1.
Yang M  Li CW  Yang J 《Analytical chemistry》2002,74(16):3991-4001
We have developed a microfluidic device for on-chip monitoring of cellular reactions. The device consists of two primary analytical functions: control of cell transport and immobilization, and dilution of an analyte solution to generate a concentration gradient. In this device, a dam structure in parallel to the fluid flow was constructed for docking and alignment of biological cells, which allows the fragile cells to move in the microfluidic channels and to be immobilized with controllable numbers in desired locations. The cells docked on the parallel dam structure are exposed to minimal stress caused by fluidic pressure. Additionally, a network of microfluidic channels was designed to generate a concentration gradient by controlled fluid distribution and diffusive mixing. An analyte solution could be diluted to different gradients as a function of distance along the dam. We used the ATP-dependent calcium uptake reaction of HL-60 cells as a model for on-chip measurement of the threshold ATP concentration that induces significant intracellular calcium signal. The results have demonstrated the feasibility of using the microchip for real-time monitoring of cellular processes upon treatment of a concentration gradient of a test solution. The integration of cell manipulation and solution manipulation on a microchip allows the measurement of concentration-dependent biological responses within a confined microscale feature.  相似文献   

2.
Integrating multiple analytical processes into microfluidic devices is an important research area required for a variety of microchip-based analyses. A microfluidic system is described that achieves preparative separations by intelligent fraction collection of attomole quantities of sample. The device consists of a main microfluidic channel used to perform electrophoresis, which is interconnected at 90 degrees to two vertically displaced channels via a nanocapillary array membrane. The membrane interconnect contains nanometer-diameter pores that provide fluidic communication between the channels. Sample injection and analyte collection are controlled by application of an electrical bias between the microfluidic channels across the nanocapillary array. After the separation, the automated transfer of the FITC-labeled Arg, Gln, and Gly bands occurs; a fluorescence detector located at the separation/collection channel interconnect is used to generate a triggering signal that initiates suitable voltages to allow near-quantitative transfer of analyte from the separation channel to the second fluidic layer. The ability to achieve such sample manipulations from mass-limited samples enables a variety of postseparation processing events.  相似文献   

3.
4.
Microfluidic gradient-generating device for pharmacological profiling   总被引:1,自引:0,他引:1  
We describe an on-chip microfluidic gradient-generating device that generates concentration gradients spanning nearly 5 orders of magnitude starting from a single concentration. The exiting stream of drugs held at different concentrations remains laminar in a recording chamber and can be presented as 24 discrete solutions to a cell-based sensor. The high-performance characteristics of the device are demonstrated by pharmacological screening of voltage-gated K+ channels (hERG) and ligand-gated GABA(A) receptors using scanning-probe patch-clamp measurements. Multiple data point dose-response curves and IC50 and EC50 values were rapidly obtained, typically in less than 30 min, through its combined functionality of gradient generation and open-volume laminar flow. The device facilitates rapid pharmacological profiling of ion channel and GPCR effectors and enables the acquisition of large numbers of data points with minute sample consumption and handling.  相似文献   

5.
A method for high-throughput 3D self-assembly of 2D photopatterned microstructures using railed microfluidics is presented. Vertical device patterning of heterogeneous materials requires high-level integration using conventional microelectromechanical system (MEMS) technology; however, 3D railed assembly enables easy and fast self-assembly via a fluidic axis-translation process and simple material exchange in microfluidic channels. Individually photopatterned 2D microstructures are axis-translated from in-plane to out-of-plane and fluidically self-assembled, guided by side-rails in microfluidic channels to form a 3D morphology. Since the structures are fabricated in fluidic environments, there are no fixed initial points on the channel substrate allowing fluidic horizontal stacking of erected 2D structures. The guiding mechanism of railed microfluidics enables efficient fluidic handling and deterministic 3D self-assembly of heterogeneous components such as electronic components or polymeric microstructures using only fluidic force.  相似文献   

