1.
We describe the construction and application of a 9.4-T FT-ICR mass spectrometer interfaced to a commercial field desorption ion source for high-resolution, high-mass accuracy measurements of nonpolar species. The FT-ICR MS instrument includes a liquid injection field desorption ionization source, octopole ion guides, external octopole ion trap capable of an axial potential gradient for ion ejection, capacitively coupled open cylindrical ion trap, and pulsed gas valve for ion cooling. Model compound responses with regard to various source and instrument conditions provide a basis for interpretation of broadband mass spectra of complex mixtures. As an example, we demonstrate broadband speciation of a Gulf Coast crude oil, with respect to numerous heteroatomic classes, compound types (rings plus double bonds), and carbon number distributions.  相似文献   

2.
We report the use of desorption electrospray ionization hybrid Fourier transform ion cyclotron resonance mass spectrometry (DESI-FT-ICR-MS) for the analysis of carbohydrates. Spectra of neat carbohydrates are presented along with their mass measurement accuracies and limits of detection. Furthermore, a comparison is made between the analyses of O-linked glycans from mucin by DESI-FT-ICR-MS and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry. Finally, glycans from mucin are identified by using the high mass measurement accuracy and tandem MS capabilities afforded by the hybrid FT-ICR-MS platform.  相似文献   

3.
Laser-induced acoustic desorption (LIAD) coupled with a 3-T Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR) allows the simultaneous analysis of both the nonpolar and polar components in petroleum distillates. The LIAD/FT-ICR method was validated by examining model compounds representative of the various classes of polar and nonpolar hydrocarbons commonly found in petroleum. LIAD successfully desorbs all the compounds as intact neutral molecules into the FT-ICR. Electron ionization (EI) at low energies (10 eV) and chemical ionization using cyclopentadienyl cobalt radical cation (CpCo*+) were employed to ionize the desorbed molecules. The EI experiments lead to extensive fragmentation of many of the hydrocarbon compounds studied. However, the CpCo*+ ion ionizes all the hydrocarbon compounds by producing only pseudomolecular ions without other fragmentation, with the exception of one compound (*CH3 loss occurs). Examination of two different petroleum distillate samples revealed hundreds of compounds. The most abundant components have an even molecular weight; i.e., they are likely to contain no (or possibly an even number of) nitrogen atoms.  相似文献   

4.
We describe automation of liquid injection field desorption/ionization (LIFDI) for reproducible sample application, improved spectral quality, and high-throughput analyses. A commercial autosampler provides reproducible and unattended sample application. A custom-built field desorption (FD) controller allows data station or front panel control of source parameters including high-voltage limit/ramp rate, emitter heating current limit/ramp rate, and feedback control of emitter heating current based on ion current measurement. Automated LIFDI facilitates ensemble averaging of hundreds of Fourier transform ion cyclotron resonance mass spectra for increased dynamic range, mass accuracy, and S/N ratio relative to single-application FD experiments, as shown here for a South American crude oil. This configuration can be adapted to any mass spectrometer with an LIFDI probe.  相似文献   

5.
We present a novel nonresonant laser-based matrix-free atmospheric pressure ionization technique, atmospheric pressure laser-induced acoustic desorption chemical ionization (AP/LIAD-CI). The technique decouples analyte desorption from subsequent ionization by reagent ions generated from a corona discharge initiated in ambient air or in the presence of vaporized toluene as a CI dopant at room temperature. Analyte desorption is initiated by a shock wave induced in a titanium foil coated with electrosprayed sample, irradiated from the rear side by high-energy laser pulses. The technique enables facile and independent optimization of the analyte desorption, ionization, and sampling events, for coupling to any mass analyzer with an AP interface. Moreover, the generated analyte ions are efficiently thermalized by collisions with atmospheric gases, thereby reducing fragmentation. We have coupled AP/LIAD-CI to ultrahigh-resolution FT-ICR MS to generate predominantly [M + H](+) or M(+?) ions to resolve and identify thousands of elemental compositions from organic mixtures as complex as petroleum crude oil distillates. Finally, we have optimized the AP/LIAD CI process and investigated ionization mechanisms by systematic variation of placement of the sample, placement of the corona discharge needle, discharge current, gas flow rate, and inclusion of toluene as a dopant.  相似文献   

