首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND AND PURPOSE: Weak or absent CT enhancement in pleomorphic adenomas of the parotid gland has been observed immediately after i.v. contrast administration. This feature can result in poor lesion conspicuity relative to both normal parotid tissue and other parotid abnormalities. The purpose of this study was to document the delayed CT enhancement characteristics of parotid pleomorphic adenomas and to preliminarily compare these results with the enhancement characteristics of other parotid gland tumors. METHODS: Preoperative CT scans from 18 pathologically proved parotid gland neoplasms were reviewed retrospectively. Lesions included eight pleomorphic adenomas, four Warthin's tumors, two squamous cell carcinomas, two mucoepidermoid cancers, one acinic cell carcinoma, and one melanoma metastasis. In all cases, axial CT was performed after the administration of 100 to 150 mL of i.v. contrast material, followed by delayed (average, 24 minutes; range, 13 to 34 minutes) coronal CT scanning. The mean normalized Hounsfield unit (HU) attenuation of each lesion was computed by drawing a region of interest around the entire mass and dividing the resulting HU value by that of the contralateral uninvolved parotid gland. RESULTS: For all eight pleomorphic adenomas, the degree of contrast enhancement increased and became progressively more uniform with time. Mean normalized axial lesion enhancement averaged 1.20 +/- 0.35 at 8 minutes, compared with 2.30 +/- 0.66 on the coronal scans at 24 minutes. For the 10 nonpleomorphic adenomas, no significant change was found in either the degree or pattern of contrast enhancement between the immediate and delayed CT scans. In these tumors, peak enhancement was reached early, during axial scanning. CONCLUSION: Delayed CT contrast enhancement is observed in parotid pleomorphic adenomas, increasing in both degree and homogeneity with time. This feature may be useful in selecting an appropriate contrast delay when scanning possible pleomorphic adenomas to improve lesion conspicuity and, potentially, to better distinguish these tumors from other parotid abnormalities.  相似文献   

2.
PURPOSE: To assess the attenuation of the adrenal gland with computed tomography (CT) before and after multiple phases of contrast enhancement in both control subjects and patients with adenomas and nonadenomas. MATERIALS AND METHODS: Seventy-two patients with 78 adrenal masses (41 adenomas, 37 nonadenomas) underwent helical CT. Forty subjects served as controls. Unenhanced CT was performed followed by enhanced CT at 30, 60, 90, and 180 seconds and 30 minutes. RESULTS: At unenhanced CT, mean attenuation was 4 HU +/- 16 for adenomas compared with 37 HU +/- 12 for the nonadenomas (P < .001) and 24 HU +/- 3 for normal glands. Although the mean attenuation of nonademonas was significantly greater than that of adenomas on 60- and 90-second scans (P < .001), there was greater overlap in attenuation of the adenomas and nonadenomas than on unenhanced images. At 180 seconds, nonadenomas had higher attenuation than adenomas (73 HU +/- 17 vs 41 HU +/- 18; P < .001). At 30 minutes, all adenomas had attenuation less than 37 HU, whereas all nonadenomas had attenuation greater than 41 HU. CONCLUSION: Delayed-enhanced CT scans obtained 30 minutes after administration of contrast material can enable differentiation of adenomas and nonadenomas.  相似文献   

3.
PURPOSE: To assess the effect of the injection rate of contrast medium on pancreatic and hepatic enhancement at abdominal helical computed tomography (CT). MATERIALS AND METHODS: Sixty-four contrast medium-enhanced abdominal helical CT scans (64 adult patients) were obtained with 150 mL of contrast medium. The injection rate was 2.5 mL/sec for the first 32 scans and 5.0 mL/sec for the remaining 32. Scans were obtained at 5-sec intervals, with an intermediate 8-sec breathing interval. Hepatic and pancreatic enhancement levels were measured and averaged, and time-attenuation curves were plotted for both groups. Differences in weight, age, time to peak pancreatic and hepatic enhancement, and peak enhancement were assessed with the Student t test. RESULTS: Both peak enhancement and time to peak enhancement were significantly different between the two injection rates (P < or = .002), with faster, more intense hepatic and pancreatic enhancement at the higher rate. At 2.5 mL/sec, the pancreas reached a peak attenuation level of 65 HU at 69 sec, and the liver reached a peak of 58 HU at 87 sec. At 5.0 mL/sec, the pancreas reached a peak attenuation of 84 HU at 43 sec, and the liver reached a peak of 75 HU at 63 sec.  相似文献   