6.
A 16-channel microfluidic chip with an integrated contact conductivity sensor array is presented. The microfluidic network consisted of 16 separation channels that were hot-embossed into polycarbonate (PC) using a high-precision micromilled metal master. All channels were 40 microm deep and 60 microm wide with an effective separation length of 40 mm. A gold (Au) sensor array was lithographically patterned onto a PC cover plate and assembled to the fluidic chip via thermal bonding in such a way that a pair of Au microelectrodes (60 microm wide with a 5 microm spacing) was incorporated into each of the 16 channels and served as independent contact conductivity detectors. The spacing between the corresponding fluidic reservoirs for each separation channel was set to 9 mm, which allowed for loading samples and buffers to all 40 reservoirs situated on the microchip in only five pipetting steps using an 8-channel pipettor. A printed circuit board (PCB) with platinum (Pt) wires was used to distribute the electrophoresis high-voltage to all reservoirs situated on the fluidic chip. Another PCB was used for collecting the conductivity signals from the patterned Au microelectrodes. The device performance was evaluated using microchip capillary zone electrophoresis (mu-CZE) of amino acid, peptide, and protein mixtures as well as oligonucleotides that were separated via microchip capillary electrochromatography (mu-CEC). The separations were performed with an electric field (E) of 90 V/cm and were completed in less than 4 min in all cases. The conductivity detection was carried out using a bipolar pulse voltage waveform with a pulse amplitude of +/-0.6 V and a frequency of 6.0 kHz. The conductivity sensor array concentration limit of detection (SNR = 3) was determined to be 7.1 microM for alanine. The separation efficiency was found to be 6.4 x 10(4), 2.0 x 10(3), 4.8 x 10(3), and 3.4 x 10(2) plates for the mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins, respectively, with an average channel-to-channel migration time reproducibility of 2.8%. The average resolution obtained for mu-CEC of the oligonucleotides and mu-CZE of the amino acids, peptides, and proteins was 4.6, 1.0, 0.9, and 1.0, respectively. To the best of our knowledge, this report is the first to describe a multichannel microchip electrophoresis device with integrated contact conductivity sensor array.  相似文献   

7.
We present an improved microfluidic design for generating spatial and temporal gradients. The basic functional elements are bifurcated and trifurcated channels used to split flow between two and three channels, respectively. We use bifurcated channels on the exterior of the channel manifold and trifurcated channels in the interior with mixing tees to recombine flows. For N gradient-forming levels, the number of discrete steps in the gradient is 2(N) + 1, allowing a compact gradient-forming structure that is only 1.6 mm long and 0.5 mm wide. Control of the relative sample concentration at the inlets enables generation of gradients with varying slopes and offsets. The small total channel length allows faster switching (only 2.6 s) between gradients of different compositions than did previous designs, allowing complex temporal sequences and reducing total displacement volume and reagent use. The design permits opposing-gradient experiments and generation of complex nonlinear gradients. We fabricated and tested three channel designs with either three or four gradient-forming levels, 20- or 40-microm channel widths, 60- or 120-microm center-to-center channel spacings, and 9 or 17 output steps. These devices produced essentially identical high-quality linear gradients using both pressure-driven and electrokinetic flow.  相似文献   

8.
Microfluidic serial dilution circuit   总被引:1,自引:0,他引:1  
In vitro evolution of RNA molecules requires a method for executing many consecutive serial dilutions. To solve this problem, a microfluidic circuit has been fabricated in a three-layer glass-PDMS-glass device. The 400-nL serial dilution circuit contains five integrated membrane valves: three two-way valves arranged in a loop to drive cyclic mixing of the diluent and carryover, and two bus valves to control fluidic access to the circuit through input and output channels. By varying the valve placement in the circuit, carryover fractions from 0.04 to 0.2 were obtained. Each dilution process, which is composed of a diluent flush cycle followed by a mixing cycle, is carried out with no pipeting, and a sample volume of 400 nL is sufficient for conducting an arbitrary number of serial dilutions. Mixing is precisely controlled by changing the cyclic pumping rate, with a minimum mixing time of 22 s. This microfluidic circuit is generally applicable for integrating automated serial dilution and sample preparation in almost any microfluidic architecture.  相似文献   