6.
Intermediate pressure matrix-assisted laser desorption/ionization (MALDI) source was constructed and interfaced with a 6-T Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially configured for surface-induced dissociation (SID) studies. First MALDI-SID results in FT-ICR are presented, demonstrating unique advantages of SID over conventional FT-ICR MS ion activation techniques for structural characterization of singly protonated peptide ions. Specifically, we demonstrate that SID on a diamond surface results in a significantly better sequence coverage for singly protonated peptides than SORI-CID. A combination of two effects contributes to the improved sequence coverage: shattering of peptide ions on surfaces opens up a variety of dissociation channels at collision energies above 40 eV, and second, wide internal energy distribution deposited by collision with a stiff diamond surface provides an efficient mixing between the primary reaction channels that are dominant at low internal energies and extensive fragmentation at high internal excitation that results from shattering. Activation of MALDI-generated ions by collisions with surfaces in FT-ICR MS is a new powerful method for characterization and identification of biomolecules  相似文献   

7.
The advent of ultra-high-resolution mass spectrometry has revolutionized the ability of aquatic biogeochemists to examine molecular-level components of complex mixtures of organic matter. The ability to accurately assess the chemical composition, elemental formulas, or both of detected compounds is critical to these studies. Here we build on previous work that uses functional group relationships between compounds to extend elemental formulas of low molecular weight compounds to those of higher molecular weight. We propose an automated compound identification algorithm (CIA) for the analysis of ultra-high-resolution mass spectra of natural organic matter acquired by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. This approach is benchmarked with synthetic data sets of compounds cited in the literature. The sensitivity of our results is examined for different sources of error, and CIA is applied to two previously published data sets. We find that CIA works well for data sets with high mass accuracy (<1 ppm) and can accurately determine the elemental formulas for >95% of all compounds composed of C, H, O, and N. Data with lower mass accuracy must be accompanied with additional knowledge of chemical structure, composition, or both in order to yield accurate elemental formulas.  相似文献   

8.
The ultrahigh resolution and sensitivity of electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry have for the first time been exploited for the characterization of highly sialylated glycoproteins, using human alpha-1-acid glycoprotein as the model compound. An alternative approach to the widely used high-performance liquid chromatography (HPLC) and matrix-assisted laser desorption/ionization (MALDI) assays is described. This new method does not require any enzymatic or chemical digestion (removal of sialyl groups or deglycosylation), chemical derivatization (introduction of chromophore groups), or preliminary chromatographic separation (HPLC or electrophoresis). Following ESI and accumulation of ions in a hexapole ion guide, ions are injected into the ICR cell. A selected mass window from the overall ion population is isolated and axialized prior to detection. After acquisition and Fourier transform of the transient signal the resulted spectrum is evaluated in order to determine the charge state of the detected ions and the isotope pattern of the measured protein glycoform. The presence of ions from the same glycoform with different charge states was confirmed. The advantages and limitations of the technique are discussed. Future prospects and possible applications are indicated.  相似文献   

9.
A new mass spectrometric method has been developed for the analysis of low molecular weight polyethylene (PE). Laser-induced acoustic desorption (LIAD), combined with chemical ionization by the cyclopentadienyl cobalt radical cation (CpCo.+) in a Fourier transform ion cyclotron resonance mass spectrometer, produces predominantly a quasimolecular ion, (R + CpCo - 2H2).+, for each PE oligomer (R). An examination of artificial alkane mixtures revealed no mass bias for alkanes of differing molecular weights. However, the success of the LIAD/CpCo.+ CI technique depends greatly upon the LIAD sample preparation method used. Several sample preparation methods were evaluated, and pneumatically assisted spin coating was concluded to provide the best mass spectra as a result of its ability to provide uniform PE coverage on the LIAD foils. The molecular weight distributions measured for several low molecular weight PE samples (200-655) were found to be in good agreement with manufacturers' values as determined by gel permeation chromatography.  相似文献   

