首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
理论推导出钴 60集装箱检测中辐射测量系统的冲激响应函数。在此基础上 ,提出了一种处理图像模糊的时域反卷积算法 ,使图像细节突出 ,图像质量得到明显改善。  相似文献   

2.
放射源存在一定的操作风险和辐射安全风险,关系到环境、公众和工作人员的健康和安全。本文介绍新疆伊犁哈萨克自治州友谊医院一例Ⅰ类医用60Co放射源退役的前期准备工作和实施过程。  相似文献   

3.
给出了加固和非加固 5 4HC0 4电路在不同辐射偏置下的低剂量率辐射实验结果 ,探讨了电流转移曲线、辐射感生漏电流、阈值电压、转换电压随辐射剂量的变化关系。  相似文献   

4.
在闪烁体耐辐照特性研究中,通过比较闪烁体受辐照前后闪烁探测器系统灵敏度的变化,说明在大辐照剂量后闪烁探测器是否处于正常工作状态.利用三通道脉冲X射线源(平均能量800keV)、DPF脉冲中子源(D-T中子能量14.4MeV),通过实验标定几种常用闪烁探测器对脉冲中子、脉冲X射线的相对灵敏度值.所用闪烁体包括φ40mm,不同厚度的CeF3,NaI(T1)和BaF2等无机晶体及ST-401,ST-1422,NE111等塑料闪烁体.  相似文献   

5.
Rapid annealing test results show that the hardened RCA/Sandia 1802 Bulk CMOS Microprocessor will function immediately after application of intense ionizing radiation pulses. This result was established in LINAC tests using a comprehensive test procedure which exercised the ?P in logarithmic time intervals from 10 ?s to 1000 s. It was found that no loss of functionality occurs for doses up to about 280 KRads. At 790 KRads, the device initially loses functionality but anneals in 600 ms. At 1.6 MRads, the device loses functionality for 4 s, and at 2.4 MRads, the device loses functionality for at least 1000 s. A sample size of five devices was used. The 1802 ?P was tested using hardware and software especially designed for this purpose. The microprocessor was exercised using software routines of exponentially increasing length starting at 10 ?s after the pulse. A measure of ?P functionality was therefore provided at logarithmically increasing sample times, After 2 seconds was reached, the routines repeated every two seconds up to 1000 seconds when the test ended. The hardware and software are described in detail.  相似文献   

6.
^60Co集装箱检测系统的研制   总被引:13,自引:15,他引:13  
本文阐述了一种使用3.7~11.1TBq^60Co工业探伤源的特殊集装箱检测系统,借助于采用高灵敏度阵列探测器以及其他技术措施,此种^60Co集装箱检测系统具有良好的检测性能,它对100mm铁屏的“反差灵敏度(CI)”及“像质值(IQI)”分别等于0.7%和2.5%,而其“铁穿透本领(SP)”则达到约240mm^60Co集装箱检测系统比加速器型检测系统便宜,可靠,占地少,而其“穿透本领”则显著高于  相似文献   

7.
研究了辐照电子直线加速器辐射剂量测定的技术方法,在测量方法上采取实测与蒙特卡洛模拟计算相结合的方法提高辐射剂量测定的准确度和可操作性;用化学剂量计建立电子束吸收能量测量的方法;用平板电离室建立电子束表面剂量、电子束吸收剂量率测量的方法;用半导体探测器阵列建立电子束辐照均匀性测量的方法。  相似文献   

8.
9.
10.
介绍了^60Co铁路货车检测系统中查验站软件的设计思路与实现方法。查验站软件具有处理火车车厢和图像和访问检查信息两大功能,分别用两个独立的进程实现,进程通讯采用内存映射文件。  相似文献   

11.
介绍了60Co 工业DR无损检测系统的构成与性能,该系统的扫描环节使用60Co工业探伤源,阵列电离室并采用电流积分型前置放大器阵列,该系统综合性能优良,运行与维护费用低,占地面积小,而且操作方便,安全可靠。  相似文献   