9.
Liu X  Abbott NL 《Analytical chemistry》2011,83(8):3033-3041
We report principles for a continuous flow process that can separate solutes based on a driving force for selective transport that is generated by a lateral concentration gradient of a redox-active surfactant across a microfluidic channel. Microfluidic channels fabricated with gold electrodes lining each vertical wall were used to electrochemically generate concentration gradients of the redox-active surfactant 11-ferrocenylundecyl-trimethylammonium bromide (FTMA) in a direction perpendicular to the flow. The interactions of three solutes (a hydrophobic dye, 1-phenylazo-2-naphthylamine (yellow AB), an amphiphilic molecule, 2-(4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-pentanoyl)-1-hexadecanoyl-sn-glycero-3-phosphocholine (BODIPY C(5)-HPC), and an organic salt, 1-methylpyridinium-3-sulfonate (MPS)) with the lateral gradients in surfactant/micelle concentration were shown to drive the formation of solute-specific concentration gradients. Two distinct physical mechanisms were identified to lead to the solute concentration gradients: solubilization of solutes by micelles and differential adsorption of the solutes onto the walls of the microchannels in the presence of the surfactant concentration gradient. These two mechanisms were used to demonstrate delipidation of a mixture of BODIPY C(5)-HPC (lipid) and MPS and purification of BODIPY C(5)-HPC from a mixture of BODIPY C(5)-HPC and yellow AB. Overall, the results of this study demonstrate that lateral concentration gradients of redox-active surfactants formed within microfluidic channels can be used to transport solutes across the microfluidic channels in a solute-dependent manner. The approach employs electrical potentials (<1 V) that are sufficiently small to avoid electrolysis of water, can be performed in solutions having high ionic strength (>0.1M), and offers the basis of continuous processes for the purification or separation of solutes in microscale systems.  相似文献   

10.
Despite multiple orbiter and landed missions to extraterrestrial bodies in the solar system, including Mars and Titan, we still know relatively little about the detailed chemical composition and quantity of organics and biomolecules in those bodies. For chemical analysis on astrobiologically relevant targets such as Mars, Europa, Titan, and Enceladus, instrumentation should be extremely sensitive and capable of analyzing a broad range of organic molecules. Microchip capillary electrophoresis (μCE) with laser-induced fluorescence (LIF) detection provides this required sensitivity and targets a wide range of relevant markers but, to date, has lacked the necessary degree of automation for spaceflight applications. Here we describe a fully integrated microfluidic device capable of performing automated end-to-end analyses of amino acids by μCE with LIF detection. The device integrates an array of pneumatically actuated valves and pumps for autonomous fluidic routing with an electrophoretic channel. Operation of the device, including manipulation of liquids for sample pretreatment and electrophoretic analysis, was performed exclusively via computer control. The device was validated by mixing of laboratory standards and labeling of amino acids with Pacific Blue succinimidyl ester followed by electrophoretic analysis. To our knowledge, this is the first demonstration of completely automated end-to-end μCE analyses on a single, fully integrated microfluidic device.  相似文献   

11.
Ly N  Foley K  Tao N 《Analytical chemistry》2007,79(6):2546-2551
We demonstrate a label-free protein detection and separation technology for real-time monitoring of proteins in micro/nanofluidic channels, confined surface plasmon resonance imaging (confined-SPRi). This was achieved by fabricating ultrathin fluidic channels (500 nm high, 500 microm wide) directly on top of a specialized SPRi sensor surface. In this way, SPRi is uniquely used to detect proteins deep into the fluidic channel while maintaining high lateral accuracy of separated products. The channel fluid and proteins were driven electrokinetically under an external electric field. For this to occur, the metallic SPR sensor (46 nm of Au on 2 nm of Cr) was segmented into an array of squares (each 200 microm x 200 microm in size and spaced 8 microm apart) and coated with 30 nm of CYTOP polymer. In this work, we track label-free protein separation in real time through a simple cross-junction fluidic device with an 8-mm separation channel length under 30 V/cm electric field strength.  相似文献   

