1.
A simulation and design tool to improve effectiveness and efficiency in design, and analysis of air to refrigerant heat exchangers, CoilDesigner, is introduced. A network viewpoint was adopted to establish the general-purpose solver and allow for analysis of arbitrary tube circuitry and mal-distribution of fluid flow inside the tube circuits. A segment-by-segment approach within each tube was implemented, to account for two-dimensional non-uniformity of air distribution across the heat exchanger, and heterogeneous refrigerant flow patterns through a tube. Coupled heat exchangers with multiple fluids inside different subsets of tubes can be modeled and analyzed simultaneously. A further sub-dividing-segment model was developed in order to address the significant change of properties and heat transfer coefficients in the single-phase and two-phase regime when a segment experiences flow regime change. Object-oriented programming techniques were applied in developing the program to facilitate a modular, highly flexible and customizable design platform and in building a graphic user-friendly interface. A wide variety of working fluids and correlations of heat transfer and pressure drop are available at the user's choice. The model prediction with CoilDesigner was verified against experimentally determined data collected from a number of sources.  相似文献   

2.
The objective of this study is to provide experimental data that can be used in the optimal design of flat plate finned-tube heat exchangers with large fin pitch. In this study, 22 heat exchangers were tested with a variation of fin pitch, number of tube row, and tube alignment. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row. The reduction in the heat transfer coefficient of the four-row heat exchanger coil was approximately 10% as the fin pitch decreased from 15.0 to 7.5 mm over the Reynolds number range of 500–900 that was calculated based on the tube diameter. For all fin pitches, the heat transfer coefficient decreased as the number of tube row increased from 1 to 4. The staggered tube alignment improved heat transfer performance more than 10% compared to the inline tube alignment. A heat transfer correlation was developed from the measured data for flat plate finned-tubes with large fin pitch. The correlation yielded good predictions of the measured data with mean deviations of 3.8 and 6.2% for the inline and staggered tube alignment, respectively.  相似文献   

3.
Hydrocarbons are considered as alternative fluids for refrigeration, air-conditioning and heat pump applications. Pure butane, propane or their mixtures can be adopted, but due to their flammable properties, the systems have to be designed in such a way that the refrigerant charge is minimized. Therefore, compact heat exchangers and enhanced geometries are adopted in such systems. In this paper, the current state of the art for two-phase heat transfer calculations for pure hydrocarbons and their mixtures is reviewed and analysed. Recommendations are proposed for estimating evaporation and condensation heat transfer in various geometries including enhanced tubes as well as compact heat exchangers.  相似文献   

4.
One of the main components of an ice slurry system is the melting heat exchanger, in which ice slurry absorbs heat resulting in the melting of ice crystals. Design calculations of melting heat exchangers are mainly based on heat transfer and pressure drop data, but recent experimental studies have shown that superheating of ice slurry should also be considered. This paper presents ice slurry melting experiments with a tube-in-tube heat transfer coil. The experimental results indicate that operating conditions such as ice slurry velocity, heat flux, solute concentration, ice fraction, and ice crystal size determine the degree of superheating. The various influences are explained by considering the melting process as a two-stage process consisting of the heat transfer between wall and liquid and the combined heat and mass transfer between liquid and crystals. Bigger ice crystals and higher solute concentrations decrease the rate of the second stage and therefore increase the degree of superheating.  相似文献   

5.
Independently of the choice of refrigerant, environmental and or safety issues can be minimised by reducing the amount of refrigerant charge per heat pump or refrigeration system. In the investigation reported here, a laboratory test rig was built, simulating a water-to-water heat pump with a heating capacity of 5 kW. The system was designed to minimize the charge of refrigerant mainly by use of mini-channel aluminium heat exchangers. It was shown that the system could be run with 200 g of propane at typical Swedish operating conditions without reduction of the COP compared to a traditional design. Additional charge reduction is possible by selecting proper compressor lubrication oils or by using a compressor with less lubrication oil.  相似文献   

6.
In order to establish a reliable procedure for estimation of air pressure drop, experiments on plate finned tube heat exchangers have been conducted, as well as the research on the open literature. The procedure of Kays and London was tested against the experimental data and significant level of uncertainty was found. Using own experimental data, as well as previously published data of Kays and London, new correlation for estimation of air pressure drop has been established. Statistical parameters of new correlation enable the conclusion that it can be used for wide range of Reynolds numbers.  相似文献   

