1.
The performance of rehabilitated reinforced concrete beam-column joints was compared with the response of existing joints designed to preseismic codes to assess proposed rehabilitation techniques. Six beam-column subassemblies with nonductile reinforcement detailing were tested. The joints were subjected to quasi-static load that simulates seismic forces. The first three specimens had inadequate anchorage length of the bottom beam bars. Two of them were strengthened by using carbon-fiber-reinforced polymer sheets attached to the bottom beam face and then tested. The other three specimens had no steel ties installed in the joint zone, in addition to inadequate anchorage length of the beam bars. Two of the beam-column joints were strengthened by glass-fiber-reinforced polymer jackets of the joint zone and steel rods or plates. The rehabilitation techniques were found effective in eliminating the brittle joint shear and steel bar bond-slip failure modes, and ductile beam hinging instead occurred.  相似文献   

2.
The research presented in this study involves full-scale experimental evaluation of carbon fiber-reinforced polymer (CFRP) rehabilitation for existing beam-column joints designed for gravity load with common pre-1970s deficient reinforcement details when subjected to cyclic loading. Numerous studies have demonstrated effectiveness of externally bonded fiber-reinforced polymer (FRP) materials for retrofitting the deteriorating RC structures. Although these materials are widely used in bridges, their applications in buildings have been somewhat limited. In particular, the experimental investigations on external FRP retrofit of deficient beam-column joints have not thoroughly been investigated and they are mainly on scaled-down specimens. The failure of these subassemblies, which possess lack of shear reinforcement within the joint core and shortly embedded positive beam reinforcement, would possibly result in catastrophic collapse of reinforced concrete frame structure during an earthquake event. Recognizing the urgent need to upgrade these structural subassemblies, the current investigation uses CFRP retrofit techniques to enhance the performance of such deficient joints. Experimental variables studied entail the developed CFRP retrofit configurations, and magnitude of the applied column axial load. Comparative analysis of the lateral loads versus drift hysteresis loops, stiffness degradation, and total dissipated energy curves of three as-built and three corresponding CFRP-retrofitted RC joints revealed that significant improvement in the shear capacity of the upgraded joints occurred. More importantly, the slippage of short embedded beam positive reinforcement into the joint was substantially controlled due to the developed CFRP retrofit. The results demonstrate the effectiveness of CFRP retrofit configurations in enhancing the structural performance of actual size connections.  相似文献   

3.
Shear failure of exterior beam-column joints is identified as the principal cause of collapse of many moment-resisting frame buildings during recent earthquakes. Effective and economical strengthening techniques to upgrade joint shear resistance and ductility in existing structures are needed. In this paper, efficiency and effectiveness of carbon fiber-reinforced polymer (CFRP) sheets in upgrading the shear strength and ductility of seismically deficient exterior beam-column joints have been studied. Four as-built joints were constructed with nonoptimal design parameters (inadequate joint shear strength with no transverse reinforcement) representing preseismic code design construction practice of joints and encompassing most of existing beam-column connections. Out of these four as-built specimens, two specimens were used as baseline specimens (control specimens) and other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All of these four subassemblages were subjected to cyclic lateral load histories so as to provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks through epoxy and externally bonding them with CFRP sheets under the same above two schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles, joint shear distortion, ductility, and stiffness degradation. The comparison shows that CFRP sheets are very effective in improving shear resistance and deformation capacity of the exterior beam-column joints and delaying their stiffness degradation.  相似文献   

4.
In this paper, the efficiency and effectiveness of carbon-fiber-reinforced polymer (CFRP) sheets for upgrading the shear strength and ductility of a seismically deficient exterior beam-column joint were studied and compared with an American Concrete Institute (ACI)-based design joint specimen. One as-built joint specimen, representing the preseismic code design and construction practice for joints and one ACI-based design joint specimen, satisfying the seismic design requirements of the current code of practice were cast. The as-built specimen was used as baseline (control) specimen. These two specimens (i.e., the as-built control and the ACI-based specimens) were subjected to cyclic lateral load histories to induce damage equivalent to damage expected from a severe earthquake. The damaged control specimen was then repaired by filling its cracks with epoxy and externally bonding CFRP sheets to the joint, the beam, and part of the column regions. This specimen was identified as the repaired specimen. The repaired specimen was subjected to a similar cyclic lateral load history, and its response history was recorded. The response histories of the as-built control, the repaired, and the ACI-based design specimen were then compared. The test results demonstrated that externally bonded CFRP sheets can effectively improve both the shear strength and the deformation capacity of seismically deficient and damaged beam-column joints to a state comparable to the ACI-based design joint.  相似文献   

