首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A heat pipe thermosyphon radiator for use in domestic and industrial heating applications is presented. A test cell for the radiator is described and various experimental tests have been performed to determine the feasibility and performance of a heat pipe thermosyphon radiator. The thermosyphon radiator has been tested with freon 11, acetone, methanol and water as working fluids, and was compared with a conventional radiator. Best performance was obtained using methanol and acetone, and compares well with the conventional radiator. In addition, with these working fluids the thermosyphon radiator, by design, has desirable isothermal surfaces. The worst performance was with water, where local hot and cold spots formed on the radiator surface and the performance was poor. A natural convection/radiation model is presented for the thermosyphon radiator, and good agreement between measured and calculated heat transfer is obtained. The model reveals that typically 60% of the heat is transferred by natural convection and the remaining 40% by radiation. Advantages and further development of the thermosyphon radiator are discussed. © 1997 by John Wiley & Sons, Ltd.  相似文献   

2.
An especial open thermosyphon device used in high-temperature evacuated tubular solar collectors was designed. The indoor experimental research was carried out to investigate the thermal performance of the open thermosyphon using respectively the deionized water and water-based CuO nanofluids as the working liquid. Effects of filling rate, kind of the base fluid, nanoparticle mass concentration and the operating temperature on the evaporating heat transfer characteristics in the open thermosyphon were investigated and discussed. Experiment results show the optimal filling ratio to the evaporator is 60% and the thermal performance of the open thermosyphon increase generally with the increase of the operating temperature. Substituting water-based CuO nanofluids for water as the working fluid can significantly enhance the thermal performance of the evaporator and evaporating heat transfer coefficients may increase by about 30% compared with those of deionized water. The CuO nanoparticles mass concentration has remarkable influence on the heat transfer coefficient in the evaporation section and the mass concentration of 1.2% corresponds to the optimal heat transfer enhancement.  相似文献   

3.
Nano-fluid is employed as the working medium for a conventional 211 μm wide × 217 μm deep grooved circular heat pipe. The nano-fluid used in this study is an aqueous solution of 35 nm diameter silver nano-particles. The experiment was performed to measure the temperature distribution and to compare the heat pipe thermal resistance using nano-fluid and DI-water. The tested nano-particle concentrations ranged from 1 mg/l to 100 mg/l. The condenser section of the heat pipe was attached to a heat sink that was cooled by water supplied from a constant-temperature bath maintained at 40 °C.At a same charge volume, the measured nano-fluid filled heat pipe temperature distribution demonstrated that the thermal resistance decreased 10–80% compared to DI-water at an input power of 30–60 W. The measured results also show that the thermal resistances of the heat pipe decrease as the silver nano-particle size and concentration increase.  相似文献   

4.
The paper is concerned with the study of two-phase solar thermosyphon for domestic hot water (SDHW). Due to a combination of ideas of the heat pipe and classical thermosyphon, the heat transfer in the proposed installation is to be realised by the liquid - gas phase change, what should increase significantly both the heat efficiency of the system and the system applicability.  相似文献   

5.
In this research, the critical heat flux (CHF) due to flooding limit of thermosyphon heat pipe using triethylene glycol (TEG)–water mixture has been investigated. From the experiment it is found that, use of TEG–water mixture can extend the heat transport limitation compared with pure water and higher heat transfer is obtained compared with pure TEG at high temperature applications. Moreover it is found that ESDU equation is appropriate to predict the CHF of the thermosyphon in case of TEG–water mixture.For thermosyphon air preheater at high temperature applications, it is found that with selected mixture content of TEG–water in each row of the thermosyphon the performance of the system could be increased approximately 30–80% compared with pure TEG for parallel flow and 60–115% for counter flow configurations. The performances also increase approximately 80–160% for parallel flow and 140–220% for counter flow compared with those of pure dowtherm A which is the common working fluid at high temperature applications.  相似文献   