7.
The thermal-hydraulic performance under conditions of an initial frost growth on the air-side surface, and for subsequent ‘refrosting’ after a defrost period is experimentally studied for folded-louvered-fin, microchannel heat exchangers. In total, five heat exchangers are considered; the thermal performances during one frost-growth cycle for four different fin geometries are compared in terms of overall heat transfer coefficient, pressure drop, and j and f factors; the defrost and refrost characteristics of two heat exchangers are compared to explore geometry effects. Typically, the performance under refrosting conditions becomes periodic and repeatable after the third or fourth refrosting cycle. The allowable frost growth period (before a defrost is required), the defrost requirement, and the thermal-hydraulic performance depend on heat exchanger geometry for the specimens used in this study.  相似文献   

8.
Current and future prospects of enhanced heat transfer in ammonia systems   总被引:2,自引:0,他引:2  
In the last decade a moderate headway has been made in the application of enhanced surface heat exchangers in ammonia refrigeration systems. This has been a result of the persistent issue of ozone and global warming which has resulted in keen interest in natural refrigerants such as ammonia that has played a prominent role in the refrigeration industry for years, particularly in the field of food, beverage and marine. The only drawback with ammonia is the toxicity; hence, if smaller heat exchangers could be introduced in order to reduce ammonia charge, this negative aspect about ammonia can be addressed to a great extent. In order to achieve this goal, novel and compact heat exchangers with enhanced surfaces have to be introduced. This paper presents an over view of the status of ammonia as a refrigerant and discusses the present and the future trends in the development of compact heat exchangers for use in ammonia refrigeration.  相似文献   

9.
This paper presents heat transfer data for a multiport minichannel heat exchanger vertically mounted as an evaporator in a test-rig simulating a small water-to-water heat pump. The multiport minichannel heat exchanger was designed similar to a shell-and-tube type heat exchanger, with a six-channel tube of 1.42 mm hydraulic diameter, a tube-side heat transfer area of 0.777 m2 and a shell-side heat transfer area of 0.815 m2. Refrigerant propane with a desired vapour quality flowed upward through the tubes and exited with a desired superheat of 1–4 K. A temperature-controlled glycol solution that flowed downward on the shell-side supplied the heat for the evaporation of the propane. The heat transfer rate between the glycol solution and propane was controlled by varying the evaporation temperature and propane mass flow rate while the glycol flow rate was fixed (18.50 l min−1). Tests were conducted for a range of evaporation temperatures from −15 to +10 °C, heat flux from 2000 to 9000 W m−2 and mass flux from 13 to 66 kg m−2 s−1. The heat transfer coefficients were compared with 14 correlations found in the literature. The experimental heat transfer coefficients were higher than those predicted by many of the correlations. A correlation which was previously developed for a very large and long tube (21 mm diameter and 10 m long) was in good agreement with the experimental data (97% of the data within ±30%). Several other correlations were able to predict the data within a reasonable deviation (within ±30%) after some adjustments to the correlations.  相似文献   

10.
This paper presents the experimental heat transfer coefficients and pressure drop measured during refrigerant R134a vaporisation inside a small brazed plate heat exchanger (BPHE): the effects of heat flux, refrigerant mass flux, saturation temperature and outlet conditions are investigated. The BPHE tested consists of 10 plates, 72 mm in width and 310 mm in length, which present a macro-scale herringbone corrugation with an inclination angle of 65° and corrugation amplitude of 2 mm.The experimental results are reported in terms of refrigerant side heat transfer coefficients and frictional pressure drop. The heat transfer coefficients show great sensitivity both to heat flux and outlet conditions and weak sensitivity to saturation temperature. The frictional pressure drop shows a linear dependence on the kinetic energy per unit volume of the refrigerant flow.The experimental heat transfer coefficients are also compared with two well-known correlations for nucleate pool boiling and a correlation for frictional pressure drop is proposed.  相似文献   

11.
General models for the design of the heat exchangers (absorber, generator, condenser and evaporator) of a prototype of an air-cooled absorption chiller of 2 kW for air-conditioning using the pair H2O–LiBr have been developed. An absorption machine of such characteristics has been constructed to be used as a test facility for validating the results obtained from the mathematical models developed. The discrepancies considering the heat exchanged between numerical results and experimental data are under 15% in most cases for all these components except the condenser, where the discrepancies are higher. The conclusions reported will lead to: (i) future improvements of the mathematical simulation models and (ii) improvements in the experimental infrastructure.  相似文献   