4.
OBJECTIVE: The purpose of this study was to evaluate a recently developed hardware and software system for CT scanning that generates images in real time and switches to helical CT scanning by either a visual cue or a region of interest (ROI) amplitude threshold. SUBJECTS AND METHODS: We randomly and prospectively divided 120 abdominal CT examinations into three groups. Two groups received 75 ml of contrast agent at 1.5 ml/sec. Helical CT scanning began after visualization of the contrast bolus arrival in the hepatic veins (visual cue triggering) (39 patients) or after reaching an ROI threshold (automated ROI threshold triggering) (39 patients). A third group served as a control group (42 patients) and received 150 ml of contrast agent at 1 ml/sec. Quality of hepatic enhancement was assessed objectively and subjectively. Comparisons were made after stratifying each group into three weight classes. RESULTS: Errors occurred in 12 (31%) of 39 examinations in the group with automated ROI threshold triggering. In that group, we found a significantly (p < .04) lower mean hepatic enhancement in two of three weight categories, and a significantly (p < .04) lower mean subjective scan quality in one of three weight categories, than we found in the group with visual cue triggering. CONCLUSION: Optimizing portal venous phase helical CT of the liver after a low-volume bolus of contrast agent and an injection rate of 1.5 ml/sec is best achieved by initiating helical CT scanning after visualizing the contrast bolus arrival within the liver rather than after reaching a preset attenuation threshold.  相似文献   

5.
We report a case of pseudosarcomatous fibromyxoid tumor of the bladder in a 23-year-old man with a 2 month history of painless gross hematuria, which was studied by biphasic contrast-enhanced helical CT. CT demonstrated a 2 cm diameter polypoid enhancing mass in the anterior bladder wall. The lesion measured 103 and 91 HU on early and delayed images, respectively. Increased contrast enhancement was attributed to a histologically highly vascular myxoid stroma.  相似文献   

6.
The aim of this study was to establish a practical, simple protocol that reliably produces high quality dynamic incremental computed tomography (CT) of the liver. We reviewed 90 patients randomly allocated into six different protocols. All had preliminary unenhanced scans followed by a dynamic incremental CT of the liver. An initial delay of 30 seconds was used from the commencement of the injection of Iopamiro 370. The groups were: 1. Pump infusion (a) 100 mls at 2 mls/sec scanning inferosuperiorly. (b) 100 mls at 2 mls/sec scanning superoinferiorly. (c) 100 mls at 1 ml/sec scanning inferosuperiorly. (d) 50 mls at 1 ml/sec scanning inferosuperiorly. 2. 40 mls hand injected bolus followed immediately by 60 ml pump infusion at 1.3 mls/sec scanning inferosuperiorly. 3. 50 mls hand injected bolus scanning inferosuperiorly. The parameters recorded were the degree of hepatic parenchymal and hepatic venous enhancement and the aortic--IVC difference at the last slice through the liver, all measured in Hounsfield units. The protocols using 100 mls of contrast produced approximately twice the parenchymal and hepatic venous enhancement compared with those using 50 mls. Approximately 60-90% of examinations using 100 mls produced scans through the entire liver during the bolus or nonequilibrium phase, deemed the most sensitive for the detection of focal lesions, compared with 13-33% of those using 50 mls. Equally satisfactory results were obtained using the relatively inexpensive Biotel power injector preceded by a 40 ml hand injected bolus, compared with using an Angiomat angiography infusion pump.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
OBJECTIVE: To validate the safety of gadolinium-diethylenetriamine pentaacetic acid (GD-DTPA) by measuring its effect on pancreatic capillary perfusion and acinar injury in acute pancreatitis. BACKGROUND: Contrast-enhanced computed tomography (CECT) is proposed as a gold standard for early evaluation of acute necrotizing pancreatitis. However, iodinated contrast media used for CECT have been shown in these circumstances to reduce pancreatic capillary flow and increase necrosis and mortality. Recent reports suggest that post-GD MRI provides images comparable to CECT in the assessment of severe acute pancreatitis. METHODS: Necrotizing pancreatitis was induced in 14 Wistar rats by intraductal glycodeoxycholic acid (10 mM/L) and intravenous caerulein (5 microg/kg/h) over 6 hours. Intravital microscopic quantitation of pancreatic capillary blood flow was performed using fluorescein isothiocyanate-labeled erythrocytes after induction of pancreatitis and 30 and 60 minutes after an intravenous bolus of either Ringer's solution or GD-DTPA (0.2 mL/kg). RESULTS: The two study groups were comparable with regard to mean arterial pressure, heart rate, arterial blood gases, hematocrit, amylase, lipase, and trypsinogen activation peptide production throughout the experiment. GD-DTPA did not reduce capillary flow (1.93 +/- 0.05 nL/capillary/min) compared to animals infused with Ringer's solution (1.90 +/- 0.06 nL/capillary/min). CONCLUSIONS: Intravenous injection of GD-DTPA does not further impair pancreatic microcirculation or increase acinar injury in acute necrotizing pancreatitis. Because of this advantage over CT contrast medium, further development of MRI as a staging tool in acute pancreatitis seems desirable.  相似文献   