12.
Plecis A  Chen Y 《Analytical chemistry》2008,80(10):3736-3742
A microfluidic analogy of the electric Wheatstone Bridge has been developed for electrokinetic study of miscellaneous liquid-solid interfaces. By using an optimized glass-PDMS-glass device technology, microfluidic channels with well-controlled surface properties can be fabricated, forming an "H" shaped fluidic network. After solving a set of linear equations, the electro-osmotic flow rate in the center channel can be deduced from indirect measurement of flow rates in the lateral channels. Experimentally, we demonstrate that the electro-osmotic mobility can be monitored every 30 s with accuracy better than 3% for a large dynamic range of electric fields. The results obtained with a borosilicate glass (D-263) and several standard biological buffers are also shown to illustrate the capability of this high throughput method.  相似文献   

13.
Kinetic rate constants for enzymatic reactions are typically measured with a series of experiments at different substrate concentrations in a well-mixed container. Here we demonstrate a microfluidic technique for measuring Michaelis-Menten rate constants with only a single experiment. Enzyme and substrate are brought together in a coflow microfluidic device, and we establish analytically and numerically that the initial concentration of product scales with the distance x along the channel as x5/2. Measurements of the initial rate of product formation, combined with the quasi-steady rate of product formation further downstream, yield the rate constants. We corroborate the x5/2 scaling result experimentally using the bioluminescent reaction between ATP and luciferase/luciferin as a model system.  相似文献   

14.
Bui MP  Li CA  Han KN  Choo J  Lee EK  Seong GH 《Analytical chemistry》2011,83(5):1603-1608
In this paper, we propose a microfluidic device that is capable of generating a concentration gradient followed by parallel droplet formation within channels with a simple T-junction geometry. Linear concentration gradient profiles can be obtained based on fluid diffusion under laminar flow. Optimized conditions for generating a linear concentration gradient and parallel droplet formation were investigated using fluorescent dye. The concentration gradient profile under diffusive mixing was dominated by the flow rate at sample inlets, while parallel droplet formation was affected by the channel geometry at both the inlet and outlet. The microfluidic device was experimentally characterized using optimal layout and operating conditions selected through a design process. Furthermore, in situ enzyme kinetic measurements of the β-galactosidase-catalyzed hydrolysis of resorufin-β-d-galactopyranoside were performed to demonstrate the application potential of our simple, time-effective, and low sample volume microfluidic device. We expect that, in addition to enzyme kinetics, drug screening and clinical diagnostic tests can be rapidly and accurately performed using this droplet-based microfluidic system.  相似文献   

15.
An electrospray ionization source for integration with microfluidics   总被引:3,自引:0,他引:3  
We have demonstrated a new electrospray ionization (ESI) device incorporating a tip made from a shaped thin film, bonded to a microfluidic channel, and interfaced to a time-of-flight mass spectrometer (TOFMS). A triangular-shaped thin polymer tip was formed by lithography and etching. A microfluidic channel, 20 microm wide and 10 microm deep, was embossed in a cyclo olefin substrate using a silicon master. The triangular tip was aligned with the channel and bonded between the channel plate and a flat plate to create a microfluidic channel with a wicking tip protruding from the end. This structure aided the formation of a stable Taylor cone at the apex of the tip, forming an electrospray ionization source. This source was tested by spraying several solutions for mass spectrometric analysis. Because the components are all made by lithographic approaches with high geometrical fidelity, an integrated array system with multiple channels can be formed with the same method and ease as a single channel. We tested a multichannel system in a multiplexed manner and showed reliable operation with no significant cross contamination between closely spaced channels.  相似文献   

16.
Rapid detection and identification of influenza virus is becoming increasingly important in the face of concerns over an influenza pandemic. A fully integrated and self-contained microfluidic device has been developed to rapidly identify influenza A hemagglutinin and neuraminidase subtypes and sequence portions of both genes. The device consists of a DNA microarray with 12 000 features and a microfluidic cartridge that automates the fluidic handling steps required to carry out a genotyping assay for pathogen identification and sequencing. The fully integrated microfluidic device consists of microfluidic pumps, mixers, valves, fluid channels, reagent storage chambers, and DNA microarray silicon chip. Microarray hybridization and subsequent fluidic handling and reactions were performed in this fully automated and miniature device before fluorescent image scanning of the microarray chip. A micromixing technique based on gas bubbling generated by electrochemical micropumps was developed. Low-cost check valves were implemented in the cartridge to prevent cross talk of the stored reagents. The genotyping results showed that the device identified influenza A hemagglutinin and neuraminidase subtypes and sequenced portions of both genes, demonstrating the potential of integrated microfluidic and microarray technology for multiple virus detection. The device provides a cost-effective solution to eliminate labor-intensive and time-consuming fluidic handling steps and allows the detection and identification of influenza virus in a rapid and automated fashion.  相似文献   