12.
A new way to assess the performance of refrigeration system models is presented in this paper, based on the estimation of cycle parameters, such as the evaporation temperature which will determine the validity of the method. This paper is the first of a series which will also study the influence of the heat transfer coefficient models on the estimation of the refrigeration cycle parameters. It focuses on fin and tube evaporators and includes the dehumidification process of humid air. The flow through the heat exchanger is considered to be steady and the refrigerant flow inside the tubes is considered one-dimensional. The evaporator model is discretised in cells where 1D mass, momentum and energy conservation equations are solved by using an iterative procedure called SEWTLE. This procedure is based on decoupling the calculation of the fluid flows from each other assuming that the tube temperature field is known at each fluid iteration. Special attention is paid to the correlations utilised for the evaluation of heat transfer coefficients as well as the friction factor on the air and on the refrigerant side. A comparison between calculated values and measured results is made on the basis of the evaporation temperature. The experimental results used in this work correspond to an air-to-water heat pump and have been obtained by using R-22 and R-290 as refrigerants.  相似文献   

13.
This paper reports heat transfer results obtained during condensation of refrigerant propane inside a minichannel aluminium heat exchanger vertically mounted in an experimental setup simulating a water-to-water heat pump. The condenser was constructed of multiport minichannel aluminium tubes assembled as a shell-and-tube heat exchanger. Propane vapour entered the condenser tubes via the top end and exited sub-cooled from the bottom. Coolant water flowed upward on the shell-side. The heat transfer areas of the tube-side and the shell-side of the condenser were 0.941 m2 and 0.985 m2, respectively. The heat transfer rate between the two fluids was controlled by varying the evaporation temperature while the condensation temperature was fixed. The applied heat transfer rate was within 3900–9500 W for all tests. Experiments were performed at constant condensing temperatures of 30 °C, 40 °C and 50 °C, respectively. The cooling water flow rate was maintained at 11.90 l min−1 for all tests. De-superheating length, two-phase length, sub-cooling length, local heat transfer coefficients and average heat transfer coefficients of the condenser were calculated. The experimental heat transfer coefficients were compared with predictions from correlations found in the literature. The experimental heat transfer coefficients in the different regions were higher than those predicted by the available correlations.  相似文献   

14.
This paper studies refrigeration cycles in which plate heat exchangers are used as either evaporators or condensers. The performance of the cycle is studied by means of a method introduced in previous papers which consists of assessing the goodness of a calculation method by looking at representative variables such as the evaporation or the condensation temperature depending on the case evaluated. This procedure is also used to compare several heat transfer coefficients in the refrigerant side. As in previous works the models of all the cycle components are considered together with the heat exchanger models in such a way that the system of equations they provide is solved by means of a Newton–Raphson algorithm. Calculated and measured values of the evaporation and the condensation temperatures are also compared. The experimental results correspond to the same air-to-water heat pump studied in other papers and they have been obtained by using refrigerants R-22 and R-290.  相似文献   

15.
In order to achieve widespread use of heat pumps across the full spectrum of potential applications, it is critical that the first cost of the units is acceptable. There are many factors influencing this cost, including the number of units manufactured, the ease of installation, the complexity of the control requirements, and the cost of the working fluid(s). A common feature of all heat pump cycles is the presence of at least one heat exchanger, indeed some heat-driven cycles are composed almost entirely of heat exchangers, each having a different but critical role to play. There are several important aspects of heat exchangers that can help to reduce first cost of these components and the system, (in addition to the possible positive impact on coefficient of performance). Two of these are discussed here — compact heat exchangers (CHEs) and heat transfer enhancement. The latter may be directly associated with CHEs but can be equally beneficial in reducing approach temperature differences in 'conventional' shell and tube heat exchangers. Both are essential features of many intensified processes, which the author argues need compatible heat pumps if the market for the latter is to flourish. In this paper, the most recent types of CHE are described, with emphasis on the benefits they can bring to heat pump first cost and performance. Heat transfer enhancement in heat pumps is also reviewed.  相似文献   

16.
Single-phase heat transfer and pressure drop characteristics of a commercially available internally micro-finned tube with a nominal outside diameter of 7.94 mm were studied. Experiments were conducted in a double pipe heat exchanger with water as the cooling as well as the heating fluid for six sets of runs. The pressure drop data were collected under isothermal conditions. Data were taken for turbulent flow with 3300 ≤ Re ≤ 22,500 and 2.9 ≤ Pr ≤ 4.7. The heat transfer data were correlated by a Dittus–Boelter type correlation, while the pressure drop data were correlated by a Blasius type correlation. The correlation predicted values for both the Nusselt number and the friction factors were compared with other studies. It was found that the Nusselt numbers obtained from the present correlation fall in the middle region between the Copetti et al. and the Gnielinski smooth tube correlation predicted Nusselt number values. For pressure drop results, the present correlation predicted friction factors values were nearly double that of the Blasius smooth tube correlation predicted friction factors. It was also found that the rough tube Gnielinski and Haaland correlations can be used as a good approximation to predict the finned tube Nusselt number and ffriction factor, respectively, in the tested Reynolds number range.  相似文献   