6.
Dilute dispersion of silver nano-particles in pure water was employed as the working fluid for conventional 1 mm wick-thickness sintered circular heat pipe. The nanofluid used in present study is an aqueous solution of 10 and 35 nm diameter silver nano-particles.The experiment was performed to measure the temperature distribution and compare the heat pipe temperature difference using nanofluid and DI-water. The tested nano-particle concentrations ranged from 1, 10 and 100 mg/l. The condenser section of the heat pipe was attached to a heat sink that was cooled by water supplied from a constant temperature bath maintained at 40 °C.At a same charge volume, the measured nanofluids filled heat pipe temperature distribution demonstrated that the temperature difference decreased 0.56–0.65 °C compared to DI-water at an input power of 30–50 W. In addition, the nanofluid as working medium in heat pipe can up to 70 W and is higher than pure water about 20 W.  相似文献   

7.
The thermal performance of thermosyphon flat-plate solar water heater with a mantle heat exchanger was investigated to show its applicability in China. The effect on the performance of the collector of using a heat exchanger between the collector and the tank was analyzed. A “heat exchanger penalty factor” for the system was determined and energy balance equation in the system was presented. Outdoor tests of thermal performance of the thermosyphon flat-plate solar water heater with a mantle heat exchanger were taken in Kunming, China. Experimental results show that mean daily efficiency of the thermosyphon flat plate solar water heater with a mantle heat exchanger with 10 mm gap can reach up to 50%, which is lower than that of a thermosyphon flat-plate solar water heater without heat exchanger, but higher than that of a all-glass evacuated tubular solar water heater.  相似文献   

8.
An experimental study was carried out to understand the flow boiling heat transfer of water based CuO nanofluids in the evaporator of a thermosyphon loop under steady sub-atmospheric pressures. Experimental results show that both the heat transfer coefficient (HTC) and the critical heat flux (CHF) of flow boiling in the evaporator of the thermosyphon loop could be enhanced by substituting nanofluids for water. The operating pressure has apparent impact on the HTC enhancement of nanofluids. However, the operating pressure has negligible effect on the CHF enhancement. There exists an optimal mass concentration of nanoparticles corresponding to the best enhancement effect. Experimental results show that the CHF enhancement results mainly from the existing of the coating layer on the heated surface formed by the sediment of nanoparticles. However, the HTC enhancement results from the effects of both the existing of the coating layer and the change of thermophysical properties of the working fluid.  相似文献   

9.
实验选用外径为4mm、内径为2mm的铜质脉动热管研究了氧化石墨烯对以去离子水和体积分数为50%的乙醇溶液为工质的脉动热管传热性能的影响。实验分别采用加有少量氧化石墨烯的去离子水溶液(简称氧化石墨烯水溶液)和体积分数为50%的乙醇溶液(简称氧化石墨烯乙醇溶液),氧化石墨烯质量分数均为0.03%。实验发现:氧化石墨烯对以去离子水为工质的脉动热管传热性能具有强化作用,对以体积分数为50%的乙醇溶液为工质的脉动热管传热性能的影响较差,但都和脉动热管的加热功率密切相关。对于以去离子水为工质的脉动热管,在加热功率低于20W时,氧化石墨烯对脉动热管的强化作用较弱;当加热功率在30~60W之间时,氧化石墨烯对脉动热管的强化作用较强,在3.71~11.33%之间,且强化作用随加热功率的增大呈逐渐增强趋势;但随着功率继续增大,氧化石墨烯的强化作用逐渐减弱,当加热功率达到80W后,热管传热性能减弱,原因可能是氧化石墨烯颗粒出现了沉降现象。  相似文献   

10.
结合西安市某个埋深为2505 m的U型深埋管换热系统,在原位实验验证的基础上建立三维全尺寸数值计算模型,进而模拟分析埋管内热流载体种类对强化埋管换热的效果。埋管内热流载体除常规使用的水外,还选用Al2O3/水、CuO/水和SiO2/水3种纳米流体。通过改变这3种纳米流体的纳米颗粒体积浓度分别为0.1%、0.3%、0.5%及1.0%,分析纳米流体种类及纳米颗粒体积浓度对埋管换热的影响。研究结果表明,就整个埋管的换热而言,纳米流体的强化换热效果较小。因此,通过改变埋管热流载体来达到埋管强化换热的方法并不高效合理。  相似文献   

