首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
铜锍经混合酸消解溶样处理,标准溶液中加入一定含量的Cu,Fe进行基体匹配,电感耦合等离子体发射光谱法测定矿样中镉、砷、铅、锌含量。方法基体效应较小,各待测元素之间没有明显干扰。使用该法分析有证标准物质和实际样品,分析结果与认定值和其他常规方法测定值一致,均在允许误差范围内。方法的回收率:Cd为85%~93%,As为90%~98%,Pb为92%~111%,Zn为92%~107%;方法的精密度(RSD,n=12)为0.75%~2.55%。与现行的单元素分析方法相比,分析周期短,适用于工厂中间产物和大宗铜锍商品  相似文献   

2.
试样经盐酸-硝酸-氢氟酸-高氯酸四酸溶解,盐酸复溶作介质,用火焰原子吸收光谱法连续测定矿石中铜、铅、锌和银四种元素。实验结果表明,四酸溶样效果最佳,相对标准偏差(n=5)Cu:0.92%~2.63%,Pb:1.12%~3.04%,Zn:0.80%~2.47%,Ag:1.15%~2.98%;加标回收率Cu:96.8%~104.0%,Pb:96.8%~101.8%,Zn:98.1%~103.3%,Ag:97.2%~102.2%;测定范围Cu的为1~500μg·g-1,Pb的为5~2 000μg·g-1,Zn为5~1 000μg·g-1,Ag为0.5~200μg·g-1。方法前处理简单、实用,同时连续测得多种元素,满足地矿实验室的日常检测。  相似文献   

3.
探讨了12Cr_2Mo_1R焊缝金属制备方法、分析功率和助熔剂对氧、氮和氢测定的影响,建立了采用惰气熔融-红外热导法对12Cr_2Mo_1R焊缝金属中氧、氮和氢同时测定的方法。实验表明:采用火花源线切割与加冷却液车削的联合加工样品方法,设定分析功率为4 500 W,不加助熔剂,可直接对氧、氮和氢进行测定。氧、氮和氢的检出限分别为0.000 082 2%、0.000 648%和0.000 047 7%,测定下限分别0.000 274%、0.002 16%和0.000 159%。采用实验方法对兰石重装公司内部生产的12Cr_2Mo_1R焊缝金属实际样品进行测定,氧、氮和氢结果的相对标准偏差(RSD,n=5)分别为0.9%~4.8%、0.9%~5.4%和4.0%~6.2%;对实际样品加入钢铁标准样品进行加标回收试验,回收率分别在99%~105%、98%~102%和91%~94%之间。  相似文献   

4.
钢中砷、铅、锑、锡的辉光放电原子发射光谱分析   总被引:4,自引:0,他引:4       下载免费PDF全文
通过辉光光谱仪预溅射参数和积分时间等因素对钢中微量元素砷、铅、锑、锡辉光光谱行为的影响试验,建立了辉光放电发射光谱法同时测定钢中砷、铅、锑、锡的方法。测定范围分别为:w(As)=0.004 5%~0.008 7%,w(Pb)=0.000 2%~0.13%,w(Sb)=0.001 1%~0.072%,w(Sn)=0.003 1%~0.079%。该方法的精密度和准确度令人满意,对质量分数为0.003%~0.015%砷、铅、锑、锡的测定(n=9),RSD<2%,测定结果与认定值十分吻合。  相似文献   

5.
专利信息     
《钛工业进展》2020,(1):41-41
一种近β型高强韧钛合金及其制备方法申请号:CN201910301923.3申请日:20190416公开(公告)日:20190607公开(公告)号:CN109852845A申请(专利权)人:西部钛业有限责任公司摘要:本发明公开了一种近β型高强韧钛合金,其化学成分(质量分数)为:Al 4.0%~5.5%,Zr 0.8%~1.8%,Mo 3.0%~4.5%,V 1.0%~2.0%,Fe 1.5%~2.5%,Cr 2.5%~3.5%,B不超过0.12%,余量为Ti和不可避免的杂质,同时公开了这种近β型高强韧钛合金的制备方法。分别采用Al-Zr系、Mo-V-Cr-Fe系合金共同强化其α相和β相,增强耦合强化效果,并控制铝当量和钼当量,保证其兼具良好的强度和韧性;此外,该合金以TA15钛合金回收料作为原料,大大降低了制备成本。  相似文献   

