首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Direct mass spectrometric quantification of peptides and proteins is compromised by the wide variabilities in ionization efficiency which are hallmarks of both the MALDI and ESI ionization techniques. We describe here the implementation of a fluorescence detection system for measurement of the UV-excited intrinsic fluorescence (UV-IF) from peptides and proteins just prior to their exit and electrospray ionization from an ESI capillary. The fluorescence signal provides a quantifiable measure of the amount of protein or peptide present, while direct or tandem mass spectrometric analysis (MS/MS) on the ESI-generated ions provides information on identity. We fabricated an inexpensive, modular fluorescence excitation and detection device utilizing an ultraviolet light-emitting diode for excitation in a ~300 nL fluorescence detection cell integrated into the fused-silica separation column. The fluorescence signal is linear over 3 orders of magnitude with on-column limits of detection in the low femtomole range. Chromatographically separated intact proteins analyzed using UV-IF prior to top-down mass spectrometry demonstrated sensitive detection of proteins as large as 77 kDa.  相似文献   

2.
Electrospray ionization mass spectrometry (ESI-MS) is used to selectively detect analytes with a high affinity for metal ions. The detection method is based on the selective monitoring of a competing ligand at its specific m/z value that is released during the ligand-exchange reaction of a metal-ligand complex with analyte(s) eluting from a reversed-phase liquid chromatography column. The ligand-exchange reaction proceeds in a postcolumn reaction detection system placed prior to the inlet of the electrospray MS interface. The feasibility of metal affinity detection by ESI-MS is demonstrated using phosphorylated peptides and iron(III)methylcalcein blue as reactant, as a model system. Methylcalcein blue (MCB) released upon interaction with phosphorylated peptides is detected at m/z 278. The ligand-exchange detection is coupled to a C8 reversed-phase column to separate several nonphosphorylated enkephalins and the phosphorylated peptides pp60 c-src (P) and M2170. Detection limits of 2 microM were obtained for pp60 c-src (P) and M2170. The linearity of the detection method is tested in the range of 2-80 micromol/L phosphorylated compounds (r(2) = 0.9996), and a relative standard deviation of less than 8% (n = 3) for all MCB responses of the different concentrations of phosphorylated compounds was obtained. The presented method showed specificity for phosphorylated peptides and may prove a useful tool for studying other ligand-exchange reactions and metal-protein interactions.  相似文献   

3.
We report here the application of electrospray ionization tandem mass spectrometry for the characterization of protein ubiquitylation, an important posttranslational modification of cellular proteins. Trypsin digestion of ubiquitin-conjugated proteins produces diglycine branched peptides containing the modification sites. Chemical derivatization by N-terminal sulfonation was carried out on several model peptides for the formation of a characteristic fragmentation pattern in their MS/MS analysis. The fragmentation of derivatized singly charged peptides results in a product ion distribution similar to that already observed by MALDI-TOF MS/MS. Signature fragments distinguished the diglycine branched peptides from other modified and unmodified peptides, while the sequencing product ions reveal the amino acid sequence and the location of the ubiquitylation site. Doubly charged peptide derivatives fragment in a somewhat different manner, but several fragments characteristic to diglycine branched peptides were observed under low collision energy conditions. These signature peaks can also be used to identify peptides containing ubiquitylation sites. In addition, a marker ion corresponding to a glycine-modified lysine residue produced by high-energy fragmentation provides useful information for identity verification. The method is demonstrated by the analysis of three ubiquitin-conjugated proteins using LC/MS/MS.  相似文献   

4.
Rapid protein digestion and analysis using a hybrid microchip nanoelectrospray device and time-of-flight mass spectrometry detection are reported. The device consists of a planar glass chip with microfabricated channels coupled to a disposable nanospray emitter. Reactions between substrate and enzyme (trypsin), mixed off-chip and then immediately loaded into a sample reservoir on the device, are monitored in real time following the onset of electrospray. Protein cleavage products are determined at the optimum pH for generating tryptic fragments, directly from the digestion buffer using "wrong-way-round" electrospray, i.e., monitoring (MH)+ ions from basic solutions. Intense tryptic peptide ions are observed within a few minutes following sample loading on the microchip. Proteins were identified from low femtomole or even attomole quantities of analyte/spectrum using peptide mass fingerprinting, loading 0.1-2 pmol/microL of sample on the chip. The sequence coverage for analyzed proteins ranged from 70 to 95%. The rapid analysis of human hemoglobin is demonstrated using the technique.  相似文献   

