1.
STATEMENT OF PROBLEM: Flexible die materials have been introduced to facilitate the fabrication of indirect provisional or definitive restorations in 1 appointment. PURPOSE: This study compared the surface detail reproduction of 7 potential flexible die materials when used in combination with 7 elastomeric impression materials. METHODS: Surface detail reproduction of 17 impression material/flexible die material systems was compared with a control system containing an elastomeric impression material and a Type IV dental stone. Test dies of each system were prepared in a random order with the American Dental Association apparatus for testing detail reproduction, compatibility, and dimensional stability. RESULTS: One flexible die system had better surface detail reproduction than the control stone die, other systems had similar or worse reproduction. Surface detail reproduction was adversely affected when a separator was required between the impression and flexible die material. CONCLUSIONS: Impregum F die material with Extrude Light impression material produced better surface detail reproduction than the control dies. Impregum F impressions were incompatible with Blu-Mousse, Impregum F, or Imprint die materials. Polyvinyl siloxane impressions were incompatible with polyvinyl siloxane dies unless a separator was used. When a separator was used, the surface detail reproduction was not as good as the control die system or the Extrude Light impression material/Impregum F die material combination.  相似文献   

2.
The dimensional accuracy, surface hardness and reproduction of surface detail of stone casts produced from alginate impressions treated with 4.65% sodium hypochlorite, were investigated. To test dimensional accuracy, a Reflex Microscope was used to compare casts from 10 untreated impressions with casts from 10 impressions immersed in the solution for 30 mins. Surface detail and hardness were investigated on casts produced from impressions of a master stainless steel plate with 10 micro-indentations of increasing size. Surface detail of the casts were assessed by observation and surface hardness by a Vickers Hardness Machine. The dimensional accuracy test showed no significant differences between the experimental and control groups. Surface detail was unaffected after immersion of up to 10 mins. Surface hardness decreased linearly with respect to immersion time, when this was greater than 5 mins.  相似文献   

3.
OBJECTIVES: Surface activation of silicone impression materials enhances impression accuracy as well as the quality of stone casts. This study examined the relation between impression quality and the hydrophilicity of silicone impression materials used in a two-stage putty and wash technique. METHODS: The study included 14 silicone impression materials with and without surface activation. The contact angles of the light body materials were measured using deionised water. Free surface energies were calculated. A total of 140 impressions of wet intact permanent molar teeth were examined for definition of the gingival sulcus reproduction and then classified in a quality ranking. The percentage of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned resin casts from the impressions and clinically measured sulcus depths. RESULTS: Free surface energies (mJ/m2) of hydrophobic materials (contact angle > 90 degrees) ranged from 16.8 to 26.8 mJ/m2. Surface activated materials (contact angle < 90 degrees) exhibited free surface energies from 38.1 to 55.7 mJ/m2. Not all materials described as surface activated showed hydrophilic properties. Medians of impression quality ranking ranged from 1.75 (best) to 13.25 (worst), mean sulcus reproduction ranged from 30 to 52%. Significant differences (P < 0.05) in quality ranking and sulcus reproduction were found between certain materials but correlations were found neither between sulcus reproduction and free surface energy nor between quality ranking and free surface energy. CONCLUSIONS: For clinical impression recording, surface activation seems to be of minor relevance, at least in the two-stage putty and wash technique investigated and is superimposed by other material properties.  相似文献   

4.
STATEMENT OF PROBLEM: Improved dental stone has been widely used for producing dies for the fabrication of restorations with the lost-wax technique. Improved dental stone is used for several reasons, but it is selected most often because of its reasonable cost, ease of use, and ability to produce consistent results. PURPOSE: This study evaluated the ability of an epoxy resin die material and a type IV dental stone to dimensionally reproduce a custom-fabricated metal die. MATERIAL AND METHODS: Dies were fabricated and measurements were made from three reference lines. Measurements were repeated three times for the master die and for the specimen dies. A mean measurement and percent relative change for each dimension was calculated. RESULTS: A significant difference in the relative change for die height was found between the groups studied (p < 0.003). CONCLUSIONS: This epoxy die system will provide a degree of dimensional accuracy comparable to gypsum when used with addition silicone impression material.  相似文献   