8.
OBJECTIVE: The goal of our study was to determine the effect of contrast material injection rate and patient demographic variables on vascular enhancement for abdominal CT angiography and compare test injection results with actual patterns of vascular enhancement. SUBJECTS AND METHODS: One hundred twenty-five patients underwent abdominal CT angiography. For each patient, CT attenuation values (Hounsfield units) of the aorta were determined before and after IV contrast administration, every 3 sec between 21 and 60 sec. A peak aortic enhancement value and the time needed to reach peak and aortic enhancement thresholds of 150 and 200 H were determined. All patients received 150 ml of nonionic contrast material at 3 ml/sec in 25 patients and 4 ml/sec in 100 patients. A test injection of 15 ml was used to compute a scan delay in 46 patients. Patient age, sex, weight, injection rate, and test injection results were compared with vascular enhancement patterns. RESULTS: For the 125 patients, the mean aortic enhancement at each time point was greater than 150 H. Patient weight was inversely correlated (r2 = -.62) with aortic enhancement. The test injection did not accurately predict actual aortic enhancement peak value or time. Test injection delay time was significantly correlated with time to reach aortic enhancement thresholds of 150 and 200 H. The 4 ml/sec rate resulted in a higher peak aortic enhancement (320+/-58 H versus 281+/-49 H) (mean +/- SD, p < .01) that was reached quicker than with the 3 ml/sec injection rate (45+/-5 sec versus 52+/-5 sec) (p < .01). Injecting at 4 ml/sec resulted in greater aortic enhancement values at 24-45 sec, whereas 3 ml/sec produced significantly better aortic enhancement at 54-60 sec. CONCLUSION: The test injection correlated better with time to reach specific aortic enhancement thresholds than with time to peak aortic enhancement. For a given amount of contrast material, faster injection rates resulted in greater vascular enhancement that occurred earlier.  相似文献   

9.
OBJECTIVE: We evaluated the accuracy of unenhanced helical CT with enteric contrast material in the diagnosis of appendicitis in children and adults treated at a community hospital. SUBJECTS AND METHODS: Over an 8-month period, 100 consecutive patients with right lower quadrant pain and suspected appendicitis were prospectively evaluated. Thin-collimation helical CT scanning was performed after administration of enteric contrast material. CT interpretations were correlated with surgical pathology (45 patients) and clinical follow-up (55 patients). RESULTS: The findings of 33 CT scans were interpreted as positive for appendicitis (29 true-positives and four false-positives), and the findings of 67 were interpreted as negative for appendicitis (66 true-negatives and one false-negative). Sensitivity was 97%, specificity was 94%, accuracy was 95%, positive predictive value was 88%, and negative predictive value was 99%. In the 67 CT scans with negative findings for appendicitis, an alternative diagnosis was made for 36 patients (54%). CONCLUSION: Unenhanced helical CT with enteric contrast material for the evaluation of appendicitis can be implemented in a community hospital. In our study, such imaging achieved excellent accuracy.  相似文献   