10.
Fourier transform ion cyclotron resonance laser microprobe mass spectrometry (FTICR LMMS) uses focused laser irradiation of solids with a spot of 5 microm and a FTICR mass analyzer for local analysis with high mass resolution. A new ion source design has been developed to improve the extraction and transfer of ions generated in an external laser microprobe source. Calculations predicted trapping of ions initially emitted with angles up to 40 degrees and 60 degrees from the surface and from a distance of 1 mm above the sample, respectively. The analytical performances of the method have been verified on two sets of test samples. First, detection of chemisorbed benzotriazole on copper, average of two monolayers, has been shown with less sample consumption than typically required in static secondary ion mass spectrometry with a time-of-flight analyzer. Second, experiments on a thermal plate for offset printing have shown the feasibility of analysis and quantification of dyes embedded in a polymer matrix.  相似文献   

11.
Inulin is a class of fructooligosaccharide (FOS) derived from plants, which is often used as a natural food ingredient. Inulin is currently used as an additive in baked goods, dairy products, infant formula, and dietary supplements as a result of its purported health-promoting properties. The growth of health-promoting lactobacilli and bifidobacteria is supported by FOS, giving it the classification of a prebiotic; however, its ability to selectivity stimulate only beneficial bacteria has not been demonstrated. In order to better understand the role of inulin and FOS as prebiotics, matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry has been used for qualitative and quantitative analysis on bacterial growth. A method using an internal standard has been developed to quantify the consumption of FOS by Bifidobacterium longum bv. infantis using a calibration curve. Due to the differential consumption of FOS, the calibration curve was modified to include intensity components for each polymer unit in order to achieve more accurate quantitation. The method described was designed to be more rapid, precise, and robust for quantitative analysis when compared to existing methods.  相似文献   

12.
We have coupled atmospheric pressure photoionization (APPI) to a home-built 9.4-T Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Analysis of naphtho[2,3-a]pyrene and crude oil mass spectra reveals that protonated molecules, deprotonated molecules, and radical molecular ions are formed simultaneously in the ion source, thereby complicating the spectra (>12 000 peaks per mass spectrum and up to 63 peaks of the same nominal mass), and eliminating the "nitrogen rule" for nominal mass determination of number of nitrogens. Nevertheless, the ultrahigh mass resolving power and mass accuracy of FT-ICR MS enable definitive elemental composition assignments, even for doublets as closely spaced as 1.1 mDa (SH3(13)C vs (12)C4). APPI efficiently ionizes nonpolar compounds that are unobservable by electrospray and allows nonpolar sulfur speciation of petrochemical mixtures.  相似文献   

13.
Consecutive infrared multiphoton dissociations (IRMPD) may be observed in a Fourier transform ion cyclotron resonance mass spectrometer (FTICR). This is the IRMPD equivalent of previous MS(n)() experiments using CID. This work presents a versatile technique, using a bistable shutter to gate ON and OFF a continuous-wave (CW) CO(2) laser for multiple irradiation periods of 0.1-1000 s duration. Consecutive photodissociations, up to MS(4), are demonstrated for the proton-bound dimer of diethyl ether and the resulting fragment ions. The photoproducts are formed close to the center of the FTICR cell, resulting in high product ion recovery efficiency. This differs from CID products, which are formed throughout the FTICR cell causing reisolation/detection problems. The fragmentation resulting from the use of low-intensity, CW, infrared laser radiation is shown to be much more energy selective than CID. Photodissociation of C(2)H(5)OH(2)(+) ion produces the lowest energy product ion exclusively, even though the two product channels differ only by ~5 kcal/mol. Low-energy CID, however, produces a mixture of C(2)H(5)(+) and H(3)O(+) products in the ratio of 1.3:1. Hence, the higher energy pathway (C(2)H(5)(+)) is substantially favored. The current results indicate that this IRMPD MS(n)() technique may be successfully applied to large biomolecules prepared by electrospray or MALDI.  相似文献   