11.
在微层蒸发模型的理论基础上,对热虹吸管内部设置分流管结构强化沸腾传热者机理分析。建立分流管强化热哐吸管内部沸腾传热模型,同时选择七种不同的分流管开孔结构,与光滑管进行了对比实验研究,寻得最佳分流管结构,并综合大量实验数据建立强化沸腾传热准数方程式。  相似文献   

12.
By establishing a mathematical model in the thermosyphon system, the numerical simulation method is used for the temperature field, flow field distribution in heat pipe simulated calculation in recent years. In this article, we combine the thermosyphon engineering actuality, build up the Nusselt model, write the visual program with the VB code, and make use of the computer to carry on imitating the calculation. Meanwhile, the calculation predicted temperature profile in the thermosyphon was compared with experimental measurements and a good agreement was observed. Through the research, it can provide theoretical basis for the optimization of heat pipe model in the future.  相似文献   

13.
The effect of the axial conduction through the pipe wall on the performance of a thermosyphon was experimentally investigated in this study. Two 2-phase closed thermosyphons were tested; each had the same dimensions, materials and partially filled with R134a. The only difference between them was that one had a thermal break within the adiabatic section that resisted axial conduction between the evaporator and the condenser sections. The thermosyphons were heated by a constant-temperature hot bath and cooled by water via a concentric heat exchanger. The experiments were performed for different bath temperatures and different fill ratios. It was found that the axial conduction through the pipe wall caused an increase in the overall heat transfer coefficient, evaporation heat transfer coefficient and condensation heat transfer coefficient of the thermosyphon. However, the fraction of heat transfer associated with axial conduction decreased as the heat flux increased. For small heat flux (Tb = 30 °C), the increment of the evaporation and condensation heat transfer coefficient contributed by axial conduction reached 100% and 25%, respectively. For high heat flux (Tb = 60 °C), the increment was negligible (less than 1%).  相似文献   

14.
The waste heat recovery by heat pipes is accepted as an excellent way of saving energy and preventing global warming. This paper is a literature review of the application of heat pipes heat exchangers for the heat recovery that is focused on the energy saving and the enhanced effectiveness of the conventional heat pipe (CHP), two-phase closed thermosyphon (TPCT) and oscillating heat pipe (OHP) heat exchangers. The relevant papers were allocated into three main categories, and the experimental studies were summarized. These research papers were analyzed to support future works. Finally, the parameters of effectiveness of the CHP, TPCT and OHP heat exchangers were described. This review article provides additional information for the design of heat pipe heat exchangers with optimum conditions in the heat recovery system.  相似文献   

15.
This article investigates experimentally the long-term thermal performance of a two-phase thermosyphon solar water heater and compares the results with the conventional systems. Experimental investigations are conducted to obtain the system thermal efficiencies from the hourly, daily and long-term performance tests. Different heat transfer mechanisms, including natural convection, geyser boiling, nucleate boiling and film-wise condensation, are observed in the two-phase thermosyphon solar water heater while solar radiation varies. The thermal performance of the proposed system is compared with that of four conventional solar water heaters. Results show that the proposed system achieves system characteristic efficiency 18% higher than that of the conventional systems by reducing heat loss for the two-phase thermosyphon solar water heater.  相似文献   

16.
The enhancement heat transfer of the heat transfer devices can be done by changing the fluid transport properties and flow features of working fluids. In the present study, therefore, the enhancement of heat pipe thermal efficiency with nanofluids is presented. The heat pipe is fabricated from the straight copper tube with the outer diameter and length of 15, 600 mm, respectively. The heat pipe with the de-ionic water, alcohol, and nanofluids (alcohol and nanoparticles) are tested. The titanium nanoparticles with diameter of 21 nm are used in the present study which the mixtures of alcohol and nanoparticles are prepared using an ultrasonic homogenizer. Effects of %charge amount of working fluid, heat pipe tilt angle and %nanoparticles volume concentrations on the thermal efficiency of heat pipe are considered. The nanoparticles have a significant effect on the enhancement of thermal efficiency of heat pipe. The thermal efficiency of heat pipe with the nanofluids is compared with that the based fluid.  相似文献   

