首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Imaging and characterization of engineered nanoparticles (ENPs) in water, soils, sediment and food matrices is very important for research into the risks of ENPs to consumers and the environment. However, these analyses pose a significant challenge as most existing techniques require some form of sample manipulation prior to imaging and characterization, which can result in changes in the ENPs in a sample and in the introduction of analytical artefacts. This study therefore explored the application of a newly designed instrument, the atmospheric scanning electron microscope (ASEM), which allows the direct characterization of ENPs in liquid matrices and which therefore overcomes some of the limitations associated with existing imaging methods. ASEM was used to characterize the size distribution of a range of ENPs in a selection of environmental and food matrices, including supernatant of natural sediment, test medium used in ecotoxicology studies, bovine serum albumin and tomato soup under atmospheric conditions. The obtained imaging results were compared to results obtained using conventional imaging by transmission electron microscope (TEM) and SEM as well as to size distribution data derived from nanoparticle tracking analysis (NTA). ASEM analysis was found to be a complementary technique to existing methods that is able to visualize ENPs in complex liquid matrices and to provide ENP size information without extensive sample preparation. ASEM images can detect ENPs in liquids down to 30 nm and to a level of 1 mg L?1 (9×108 particles mL?1, 50 nm Au ENPs). The results indicate ASEM is a highly complementary method to existing approaches for analyzing ENPs in complex media and that its use will allow those studying to study ENP behavior in situ, something that is currently extremely challenging to do.  相似文献   

2.
Exocrine glands, e.g., salivary and pancreatic glands, play an important role in digestive enzyme secretion, while endocrine glands, e.g., pancreatic islets, secrete hormones that regulate blood glucose levels. The dysfunction of these secretory organs immediately leads to various diseases, such as diabetes or Sjögren's syndrome, by poorly understood mechanisms. Gland‐related diseases have been studied by optical microscopy (OM), and at higher resolution by transmission electron microscopy (TEM) of Epon embedded samples, which necessitates hydrophobic sample pretreatment. Here, we report the direct observation of tissue in aqueous solution by atmospheric scanning electron microscopy (ASEM). Salivary glands, lacrimal glands, and pancreas were fixed, sectioned into slabs, stained with phosphotungstic acid (PTA), and inspected in radical scavenger d ‐glucose solution from below by an inverted scanning electron microscopy (SEM), guided by optical microscopy from above to target the tissue substructures. A 2‐ to 3‐µm specimen thickness was visualized by the SEM. In secretory cells, cytoplasmic vesicles and other organelles were clearly imaged at high resolution, and the former could be classified according to the degree of PTA staining. In islets of Langerhans, the microvascular system used as an outlet by the secretory cells was also clearly observed. Microvascular system is also critically involved in the onset of diabetic complications and was clearly visible in subcutaneous tissue imaged by ASEM. The results suggest the use of in‐solution ASEM for histology and to study vesicle secretion systems. Further, the high‐throughput of ASEM makes it a potential tool for the diagnosis of exocrine and endocrine‐related diseases.  相似文献   

3.
Both image quality and the accuracy of x-ray analysis invariable pressure scanning electron microscopes (VPSEMs) are often limited by the spread of the primary electronbeam due to scattering by the introduced gas. The degree of electron scattering depends partly on the atomic number Z of the gas, and the use of a low Z gas such as helium should reduce beam scattering and enhance image quality. Using anuncoated test sample of copper iron sulphide inclusions in calcium fluorite, we show that the reduction in beam scatter produced by helium is more than sufficient to compensate for its reduced efficiency of charge neutralisation. The relative insensitivity to pressure of x-ray measurements in a helium atmosphere compared with air, and the consequent ability to work over a wider range of working distances, pressures, and voltages, make helium potentially the gas of choice for many routine VPSEM applications.  相似文献   