5.
Liang Z  Duan J  Zhang L  Zhang W  Zhang Y  Yan C 《Analytical chemistry》2004,76(23):6935-6940
Pressurized capillary electrochromatography (pCEC) was coupled with electrospray ionization mass spectrometry (ESI-MS) using a coaxial sheath liquid interface. It was used for separation and analysis of peptides and proteins. The effects of organic modifier and applied voltage on separation were investigated, and the effects of pH value of the mobile phase and the concentration of the electrolyte on ESI-MS signal were investigated. The resolution and detection sensitivity with different separation methods (pCEC, capillary high-performance liquid chromatography) coupled on-line with mass spectrometry were compared for the separation of a peptide mixture. To evaluate the feasibility and reliability of the experimental setup of the system, tryptic digests of cytochrome c and modified protein as real samples were analyzed by using pCEC-ESI-MS.  相似文献   

6.
On-line thin-layer chromatographic separation and electrospray mass spectrometry (TLC/ESI-MS) has been accomplished by direct linking of a commercial overpressure TLC instrument, OPLC 50, and a Q-TOF mass spectrometer. Mass spectrometric detection sensitivity and chromatographic resolution achieved by this configuration were assessed using acidic glycolipids as examples. Under the optimized conditions, a sensitivity of 5 pmol of glycosphingolipid was readily demonstrated for TLC/ESI-MS and 20 pmol for TLC/ESI-MS/MS production scanning to derive the saccharide sequence and long chain base/fatty acid composition of the ceramide. Initial preconditioning of TLC plates is necessary to achieve high sensitivity detection by reducing chemical background noise. Plates can be used repeatedly (at least 10 times) for analysis, although this may result in a minor reduction in TLC resolution. Following solvent development, separated components on the TLC plates can be detected in the conventional way by nondestructive staining or UV absorption or fluorescence and can be stored for on-line TLC/ESI-MS analysis at a later stage without reduction in mass spectrometric detection sensitivity and chromatographic resolution. Aspects for further improvement of OPLC instrumentation include use of narrower TLC plate dimensions and refined design of the eluate exit system.  相似文献   

7.
Enhanced charging, or supercharging, of analytes in electrospray ionization mass spectrometry (ESI MS) facilitates high resolution MS by reducing an ion mass-to-charge (m/z) ratio, increasing tandem mass spectrometry (MS/MS) efficiency. ESI MS supercharging is usually achieved by adding a supercharging reagent to the electrospray solution. Addition of these supercharging reagents to the mobile phase in liquid chromatography (LC)-MS/MS increases the average charge of enzymatically derived peptides and improves peptide and protein identification in large-scale bottom-up proteomics applications but disrupts chromatographic separation. Here, we demonstrate the average charge state of selected peptides and proteins increases by introducing the supercharging reagents directly into the ESI Taylor cone (in-spray supercharging) using a dual-sprayer ESI microchip. The results are comparable to those obtained by the addition of supercharging reagents directly into the analyte solution or LC mobile phase. Therefore, supercharging reaction can be accomplished on a time-scale of ion liberation from a droplet in the ESI ion source.  相似文献   

8.
M Wotske  Y Wu  DA Wolters 《Analytical chemistry》2012,84(15):6848-6855
Farnesylation involves the post-translational attachment of a 15 carbon unit to the C-terminus of proteins, thus allowing them to incorporate into membranes. The farnesylation reaction requires farnesyldiphosphate as the farnesyl group donor and is catalyzed by the farnesyltransferase. Some of the most familiar farnesylated proteins belong to the Ras protein superfamily, well-known oncoproteins. As Ras proteins require the membrane localization for the transduction of extracellular signals, farnesyltransferase inhibitors are discussed as chemotherapeutic agents. Despite the importance of this post-translational modification, farnesylated peptides have been investigated rarely by means of high-pressure liquid chromatography in combination with mass spectrometry. In this study, we examined the liquid chromatographic separation of farnesylated peptides with the help of the multidimensional protein identification technology. The peptides were further ionized by electrospray ionization and subsequently analyzed by tandem mass spectrometry. We demonstrated that farnesylated peptides are more strongly retained by reversed phase than nonfarnesylated peptides. This allowed for the identification of farnesylated peptides, if spiked into complex peptide samples. In some cases the farnesyl group was apparently split off from the peptide during the ionization process, and tandem mass spectra often revealed a neutral loss of the farnesyl moiety.  相似文献   