10.
PURPOSE: To evaluate objectively the effects of a microbubble contrast agent on the color Doppler ultrasound (US) examination of breast lesions. MATERIALS AND METHODS: Forty-seven patients aged 23-71 years underwent color Doppler US before and after intravenous injection of a microbubble contrast agent. A 3-minute computer-assisted assessment of the color pixel density (CPD) was used to evaluate objectively the increase in the number of color Doppler US signals, the transit time of the microbubble bolus, and the potential additional differential diagnostic information. RESULTS: Peak CPD at contrast agent-enhanced color Doppler US was 14.3% +/- 8.1 (mean +/- 1 standard deviation) for carcinomas and 9.3% +/- 4.9 for benign lesions (P = .04). The time to peak enhancement was shorter in carcinomas (38 seconds +/- 20) than in benign tumors (71 seconds +/- 48, P = .02). Final CPD was close or equal to baseline values. With the median of 13% for peak CPD as a threshold, the sensitivity for this parameter was 55%, the specificity was 79%, and the accuracy was 62% (P = .04). For a median time to peak of 50 seconds, the sensitivity was 84%, the specificity was 57%, and the accuracy was 76%. CONCLUSION: After microbubble contrast agent injection, carcinomas and benign lesions behave differently in degree, onset, and duration of Doppler US enhancement. High interindividual variability and temporal variations in the Doppler US signal still limit the value of these criteria for prospective diagnosis.  相似文献   

11.
OBJECTIVE: This study aimed to compare the effectiveness of helical computed tomography (CT) versus conventional CT in the preoperative assessment of metallic intraocular foreign bodies on axial, coronal, and multiplanar reconstruction images in clinical routine. DESIGN: Prospective comparative trial, alternate assignment of consecutive patients. PARTICIPANTS: Eighteen patients with penetrating eye injuries and suspected metallic intraocular foreign bodies were studied. INTERVENTION: Alternate patients were assigned to undergo either helical CT or conventional CT in the axial plane. Both the helical and the conventional data were transferred to a workstation, and reconstructions in the coronal and sagittal planes were performed. Additional direct coronal scanning was performed only when necessary for preoperative assessment. MAIN OUTCOME MEASURES: The quality of the directly obtained axial and coronal, as well as the reconstructed coronal and sagittal images, was assessed for each, imaging method based on the ability to detect and accurately localize foreign bodies. The size of the foreign bodies was measured and compared to the actual diameter. Total examination time and radiation dose delivered to the lens were measured for each imaging method. RESULTS: All foreign bodies were detected by each scanning method on the axial, the coronal, and on the reconstructed planes. The quality of the axial images was similar for helical and conventional CT. The helical technique provided high-quality reconstructed images comparable in quality to the directly obtained coronal planes in conventional CT. Reconstructions by conventional technique were not useful for preoperative assessment. The examination time for the total orbital volume was 18 seconds for helical CT examinations and 52 seconds for conventional CT examinations. Radiation dose delivered to the lens for the complete examination was 35 mGy for helical CT axial scanning, 56 mGy for conventional CT axial scanning, and 63 mGy for conventional CT coronal scanning. CONCLUSIONS: Helical CT multiplanar imaging offers several significant advantages for the preoperative assessment of metallic intraocular foreign bodies compared to the conventional CT technique in clinical practice, including short examination time, reduced motion artifacts, reduced radiation exposure, and the ability to obtain diagnostically useful coronal and sagittal reconstruction images without the need for additional scanning.  相似文献   