5.
Analytical models are presented in this study for the analysis of reinforced concrete joints strengthened with composite materials in the form of externally bonded reinforcement comprising unidirectional strips or flexible fabrics. The models provide equations for stresses and strains at various stages of the response (before or after yielding of the beam or column reinforcement) until the ultimate capacity is reached, defined by concrete crushing or fiber-reinforced polymer (FRP) failure due to fracture or debonding. Solutions to these equations are obtained numerically. The models provide useful information on the shear capacity of FRP-strengthened joints in terms of the quantity and configuration of the externally bonded reinforcement and may be used to design FRP patching for inadequately detailed beam-column joints. A number of case studies are examined in this article, indicating that even low quantities of FRP materials may provide significant enhancement of the shear capacity. The effectiveness of external reinforcement increases considerably if debonding is suppressed and depends heavily on the distribution of layers in the beam and column. The latter depends on the relative quantities of steel reinforcement crossing the joint panel and the level of axial load in the column. Analytical shear strength predictions were in good agreement with test results found in the literature, thus adding confidence to the validity of the proposed models.  相似文献   

6.
In this paper, efficiency and effectiveness of carbon fiber reinforced polymers (CFRPs) in upgrading the shear strength and ductility of seismically deficient corner or knee reinforced concrete beam-column joints have been studied. For this purpose, four as-built corner/knee joints were constructed with no transverse reinforcement, representing extreme case of preseismic code design construction practice of joints and encompassing many existing beam-column corner joints. Out of these four as-built specimens, two specimens were used as baseline specimens (control specimens) and other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All these four subassemblages were subjected to cyclic lateral load histories to simulate loading due to earthquake and provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks through epoxy and externally bonding them with CFRP sheets under the same above two schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles, ductility, and stiffness degradation. The comparison shows that CFRP sheets are very effective in improving shear resistance and deformation capacity of the corner beam-column joints and delaying their stiffness degradation. Shear capacities of control, repaired, and strengthened specimens were also predicted using writers’ published formulation. The predicted shear capacities were in a good agreement with the experimental values.  相似文献   

7.
Two series of tests on eight full-scale exterior beam-column joint subassemblages built with plain bars and low-strength concrete were conducted. No transverse reinforcement was present in the joint cores. In the first series of tests, which included three specimens, the behavior of joints before fiber-reinforced polymer (FRP) retrofitting was investigated. In the second series, which included five specimens, the behavior of the FRP-retrofitted joints was investigated. The six specimens consisted of a column, an in-plane beam, a transverse beam, and a slab part, and two specimens were plane members without transverse beams and slabs. The utilized retrofitting scheme is easily applicable for actual exterior beam-column joints, even in the presence of a transverse beam and a slab. Two types of strength limitation were observed for specimens in the first series. The strength of the specimen with beam longitudinal bars sufficiently anchored to the joint core was limited by the shear strength of the joint. The strengths of the other two specimens were limited by the slip of the beams’ longitudinal bars at their anchorages. In the second series of tests, significantly better performance was obtained both in terms of shear strength and ductility, provided that the slip of the beam bars was prevented. Furthermore, by using a simple theoretical algorithm based on truss analogy, the strength and deformability characteristics of the tested reference and FRP-retrofitted joints are predicted with reasonable accuracy. The same algorithm is used for predicting the joint shear strength of specimens tested by other researchers, and satisfactory agreement is obtained between the predictions and test results.  相似文献   