9.
A major limitation of mass spectrometry-based proteomics is inefficient and differential ionization during electrospray ionization (ESI). This leads to problems such as increased limits of detection and incomplete sequence coverage of proteins. Incomplete sequence coverage is especially problematic for analyses that require the detection and identification of specific peptides from a protein, such as the analysis of post-translational modifications. We describe here the development and use of aldehyde-based chemistry for the alkylation of peptide primary amines to increase peptide hydrophobicity, providing increased ionization efficiency and concomitant signal enhancement. When employed to modify the peptide products of protein tryptic digests, increased sequence coverage is obtained from combined modified and unmodified digests. To evaluate the utility of alkylation of peptides for selected reaction monitoring (SRM) assays, we alkylated a peptide from the protein Oct4, known to play a role in regulating stem cell differentiation. Increased chromatographic retention and ionization efficiency is observed for the alkylated Oct4 peptide compared to its unmodified form.  相似文献   

10.
Monobromobimane (MBB) is a lipophilic reagent that selectively modifies free cysteine residues in proteins. Because of its lipophilic character, MBB is capable of labeling cysteine residues in membrane proteins under native conditions. Reaction of MBB with the sulfhydryl groups of free cysteines leads to formation of highly fluorescent derivatives. Here we describe a procedure for the detection and relative quantitation of MBB-labeled cysteines using fluorescence and mass spectrometric analyses, which allow determination of free cysteine content and unambiguous identification of MBB-modified cysteine residues. We have applied this approach to the analysis of the free and redox-sensitive cysteine residues of a large membrane protein, the sarcoplasmic reticulum Ca2+ release channel with a molecular mass of 2.2 million Da. Labeling was performed under physiologic conditions where the channel complex is in its native environment and is functionally active. The purified MBB-labeled channel complex was enzymatically digested, and the resulting peptides were separated by reversed-phase high-performance chromatography. MBB-labeled peptides were detected by fluorescence and identified by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Under MALDI conditions, partial photolytic fragmentation of the MBB-peptide bound occurred, thus allowing convenient screening for the MBB-modified peptides in the MS spectrum by detection of the specific mass increment of 190.07 Da for MBB-modified cysteine residues. Modification of the peptides was further confirmed by tandem mass spectrometric analysis, utilizing sequencing information and the presence of the specific immonium ion for the MBB-modified cysteine residues at m/z 266.6. Quantitative information was obtained by comparison of both fluorescence and MS signal intensities of MBB-modified peptides. Combination of fluorescence with MS detection and analysis of MBB-labeled peptides supported by a customized software program provides a convenient method for identifying and quantifying redox-sensitive cysteines in membrane proteins of native biological systems. Identification of one redox-sensitive cysteine (2327) in the native membrane-bound sarcoplasmic reticulum Ca2+ release channel is described.  相似文献   

11.
Due to the dynamic nature and low stoichiometry of protein phosphorylation, enrichment of phosphorylated peptides from proteolytic mixtures is often necessary prior to their characterization by mass spectrometry. Several phosphopeptide isolation strategies have been presented in the literature, including immobilized metal ion affinity chromatography. However, that technique suffers from poor selectivity and reproducibility. Recently, titanium dioxide-based columns have been successfully employed for phosphopeptide enrichment by several research groups. Here, we present, to our knowledge, the first demonstration of the utility of zirconium dioxide microtips for phosphopeptide isolation prior to mass spectrometric analysis. These microtips display similar overall performance as TiO2 microtips. However, more selective isolation of singly phosphorylated peptides was observed with ZrO2 compared to TiO2 whereas TiO2 preferentially enriched multiply phosphorylated peptides. Thus, these two chromatographic materials possess complementary properties. For alpha- and beta-casein, Glu-C digestion provided no evident advantage compared to trypsin digestion when combined with TiO2 or ZrO2 phosphopeptide enrichment.  相似文献   

