首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 0 毫秒
1.
Earlier studies conducted in the use of sealed tubes with polyalkylene glycol lubricants and polyethylene terephthalete (PET) films revealed that the PET films exhibited embrittlement and (visual) degradation. This led to an investigation of PET embrittlement mechanisms with the new lubricants used with HFC 134a. The lubricants studied were three polypropylene glycols (the monol, the diol and the completely end-capped glycols), pentaerythritol ester and a blend of monol and ester. The effects of moisture content, temperature and lubricant structure were studied. All lubricants in this study were of viscosity grade ISO-32 (150 SUS). The results were compared to PET film embrittlement in the presence of CFC 12 and mineral oil. This study reconfirmed the earlier findings that the PET films must be dried to lower than 0.1 wt.% moisture content for use in hermetic systems. This paper discusses the effect of the moisture content of the lubricant and the effect of the lubricant structure on PET films. The dependence of the various mechanisms on temperature is shown. Esters and end-capped polyalkylene glycols are recommended for use with HFC 134a.  相似文献   

2.
Five commercially available spacers were investigated to determine their influence on the percentage of drug retained in the spacer device, percentage fine particle fraction (FPF), percentage deposited in the induction port, mass median aerodynamic diameter (MMAD), and geometric standard deviation (GSD). Betamethasone valerate (BMV) and triamcinolone acetonide (TAA) were used as model drugs in the pressurized metered dose inhaler (pMDI) formulations containing the propellant HFA 134a. The BMV was dissolved in an ethanol/HFA 134a system, and the TAA was suspended in HFA 134a using ethanol as a dispersing agent. The metering chamber volume of the valve was either 50 microl or 150 microl. The spacer devices investigated included the ACE, Aerochamber, Azmacort, Easivent, and Ellipse spacers. Each spacer device was attached to an Andersen Cascade Impactor powered by a vacuum pump. Cascade impaction data were used to derive the percentage drug deposited in the induction port, MMAD, GSD, and FPF. The BMV particles emitted from the spacers were finer than the TAA particles because the dissolved drug precipitated as the cosolvent evaporated. The TAA particles had significantly larger MMADs because many undissolved drug particles were contained within each droplet following actuation. After evaporation of the liquid continuous phase, the suspended drug aggregated to form larger agglomerates than those particles precipitated from the BMV pMDI solution droplets. The addition of a spacer device lowered the MMAD to less than 4.7 microm for particles from both the BMV pMDI solution and the TAA pMDI suspension. The addition of a spacer device also lowered the percentage drug deposited in the induction port. The FPF was significantly increased when a spacer device was used. The MMAD significantly decreased when a spacer device was added for the two model drugs when using the 150-microl metering valves, but the difference was not statistically significant when the 50-microl valves were used (P < .05). The GSD was not influenced by the use of a spacer device. The use of a spacer device will enhance pMDI therapy by reducing the amount of drug deposited in the oropharyngeal region, which will lead to fewer instances of local and systemic side effects. In addition, the spacer devices investigated will allow a higher dose of drug to reach the deep lung, which may permit the use of lower dosage regimens with increased therapeutic efficacy.  相似文献   

3.
本文建立了以R134a为冷却工质的封闭式喷雾冷却系统,研究了工质过冷度、质量流量和热流密度对喷雾冷却系统换热性能的影响。其中,工质过冷度由喷嘴入口前的过冷段控制,质量流量通过变频齿轮泵调节,热流密度通过改变加热电源电压和电流控制。实验结果表明,在热流密度和质量流量保持不变时,改变过冷度对热源表面温度和换热系数的影响并不明显;在热流密度和过冷度保持不变的条件下,系统存在一个临界质量流量值,在质量流量达到临界值之前,热源表面温度随质量流量的增大而降低,当质量流量高于临界值时,热源表面温度随质量流量的增大而升高;当质量流量和过冷度保持不变时,存在一个热流密度使液滴的蒸发量等于补充量,在此热流密度下热源表面系数能达到最大。  相似文献   

4.
At present hydrofluorocarbons (HFCs) such as R32, R-125, R-134a, and R-143a are widely used, and it is required to obtain accurate information of thermophysical properties, especially of the thermal conductivity of HFCs. In this paper new thermal conductivity equations for R-32, R-125, R134a, and R143a are proposed, applicable over a wide range of temperature and pressure including the critical region based on existing experimental data, and the reliability of the present equations is summarized. The problem that the thermal conductivity calculated from the thermal diffusivity in the critical region differs depending on the equation of state is also discussed. Paper presented at the Sixteenth European Conference for Thermophysical Properties, September 1–4, 2002, London, United Kingdom.  相似文献   