5.
This study compared transverse strength and dimensional variations of die stone, epoxy resin, and polyurethane resin. The polyurethane resin was tested unfilled, then filled with 20%, 40%, and 60% silica, by weight. Transverse strength was evaluated for five test strips for each material, and an original calibration plate technique closely simulating intraoral conditions was introduced to evaluate dimensional accuracy. Two series of five measurements for dimensional variations were recorded on each test strip. The first series was 15 minutes after removal from mold and the second series of 5 minutes a week later. The results were computed with a parametric ANOVA and Scheffe's test at 95% confidence level (p < or = 0.05). These results confirmed that die stone recorded the least dimensional change but was rigid and brittle, whereas epoxy resin and polyurethane resin had suitable mechanical properties including greater dimensional variations. Incorporating silica filler in polyurethane resins also reduced their transverse strength and sponsored minimal dimensional variations.  相似文献   

6.
Effect of sodium hypochlorite disinfection of impressions on the size and quality of plaster models is studied. Twenty-minute submerging of silicone impressions in 0.5% sodium hypochlorite solution did not change their size and did not deteriorate the quality of surface and hardness of plaster models. Stomalgin impressions cannot be disinfected by sodium hypochlorite solution because of expressed destructive effect of this disinfectant on the impressions.  相似文献   

7.
The aim of this study was to determine whether the use of a topical surfactant (Hydrosystem), designed for clinical use, improved the quality of the impression surface of two poly(vinyl siloxane) materials used in vivo. Before impressions were taken, Hydrosystem was applied to the maxillary left or right premolar teeth, allocated at random, in 50 subjects. The untreated side acted as a control for each subject. The impressions were examined for quality of reproduction and number of surface defects. Hydrosystem was found to significantly improve the quality of reproduction.  相似文献   

8.
OBJECTIVE: To evaluate the accuracy of working casts for crown and bridge restorations made from twin mix putty/wash silicone elastomeric impression materials using different types of stock tray. DESIGN: A master cast was made from ivorine teeth in a mandibular model. Three teeth were prepared for full crown restorations to simulate a single unit and a three unit bridge. Impressions were taken using four different types of impression tray and two different viscosities of silicone putty, together with a wash. Full metal crowns were constructed and seated on duplicate master casts and measurements made of the marginal discrepancies. SETTING: The work was carried out in a dental technology laboratory in a university department of restorative dentistry in 1995/1996. RESULTS: Metal and rigid plastic impression trays showed the least discrepancy (about 50 microns), the latter slightly greater with the normal putty than the soft one. Impressions taken with flexible plastic trays produced considerable discrepancy with both putties, approximately 210 microns and 180 microns respectively. CONCLUSIONS: Metal and rigid plastic stock trays give greater accuracy in the putty/wash silicone twin mix impression technique compared with flexible plastic ones for crown and bridge work. Those using the latter should be aware of their shortcoming in this respect.  相似文献   

9.
It has been demonstrated that short-term disinfection can affect the surface properties of impression materials. This study evaluated advancing contact angle, receding contact angle, inhibition and mass loss of a polyether impression materials, and two different viscosities of an addition silicone impression material after long-term immersion disinfection (18 hours). The brand names of the impression materials tested were Impregum F, Extrude Extra, and Extrude Wash, and all were tested by use of the Wilhelmy technique; first, for the nondisinfected state, which served as controls, and then after 1 and 18 hours of disinfection in a full-strength solution of acid glutaraldehyde. Weight changes before and after the disinfection process were also measured to detect weight loss and mass change over time. All materials exhibited some degree of inhibition. Polyether lost 0.4% mass in air, which indicated loss of a volatile component. Polyether and addition silicone were both relatively hydrophobic and could be disinfected with acid glutaraldehyde for up to 18 hours without affecting wettability.  相似文献   