8.
The State Street Bridge, in Salt Lake City, was designed and built in 1965 according to the 1961 AASHO specifications; the design did not include earthquake-induced forces or displacements since only wind loads were considered. The bridge consists of four reinforced concrete (RC) bents supporting composite welded steel girders; the bents are supported on cast-in-place concrete piles and pile caps. A vulnerability analysis of the bridge was conducted that determined deficiencies in (1) confinement of column lap splice regions, (2) anchorage of longitudinal column bars in the bent cap, (3) confinement of column plastic hinge zones, and (4) shear capacity of columns and bent cap–column joints. Seismic retrofit designs using carbon-fiber-reinforced-polymer (CFRP) composites and steel jackets were performed and compared for three design spectra, including the 10% probability of exceedance in 250 years earthquake. The CFRP composite design was selected for implementation and application of the composite was carried out in the summer of 2000 and 2001, while the bridge was in service. The paper describes the CFRP composite design, which, in addition to column jackets, implemented an “ankle wrap” for improving joint shear strength and a “U-strap” for improving anchorage of column bars in the bent cap; other retrofit measures were implemented, such as bumper brackets and a deck slab retrofit. A capacity versus demand evaluation of the as-built and retrofitted bents is presented.  相似文献   

9.
In this paper, efficiency and effectiveness of carbon fiber-reinforced polymers (CFRP) in upgrading the shear strength and ductility of seismically deficient beam-column joints have been studied. For this purpose, four reinforced concrete interior beam-column sub-assemblages were constructed with nonoptimal design parameters (inadequate joint shear strength with no transverse reinforcement) representing preseismic code design construction practice of joints and encompassing the vast majority of existing beam-column connections. Out of these four, two specimens were used as baseline specimens (control specimens) and the other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to the joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to the joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All four subassemblages were subjected to cyclic lateral load histories so as to provide the equivalent of severe earthquake damage. Further, the damaged control specimens were repaired after filling the cracks through epoxy and wrapping them with CFRP sheets under the same two above-mentioned schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Hence, a total of six specimens were tested: two control; two strengthened; and two repaired. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles (maximum horizontal displacements of column along its height), joint shear distortion, ductility, and stiffness degradation. The comparison shows that CFRP sheets improve the shear resistance of the joint and increase its ductility. Results of two chosen schemes of strengthening were also compared and the importance of beam upgrading was highlighted.  相似文献   

10.
The rehabilitation of RC columns jacketed with carbon fiber-reinforced plastic (FRP) composites for improving shear strength, confinement, and ductility has received considerable attention. However, research for improving the shear capacity of beam-column T-joints using FRP composite materials is still in the early stages. The present paper describes the experimental results of 14 1∕3-scale tests of concrete beam-column joints. The variables considered were the composite system, the fiber orientation, and the surface preparation. The tests have demonstrated the viability of carbon FRP composites for their use in improving the shear capacity of the joints as evidenced by the experimental results. Based on these experimental results, a design aid was developed for T-joints with inadequate confinement and shear reinforcement.  相似文献   

11.
Experimental tests were conducted on six 1/3-scale specimens to define the vulnerabilities of existing outrigger bents under in-plane and out-of-plane seismic loading and to develop retrofit measures that address the identified vulnerabilities. The specimens represented knee joints in the SR 99 Spokane Street overcrossing in western Washington State but included deficiencies present in a number of older bridges. The as-built specimens failed at low ductility levels due to shear distress, low torsional strength of the outrigger beam, and reinforcement bond failures within the joint. Threshold principal tension stress values describing the expected condition of the joints were established and compared to values obtained by other researchers. Circular steel jackets were used to retrofit the as-built specimens. The retrofitted specimens developed plastic hinging in the column, with enhanced strength, energy, and ductility capacities. Design and detailing guidelines for retrofitting outrigger bents were proposed.  相似文献   

12.
The objective of this research is to investigate the seismic performance of as-built, retrofitted, and repaired hollow bridge columns with insufficient shear strength. Two as-built full-scale columns were first tested and repaired using carbon-fiber-reinforced polymer composites (CFRP) jackets and dog-bone-shaped bars and then retested. Another two columns having the same reinforcement as the as-built columns were retrofitted with CFRP jackets. In addition to the tests, the repairability of the failed hollow columns was investigated by analytical evaluation. The test results and analysis of the retrofitted columns showed that CFRP composites can effectively strengthen shear-critical hollow bridge columns and can successfully transform the failure mode from shear to flexure. The test results of the repaired circular columns show that dog-bone-shaped bars successfully repaired the flexural damage caused by the fractured longitudinal bars.  相似文献   