6.
石煤钒矿中五氧化二钒测定方法的确认与应用   总被引:1,自引:0,他引:1  
对石煤钒矿中五氧化二钒测定方法的科学性和准确性进行了确认研究。结果表明:五氧化二钒质量分数测定量值可溯源;方法相对标准偏差为1.23%~3.95%,有证标准物质(CRM)样品验证相对误差为0.17%~1.55%,加标回收率为98.96%~101.02%。确认的方法具有较高的科学性与准确性,应用于石煤钒矿成分分析标准物质定值中,所得结果满意。  相似文献   

7.
研究建立了王水溶样—电感耦合等离子体原子发射光谱测定酸泥中硒、碲含量的分析方法,通过实验对仪器工作参数、分析线的选择等进行了研究,确定了合适的分析线和仪器分析条件,并对本方法进行了精密度和准确度实验。实验结果显示,硒的相对标准偏差(RSD,n=7)为1.40%~1.67%,加标回收率为99.4%~107.7%,碲的相对标准偏差(RSD,n=7)为1.82%~2.44%,加标回收率为95.0%~104.0%,满足样品中硒、碲分析测定要求。  相似文献   

8.
采用盐酸-硝酸-高氯酸混合酸消解样品,盐酸为介质,电感耦合等离子体发射光谱法测定金精矿中铜、铅、锌、镉。方法检出限分别为Cu 0.002 2μg/m L、Pb 0.014 0μg/m L、Zn 0.004 2μg/m L、Cd 0.003 5μg/m L,加入标准物质回收率分别为Cu 97.67%~102.25%、Pb 96.97%~105.07%、Zn 97.00%~105.50%、Cd 95.00%~105.00%,测定结果的相对标准偏差分别为Cu 3.03%~3.79%、Pb 1.24%~4.52%、Zn 1.62%~3.91%、Cd 1.94%~4.16%。该方法操作简单、准确可靠,满足实验室检测需求,适合大批量样品的测定。  相似文献   

9.
正专利号:ZL201410535894.4专利权人:河北钢铁股份有限公司邯郸分公司专利内容:本发明公开了一种800 MPa级冷轧双相钢及其生产方法,其包括热轧和冷轧连退工序,所述进入热轧工序的铸件化学成分的质量百分含量为:C 0.14%~0.17%,Si 0.45%~0.55%,Mn1.6%~1.8%,Cr 0.55%~0.65%,P≤0.016%,S  相似文献   

10.
正申请号:201710256487.3申请日:2017-04-19摘要:本发明是一种抗酸耐蚀管线钢,其重量百分比成分为:C:0.02%~0.04%,Si:0.10%~0.35%,Mn:0.9%~1.40%,P:0.012%,S:0.0010%,Nb:0.020%~0.070%,Ti:0.006%~0.020%,Ni:0.30%,Cr:0.10%~0.30%,Cu:0.10%~0.30%,Al:0.015%~0.050%,余量为Fe和杂质。本发明采用一种低碳、低磷硫、低气体含  相似文献   

11.
The application of alkyl phosphoric acid ester for the flotation of wolframite was investigated. The studies include flotation of pure wolframite as a function of pulp pH, surfactant concentration, and particle size. The response contours were explained on the basis of solution properties of alkyl phosphoric acid ester. The performance of alkyl phosphoric acid collector has been compared with other commercially used wolframite flotation reagents. The efficacy of the reagent was also tested using a low-grade quartz vein type tungsten ore (WO3 0.2%) having wolframite as the chief tungsten-bearing mineral. Different parameters that influence the flotation selectivity (pH, collector and dispersant dosage, kinetics) were investigated in the bench scale studies. A continuous flotation test with a reagent regime of alkyl phosphoric acid collector-sodium silicofluoride modifier—amyl alcohol frother—gave a float product analyzing WO3 8% with 68% overall recovery after multistage flotation. The tungsten metal values from this cleaner float can be extracted efficiently using established hydrometallurgical methods.  相似文献   