17.
This paper reports an experimental investigation of a closed-loop thermosyphon system charged with water and other low saturation fluids, such as ethanol, acetone, and methanol, for different adiabatic lengths, filling ratios, and heat loads. The closed-loop thermosyphon with two inline vertical heaters in the evaporator section and forced air-cooled plate-type heat exchanger in the condenser section, connected by a changeable adiabatic length, is investigated at different working conditions. Out of five filling ratios used in the analysis, at 0.6 filling ratio, the loop thermosyphon is seen to be operated at its best. The acetone-charged loop thermosyphon shows the lowest values (up to 72% reduction) of overall thermal resistance than that of other fluids and significantly higher effectiveness, due to the plate-type forced air-cooled condenser. For the acetone-filled thermosyphon, an almost 15% increase in the effectiveness is observed by changing the adiabatic length from 800 to 200 mm. This study suggests that the limitation of the loop thermosyphon with a water-cooled condenser to cool electronic components, computational clusters, and data centers is well fulfilled by the loop thermosyphon with plate-type forced air-cooled condenser. The nucleate pool boiling correlation is developed and validated for the loop thermosyphon system to determine the evaporator heat transfer coefficient.  相似文献   

18.
Thermal performance of a two-phase thermosyphon energy storage system   总被引:1,自引:0,他引:1  
This article presents an energy storage system, which can be readily integrated with the building structure. It stores heat supplied by solar energy via the two-phase closed loop thermosyphon to storage tank and releases stored heat in energy storage material via two-phase closed thermosyphon to the heat exchanger through the flow of transport fluid. The functions of such energy storage system have three operating modes, i.e., heat charge, heat discharge, and simultaneous charge and discharge. The thermal performance of the system with alcohol and water as working fluid is experimentally investigated. The results show that the storage system employing alcohol as working fluid in the loop thermosyphon provides better performance; the system gives optimum heat charge and discharge performance under 35–40% fill ratio, regardless whether the working fluid is water or alcohol. The system displays optimum charge efficiency of 73% and optimum discharge efficiency of 85% with alcohol as working fluid.  相似文献   

19.
《Applied Thermal Engineering》2007,27(14-15):2426-2434
This paper presents measurements and predictions of a heat pipe-equipped heat exchanger with two filling ratios of R134a, 19% and 59%. The length of the heat pipe, or rather thermosyphon, is long (1.5 m) as compared to its diameter (16 mm). The airflow rate varied from 0.4 to 2.0 kg/s. The temperatures at the evaporator side of the heat pipe varied from 40 to 70 °C and at the condenser part from 20 to 50 °C. The measured performance of the heat pipe has been compared with predictions of two pool boiling models and two filmwise condensation models. A good agreement is found. This study demonstrates that a heat pipe equipped heat exchanger is a good alternative for air–air exchangers in process conditions when air–water cooling is impossible, typically in warmer countries.  相似文献   

20.
Improving the working fluid transport properties is a way to enhance the thermal performance of heat transfer equipment. In this research work, a two-dimensional numerical simulation is used to investigate the thermal performance of a nanofluid-filled cylindrical heat pipe. The considered nanofluid is pure water as the base fluid with dispersed Al2O3 nanoparticles. Effects of particle volume fractions, particle diameters, various heat inputs, and wick structures on thermal performance of the heat pipe are investigated and the results are compared with that of the pure water. A comparison is made for the first time between the results of a simulation by considering fluid flow in the liquid-wick region and treating this region as pure conduction. The results show the heat pipe thermal performance enhancement and a decrease in thermal resistance for about 31% when 5% particle volume fraction with a particle diameter of 10 nm is used. Also, an insignificant effect of heat input on thermal resistance and variation of pressure distribution in the presence of nanoparticles are observed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号