4.
We examined CD133 distribution in a human hepatoblastoma cell line (HuH‐6 clone 5). We directly observed the cultured cells on a pressure‐resistant thin film (silicon nitride thin film) in a buffer solution by using the newly developed atmospheric scanning electron microscope (ASEM), which features an open sample dish with a silicon nitride thin film window at its base, through which the scanning electron microscope beam scans samples in solution, from below. The ASEM enabled observation of the ventral cell surface, which could not be observed using standard SEM. However, observation of the dorsal cell surface was difficult with the ASEM. Therefore, we developed a new method to observe the dorsal side of cells by using Aclar® plastic film. In this method, cells are cultured on Aclar plastic film and the dorsal side of cells is in contact with the thin silicon nitride film of the ASEM dish. A preliminary study using the ASEM showed that CD133 was mainly localized in membrane ruffles in the peripheral regions of the cell. Standard transmission electron microscopy and scanning electron microscopy revealed that CD133 was preferentially concentrated in a complex structure comprising filopodia and the leading edge of lamellipodia. We also observed co‐localization of CD133 with F‐actin. An antibody against CD133 decreased cell migration. Methyl‐β‐cyclodextrin treatment decreased cell adhesion as well as lamellipodium and filopodium formation. A decrease in the cholesterol level may perturb CD133 membrane localization. The results suggest that CD133 membrane localization plays a role in tumor cell adhesion and migration. Microsc. Res. Tech. 76:844–852, 2013. © 2013 Wiley Periodicals, Inc.  相似文献   

5.
6.
Mathews RG  Donald AM 《Scanning》2002,24(2):75-85
Environmental scanning electron microscopy (ESEM) is a technique capable of imaging volatile and/or insulating samples in their natural state, without prior specimen preparation. It is thus a powerful potential tool for the study of the structure and dynamics of emulsions and other complex liquid systems, at a resolution greater than that obtainable by conventional optical microscopy. We present images of a variety of liquid systems containing micron-scale and smaller features. The morphology of these systems may be clearly discerned. The contrast observed between the liquid phases was consistent with the model proposed by Stokes et al. (1998). The limits of resolution were determined by sample motion and by beam damage effects; under optimum conditions, resolution of a few tens of nanometers was obtained. This compares favourably with conventional and confocal optical microscopy. In some samples, thin films (solid or liquid) could be observed at the liquid/gas interface. Some of these films were so thin that they did not completely obscure the underlying structure of the bulk sample.  相似文献   

7.
We have developed a method for observing transverse swelling of cellulosic fibres in the environmental scanning electron microscope (ESEM). The presence of liquid water in the ESEM specimen chamber allows the observation of in situ hydration without the need for coating, freezing, or drying of the sample. For reproducibility of the hydration and dehydration process, specialised mounting techniques are required and control of the conditions for condensation and evaporation of liquid water is necessary. The sensitivity of these cellulosic materials to the electron beam was investigated, showing that some damage mechanisms are enhanced by the continual presence of water vapour in the chamber. A discussion is presented of the effect of various experimental parameters on the extent and time of onset of the damage, and we outline steps to maximise the amount of useful experimental time for these fibres.  相似文献   

8.
Griffin BJ 《Scanning》2000,22(4):234-242
An electron-based technique for the imaging of crystal defect distribution such as material growth histories in non- and poorly conductive materials has been identified in the variable pressure or environmental scanning electron microscope. Variations in lattice coherence at the meso-scale can be imaged in suitable materials. Termed charge contrast imaging (CCI), the technique provides images that correlate exactly with emitted light or cathodoluminescence in suitable materials. This correlation links cathodoluminescence and an electron emission. The specific operating conditions for observation of these images reflect a complex interaction between the electron beam, the positive ions generated by electron-gas interactions in the chamber, a biased detector, and the sample. The net result appears to be the suppression of all but very near surface electron emission from the sample, probably from of the order of a few nanometres. Consequently, CCI are also sensitive to very low levels of surface contaminants. Successful imaging of internal structures in a diverse range of materials indicate that the technique will become an important research tool.  相似文献   

