首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到7条相似文献,搜索用时 0 毫秒
1.
Pulp mill effluent containing toxic chemicals was treated by different advanced oxidation processes (AOPs) consisting of treatments by hydrogen peroxide, Fenton's reagent (H2O2/Fe2+), UV, UV/H2O2, photo-Fenton (UV/H2O2/Fe2+), ozonation and peroxone (ozone/H2O2) in laboratory-scale reactors for color, total organic carbon (TOC) and adsorbable organic halogens (AOX) removals from the pulp mill effluent. Effects of some operating parameters such as the initial pH, oxidant and catalyst concentrations on TOC, color, AOX removals were investigated. Almost every method used resulted in some degree of color removal from the pulp mill effluent. However, the Fenton's reagent utilizing H2O2/Fe2+ resulted in the highest color, TOC and AOX removals under acidic conditions when compared with the other AOPs tested. Approximately, 88% TOC, 85% color and 89% AOX removals were obtained by the Fenton's reagent at pH 5 within 30 min. Photo-Fenton process yielded comparable TOC (85%), color (82%) and AOX (93%) removals within 5 min due to oxidations by UV light in addition to the Fenton's reagent. Fast oxidation reactions by the photo-Fenton treatment makes this approach more favorable as compared to the others used.  相似文献   

2.
As a consequence of the population growth, major efforts have been made by the Egyptian government to construct new industrial areas. Tenth of Ramadan City is one of the most important industrial cities in Egypt. The wastewater generated from various industrial activities was highly contaminated with organic matters as indicated by COD (1750-3323 mg/L), TSS (900-3000 mg/L) and oil and grease (13.2-95.5 mg/L). All overall appraisals of the analytical data from the industrial wastewater indicate that pretreatment is required for all industrial sectors to achieve compliance with the Egyptian Environmental law which requires effective pretreatment of industrial wastewater prior to its discharge into public sewers. Treatability studies via conventional and Fenton processes have been investigated. The efficiency of conventional treatment methods led to 63% COD and 44% color removal by using FeCl(3) as coagulant. Various coagulant aids and powdered activated carbon (PAC) were added to 400mg/L FeCl(3) in order to enhance the removal of color. It was found that polyacrylamide polymer, bentonite and PAC increased the efficiency of the treatments where the color removal increased to 79%, by cationic polymer, 73% by anionic polymer, 84.5% by bentonite and 95% for 0.4 g/L PAC. Fenton process was investigated which under the operating conditions (pH 3.0+/-0.2, Fe(2+) dose=400 mg/L and H(2)O(2)=550 mg/L), color removal up to 100% and more than 90% of COD removal were achieved.  相似文献   

3.
The applicability of Fenton's oxidation to improve the biodegradability of a pharmaceutical wastewater to be treated biologically was investigated. The wastewater was originated from a factory producing a variety of pharmaceutical chemicals. Treatability studies were conducted under laboratory conditions with all chemicals (having COD varying from 900 to 7000 mg/L) produced in the factory in order to determine the operational conditions to utilize in the full-scale treatment plant. Optimum pH was determined as 3.5 and 7.0 for the first (oxidation) and second stage (coagulation) of the Fenton process, respectively. For all chemicals, COD removal efficiency was highest when the molar ratio of H(2)O(2)/Fe(2+) was 150-250. At H(2)O(2)/Fe(2+) ratio of 155, 0.3M H(2)O(2) and 0.002 M Fe(2+), provided 45-65% COD removal. The wastewater treatment plant that employs Fenton oxidation followed by aerobic degradation in sequencing batch reactors (SBR), built after these treatability studies provided an overall COD removal efficiency of 98%, and compliance with the discharge limits. The efficiency of the Fenton's oxidation was around 45-50% and the efficiency in the SBR system which has two reactors each having a volume of 8m(3) and operated with a total cycle time of 1 day, was around 98%, regarding the COD removal.  相似文献   

4.
High-quality industrial processes, characterized by a low fraction of non-conforming items, require paying special attention to the statistical control methods employed since traditional Shewhart's control charts are no longer suitable. In this article, CCC-r charts are considered based on the cumulative count of conforming items inspected until r non-conforming items are observed. However, even though these charts have shown to be useful for high-quality processes, they are characterized by a biased average run length (ARL). In order to help engineers interested in this control methodology to select the best option, a computational study of statistical validation was performed to compare the two most outstanding procedures for the cases r = 2, 3, and 4. The performance was evaluated based on the ARL under control. The application of the CCC-r chart to a real process is shown with data from an automobile parts plant. Finally, analysis and discussion of the results are presented.  相似文献   

5.
The decolorization of C.I. Acid Red 27 (AR27), a monoazo anionic dye, was studied in the ultraviolet radiation (UV) alone and UV plus hydrogen peroxide (UV/H(2)O(2)) processes. The experimental results indicated that the kinetics of both oxidation processes fit well by pseudo-first order kinetics. The reaction rate was sensitive to the operational parameters and increased with increasing H(2)O(2) concentration and light intensity. The reaction orders of H(2)O(2) concentration and light intensity in both processes were obtained with linear regression method. A regression model was developed for pseudo-first order rate constant (k(ap,UV/H(2)O(2))) as a function of the Cconcentration and UV light intensity. (k(ap,UV/H(2)O(2)))=(2 x 10(-4)I(0.75)(0) + k(3)I(1.38)(0)[H(2)O(2)](n)(0))phi(AR27). As a result of two opposing effects of H(2)O(2) concentration at low and high concentrations, n has a value of 0.49 and -0.39 and k(3) has a value of 3 x 10(-4) and 0.1 for the regions of 0 mg l(-1) < [H(2)O(2)](0) < 650 mg l(-1) and 650 mg l(-1) < [H(2)O(2)](0) < 1500 mg l(-1)1, respectively. PhiAR27 is the initial dye concentration correlation index for developing of model for different initial concentrations of AR27. This rate expression can be used for predicting k(ap,UV/H(2)O(2) at different conditions in UV alone and UV/H2O2 processes. The results show that UV alone cannot be an efficient method for decolorization of AR27 in comparison with UV/H(2)O(2) process, therefore the first term of the model can be neglected.  相似文献   

6.
The zero-valent iron (ZVI) reduction succeeds for decolorization, while UV/H(2)O(2) oxidation process results into mineralization, so that this study proposed an integrated technique by reduction coupling with oxidation process in order to acquire simultaneously complete both decolorization and mineralization of C.I. Acid Black 24. From the experimental data, the zero-valent iron addition alone can decolorize the dye wastewater yet it demanded longer time than ZVI coupled with UV/H(2)O(2) processes (Red-Ox). Moreover, it resulted into only about 30% removal of the total organic carbon (TOC), which was capable to be effectively mineralized by UV/H(2)O(2) process. The proposed sequential ZVI-UV/H(2)O(2) integration system cannot only effectively remove color and TOC in AB 24 wastewater simultaneously but also save irradiation power and time demand. Furthermore, the decolorization rate constants were about 3.77-4.0 times magnitude comparing with that by UV/H(2)O(2) process alone.  相似文献   

7.
The paper presents some results of a case study on “Demonstration of statistical approaches to identify the component's ageing by operational data analysis”, which was done in the frame of the EC JRC Ageing PSA Network. Several techniques: visual evaluation, nonparametric and parametric hypothesis tests, were proposed and applied in order to demonstrate the capacity, advantages and limitations of statistical approaches to identify the component's ageing by operational data analysis. Engineering considerations are out of the scope of the present study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号