14.
Laser-induced acoustic desorption (LIAD), combined with chemical ionization with the ClMn(H(2)O)(+) ion, is demonstrated to facilitate the analysis of base oils by Fourier transform ion cyclotron resonance mass spectrometry. The LIAD/ClMn(H(2)O)(+) method produces only one product ion, [ClMn + M](+), for each component (M) in base oils, thus providing molecular weight (MW) information for the analytes. With the exception of one sample, no fragmentation was observed. The mass spectra indicate the presence of homologous series of ions differing in mass by multiples of 14 Da (i.e., CH(2)). All peaks in the spectra correspond to ions with even m/z values and hence are formed from hydrocarbons with no nitrogen atoms, in agreement with the compositional nature of base oils. The MW distributions measured for two groups of base oil samples cover the range 350-600 Da, which is in excellent agreement with the values determined by gas chromatography. Moreover, the hydrocarbon types (i.e., paraffin and cycloparaffins with different numbers of rings) present in each base oil sample can be determined based on the m/z values of the product ions. Finally, the results obtained by using LIAD/ClMn(H(2)O)(+) indicate that the efficiency of the technique (combined desorption and ionization efficiency) is similar for different hydrocarbon types and fairly uniform over a wide molecular weight range, thus allowing quantitative analysis of the base oils. Hence, the product ions' relative abundances were used to determine the percentage of each type of hydrocarbon in the base oil. In summary, three important parameters (MW distributions, hydrocarbon types, and their relative concentrations) can be obtained in a single experiment. This mass spectrometric technique therefore provides detailed molecular-level information for base oils, which cannot be obtained by other analytical methods.  相似文献   

15.
Electron detachment dissociation (EDD), recently introduced by Zubarev and co-workers for the dissociation of multiply charged biomolecular anions via a radical ion intermediate, has been shown to be analogous to electron capture dissociation (ECD) in several respects, including more random peptide fragmentation and retention of labile posttranslational modifications. We have previously demonstrated unique fragmentation behavior in ECD compared to vibrational excitation for oligodeoxynucleotide cations. However, that approach is limited by the poor sensitivity for oligonucleotide ionization in positive ion mode. Here, we show implementation of EDD on a commercial Fourier transform ion cyclotron resonance mass spectrometer utilizing two different configurations: a heated filament electron source and an indirectly heated hollow dispenser cathode electron source. The dispenser cathode configuration provides higher EDD efficiency and additional fragmentation channels for hexamer oligodeoxynucleotides. As in ECD, even-electron d/w ion series dominate the spectra, but we also detect numerous a/z (both even-electron and radical species), (a/z - B), c/x, (c/x - B), and (d/w - B) ions with minimal nucleobase loss from the precursor ions. In contrast to previous high-energy collision-activated dissociation (CAD) and ion trap CAD of radical oligonucleotide anions, we only observe minimum sugar cross-ring cleavage, possibly due to the short time scale of EDD, which limits secondary fragmentation. Thus, EDD provides fragmentation similar to ECD for oligodeoxynucleotides but at enhanced sensitivity. Finally, we show that noncovalent bonding in a DNA duplex can be preserved following EDD, illustrating another analogy with ECD. We believe the latter finding implies EDD has promise for characterization of nucleic acid structure and folding.  相似文献   

16.
Here we describe a new quadrupole Fourier transform ion cyclotron resonance hybrid mass spectrometer equipped with an intermediate-pressure MALDI ion source and demonstrate its suitability for "bottom-up" proteomics. The integration of a high-speed MALDI sample stage, a quadrupole analyzer, and a FT-ICR mass spectrometer together with a novel software user interface allows this instrument to perform high-throughput proteomics experiments. A set of linearly encoded stages allows sub-second positioning of any location on a microtiter-sized target with up to 1536 samples with micrometer precision in the source focus of the ion optics. Such precise control enables internal calibration for high mass accuracy MS and MS/MS spectra using separate calibrant and analyte regions on the target plate, avoiding ion suppression effects that would result from the spiking of calibrants into the sample. An elongated open cylindrical analyzer cell with trap plates allows trapping of ions from 1000 to 5000 m/z without notable mass discrimination. The instrument is highly sensitive, detecting less than 50 amol of angiotensin II and neurotensin in a microLC MALDI MS run under standard experimental conditions. The automated tandem MS of a reversed-phase separated bovine serum albumin digest demonstrated a successful identification for 27 peptides covering 45% of the sequence. An automated tandem MS experiment of a reversed-phase separated yeast cytosolic protein digest resulted in 226 identified peptides corresponding to 111 different proteins from 799 MS/MS attempts. The benefits of accurate mass measurements for data validation for such experiments are discussed.  相似文献   