13.
This paper presents the results of an experimental study designed to investigate the viability of using externally bonded carbon-fiber-reinforced polymer (CFRP) laminates to extend the service life of corroded reinforced concrete (RC) beams. A total of 14 beams, 152×254×3,200?mm each, were tested. Three beams were not corroded; two of them were strengthened by CFRP laminates, while one specimen was kept as a virgin. The remaining 11 beams were subjected to different levels of corrosion damage up to a 31% steel mass loss using an impressed current technique. Six of the corroded beams were repaired with CFRP laminates, whereas the remaining five beams were not repaired. Eventually, all specimens were tested to failure under four-point bending. Corrosion of the steel reinforcement significantly reduced the load-carrying capacity of RC beams. At all levels of corrosion damage, CFRP repair increased the ultimate strengths of the corroded beams to levels higher than the strength of the virgin beam but significantly reduced the deflection capacity.  相似文献   

14.
To assess the viability of the external confinement of normal-strength concrete beam–column joints with carbon fiber-reinforced polymer (CFRP) sheets in increasing the bond strength of hooked bars anchored in the joints, 12 hooked bar specimens were tested. The variables were beam tensile bar size, anchorage length, mode of confinement of the beam hooked bars in the beam–column joint (whether the hooked bars were anchored within or outside the column reinforcement cage, denoted as “confined specimens” or “unconfined specimens”), and presence or absence of FRP wraps. The specimen simulated the rigid connection of a cantilever beam to a column. The tensile beam reinforcement consisted of two bars anchored in the base column using hooked-bar anchorages. Test results indicated that FRP sheets were effective in increasing the anchorage capacity and the ductility of the load–deflection history for both unconfined and confined specimens. However, FRP sheets had a more significant influence on unconfined specimens than companion confined specimens. As compared with unconfined specimens without FRP wrapping, unconfined FRP specimens had an average of a 23% increase in bond strength, confined non-FRP specimens had an average 30% increase in bond strength, and confined FRP specimens had an increase of 54%.  相似文献   

15.
Shear failure is catastrophic and occurs usually without advance warning; thus it is desirable that the beam fails in flexure rather than in shear. Many existing reinforced concrete (RC) members are found to be deficient in shear strength and need to be repaired. Externally bonded reinforcement such as carbon-fiber-reinforced polymer (CFRP) provides an excellent solution in these situations. To investigate the shear behavior of RC beams with externally bonded CFRP shear reinforcement, 11 RC beams without steel shear reinforcement were cast at the concrete laboratory of the New Jersey Institute of Technology. After the beams were kept in the curing room for 28?days, carbon-fiber strips and fabrics made by Sika Corp. were applied on both sides of the beams at various orientations with respect to the axis of the beam. All beams were tested on a 979?kN (220?kips) MTS testing machine. Results of the test demonstrate the feasibility of using an externally applied, epoxy-bonded CFRP system to restore or increase the shear capacity of RC beams. The CFRP system can significantly increase the serviceability, ductility, and ultimate shear strength of a concrete beam; thus, restoring beam shear strength by using CFRP is a highly effective technique. An analysis and design method for shear strengthening of externally bonded CFRP has been proposed.  相似文献   

16.
The feasibility and efficiency of a seismic retrofit intervention using externally bonded fiber-reinforced polymer composites on existing reinforced concrete frame systems, designed prior to the introduction of modern standard seismic design code provisions in the mid-1970s, are herein presented, based on analytical and experimental investigations on beam-column joint subassemblies and frame systems. A multilevel retrofit strategy, following hierarchy of strength considerations, is adopted to achieve the desired performance. The expected sequence of events is visualized through capacity-demand curves within M-N performance domains. An analytical procedure able to predict the enhanced nonlinear behavior of the panel zone region, due to the application of CFRP laminates, in terms of shear strength (principal stresses) versus shear deformation, has been developed and is herein proposed as a fundamental step for the definition of a proper retrofit solution. The experimental results from quasi-static tests on beam-column subassemblies, either interior and exterior, and on three-storey three-bay frame systems in their as-built and CFRP retrofitted configurations, provided very satisfactory confirmation of the viability and reliability of the adopted retrofit solution as well as of the proposed analytical procedure to predict the actual sequence of events.  相似文献   