12.
PURPOSE: To study the dose-response relationship in FP 736-03 (48 mg I/ml), hepatocyte-specific contrast medium for CT of the liver. MATERIAL AND METHODS: A nude-rat model of experimental hepatic metastases was used. CT of the liver was performed before and after i.v. injection of FP 736-03 at 4 different doses: 0.25, 0.5, 1.0 and 2.0 ml/kg b.w. Attenuation in the normal liver parenchyma and in the metastases was measured and plotted as a function of time. RESULTS: The enhancement of the normal liver parenchyma increased in the dose range studied. No increase was found in the metastases: the attenuation here remained constant during the observation period. The maximum enhancement values at doses of 0.25, 0.5, 1.0 and 2.0 ml/kg b.w. were (mean +/- SD) 13.5 +/- 2.7, 30.1 +/- 4.2, 33.2 +/- 4.5 and 59.7 +/- 13.1 HU respectively.  相似文献   

13.
OBJECTIVE: The purpose of this study was to compare dual-phase helical CT and endosonography for the diagnosis and staging of pancreatic tumors. SUBJECTS AND METHODS: Thirty patients with suspected pancreatic tumors underwent endosonography and dual-phase helical CT. A pathologic diagnosis was obtained in all cases with surgery (n = 23) or biopsy (n = 7), resulting in 27 neoplasms. Dual-phase helical CT and endosonographic findings were correlated with surgical and pathologic findings to determine diagnosis and resectability of pancreatic tumors. RESULTS: Overall diagnostic sensitivity was 92% for dual-phase helical CT and 100% for endosonography (p = .45). Overall accuracy for staging of pancreatic tumors was 93% for both dual-phase helical CT and endosonography. Overall accuracy for predicting resectability was 90% for both dual-phase helical CT and endosonography. Accuracy of predicting unresectability was 100% for dual-phase helical CT and 86% for endosonography (p > .80). Differences were not considered statistically significant. CONCLUSION: Dual-phase helical CT and endoscopic sonography do not differ significantly for diagnosis and assessment of resectability of pancreatic tumors.  相似文献   

14.
INTRODUCTION: High-resolution computed tomography (HRCT) with iodinated contrast material has been used by many authors to study solitary pulmonary nodules (SPNs). The degree of enhancement was correlated with the nodule malignancy. MATERIAL AND METHODS: Forty adult patients were examined, before and after contrast agent administration, with incremental dynamic CT. We selected 22 patients with SPNs (3-30 mm phi, except one with 40 mm phi). The CT numbers of the inner nodule were calculated before and 1, 2 and 3 minutes after the i.v. administration of a weight-related dose (1.5 mL/kg/min) of nonionic iodinated contrast agent. A dose of 100 mL contrast agent was used in the first 6 patients. The difference in CT numbers between unenhanced images and the images with maximum enhancement (max. attenuation) was also calculated. RESULTS: Histologic diagnoses included 4 tuberculomas, 3 hamartomas and 15 malignant tumors (9 adenocarcinomas, 5 squamous cell carcinomas and 1 non-Hodgkin lymphoma). The CT numbers (in Hounsfield units, HU) of malignant nodules ranged 12-31 HU (mean: 21.5 HU) before contrast agent administration; the "long-standing" tuberculomas ranged 11-22 HU (mean: 16.5 HU) and the hamartomas had a mean density of 10.5 HU. We excluded for the study two "fresh" tuberculomas, one of which was surrounded by a low-attenuation infiltrate (the halo sign). We selected a threshold value of 20 HU on enhanced CT images to distinguish malignant (> or = 20 HU) from benign (< or = 20 HU) nodules. All lung cancers had complete enhancement (mean density: 35.5 HU). With 20 HU as the threshold value for a positive test, sensitivity was 100%, specificity 85.7%, positive predictive value 93.8% and negative predictive value 100%; test bias was 1.067. CONCLUSION: Positron emission tomography (PET) with 2-[fluorine-18] fluoro-2-deoxy-D glucose is reported to be as accurate as enhanced HRCT, but it does not provide accurate morphological information, is not widely available and it is quite expensive: therefore, in our opinion, CT should be preferred. After examining over 100 patients, we may use our results in the decision analysis comparing surgical risk with cancer risk.  相似文献   