17.
Ice slurry performance in a concentric corrugated tube heat exchanger is experimentally studied in this work in order to compare experimental results to theoretical prediction obtained using the correlations proposed in previous papers. Once the validity of those correlations is verified, the behaviour of the studied heat exchanger is analyzed for different ice slurry flow conditions and compared to the results obtained when a heterogeneous storage is used and only carrier fluid flows through the heat exchanger. According to the performance evaluation criterion used – variation in heat transfer rate for equal pressure drop and surface area – the most remarkable conclusion obtained is that slurry improves the behaviour of the heat exchanger studied for all the cases analyzed, although the increase in heat transfer rate is always lower than 15%, being in most cases lower than 5%.  相似文献   

18.
This paper presents the experimental tests on HFC-134a condensation inside a small brazed plate heat exchanger: the effects of refrigerant mass flux, saturation temperature and vapour super-heating are investigated.A transition point between gravity controlled and forced convection condensation has been found for a refrigerant mass flux around 20 kg/m2 s. For refrigerant mass flux lower than 20 kg/m2 s, the saturated vapour heat transfer coefficients are not dependent on mass flux and are well predicted by the Nusselt [Nusselt, W., 1916. Die oberflachenkondensation des wasserdampfes. Z. Ver. Dt. Ing. 60, 541–546, 569–575] analysis for vertical surface. For refrigerant mass flux higher than 20 kg/m2 s, the saturated vapour heat transfer coefficients depend on mass flux and are well predicted by the Akers et al. [Akers, W.W., Deans, H.A., Crosser, O.K., 1959. Condensing heat transfer within horizontal tubes. Chem. Eng. Prog. Symp. Ser. 55, 171–176] equation. In the forced convection condensation region, the heat transfer coefficients show a 30% increase for a doubling of the refrigerant mass flux. The condensation heat transfer coefficients of super-heated vapour are 8–10% higher than those of saturated vapour and are well predicted by the Webb [Webb, R.L., 1998. Convective condensation of superheated vapour. ASME J. Heat Transfer 120, 418–421] model. The heat transfer coefficients show weak sensitivity to saturation temperature. The frictional pressure drop shows a linear dependence on the kinetic energy per unit volume of the refrigerant flow and therefore a quadratic dependence on the refrigerant mass flux.  相似文献   

19.
A prototype liquid-to-refrigerant heat exchanger was developed with the aim of minimizing the refrigerant charge in small systems. To allow correct calculation of the refrigerant side heat transfer, the heat exchanger was first tested for liquid-to-liquid (water-to-water) operation in order to determine the single-phase heat transfer performance. These single-phase tests are reported in this paper. The heat exchanger was made from extruded multiport aluminium tubes and was designed similar to a shell-and-tube heat exchanger. The heat transfer areas of the shell-side and tube-side were approximately 0.82 m2 and 0.78 m2, respectively. There were six rectangular-shaped parallel channels in a tube. The hydraulic diameter of the tube-side was 1.42 mm and of the shell-side 3.62 mm. Tests were conducted with varying water flow rates, temperature levels and heat fluxes on both the tube and shell sides at Reynolds numbers of approximately 170–6000 on the tube-side and 1000–5000 on the shell-side, respectively. The Wilson plot method was employed to investigate the heat transfer on both the shell and tube sides. In the Reynolds number range of 2300–6000, it was found that the Nusselt numbers agreed with those predicted by the Gnielinski correlation within ±5% accuracy. In the Reynolds number range of 170–1200 the Nusselt numbers gradually increased from 2.1 to 3.7. None of the previously reported correlations for laminar flow predicted the Nusselt numbers well in this range. The shell-side Nusselt numbers were found to be considerably higher than those predicted by correlations from the literature.  相似文献   

20.
The aim of this paper is to present a developed semi-analytical model for the simulation of dehumidifying air–liquid fin-and-tube heat exchangers. The simulation strategy and the mathematical methodology are described in detail. The model is based on -NTU method, and formulated in a compact way for dry and wet surface situations (temperature or enthalpy driven, respectively). Both rating and design procedures have been developed for fully dry, partially wet, or fully wet surface conditions. The model predictions are compared with experimental data obtained on a wavy and a plain finned heat exchanger, giving reasonably accurate results. The limitations of the empirical information used are clearly identified in the work. The aim of this model is to provide a fast but reliable rating and design numerical tool for air–liquid heat exchanger applications.  相似文献   