17.
The Hartley transform offers a useful alternative to the Fourier transform for the conversion of a time-domain ion cyclotron resonance (ICR) signal into its corresponding frequency-domain mass spectrum. The Hartley transform has the advantage that it eliminates the need for complex variables, when (as for linearly polarized signals) the time-domain signal can be represented by a mathematically real function. Moreover, the Hartley transform produces the same spectra (absorption mode, dispersion mode, magnitude mode) as does the Fourier transform. In particular, the discrete fast Hartley transform (FHT) produces the same spectrum at twice the speed of a complex fast Fourier transform (FFT), making the FHT equivalent in speed to a "real" FFT. Hartley and Fourier transform methods in ICR mass spectrometry are compared and demonstrated experimentally. Essentially the same advantages and computational methods should apply to the use of the Hartley transform in place of the Fourier transform in other forms of spectrometry (e.g., nuclear magnetic resonance, infrared, etc.).  相似文献   

18.
Subfemtomole peptide sequence analysis has been achieved using microcapillary HPLC columns, with integrated nanoelectrospray emitters, coupled directly to a Fourier transform ion cyclotron resonance mass spectrometer. Accurate mass (+/-0.010 Da) peptide maps are generated from a standard six-protein digest mixture, whose principle components span a concentration dynamic range of 1000:1. Iterative searches against approximately 189000 entries in the OWL database readily identify each protein, with high sequence coverage (20-60%), from as little as 10 amol loaded on-column. In addition, a simple variable-flow HPLC apparatus provides for on-line tandem mass spectrometric analysis of tryptic peptides at the 400-amol level. MS/MS data are searched against approximately 280000 entries in a nonredundant protein database using SEQUEST. Accurate precursor and product ion mass information readily identifies primary amino acid sequences differing by asparagine vs aspartic acid (deltam = 0.98 Da) and glutamine vs lysine (deltam = 0.036 Da).  相似文献   

19.
We report here the construction and characterization of a high-power laser-induced acoustic desorption (LIAD) probe designed for Fourier transform ion cyclotron resonance mass spectrometers to facilitate analysis of nonvolatile, thermally labile compounds. This "next generation" LIAD probe offers significant improvements in sensitivity and desorption efficiency for analytes with larger molecular weights via the use of higher laser irradiances. Unlike the previous probes which utilized a power-limiting optical fiber to transmit the laser pulses through the probe, this probe employs a set of mirrors and a focusing lens. At the end of the probe, the energy from the laser pulses propagates through a thin metal foil as an acoustic wave, resulting in desorption of neutral molecules from the opposite side of the foil. Following desorption, the molecules can be ionized by electron impact or chemical ionization. Almost an order of magnitude greater power density (up to 5.0x10(9) W/cm2) is achievable on the backside of the foil with the high-power LIAD probe compared to the earlier LIAD probes (maximum power density approximately 9.0x10(8) W/cm2). The use of higher laser irradiances is demonstrated not to cause fragmentation of the analyte. The use of higher laser irradiances increases sensitivity since it results in the evaporation of a greater number of molecules per laser pulse. Measurement of the average velocities of LIAD-evaporated molecules demonstrates that higher laser irradiances do not correlate with higher velocities of the gaseous analyte molecules.  相似文献   

20.
Laser-induced acoustic desorption (LIAD), combined with chemical ionization by the cyclopentadienyl cobalt radical cation (CpCo.+), is demonstrated to facilitate the analysis of saturated hydrocarbons by Fourier transform ion cyclotron resonance mass spectrometry. The LIAD/CpCo.+ method produces unique pseudomolecular ions for alkanes from C(24)H(50) to C(50)H(102). These alkanes were tested individually and in artificial mixtures of up to seven components. Only one product ion, [R + CpCo - 2H(2)].+, was detected for each alkane (R). The product ions' relative abundances correspond to the relative molar concentration of each alkane in mixtures. These findings provide a solid groundwork for the future application of this method for hydrocarbon polymer analyses.  相似文献   