12.
采用N235从镍钼矿盐酸浸出液中萃取钼的研究   总被引:3,自引:0,他引:3  
采用N235对镍钼矿盐酸浸出液进行了萃取钼的研究。试验结果表明,在最佳工艺条件下,5级逆流钼萃取率可达98%以上,镍损失率小于1%,负载有机相经稀酸洗涤除铁后采用氨水反萃,1级反萃率达97%以上,反萃液钼浓度为50 g/L左右,达到了钼镍分离及钼富集转型的目的。  相似文献   

13.
治理钼精矿焙烧烟气中低浓度SO2的新工艺--柠檬酸吸收法   总被引:4,自引:1,他引:3  
采用柠檬酸溶液吸收焙烧烟气中低浓度SO2 ,使烟气达到国家排放标准。用气提法解析 ,解析率达 99.78%,试验效果良好。  相似文献   

14.
锰矿石脱磷新工艺的研究   总被引:2,自引:1,他引:1  
黄枢  肖琪 《中国锰业》1993,11(4):27-31
研究开发出一种高磷碳酸锰矿的化学脱磷新方法:加氯化钙焙烧—稀盐酸浸出法。实验室试验表明,用此法处理花垣锰矿的两种高磷磁选精矿,最终产品锰品位提高约0.5倍,锰回收率达98%,磷锰比由0.01~0.013降低到0.002—0.0021,脱磷率达80—85%。指标优于其他方法,盐酸用量仅为黑锰矿法的22%。  相似文献   

15.
杨丽飞  苏明跃  李异  刘静 《铁合金》2012,43(1):45-48
探讨了显色体系的稳定性,其酸度、显色剂用量、样品主要基体以及残余高氯酸对检测的影响。选择了适宜的显色时间、硝酸加入量、显色剂用量等检测条件。磷溶液浓度在2~10 mg/L范围内呈良好的线性关系。检测磷铁中磷含量,回收率可达99.8%~101.4%,相对标准偏差小于2.71%。对磷铁标准样品进行分析,结果同认定值完全一致。  相似文献   

16.
本文用ICP-MS仪直接测定了硅铁中的Ca、Al、Mn、Cr、P的含量。硅铁用HF-HNO3混合酸低温溶解完全后.加入高氯酸除氟,用硝酸溶解盐类,加入内标元素^45Sc,采用内标法,用ICP-MS仪进行测定。讨论了基体铁的影响及硅对Ca测定的影响。该方法的加标回收率为:98.2%~102%;相对标准偏差RSD为1.6%~3.5%。本文所研究的方法具有简便、快速、准确等特点,可用于硅铁样品微量杂质元素的分析。  相似文献   

17.
分析了含大量氯离子的酸性溶液中钼的存在形态,论证了采用TRPO萃取剂直接从该浸出液中萃取钼的可行性。试验考察了萃取剂浓度、萃取时间、萃取温度、相比、萃取级数等萃取参数。在其他条件适宜,O/A=1/3时,两级逆流萃取可以萃取99.5%的钼。  相似文献   

18.
用氢氟酸、硝酸溶解样品,采用电感耦合等离子体发射光谱法测定碳化铌中钽、钛含量,考察了样品基体铌对待测元素的干扰影响,优选元素分析谱线和仪器最佳分析参数,采用铌基体打底配制校准曲线消除对待测元素的干扰,建立了最佳测量条件。方法检出限为钽0.000 15%、钛0.000 23%,相对标准偏差<2%,回收率在97.8%~104.0%之间,与化学法比对,结果一致,表明本方法具有很好的精密度和准确度,能够满足日常检测的需要。  相似文献   

19.
以平煤集团天宏焦化公司3万t/年酸洗法粗苯精制废酸再生处理在硫铵工艺中使用的技术研发过程为基础,研究探索焦化苯精制废酸处理的新工艺,在工业试验中,采用泡沫分离、聚合、乳化物破乳化以及气浮主要工艺技术,将废酸处理到酸焦油、COD脱除率达到85%,满足化产回收硫铵工艺的使用,取得了较好的效果。  相似文献   

20.
采用WSA制酸,设计和实际生产过程中产品硫酸的浓度达不到98%以上,影响产品销售。通过采取措施和对工艺进行调节,降低烟气净化后的烟气温度在30℃以下,控制硅酸钠的添加量和循环酸的排放频率;实现了酸浓的提高。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