9.
The term “etching,” in electron microscopy, refers to the removal of specimen surface layers and includes chemical, electrolytic, and ion-beam methods. The ion-beam etching process is used to remove layers of a target material by bombarding it with ionized gas molecules. Recently, the method has been applied to the field of biological specimens; however, the practical procedures for such organic materials have not been developed. In the present study, we used an apparatus in which a beam of argon ions is collimated and focused by electrostatic lenses onto an appropriate target. We demonstrated the optimum conditions to observe biological specimens that were treated with osmium tetroxide and tannic acid. The specimens were examined uncoated at low accelerating voltage using a field emission scanning electron microscope. According to our experiments, when a biological specimen was observed under high-resolution conditions at over 50,000x magnification, the optimum condition of ion-beam etching consisted of an accelerating voltage of E = 1 keV and an ion-beam dose of It = 360 ~ 400 μA. min, depending on parts of the specimens. In order to decrease overetching, we had to choose factors such as E = 1 ~ 2 keV and It = 500 μA. min.  相似文献   

10.
We demonstrate that the gas-amplified secondary electron signal obtained in the environmental scanning electron microscope has both desired and spurious components. In order to isolate the contributions of backscattered and secondary electrons, two sets of samples were examined. One sample consisted of a pair of materials having similar secondary emission coefficients but different backscatter coefficients, while the other sample had a pair with similar backscatter but different secondary emission coefficients. Our results show how the contribution of the two electron signals varies according to the pressure of the amplifying gas. Backscatter contributions, as well as background due to gas ionization from the primary beam, become significant at higher pressure. Furthermore, we demonstrate that the relative amplification efficiencies of various electron signals are dependent upon the chemistry of the gas.  相似文献   

11.
Water plays a critical role on the performance, stability and lifetime of proton exchange membrane fuel cells(PEMFCs). The addition of poly tetrafluoroethylene(PTFE) to the gas diffusion layer, especially, the cathode side, would optimize the transportation of water, electron and gas and thus improve the performance of the fuel cell. But until now, the studies about directly applying the PTFE to the catalyst layer are rarely reported. In this paper, the membrane electrode is fabricated by using directly coating catalyst to the membrane method(CCM) and applying PTFE directly to the cathode electrode catalyst layer. The performance of the single cell is determined by polarization curves and durability tests. Electrochemical impedance spectroscopy(EIS) and scanning electron microscopy(SEM) techniques are used to characterize the electrochemical properties of PEMFC. Also the performance of a 10-cells stack is detected. Combining the performance and the physical-chemistry characterization of PEMFC shows that addition of appropriate content of PTFE to the electrode enhances the performance of the fuel cell, which may be due to the improved water management. Addition of appropriate content of PTFE enhances the interaction between the membrane and the catalyst layer, and bigger pores and highly textured structure form in the MEA, which favors the oxygen mass transfer and protons transfer in the fuel cell. While superfluous addition of PTFE covers the surface of catalysts and hindered the contact of catalyst with Nafion, which leads to the reduction of electrochemical active area and the decay of the fuel cell performance. The proposed research would optimize the water management of the fuel cell and thus improve the performance of the fuel cell.  相似文献   

12.
With increasing interest in nanometer scale studies, a common research issue is the need to use different analytical systems with a universal substrate to relocate objects on the nanometer scale. Our paper addresses this need. Using the delicate milling capability of a focused ion beam (FIB) system, a region of interest (ROI) on a sample is labelled via a milled reference grid. FIB technology allows for milling and deposition of material at the sub 20-nm level, in a similar user environment as a standard scanning electron microscope (SEM). Presently commercially available transmission electron microscope (TEM) grids have spacings on the order 100 μm on average; this technique can extend this dimension down to the submicrometre level. With a grid on the order of a few micrometres optical, FIBs, TEMs, scanning electron microscopes (SEMs), and atomic force microscopes (AFM) are able to image the ROI, without special chemical processes or conductive coatings required. To demonstrate, Au nanoparticles of ∼ 25 nm in size were placed on a commercial Formvar®- and carbon-coated TEM grid and later milled with a grid pattern. Demonstration of this technique is also extended to bulk glass substrates for the purpose of sample location. This process is explained and demonstrated using all of the aforementioned analytical techniques.  相似文献   