12.
介绍了围绕放射性同位素^192Ir、^60Co源的应用开展的防护管理工作。首先是加强放射工作人员的培训,对源的使用执行严格的管理程序和规定;重点说明了在不同应用现场采取的具体防护及管理措施;最后,介绍了射线源的采购、废源处理和运输等相应的管理程序及辐射事故应急计划等。上述一系列的管理体系和规章制度,保证了源的安全使用,并创造了良好的经济效益。  相似文献   

13.
Transient tests on rad-hard microprocessor and memory devices of CMOS/SOS design were carried out with the Boeing Linac as the electron pulse source of 40 ns duration. Mean temporary and permanent upset levels were determined to be 1.1×1010 and 1.3×1010 rads (Si)/s for the microprocessor, and 1.3×1010 and 5.1×1010 rads (Si)/s for the memory, respectively. All of these values correspond to the worst case exposure conditions which were found to be static rather than dynamic (i.e., a transition state). Storage pattern sensitivity for both device types during exposure was also determined to be a dominant-zero pattern, that is, a few ones in a field of zeroes in the case of the microprocessor, and a single one in a field of zeroes for the memory. Transient annealing measurements on the microprocessor indicated a recovery time of 20 ?s to 87% of VOH following a 27 kilorad dose/pulse for a 1.8 ?s electron pulse.  相似文献   

14.
作为辐射成像系统,^60Co铁路货物检测系统的安全连锁单元是其中重要组成部分。介绍了安全连锁单元的设计要求,详细说明了安全连锁单元的实现方法,介绍了系统实际运行中安全连锁单元的工作情况,并提出了进一步提高系统安全性的方法。  相似文献   

15.
^60Co铁路货物检测系统具有极高的自动化程度,监控单元是其自动控制系统中的重要组成部分,详细介绍了监控单元的设计思想,实现了区别于传统实现方法的新型监控单元。  相似文献   

16.
60Co源照射装置是产生参考辐射场的重要设备,根据国家标准的要求,参考辐射场中散射剂量率不应大于总剂量率的5%.参考辐射场中的散射辐射贡献和均匀性是描述60Co源照射装置辐射性能的重要参数,利用蒙特卡罗方法对60Co源照射装置产生辐射场的散射辐射和均匀性进行研究,为60Co源照射装置的设计提供了理论依据.待照射装置加工完成后,利用PTW电离室对辐射场进行测量.结果表明,辐射场中散射辐射和均匀性与模拟结果符合较好,辐射特性满足设计要求.  相似文献   

17.
急性毒性试验小鼠经口给~(60)Co辐照花粉,雌雄两性小鼠的LD_(50)均>21500mg/kg,表明辐照花粉属实际无毒级。用三种短期试验进行诱变性检测,Ames试验对TA_(97)、TA_(98)、TA_(100)及TA_(102)四种菌株皆不能引起诱变。骨髓细胞微核试验阴性。精原细胞染色体畸变分析未见畸变率增加。上述结果表明辐照花粉对人体服用是安全的。  相似文献   

18.
The intensity ratio of the 2,158 and 2,505keV γ-rays in the decay of 60Co was measured by applying the photonuclear reactions 9Be(γ, n) and 2D(γ, n). The result obtained was an intensity ratio of {I (2,158)I(2,505)}–237, which exceeded all the values reported in available literature on previous measurements.  相似文献   

19.
20.
建立了小体积海水中134Cs、137Cs和60Co的联合分析方法,确定了最佳实验条件。采用磷钼酸铵富集法对海水中放射性铯进行浓集后,其上清液利用氢氧化钴沉淀载带海水中的60Co,用γ能谱仪进行测量。结果表明:该法对海水中放射性134Cs、137Cs和60Co的回收率分别为87%~95%、87%~95%和89%~93%,检测限分别为0.048、0.051、0.046 Bq/L。另外,对2017年IAEA国际比对(IAEA-RML-2017-01)海水样品中的134Cs、137Cs和60Co进行分析测量,核素分析结果的最终评价均为“通过”,验证了本实验室采用的134Cs、137Cs和60Co联合分析方法的可行性和可靠性,为今后该方法在常规海洋环境放射性监测中的应用推广奠定了基础。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号