12.
The reliability and information content of diethylpyrocarbonate (DEPC) as a covalent probe of protein surface structure has been improved when used appropriately with mass spectrometric detection. Using myoglobin, cytochrome c, and beta-2-microglobulin as model protein systems, we demonstrate for the first time that DEPC can modify Ser and Thr residues in addition to His and Tyr residues. This result expands the capability of DEPC as a structural probe because about 25% of the sequence of the average protein can now be covered using this covalent labeling reagent. In addition, we establish a new approach based on mass spectrometry to ensure the structural integrity of proteins during amino acid-specific covalent labeling reactions. This approach involves monitoring the extent of modification as a function of reagent concentration and allows any small-scale or local perturbations caused by the covalent label to be readily identified and avoided. Results indicate that these dose-response plots are much more reliable and generally applicable probes of possible protein structural changes than fluorescence or circular dichroism spectroscopies. These dose-response plots also provide a means of quantitatively comparing the reactivity of each modified residue. On the basis of comparisons to known X-ray crystal structures, we find that the solvent accessibility of the reactive atom in the side chain and the presence of a nearby charged residue most affect modification rates. Finally, this improved surface mapping method has been used to determine the effect of Cu(II) binding on the structure of beta-2-microglobulin. Results confirm that Cu(II) binds His31, but not any of the other three His residues, and changes the solvent accessibility of residues near His31 and near the N-terminus.  相似文献   

13.
Chemical derivatization of peptides allows efficient F2 laser single photon ionization (SPI) of Fmoc-derivatized peptides covalently bound to surfaces. Laser desorption photoionization mass spectrometry using 337-nm pulses for desorption and 157.6-nm pulses for threshold SPI forms large ions identified as common peptide fragments bound to either Fmoc or the surface linker. Electronic structure calculations indicate the Fmoc label is behaving as an ionization tag for the entire peptide, lowering the ionization potential of the complex below the 7.87-eV photon energy. This method should allow detection of many molecular species covalently or electrostatically bound to surfaces.  相似文献   

14.
Protein tyrosine nitration (PTN) is a post-translational modification that is related to several acute or chronic diseases. PTN introduces a nitro group in the ortho position of the phenolic hydroxyl group of tyrosine residues. PTN has been shown to be involved in the pathogenesis of inflammatory responses, cancers, and neurodegenerative and age-related disorders. Furthermore, it has been proposed that PTN regulates signal cascades related to nitric oxide (NO·) production and NO-mediated processes. Although nitrated proteins as markers of oxidative stress are confirmed by immunological assays in various affected cells or tissues, it is not known how many different types of proteins in living cells are nitrated. Since protein nitration is a low-abundance post-translational modification, development of an effective enrichment method for nitrated proteins is needed to detect nitrated peptides or proteins from the limited amount of pathophysiological samples. In the present study, we developed an enrichment method using specific chemical tagging. Nitroproteome profiling using chemical tagging and mass spectrometry was validated by model proteins. Furthermore, we successfully identified numerous nitrated proteins from the Huh7 human hepatoma cell line.  相似文献   

15.
A solution additive has been discovered that can be used to measure the number of basic sites in a peptide or protein using electrospray ionization (ESI) mass spectrometry. Addition of millimolar amounts of perchloric acid (HClO(4)) to aqueous solutions that contain peptides or proteins results in the noncovalent adduction of HClO(4) molecules to the multiply charged ions formed by ESI. For 18 oligopeptides and proteins, ranging in molecular weight from 0.5 to 18.3 kDa, the sum of the number of protons plus maximum number of HClO(4) molecules adducted to the lower charge state ions is equal to the number of basic sites in the molecule. This method provides a rapid means of obtaining information about the composition of a peptide or protein and does not require high-resolution measurements or any instrumental or experimental modifications.  相似文献   

16.
Meng W  Zhang H  Guo T  Pandey C  Zhu Y  Kon OL  Sze SK 《Analytical chemistry》2008,80(24):9797-9805
Protein identification from samples resolved by one-dimensional and two-dimensional gel electrophoresis is highly dependent on the recovery of trypsin-digested peptides prior to mass spectrometric analysis. The commonly used two-step protocol for extracting tryptic peptides, involving high-volume organic solvent extraction and cleanup via microscale reversed-phase micropipet tip or microcolumn is not only limited by significant sample loss but is also costly and very labor-intensive. We report here a simple one-step procedure for simultaneous peptide extraction and cleanup by incubating a small piece of C18 Empore Disk (3M) with the in-gel digested solution. We show that the direct Empore Disk-based peptide extraction procedure is convenient, economical, and has higher efficiency as compared with the commonly used two-step protocol for peptide preparation prior to MS analysis.  相似文献   