5.
Refrigerant R134a (1,1.1,2-tetrafuoroethane) is a leading substitute for refrigerant R12. As such, there has been worldwide activity to develop accurate wide-range equations of state for this fluid. In this study. we have developed a new selection algorithm for determining high-accuracy equations of state in the Helmholtz representation. This method combines least-squares regression analysis with simulated annealing optimization. Simulated annealing, unlike stepwise regression, allows for the controlled acceptance of random increases in the objective function. Thus, this procedure produces a computationally efficient selection algorithm which is not susceptible to the function-space local-minima problems present in a purely stepwise regression approach. Two equations are presented in this work and compared against experimental data and other high-accuracy equations of state for R134a. One equation was produced strictly by using stepwise a regression algorithm, while the other was produced using the simulated-annealing selection algorithm. In both cases the temperature dependence of the equations was restricted to have no terms whose exponents were greater than live.Paper presented at the Twelfth Symposium on Thermophysical Properties. June 19–24, 1994, Boulder, Colorado, U.S.A.  相似文献   

6.
Measurements of the thermal conductivity of HFC-134a made in a coaxial cylinder cell operating in steady state are reported. The measurements of the thermal conductivity of HFC-134a were performed along several quasi-isotherms between 300 and 530 K in the gas phase and the liquid phase. The pressure ranged from 0.1 to 50 MPa. Based on the experimental data, a background equation is provided to calculate the thermal conductivity outside the critical region as a function of temperature and pressure. A careful analysis of the various sources of errors leads to an estimated uncertainty of ±1.5%.  相似文献   

7.
We describe the design and operation of a new high-pressure metal ebulliometer which can operate at pressures to at least 3 MPa in the range 220–400 K. Infinite-dilution activity coefficients are presented for the system CHF2Cl + CF3-CH, at 275 K and for the system CF3-CH2F + CH2F2, at 260, 230, and 300 K. The Wilson activity coellicient model and a virial coefficient model are applied to these systems, and the phase equilibrium conditions are calculated. The results are shown to agree well with predicted and with published measured values. The excess enthalpy is calculated and compared with results from a Peng Robinson equation of state. Vapor densities on the dew curves are given.  相似文献   

8.
For certain patients who experience intense vertigo arising from unilateral vestibular lesions, the primary therapy is a vestibular nerve section, an intracranial surgical procedure. One alternative to this treatment is therapeutic ablation of vestibular function on the unaffected side using an ototoxic agent. We prepared a biodegradable sustained-release gel delivery system using sodium hyaluronate that can be administered into the middle ear using only a local anesthetic. The gel contains gentamycin sulfate, the ototoxic agent of choice for treatment of unilateral vestibulopathy, and it exhibits diffusion-controlled release of the drug over a period of hours. The released gentamycin could then diffuse into the inner ear through the round membrane. This represents an important advance over previous formulations, which used only gentamycin sulfate solutions, in that it should allow more careful control of the dose, it should reduce loss of the drug from the middle ear site, and it should maintain intimate contact with the round membrane. By carefully controlling the dose, it should be possible to inhibit vestibular function while minimizing hearing loss. Herein we describe the in vitro release kinetics of gentamycin sulfate from sodium hyaluronate gels and find that the system obeys Fickian behavior.  相似文献   

9.
This paper is a review of some of our recent work on the effect of wall heating on the stability of laminar flow in a channel. The summary of our results, some of them unexpected, is as follows. Viscosity stratification has very little effect on transient growth, whereas it results in linear mode stabilising or destabilising by an order of magnitude. It has hitherto been accepted that heat diffusivity does not affect stability. This is however true only for linear instability, transient growth is affected by an order of magnitude. Unusually, the growth is spanwise-independent and not in the form of streamwise vortices. It is also shown that flow is destabilised by secondary modes as the viscosity ratio increases. However, the viscosity ratio has no role in the selection of the pattern of Λ vortices.  相似文献   

10.
The solution of the problem of reconstructing an image of the cross-section of an object with a limited set of data is considered. A program developed on the basis of the ART3 algebraic algorithm for reconstruction of tomograms is described. Results from a computational experiment are presented; in the course of the experiment the precision of a two-dimensional tomographic reconstruction as a function of the range of angles and number of projections obtained for models of cells with and without a nucleus is studied. __________ Translated from Izmeritel'naya Tekhnika, No. 8, pp. 34–37, August, 2005.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号