17.
For reinforced concrete beams with the same shear and flexural reinforcements, shear failure is most likely to occur in deep beams rather than in regular beams. Thus, retrofitting of deep beams with shear deficiencies is of great importance. Externally bonded reinforcement such as carbon fiber reinforced polymer (CFRP) provides an excellent solution in these situations. In order to investigate the shear behavior of deep beams with externally bonded CFRP shear reinforcement, 16 deep beams without steel shear reinforcement were cast at the concrete laboratory of New Jersey Institute of Technology. After the beams were kept in the curing room for 28 days, carbon fiber strips and fabrics were applied outside of the beams at various orientations with respect to the axis of the beam. All beams were tested on a 979?kN (220?kip) MTS testing machine. Results of test demonstrate the feasibility of using externally applied, epoxy-bonded CFRP system to restore or increase the shear capacity of deep beams. The CFRP system can significantly increase the serviceability, ductility, and ultimate shear strength of a concrete beam, thus restoring deep beam shear strength using CFRP is a highly effective technique. An analysis and design method for shear strengthening of deep beams using externally bonded CFRP has also been proposed as well.  相似文献   

18.
A strengthening technique, combining carbon fiber-reinforced polymer (CFRP) laminates and strips of wet layup CFRP sheet, is used to increase both the flexural and the energy dissipation capacities of reinforced concrete (RC) columns of square cross section of low to moderate concrete strength class, subjected to constant axial compressive load and increasing lateral cyclic loading. The laminates were applied according to the near surface mounted technique to increase the flexural resistance of the columns, while the strips of CFRP sheet were installed according to the externally bonded reinforcement technique to enhance the concrete confinement, particularly in the plastic hinge zone where they also offer resistance to the buckling and debonding of the laminates and longitudinal steel bars. The performance of this strengthening technique is assessed in undamaged RC columns and in columns that were subjected to intense damage. The influence of the concrete strength and percentage of longitudinal steel bars on the strengthening effectiveness is assessed. In the groups of RC columns of 8 MPa concrete compressive strength, this technique provided an increase of about 67% and 46% in terms of column’s load carrying capacity, when applied to undamaged and damaged columns, respectively. In terms of energy dissipation capacity, the increase ranged from 40%–87% in the undamaged columns, while a significant increase of about 39% was only observed in one of the damaged columns. In the column of moderate concrete compressive strength (29 MPa), the technique was even much more effective, since, when compared to the maximum load and energy dissipation capacity of the corresponding strengthened column of 8 MPa of average compressive strength, it provided an increase of 39% and 109%, respectively, showing its appropriateness for RC columns of buildings requiring upgrading against seismic events.  相似文献   

19.
The U.S. Interstate 80 bridge over State Street in Salt Lake City is very near the Wasatch fault, which is active and capable of producing large earthquakes. The bridge was designed and built in 1965 according to the 1961 American Association of State Highway Officials specifications, which did not consider earthquake-induced forces or displacements. The bridge consists of reinforced concrete bents supporting steel plate welded girders. The bents are supported on cast-in-place concrete piles and pile caps. A seismic retrofit design was developed using carbon fiber reinforced polymer (CFRP) composites, which was implemented in the summer of 2000 and the summer of 2001, to improve the displacement ductility of the bridge. The seismic retrofit included column jacketing, as well as wrapping of the bent cap and bent cap-column joints for confinement, flexural, and shear strength increase. This paper describes the specifications developed for the CFRP composite column jackets and composite bent wrap. The specifications included provisions for materials, constructed thickness based on strength capacity, and an environmental durability reduction factor. Surface preparation, finish coat requirements, quality assurance provisions, which included sampling and testing, and constructability issues regarding the application of fiber composite materials in the retrofit of concrete bridges are also described.  相似文献   

20.
This paper focuses on an investigation of improved continuous longitudinal joint details for decked precast prestressed concrete girder bridge systems. Precast concrete girders with an integral deck that is cast and prestressed with the girder provide benefits of rapid construction along with improved structural performance and durability. Despite these advantages, use of this type of construction has been limited to isolated regions of the United States. One of the issues limiting more widespread use is a perceived problem with durability of longitudinal joints used to connect adjacent girders. This paper presents the results of a study to assess potential alternate joint details based on constructability, followed by testing of selected details. Seven reinforced concrete beam specimens connected with either lapped headed reinforcement or lapped welded wire reinforcement were tested along with a specimen reinforced by continuous bars for comparison. Test results were evaluated based on flexural capacity, curvature at failure, cracking, deflection, and steel strain. Based on the survey and the experimental program, a headed bar detail with a 152 mm (6 in.) lap length was recommended for replacing the current welded steel connector detail.  相似文献   