15.
Enhancement of normal functioning myocardium was quantitated in 15 dogs by serial computed transmission tomographic (CT) images during the bolus (10 ml/sec.) or slow (1 ml/sec.) intravenous injection of diatrizoate contrast media (1 ml/kg body weight) in concentrations of 37, 18.5, or 9.25 g iodine (I)/dl. Homogenous images of myocardial enhancement were obtained. However, major streak artifacts were observed frequently when contrast material was injected as a bolus, and myocardial edges were not defined clearly when contrast material with a concentration of 9.25 g I/dl was injected slowly. Time-attenuation curves of normal myocardial enhancement constructed from serial CT images demonstrated a peak in contrast enhancement (delta Hounsfield units, 22-45) followed by a period of deterioration that lasted two to three minutes. These results can be applied to make optimal use of both single (static) and serial (dynamic) myocardial CT images.  相似文献   

16.
PURPOSE: To assess the value of the peripheral washout sign on delayed contrast material-enhanced magnetic resonance (MR) images in differentiation of benign from malignant breast masses. MATERIALS AND METHODS: In 49 women with 79 breast lesions (55 malignant and 24 benign), dynamic contrast-enhanced MR imaging was performed every 90 seconds during the first 7 minutes and repeated at 10, 20, 30, 40, 50, and 60 minutes after injection of contrast material. Qualitative analysis of the images was performed to evaluate the presence of the peripheral washout sign (a hypointense zone in the periphery of the lesion relative to the center). Quantitative analysis of the images was performed by measuring the signal intensity of the periphery and center of the lesions. RESULTS: The peripheral washout sign was seen in 28 (51%) of the 55 carcinomas on delayed contrast-enhanced MR images (> 10 minutes). Quantitative analysis demonstrated different enhancement profiles of the periphery and center of these lesions. The periphery showed early increase and decrease of enhancement, while the center showed gradual increase and persistent enhancement. The peripheral washout sign was not seen in any of the benign lesions. Specificity was 100% and sensitivity was 51% for diagnosis of breast carcinoma. CONCLUSION: Peripheral washout may be a reliable sign of malignancy on delayed contrast-enhanced MR images of the breast.  相似文献   

17.
PURPOSE: To evaluate routine non-contrast material-enhanced helical computed tomography (CT) of the adrenal glands in patients with non-small cell lung carcinoma to facilitate characterization of adrenal masses detected in an unmonitored environment (i.e., the radiologist on duty did not look at the acquired images before the patient left the scanner). MATERIALS AND METHODS: One hundred consecutive patients with non-small cell lung carcinoma were referred for CT evaluation of the chest; chest and abdomen; or chest, abdomen, and brain. All underwent unenhanced CT of the adrenal glands before the requested CT examination. The morphologic features, size, and attenuation values of the adrenal masses were calculated. Attenuation values of adrenal masses from prior imaging, if available, were compared with those at follow-up imaging to classify these masses. Variable unit cost increase in obtaining these additional images was estimated. RESULTS: Fifteen adrenal masses were identified in 13 patients. In one patient, bilateral ill-defined adrenal masses were present. In 12 patients, 13 masses were sharply circumscribed: Seven were less than 10 HU and six were 20 HU or greater at unenhanced CT. Nine of these 12 patients received iodinated contrast material. Without the unenhanced CT, 10 adrenal masses in these nine patients would have been indeterminate for malignancy. In six of these nine patients, the adrenal mass was the only potential site of metastatic disease. The unenhanced CT data helped classify three of these masses as benign-10 HU or less- and three as indeterminate-greater than 10 HU. CONCLUSION: Unenhanced CT of the adrenal glands can prospectively characterize adrenal masses and obviate further examination in patients with lung carcinoma.  相似文献   