10.
While being shipped to a laboratory, impressions can be exposed to excessive temperatures. This study compared the effects of different time and temperature storage conditions, including temperature extremes of 66 C and -10 C, on the accuracy of addition silicone and polyether impressions. The greatest distortion generally occurred as a result of the 66 C temperature extreme. The authors recommend that impressions be poured in stone according to manufacturers' specifications before being shipped to a dental laboratory.  相似文献   

11.
A coordinate measurement machine with laser probe was used to measure the vertical distortion of the casts produced by use of three types of impression materials (irreversible hydrocolloid, condensation silicone, and addition silicone) and two types of trays (stock and custom trays). Results indicated that all impression groups showed positive vertical distortion (ranging from 0.00566 to 0.30299 mm) at the edentulous ridges and palatal area. The amount of the vertical distortion was greatest at the palatal area and was followed by the high edentulous ridge and the low edentulous ridge. Addition silicone, with either custom tray or stock tray, was the most accurate impression material. Condensation silicone was more accurate than irreversible hydrocolloid in custom tray impression. However, in stock tray impression the irreversible hydrocolloid was more accurate than the condensation silicone. The results suggest that, with careful manipulation, irreversible hydrocolloid with stock tray impression may provide a satisfactory cast for fabricating the framework of a distal extension removable partial denture.  相似文献   

12.
PURPOSE: Materials used to fabricate the most dimensionally accurate implant casts have not been identified experimentally. The purpose of this investigation was to examine the dimensional accuracy of implant casts fabricated with different materials. Measurements of linear horizontal dimensional change and strain produced on a master framework were evaluated and correlated. MATERIALS AND METHODS: A master framework was fabricated to fit an aluminum five-implant model. Forty polyether implant impressions of the aluminium model were randomly grouped and poured in either Vel-mix, Die Keen, Resin Rock, or Low Fusing Alloy. A digital veneer caliper was used to measure linear distance between the most distal abutments on each of the experimental implant casts and the master model. In addition, strain values were recorded from strain gauges bonded in the mesiodistal axis of the framework, which was secured by prosthetic retaining screws torqued to 10 Ncm. RESULTS: A one-way ANOVA showed a significant difference among the four die materials in dimensional change of the experimental casts (p = .0001). A post-hoc Duncan's multiple-range test (p < .05) showed that casts fabricated with Low Fusing Alloy had the least linear dimensional change from the master cast, but the material exhibited the greatest dimensional variability. A MANOVA (Wilks' Lambda) showed significant differences in strain on the framework based upon die material (p = .015). A post-hoc Duncan's multiple-range test (p < .05) showed that Resin Rock casts induced significantly less strain on the framework than the other materials. Negligible correlation was found between the linear horizontal dimensional change and the total absolute strain on the framework. CONCLUSION: Experimental implant casts made of Resin Rock minimized strain on the master framework and decreased the amount of framework distortion on casts of this material. Low Fusing Alloy yielded accurate casts, but highly variable linear dimensional changes in the horizontal dimension may preclude its clinical benefit.  相似文献   

13.
Indirect interim restorations have been traditionally fabricated on stone casts. Recently, flexible models fabricated from poly(vinyl siloxane) impression material have been suggested in place of stone casts. This study compared the marginal accuracy of indirect single-unit provisional restorations fabricated on stone casts with units made on poly(vinyl siloxane) impression material models. The mean marginal discrepancy of provisional restorations was compared for restorations fabricated from stone, low-viscosity poly(vinyl siloxane), and medium-viscosity poly(vinyl siloxane). Ten restorations were also fabricated directly on a master metal model (control). The mean marginal discrepancies were: control = 0.161 mm; stone model = 0.180 mm; low-viscosity poly(vinyl siloxane) = 0.245 mm; and medium-viscosity poly(vinyl siloxane) = 0.157 mm. The mean marginal discrepancy for the low-viscosity poly(vinyl siloxane) models was significantly higher than the other three groups. No significant difference was found between the control, stone cast, and medium-viscosity poly(vinyl siloxane) model groups.  相似文献   

14.
In this investigation it was planned to study the effect of disinfection time on the dimensional stability, compressive strength and hardness of gypsum die materials. Measurements of specimens treated with disinfectant were compared with the corresponding measurements of control specimens. The results of this study indicated that there was no difference in the dimensional stability, compressive strength and hardness. Therefore using the disinfectants will not affect gypsum die material.  相似文献   