17.
Carboxylated/oxidized diamond nanoparticles (nominal size 100 nm) exhibit exceptionally high affinity for proteins through both hydrophilic and hydrophobic forces. The affinity is so high that proteins in dilute solution can be easily captured by diamonds, simply separated by centrifugation, and directly analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS). No preseparation of the adsorbed molecules from diamonds is required for the mass spectrometric analysis. Compared to conventional MALDI-TOF-MS, an enhancement in detection sensitivity by more than 2 orders of magnitude is achieved for dilute solution containing cytochrome c, myoglobin, and albumin because of preconcentration of the probed molecules. The lowest concentration detectable is 100 pM for a 1-mL solution. Aside from the enhanced sensitivity, the overall performance of this technique does not show any sign of deterioration for highly contaminated protein solutions, and furthermore, no significant peak broadening and band shift were observed in the mass spectra. The promise of this new method for clinical proteomics research is demonstrated with an application to human blood serum.  相似文献   

18.
Nonporous (NPS) RP-HPLC has been used to rapidly separate proteins from whole cell lysates of human breast cell lines. The nonporous separation involves the use of hard-sphere silica beads of 1.5-microm diameter coated with C18, which can be used to separate proteins ranging from 5 to 90 kDa. Using only 30-40 microg of total protein, the protein molecular weights are detectable on-line using an ESI-oaTOF MS. Of hundreds of proteins detected in this mass range, approxinately 75-80 are more highly expressed. The molecular weight profiles can be displayed as a mass map analogous to a virtual "1-D gel" and differentially expressed proteins can be compared by image analysis. The separated proteins can also be detected by UV absorption and differentially expressed proteins quantified. The eluting proteins can be collected in the liquid phase and the molecular weight and peptide maps determined by MALDI-TOF MS for identification. It is demonstrated that the expressed protein profiles change during neoplastic progression and that many oncoproteins are readily detected. It is also shown that the response of premalignant cancer cells to estradiol can be rapidly screened by this method, demonstrating significant changes in response to an external agent. Ultimately, the proteins can be studied by peptide mapping to search for posttranslational modifications of the oncoproteins accompanying progression.  相似文献   

19.
We studied the effects of electrospray mass spectrometric instrumental settings on the relative and absolute detection of individual proteins in a five-component mixture. Conditions that were effective for a given protein could be very poor for the others, and vice versa, such that to a good approximation it was possible to find conditions for selective detection of individual proteins in a complex mixture without prior analytical separation. Some of these could be rationalized on the basis of the known biophysical properties of the individual proteins. The ability to vary the conditions of a mass spectrometric detection method on-line provides an important degree of freedom for the selective detection, and hence discrimination, of individual proteins and peptides in complex mixtures and has implications in proteomics, in particular with respect to top-down strategies for proteomic characterizations.  相似文献   

20.
In the present study, we developed a sensitive and highly selective method of detecting the biosynthetic intermediates involved in the gentamicin pathway from a cell culture of Micromonospora echinospora. A novel extraction method utilizing a dual solid-phase extraction (SPE) technique was employed to purify and recover all of the gentamicin-related components from the cell culture broth, and high-performance liquid chromatography (HPLC) coupled with electrospray ionization mass spectrometry (ESI-MS/MS) was used to analyze the extractant for gentamicin intermediates. The pH of the culture broth was adjusted to an acidic condition of pH 2 prior to the extraction. The samples were first cleaned with a reversed-phase AccuBOND C(18) cartridge, and then the aminoglycosidic components were purified using a cationic exchanger OASIS MCX cartridge. The detection limit of a gentamicin standard spiked in blank medium processed by this method was found to be approximately 5 ng for each component of the gentamicin C complex, and the mean recovery for each component of standard gentamicin was above 91% when analyzed by HPLC-ESI-MS/MS. We further demonstrated that this method enables the analytical profiling of the gentamicin-related compounds produced by wild-type M. echinospora ATCC 15835, which mainly produces the gentamicin C complex, and the UV-induced mutant strain KCTC 10506BP, which produces gentamicin B as the major product. Seven intermediates (paromamine, gentamicin A2, B, X2, A, JI-20A, and JI-20B) besides the gentamicin C complex were detected in the culture broth of both M. echinospora strains when analyzed by MS/MS for the distinct fragmentation patterns of each gentamicin component. This report displays the first example of the HPLC profiling in a wide range of structurally related biosynthetic intermediates involved in the gentamicin pathway.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号