18.
INTRODUCTION: Since many benign and malignant pathologic conditions can appear as solitary pulmonary nodules, to establish nodule nature is always necessary for correct patient management. Recently, some authors have demonstrated the effectiveness of incremental dynamic CT in distinguishing cancerous from noncancerous lesions. The purpose of this work is to report our personal experience in this field. MATERIAL AND METHODS: We reviewed the incremental dynamic CT scans of 21 patients with a solitary pulmonary nodule < 3.5 cm phi without any calcifications, cavities and fat--namely, 15 carcinomas, 3 granulomas, 2 hamartomas, 1 abscess. Lesion density was evaluated before and 30 s, 1, 2, 3 and 5 min after contrast agent administration; we used a circular region of interest consisting of the central portion of the nodule in all cases and of 60-70% of its area in most cases. We subdivided the nodules into two groups, according to their enhancement: the nodules with > 20 HU and those with < 20 HU. All the lesions were submitted to surgery and histologic studies. RESULTS: Fourteen of 15 carcinomas and one hamartoma had contrast enhancement > 20 HU; an abscess exhibited marked ring-shaped contrast enhancement (positive predictive value: 87%). One carcinoma, three granulomas and one hamartoma had no contrast enhancement, or else it was < 20 HU (negative predictive value: 80%). DISCUSSION: Recently, some authors have demonstrated that malignant nodules, studied with incremental dynamic CT, have higher contrast enhancement than benign nodules. A value > 20 HU is a good predictor of malignancy (positive predictive value: 90%) and, conversely, a value < 20 HU is an unquestionable sign of benignity (negative predictive value: 100%). Our findings confirm the positive predictive value of enhancement > 20 HU, but not its negative predictive value because we found a malignant nodule without contrast enhancement. CONCLUSIONS: Incremental dynamic CT is an effective indicator of solitary pulmonary nodule nature, but its predictive value is not absolute and therefore this technique should be integrated with biopsy in the cases which are clinically or radiologically suspicious.  相似文献   

19.
PURPOSE: The aim of this study was to investigate the efficacy of helical CT for lumbosacral pathology. MATERIALS AND METHODS: We performed helical CT with multiplanar reconstruction, including the formation of oblique transaxial and coronal images, in 62 patients with various lumboscral disorders, including 32 non-enhanced CT and 36 CT after myelography. We correlated the appearance of the stenotic spinal canal and neoplastic disease with the findings on MRI obtained at nearly the same time. RESULTS: We obtained helical CT images in all cases in about 30 seconds. The diagnostic ability of helical CT was roughly equal to that of MRI in patients with spondylosis deformans, spondylolisthesis and herniated nucleus pulposus. There was no significant difference in diagnostic value for degenerative lumbosacral disease with canal and foramnial stenosis between non-enhanced and post-myelography helical CT. However, non-enhanced helical CT could not clearly demonstrate neoplastic disease because of the poor contrast resolution. CONCLUSION: Helical CT was useful in evaluating degenerative disorder and its diagnostic value was nearly equal to that of MRI. We considered that helical CT may be suitable for the assessment of patients with severe lumbago owing to the markedly shortened examination time. However, if helical CT is used as a screening method for lumbosacral disease, one must be careful of its limitations, for example, poor detectability of neoplastic disease, vascular anomalies and so on.  相似文献   

20.
This study was aimed at assessing the clinical usefulness of measuring the contrast enhancement (CE) of solitary pulmonary nodules (SPN) in distinguishing benign from malignant lesions. We used spiral CT to study prospectively 35 pulmonary lesions presenting as SPNs < 30 mm phi; we evaluated the CE of the nodules 120 minutes after the administration of 100 mL of nonionic contrast material (= 30 grams of iodine), at 2 mL/s. The final diagnosis of the 35 SPNs was made at surgery (27 cases); positive sputum cytology (2 cases), 12 months' follow-up (5 cases) or fine-needle aspiration biopsy and 6 months' follow-up (1 case). Thus, 25 of 35 SPNs proved malignant (11 adenocarcinomas, 5 squamous cell carcinoma, 2 large cell carcinomas, 2 carcinoids, 1 small cell carcinoma, 2 cases with positive sputum cytology, 2 metastases) and the extant 10 of 35 proved benign. Malignant nodules enhanced markedly more (mean value: 36.8 HU) more than benign lesions (mean value: 18.6 HU). CE exceeded 20 HU in 23/25 malignant nodules and did not in 2/25; it did not exceed 20 HU in 6/10 benign nodules and did in 4/10. With 20 HU as the threshold value for a positive test (malignancy), sensitivity was 92%, specificity 60% and accuracy 83%; positive and negative predictive values were 85% and 75%, respectively. In conclusion, CE evaluation is a sensitive, although not very specific, indicator of malignancy in SPNs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号