首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
中性束质子比的高低对其注入等离子体后的加热效果具有重要的影响。实验中,强流离子源的灯丝电压、弧压、进气量等宏观运行参数决定了中性束质子比的大小。以东方超环中性束注入测试台束引出实验为基础,利用多元线性回归模型对引出中性束质子比进行分析,建立了影响中性束质子比的预测方程,并对该模型的正确性进行了检验。结果表明,中性束质子比可利用以灯丝电压和弧压为自变量的多元线性回归模型进行分析,灯丝电压是影响质子比的关键参数,弧压次之。  相似文献   

2.
任春生  牟宗信  王友年 《核技术》2006,29(10):730-733
离子源技术是等离子体研究中的一项重要内容,而低能大束流源则是离子源技术研究中的一个重要方向,因为这样的源在离子束刻蚀、离子束溅射镀膜以及荷能粒子与物质相互作用方面都有广泛的应用;本文采用空心阴极空心阳极结构,用热阴极电子发射弧放电驱动并用磁场约束产生等离子体,用曲面发射引出离子束,研制成了氩气放电溅射离子源;研究了灯丝加热电流、弧压对弧流的影响和弧流与工作气体压力对离子束引出的影响规律.离子源的引出电压在0-4.0 kV之间连续可调,最大引出束流为100 mA,束斑面积为φ6.0 cm,以Ti为溅射靶时的最大溅射沉积率为0.45 nm/s,离子源可连续工作160 h.  相似文献   

3.
The difference of hot cathode operation mode has great influence on the arc discharge of high current ion source. Based on the analysis of the theory of hot filament with two operation modes and combined with ion source experiments, the paper studies the effects of hot filament operation modes on ion source arc discharge.  相似文献   

4.
大功率离子源是整个中性束注入装置的核心部件。离子源灯丝、弧等关键部件的运行状态对系统实验参数设定、故障判断至关重要。为了实时监控灯丝、弧的运行状态,设计了一款大功率离子源负载端数据采集系统。系统采用伏频(V/F)转换技术实现了采样信号的远程隔离传输。PXI系统和Lab VIEW将采样信号进行实时显示。实验结果表明,在直流和调制注入模式下,系统实现了离子源灯丝和弧电压的远程实时监控。  相似文献   

5.
High power ion source is one of the important parts of the neutral beam injection. It produces high energy beam by extracting and accelerating ions from its arc chamber. The hot cathode (filaments) in the arc chamber of the ion source operates in two modes. Operation mode of the cathode has great effect on the stable operation of the ion source. Based on the theory of hot cathode and experimental results, this paper presents the operation results (beam current, arc efficiency) of an ion source with various cathode temperatures (controlled by voltage applied to the cathode).  相似文献   

6.
Diagnostic Neutral Beam (DNB) has been used for measuring plasma parameters of tokamaks such as ion and electron temperature, safety factor, impurity concentration and etc. Ion source and electrical power supply specification are the main part of DNB. Arc discharge current value is affected by filament current and anode voltage. Beam current changes with arc current signal in our experiment that agree with theoretical relations. Sixty milli-ampere (60 mA) pulse beam current is because of arc current of about 40 A and extraction voltage of about 20 kV. The increase of beam current with arc current has been reported experimentally and effect of arc current on beam current has been investigated for several high extraction voltages. Optimum condition, which means having a telescopic beam (minimum divergence) for specific parameters of duoplasmatron, has been simulated and verified with experimental test. The best extraction voltage for these parameters has been found to be about 16-kV. The ratio of the perpendicular velocity to parallel velocity has been calculated to be about 0.012. It has been shown experimentally with optical emission spectroscopy that increase in arc current and magnetic current increase proton content of beam.  相似文献   

7.
为提高北京师范大学GIC4117型串列加速器358型双等离子体离子源束流强度及灯丝使用寿命,改进了离子源灯丝涂覆材料中Ba、Sr、Ca元素的占比、灯丝涂覆方法及离子源保护措施。讨论了在不同灯丝电流下,进气量、弧流、约束磁铁电流对离子源输出束流强度的影响。灯丝累积使用寿命达到200 h以上,靶室束流强度较原来采用860A溅射源提高约500倍。同时本文对358型双等离子体离子源调试过程中的异常断弧情况进行了分析和改进。  相似文献   

8.
A hot cathode bucket ion source is used for the EAST(experimental advanced superconducting tokamak)neutral beam injector.The thermal electrons emitted from the surface of the cathode are extracted and accelerated by the electric field formed by the arc voltage,which is applied between the arc chamber of the ion source and the cathode.This paper analyzes the effects of arc voltage on the arc discharge in a hot cathode high current ion source.  相似文献   

9.
A novel construction of an ion source with an evaporator placed inside a plasma chamber is presented. The crucible is heated to high temperatures directly by arc discharge, which makes the ion source suitable for substances with high melting points. The compact ion source enables production of intense ion beams for wide spectrum of solid elements with typical separated beam currents of ∼100-150 μA for Al+, Mn+, As+ (which corresponds to emission current densities of 15-25 mA/cm2) for the extraction voltage of 25 kV. The ion source works for approximately 50-70 h at 100% duty cycle, which enables high ion dose implantation. The typical power consumption of the ion source is 350-400 W. The paper presents detailed experimental data (e.g. dependences of ion currents and anode voltages on discharge and filament currents and magnetic flux densities) for Cr, Fe, Al, As, Mn and In. The discussion is supported by results of Monte Carlo method based numerical simulation of ionisation in the ion source.  相似文献   