13.
Toth M  Phillips MR 《Scanning》2000,22(6):370-379
Generation of contrast in images obtained using the environmental scanning electron microscope (ESEM) is explained by interpretation of images acquired using the gaseous secondary electron detector (GSED), ion current, and the Everhart-Thornley detector. We present a previously unreported contrast component in GSED and ion current images attributed to signal induction by changes in the concentration of positive ions in the ESEM chamber during image acquisition. Changes in positive ion concentration are caused by changes in electron emission from the sample during image acquisition and by a discrepancy between the drift velocities of negative and positive charge carriers in the imaging gas. The proposed signal generation mechanism is used to explain contrast reversal in images produced using the GSED and ion current signals and accounts for discrepancies in contrast observed, under some conditions, in these types of images. Combined with existing models of signal generation in the ESEM, the proposed model provides a basis for correct interpretation of ESEM images.  相似文献   

14.
Vladár AE  Radi Z  Postek MT  Joy DC 《Scanning》2006,28(3):133-141
Experimental nanotips have shown significant improvement in the resolution performance of a cold field emission scanning electron microscope (SEM). Nanotip electron sources are very sharp electron emitter tips used as a replacement for the conventional tungsten field emission (FE) electron sources. Nanotips offer higher brightness and smaller electron source size. An electron microscope equipped with a nanotip electron gun can provide images with higher spatial resolution and with better signal-to-noise ratio. This could present a considerable advantage over the current SEM electron gun technology if the tips are sufficiently long-lasting and stable for practical use. In this study, an older field-emission critical dimension (CD) SEM was used as an experimental test platform. Substitution of tungsten nanotips for the regular cathodes required modification of the electron gun circuitry and preparation of nanotips that properly fit the electron gun assembly. In addition, this work contains the results of the modeling and theoretical calculation of the electron gun performance for regular and nanotips, the preparation of the SEM including the design and assembly of a measuring system for essential instrument parameters, design and modification of the electron gun control electronics, development of a procedure for tip exchange, and tests of regular emitter, sharp emitter and nanotips. Nanotip fabrication and characterization procedures were also developed. Using a "sharp" tip as an intermediate to the nanotip clearly demonstrated an improvement in the performance of the test SEM. This and the results of the theoretical assessment gave support for the installation of the nanotips as the next step and pointed to potentially even better performance. Images taken with experimental nanotips showed a minimum two-fold improvement in resolution performance than the specification of the test SEM. The stability of the nanotip electron gun was excellent; the tip stayed useful for high-resolution imaging for several hours during many days of tests. The tip lifetime was found to be several months in light use. This paper summarizes the current state of the work and points to future possibilities that will open when electron guns can be designed to take full advantage of the nanotip electron emitters.  相似文献   

15.
Oho E  Miyamoto M 《Scanning》2004,26(5):250-255
A scanning electron microscope (SEM) system equipped with a motor drive specimen stage fully controlled with a personal computer (PC) has been utilized for obtaining ultralow magnification SEM images. This modem motor drive stage works as a mechanical scanning device. To produce ultra-low magnification SEM images, we use a successful combination of the mechanical scanning, electronic scanning, and digital image processing techniques. This new method is extremely labor and time saving for ultra-low magnification and wide-area observation. The option of ultra-low magnification observation (while maintaining the original SEM functions and performance) is important during a scanning electron microscopy session.  相似文献   

16.
James A. Poston 《Scanning》1995,17(5):316-321
Relatively low-cost modifications to standard commercial scanning electron microscopes (SEM) that allow accurate exposure of sample(s) to noncorrosive gases at ambient and high temperatures are outlined. Energy-dispersive spectroscopic analysis of sample(s) exposed to noncorrosive gases at high temperatures is demonstrated. Gas exposure is limited to pressures of less than 10?4 torr (1.33 × 10?2 Pa) as a result of limitations on SEM system operation and SEM safety interlocks. Gases are limited to noncorrosive types as a result of potential damage to system detection devices and internal mechanical parts.  相似文献   