17.
A major challenge to scale up a microfluidic magnetic separator for extracorporeal blood cleansing applications is to overcome low magnetic drag velocity caused by viscous blood components interfering with magnetophoresis. Therefore, there is an unmet need to develop an effective method to position magnetic particles to the area of augmented magnetic flux density gradients while retaining clinically applicable throughput. Here, a magnetophoretic cell separation device, integrated with slanted ridge‐arrays in a microfluidic channel, is reported. The slanted ridges patterned in the microfluidic channels generate spiral flows along the microfluidic channel. The cells bound with magnetic particles follow trajectories of the spiral streamlines and are repeatedly transferred in a transverse direction toward the area adjacent to a ferromagnetic nickel structure, where they are exposed to a highly augmented magnetic force of 7.68 µN that is much greater than the force (0.35 pN) at the side of the channel furthest from the nickel structure. With this approach, 91.68% ± 2.18% of Escherichia coli (E. coli) bound with magnetic nanoparticles are successfully separated from undiluted whole blood at a flow rate of 0.6 mL h?1 in a single microfluidic channel, whereas only 23.98% ± 6.59% of E. coli are depleted in the conventional microfluidic device.  相似文献   

18.
The creation of geometrically complex fluidic devices is a subject of broad fundamental and technological interest. Here, we demonstrate the fabrication of three-dimensional (3D) microvascular networks through direct-write assembly of a fugitive organic ink. This approach yields a pervasive network of smooth cylindrical channels (approximately 10-300 microm) with defined connectivity. Square-spiral towers, isolated within this vascular network, promote fluid mixing through chaotic advection. These vertical towers give rise to dramatic improvements in mixing relative to simple straight (1D) and square-wave (2D) channels while significantly reducing the device planar footprint. We envisage that 3D microvascular networks will provide an enabling platform for a wide array of fluidic-based applications.  相似文献   

19.
We present microfluidic device designs with a two-dimensional planar format and methods to facilitate efficient sample transport along both dimensions. The basic device design consisted of a single channel for the first dimension which orthogonally intersected a high-aspect ratio second-dimension channel. To minimize dispersion of sample moving into and through the sample transfer region, control channels were placed on both sides of the first-dimension channel, and the electrokinetic flow from these control channels was used to confine the sample stream. We used SIMION and COMSOL simulations of the electric fields and fluid flow to guide device design. First, devices with one, two, and four control channels were fabricated and tested, and four control channels provided the most effective sample confinement. The designs were evaluated by measuring the sample stream widths and concentration to width ratios as a function of the electric field strength ratio in the control channels and first-dimension (1D) channel (EC/E1D). Next, both a single open channel and an array of parallel channels were tested for the second dimension, and improved performance was observed for the parallel channel design, with stream widths as narrow as 120 microm. The ease with which fluids could be introduced into both the first and second dimensions was also illustrated. Sample plugs injected into the planar region were confined as effectively as sample streams and were easily routed into the planar region by reconfiguring the applied potentials.  相似文献   

20.
Bowden M  Song L  Walt DR 《Analytical chemistry》2005,77(17):5583-5588
In this paper, DNA hybridization in a microfluidic manifold is performed using fluorescence detection on a fiber-optic microarray. The microfluidic device integrates optics, sample transport, and fluidic interconnects on a single platform. A high-density optical imaging fiber array containing oligonucleotide-labeled microspheres was developed. DNA hybridization was observed at concentrations as low as 10 aM with response times of less than 15 min at a flow rate of 1 microL/min using 50 microL of target DNA samples. The fast response times coupled with the low sample volumes and the use of a high-density, fiber-optic microarray format make this method highly advantageous. This paper describes the initial development, optimization, and integration of the microfluidic platform with imaging fiber arrays.  相似文献   