10.
For the generation of heavy ions at high charge states, the cold-cathode Penning discharge ion source requires a power supply capable of both the high potential essential for striking an arc and the high current for sustaining it. A series-regulated power supply developed at Oak Ridge provides up to 6 kV of striking voltage and up to 12 amperes of arc current. The power supply operates in a constant current mode with the arc voltage dependent on the gas pressure in the ion source. With this source in ORIC, the typical operating conditions are 5 to 10 amperes arc current, 600 to 2000 volts arc potential, and 5 to 20 kW power dissipation in the arc. A larger power supply is planned for extending the arc current to about 25 amperes. Various arrangements, including pre-regulators and multiple power supplies, are under consideration to reduce power dissipation in the series regulator tubes.  相似文献   

11.
A neutral beam injector (NBI) test stand was constructed to develop a multi-megawatt prototype ion source as an auxiliary heating system on experimental advanced superconducting tokamak. A power supply system for the NBI test stand components such as a set of dc power supplies for plasma generator, a dc high voltage power supply of a tetrode accelerator, a transmission line and a surge energy suppressor. Stable arc discharges of the plasma generator with hydrogen gases for 100 s long pulse have been produced by six Langmuir probes feedback loop regulation mode to control the arc power supply. The 4 MW hydrogen ion beam of 1 s is extracted with beam energy of 80 keV and the beam current of 52 A. The dc high voltage power supply for the plasma grid of the prototype ion source was designed to contribute maximum voltage of 100 kV and current of 100 A. The high voltage power output is continuously adjustable to satisfy with plasma physics experiment in operation frequency of 10 Hz. To prevent damage of the beam source at high voltage breakdown, core snubber using deltamax soft magnetic materials have been adopted to satisfy the input energy into the accelerator from the power supply can be reduced to about 5 J in the case of breakdown at 80 kV. For the transmission line, a disc shape multi cable coaxial configuration was adopted and which the dimension of the diameter is 140 mm at the core snubber. The major issues of discharge characteristics with long pulse and beam extraction with high power for the prototype ion source were investigated on the NBI test stand.  相似文献   

12.
针对22cm双潘宁离子源,研究了其弧流与放电调节参数的关系以及二次进气的效果,确定了拉长弧流脉宽、提高弧流强度与稳定性、达成离子源合适工作状态的措施,为获得高品质的弧流提供了依据.离子源弧特性测试研究结果对提高强流离子源的工作性能以实现NBI系统强流准稳态运行有重要的指导意义.  相似文献   

13.
14.
强流离子源是HL-2M装置5 MW中性束注入加热系统的核心部件,离子源通过弧电源加速初级电子至高能态,碰撞气体分子,产生等离子体。所以,弧电源对于离子源维持稳定的弧放电非常重要。本文利用Saber软件建立了弧电源的主电路模型,设计并仿真了弧电流的恒流控制、打坑控制以及超级电容的恒流充电控制、恒功率放电控制等。这种方法不仅提高了弧电源电路的分析和设计效率,缩短了系统研制的周期,还可用于实际系统的故障分析和控制参数的整定,降低实验风险。实验结果表明,弧电源的真实输出与仿真输出结果相符。  相似文献   

15.
The first campaign of ion beam extraction tests are completed for EAST NBI high current ion source. The hydrogen ion beam with beam voltage of 80 keV is extracted from tetrode accelerator system. During the experiment, the characteristics of arc discharge and ion beam extraction are studied. The arc power reaches 120 kW and the extracted ion beam power reaches 3 MW. The relationship of some key parameters of arc and beam are investigated, and the details are described in this paper.  相似文献   

16.
强流脉冲束功率的测量   总被引:1,自引:0,他引:1  
余增亮 《核技术》1989,12(4):205-208
  相似文献   

17.
18.
The neutral beam injector (NBI) is one of the main plasma heating methods for nuclear fusion devices. For the hot cathode high current ion source, the arc current and beam current tends to increase during the beam pulse. In order to gets long pulse beam extraction, the arc regulation technology is employed. The Langmuir probes are installed on the experimental advanced superconducting tokamak-NBI ion source, to feedback control the arc discharge and beam extraction. The experimental results show that, the long pulse of 100 s ion beam is extracted with beam energy of 30 keV with arc regulation. More the results are presented in this paper.  相似文献   

19.
EAST强流离子源电源系统的初步测试运行   总被引:1,自引:0,他引:1  
测试NBI大功率强流离子源的综合测试台正在建设,已研制了离子源等离子体发生器电源系统、等离子体电极高压电源及梯度极分压器、抑制极负高压电源等电源系统,以及高压传输线及缓冲器,在测试台上开展了对EAST中性束注入器第一台兆瓦级强流离子源样机进行整体电源系统测试和离子源起弧放电的初步测试,完成了离子源电源系统初步性能测试及...  相似文献   

20.
A survey on questions related to the production of multiply charged ions with the Duoplasmatron ion source is given. In spite of differences of the multiply charged ion source and the mass separator type, design considerations show that high containment is a common feature to be attained in both subjects. Multiply charged metal ions are produced by material evaporation into the magnetically confined anodic plasma and auxiliary gas feed into the cathode discharge regions. Energy spreads of ion beams from the low and the high arc current source are compared. The Duoplasmatron ion source proves to be a hygieneous source of high containment that permits the production of medium charge states up to 9+ for xenon at modest energy spread and good brilliance of the extracted ion beam in a high current-low voltage discharge mode.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号