17.
Nanoindentation experiments inside a transmission electron microscope are of much interest to characterize specific phenomena occuring in materials, like for instance dislocation movements or phase transformations. The key points of these experiments are (i) the sample preparation and the optimization of its geometry to obtain reliable results and (ii) the choice of the transmission electron microscope observation mode, which will condition the type of information which can be deduced from the experiment. In this paper, we will focus on these two key points in the case of nanoindentation of zirconia, which is a ceramic material well known to be sensitive to stress because it can undergo a phase transformation. In this case, the information sought is the stress localization at the nanometre scale and in real time. As far as the sample preparation is concerned, one major drawback of nanoindentation inside a transmission electron microscope is indeed a possible bending of the sample occurring during compression, which is detrimental to the experiment interpretation (the stress is not uniaxial anymore). In this paper, several sample preparation techniques have been used and compared to optimize the geometry of the sample to avoid bending. The results obtained on sample preparation can be useful for the preparation of ceramics samples but can also give interesting clues and experimental approaches to optimize the preparation of other kinds of materials. The second part of this paper is devoted to the second key point, which is the determination of the stress localization associated to the deformation phenomena observed by nanoindentation experiments. In this paper, the use of convergent beam electron diffraction has been investigated and this technique could have been successfully coupled to nanoindentation experiments. Coupled nanoindentation experiments and convergent beam electron diffraction analyses have finally been applied to characterize the phase transformation of zirconia.  相似文献   

18.
We analyse the signal formation process for scanning electron microscopic imaging applications on crystalline specimens. In accordance with previous investigations, we find nontrivial effects of incident beam diffraction on the backscattered electron distribution in energy and momentum. Specifically, incident beam diffraction causes angular changes of the backscattered electron distribution which we identify as the dominant mechanism underlying pseudocolour orientation imaging using multiple, angle‐resolving detectors. Consequently, diffraction effects of the incident beam and their impact on the subsequent coherent and incoherent electron transport need to be taken into account for an in‐depth theoretical modelling of the energy‐ and momentum distribution of electrons backscattered from crystalline sample regions. Our findings have implications for the level of theoretical detail that can be necessary for the interpretation of complex imaging modalities such as electron channelling contrast imaging (ECCI) of defects in crystals. If the solid angle of detection is limited to specific regions of the backscattered electron momentum distribution, the image contrast that is observed in ECCI and similar applications can be strongly affected by incident beam diffraction and topographic effects from the sample surface. As an application, we demonstrate characteristic changes in the resulting images if different properties of the backscattered electron distribution are used for the analysis of a GaN thin film sample containing dislocations.  相似文献   

19.
Eric Doehne 《Scanning》1997,19(2):75-78
Spurious x-ray signals, which previously prevented high-resolution energy-dispersive x-ray analysis (EDS) in the environmental scanning electron microscope (ESEM), can be corrected using a simple method presented here. As the primary electron beam travels through the gas in the ESEM chamber, a significant fraction of the primary electrons is scattered during collisions with gas molecules. These scattered electrons form a broad skirt that surrounds the primary electron beam as it impacts the sample. The correction method assumes that changes in the width of the electron skirt with pressure are less important than changes in the skirt intensity; this method works as follows: The influence of the gas on the overall x-ray data is determined by acquiring EDS spectra at two pressures. Subtracting the two spectra provides us with a difference spectrum which is then used to correct the original data, using extrapolation, back to the x-ray spectrum expected under high-vacuum conditions. Low-noise data are required to resolve small spectral peaks; however, the principle should apply equally to x-ray maps and even to low-magnification images.  相似文献   

20.
The construction of high signal-to-noise, artefact-free secondary electron images in the elevated pressure conditions of an environmental SEM is a nontrivial process. The interactions of information carrying species, as well as probe beam electrons, with the chamber gas are the major reasons for such complications. In this paper, we discuss and review the present understanding of these phenomena. In addition, we outline procedures for assessing the signal-amplifying and charge-neutralising capabilities of an environmental gas. It is only with a knowledge of such parameters and an appreciation of the gas-electron collision processes that one can optimise the microscope's operating parameters. Moreover, such information enables the separation of topographic detail from artefactual features in the detected electron images.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号