creatinine. A series of calibration models are generated for urea by using the partial least squares (PLS) algorithm and each model is optimized in terms of number of factors and spectral range. The best calibration model gives a standard error of prediction (SEP) of 0.30 mM based on a random splitting of spectra generated from all 87 reference samples collected across the 17 dialysis sessions. PLS models were also developed by using spectra collected in early sessions to predict urea concentrations from spectra collected in subsequent sessions. SEP values for these prospective models range from 0.37 mM to 0.52 mM. Although higher than when spectra are pooled from all 17 sessions, these prospective SEP values are acceptable for monitoring the hemodialysis process. Selectivity for urea is demonstrated and the selectivity properties of the PLS calibration models are characterized with a pure component selectivity analysis.  相似文献   

15.
Strasser TA  Gupta MC 《Applied optics》1994,33(15):3220-3226
Experimental results are presented that show that diffraction off a surface-relief reflection grating can be used to extend the FWHM input coupling efficiency versus the coupled-light wavelength of a grating coupler from 0.7 to 17 nm. Use of a surface-relief reflection grating allows high diffraction efficiency over a wide wavelength range. Dispersion-matching calculations are included that illustrate that for certain output coupling applications the FWHM can be extended to 33 am. Analysis shows that for inputcoupling applications the lateral beam shift resulting from angular dispersion may be the limiting factor for wavelength compensation.  相似文献   

16.
The present work uses fluorescein as the model fluorophore and points out critical steps in the use of MESF (Molecules of Equivalent Soluble Fluorophores) values for quantitative flow cytometric measurements. It has been found that emission spectrum matching between a reference solution and an analyte and normalization by the corresponding extinction coefficient are required for quantifying fluorescence signals using flow cytometers. Because of the use of fluorescein, the pH value of the medium is also critical for accurate MESF assignments. Given that the emission spectrum shapes of microbead suspensions and stained biological cells are not significantly different, the percentage of error due to spectrum mismatch is estimated. We have also found that the emission spectrum of a microbead with a seven-methylene linker between the fluorescein and the bead surface (bead7) provides the best match with the spectra from biological cells. Therefore, bead7 is potentially a better calibration standard for flow cytometers than the existing one that is commercially available and used in the present study.  相似文献   

17.
Holy JA 《Applied spectroscopy》2004,58(10):1219-1227
The grating equation is used to generate quadratic calibration equations for multichannel detectors with perpendicular and tilted focal planes. The quadratic coefficients are not independent and contain terms that are used to solve for spectrometer-detector parameters. The parameters can be calculated from a quadratic fit at one spectrometer position, but more accurate values can be obtained from quadratic fits at two spectrometer positions. The calculations show that the detector focal plane is tilted by about two degrees. Once values for the spectrometer-detector parameters are obtained from calibrations using at least three lines at one or two spectrometer positions, only one calibration line at any spectrometer position is required to obtain accuracies on the order of 0.1 cm(-1) over a several thousand wavenumber range. The main cause of spectrometer drift is a change in the diffraction angle and/or the spectrometer included angle. This drift is almost totally compensated by the one-line calibration, which adjusts the diffraction angle. A neon pen lamp is used to generate the calibration spectra. Using standard air wavelengths compared to true wavelengths can produce calibration errors of 0.1 to 0.6 cm(-1); the magnitude depends on local conditions and how the laser wavelength is treated.  相似文献   

18.
Rowe MA  Swann WC  Gilbert SL 《Applied optics》2004,43(17):3530-3534
We present a wavelength calibration reference based on interleaved, sampled fiber Bragg gratings stabilized to a molecular absorption line. Such a hybrid reference can provide multiple stable calibration peaks over a wide range of wavelengths. We demonstrate a wavelength reference that has at least 20 peaks suitable for use as calibration references in each of three wavelength regions: 850, 1300, and 1550 nm. We monitored the stability of a 1300-nm reflection peak and found that the standard deviation of the peak wavelength was 0.7 pm over a 70-day period.  相似文献   

19.
A novel instrumental method for angle and wavelength modulated surface plasmon resonance (SPR) spectroscopy is applied to the problem of spectral selectivity in SPR experiments. For transparent analytes, SPR reflectivity data are reduced to a two-dimensional (2D) spectrum of resonance wavelength versus incident angle, lambdaSPR(theta). This spectrum encodes the refractive index (RI) dispersion of the analyte and illustrates the increased SPR spectral shift per unit RI change at longer wavelengths (lower angle). For the absorbing analyte magnesium phthalocyanine (MgPc), the 2D data reduction method is complicated by the way the SPR and MgPc-based spectral peaks mix. Fresnel reflectivity models support experimental observations of spectral branching and qualitative fingerprints in the form of branched spectra, and difference reflectivity deltaR(lambda, theta) contour plots are presented.  相似文献   

20.
Goray LI  Seely JF 《Applied optics》2002,41(7):1434-1445
The near-normal-incidence efficiencies of a 2400-groove/mm holographic master grating, a replica grating, and a multilayer grating are modeled in the soft-x-ray-extreme-ultraviolet (EUV) regions and are compared with efficiencies that are measured with synchrotron radiation. The efficiencies are calculated by the computer program PCGrate, which is based on a rigorous modified integral method. The theory of our integral method is described both for monolayer and multilayer gratings designated for the soft-x-ray-EUV-wavelength range. The calculations account for the groove profile as determined from atomic force microscopy with a depth scaling in the case of the multilayer grating and an average random microroughness (0.7 nm) for the short wavelengths. The refractive indices of the grating substrate and coatings have been taken from different sources because of the wide range of the wavelengths (4.5-50 nm). The measured peak absolute efficiency of 10.4% in the second diffraction order at a wavelength of 11.4 nm is achieved for the multilayer grating and is in good agreement with a computed value of approximately 11.5%. Rigorous modeling of the efficiencies of three similar gratings is in good overall agreement with the measured efficiency over a wide wavelength region. Additional calculations have indicated that relatively high normal incidence efficiency (of at least several percent) and large angular dispersion in the higher orders can be achieved in the 4.5-10.5-nm range by application of various multilayer coatings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号