15.
Trait referent terms (adjectives) were rated on the "bad-good" scale and the mean rating of each word computed. Based on these ratings, lists of 3 terms were constructed with varying distributions, and Ss formed impressions of a person therefrom. Results showed that (a) a positively skewed list produced a more positive (good) impression than one composed of terms having almost identical values, and (b) of 2 lists having identical means and midranges, the 1 including a more highly positive term produced the more positive impression. It was suggested that the connotation of an impression is influenced more by extreme terms than by relatively neutral ones. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

16.
JC Kois  PP Fan 《Canadian Metallurgical Quarterly》1997,18(7):699-704, 706-8; quiz 710
This article describes a technique that simplifies the making of an edentulous arch impression before the fabrication of a complete denture. Making an impression of an edentulous arch requires a unique combination of managing movable soft tissue commensurate with integrating different materials and a technique for accurate reproduction. The technique described requires a two-phase approach using a syringeable addition silicone during the border molding process and a condensation silicone wash material to capture the soft tissue while the functional border molding is repeated. These more recently developed products allow us to achieve similar results and are easier, faster, and more predictable than those products used previously.  相似文献   

17.
Investigated the relationship between level of cognitive development and the primacy effect in impression formation. 48 concrete operational and formal operational 8th graders were presented with blocks of information (photographs) about a target individual and were asked to write an impression. When the information was presented in 2 internally consistent but mutually contradictory blocks, impressions produced by concrete operational Ss contained a significantly greater proportion of evaluative statements in the same evaluative direction as the 1st block of information presented (the primacy effect) than did impressions produced by formal operational Ss. Results support the argument that the processing and organizing abilities measured in "objective" cognitive tasks are also used in social cognition. (10 ref) (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

18.
As a partial test of the view that schizophrenia is essentially a manipulatory phenomenon, the abilities of normal, neurotic, alcoholic-character disorder, and single and married schizophrenic groups (N = 180) to manage the impressions they make on others were compared. Ss were administered a semistructured interview twice-once each under instructions to make as bad and as good impressions as possible. All groups proved capable of managing the impressions they made to some degree. However, the single schizophrenics produced higher scores than any of the patient samples. Results argue against the hypothesis that schizophrenics are peculiarly capable impression managers. Moreover, the impression management scores of the groups did not change differentially in response to threat, casting some doubt on the view that schizophrenics are peculiarly inclined to produce spurious abnormal behavior to escape painful stress. Results contradict the view that the behaviors characterized as schizophrenic arise from special impression management tendencies rather than cognitive deficits. (15 ref) (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

19.
The purpose of this study was to test competing theories regarding the relationship between true halo (actual dimensional correlations) and halo rater error (effects of raters' general impressions on specific ratee qualities) at both the individual and group level of analysis. Consistent with the prevailing general impression model of halo rater error, results at both the individual and group level analyses indicated a null (vs. positive or negative) true halo-halo rater error relationship. Results support the ideas that (a) the influence of raters' general impressions is homogeneous across rating dimensions despite wide variability in levels of true halo; (b) in assigning ratings, raters rely both on recalled observations of actual ratee behaviors and on general impressions of ratees in assigning dimensional ratings; and (c) these 2 processes occur independently of one another. (PsycINFO Database Record (c) 2010 APA, all rights reserved)  相似文献   

20.
This study compared the effects of repeated microwave oven and double-boiler liquefactions and prolonged autoduplicator storage on four physical properties of one reversible hydrocolloid duplicating material. No significant differences were observed between the linear dimensional change and detail reproduction of the three liquefaction techniques. Tear strength differences most clearly distinguished the techniques and effects of aging. Fifteen double-boiler remeltings produced tear strength values lower than those recorded for material stored in an autoduplicator for 2 weeks. Thirty microwave melting cycles still produced tear strength values equivalent to that of the autoduplicator material. After 30 melting cycles the compressive strengths of the microwave and double-boiler materials were inferior to that of the stored autoduplicator material.  相似文献   