首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
为强化城市污水脱氮除磷,研发了厌氧/缺氧/好氧/缺氧-膜生物反应器(A2/O/A-MBR)新工艺,并建设了设计处理规模为2万m3/d实际工程.对该工程的长期监测表明,出水C()D、TN、NH4+-N和TP的平均浓度分别为20.6、6.67、1.05、0.19 mg/L,优于《城镇污水处理厂污染物排放标准》中的一级A标准...  相似文献   

2.
The effectiveness of the Fenton's reagent (H(2)O(2)/Fe(2+)) in the treatment of carpet dyeing wastewater was investigated under different operational conditions, namely, H(2)O(2) and FeSO(4) concentrations, initial pH and temperature. Up to 95% COD removal efficiency was attained using 5.5 g/l FeSO(4) and 385 g/l H(2)O(2) at a pH of 3, temperature of 50 degrees C. The H(2)O(2)/Fe(2+) ratio (g/g) was found to be between 95 and 290 for maximum COD removal. It was noteworthy that, keeping H(2)O(2)/Fe(2+) ratio constant within the range of 95-290, it became possible to decrease FeSO(4) concentration to 1.1 g/l and H(2)O(2) concentration to 96.3 g/l, still achieving nearly the same COD removal efficiency. The relative efficiencies of Fenton's oxidation and coagulation stages revealed that Fenton's coagulation removed organic compounds which were not removed by Fenton's oxidation, indicating that the Fenton's coagulation acted as a polishing step.  相似文献   

3.
Fluidized zero valent iron (ZVI) process was conducted to reduce hexavalent chromium (chromate, CrO(4)(2-)) to trivalent chromium (Cr(3+)) from electroplating wastewater due to the following reasons: (1) Extremely low pH (1-2) for the electroplating wastewater favoring the ZVI reaction. (2) The ferric ion, produced from the reaction of Cr(VI) and ZVI, can act as a coagulant to assist the precipitation of Cr(OH)(3(s)) to save the coagulant cost. (3) Higher ZVI utilization for fluidized process due to abrasive motion of the ZVI. For influent chromate concentration of 418 mg/L as Cr(6+), pH 2 and ZVI dosage of 3g (41 g/L), chromate removal was only 29% with hydraulic detention time (HRT) of 1.2 min, but was increased to 99.9% by either increasing HRT to 5.6 min or adjusting pH to 1.5. For iron species at pH 2 and HRT of 1.2 min, Fe(3+) was more thermodynamically stable since oxidizing agent chromate was present. However, if pH was adjusted to 1.5 or 1, where chromate was completely removed, high Fe(2+) but very low Fe(3+) was present. It can be explained that ZVI reacted with chromate to produce Fe(2+) first and the presence of chromate would keep converting Fe(2+) to Fe(3+). Therefore, Fe(2+) is an indicator for complete reduction from Cr(VI) to Cr(III). X-ray diffraction (XRD) was conducted to exam the remained species at pH 2. ZVI, iron oxide and iron sulfide were observed, indicating the formation of iron oxide or iron sulfide could stop the chromate reduction reaction.  相似文献   

4.
The influence of Fe(0)/Fe(2+)/Fe(3+) on the nitrobenzene (NB) degradation in the anaerobic granular sludge was studied and the results demonstrated that: adding iron powder into the anaerobic sludge could exert an accelerative effect on the NB degradation and the degradation rate was faster than that by using iron or the anaerobic sludge alone. The external addition of Fe(2+)/Fe(3+) exhibited different influences on the NB degradation depending on the concentrations of Fe(2+)/Fe(3+) and the solution's pH. When Fe(2+)/Fe(3+) are less than 100 mg/L at pH 6, Fe(2+)/Fe(3+) inhibited the NB degradation slightly, and when Fe(2+)/Fe(3+) was 100-200 mg/L, the NB degradation was enhanced. When pH was shifted to 9, Fe(2+) of lower than 100 mg/L promoted the NB degradation, and 200 mg/L Fe(2+) inhibit the NB degradation. The synergism of combined use of iron and the anaerobic sludge in treating NB wastewater was proposed, and adjusting the concentrations of Fe(2+)/Fe(3+) in the anaerobic sludge according to the pH of the wastewater could be an effective method to obtain a high removal rate of NB.  相似文献   

5.
Advanced treatment of mature landfill leachate from a municipal landfill located in southern China (Jiangmen) was carried out in a full-scale plant using a new process. The combined process has a sequencing batch reactor (SBR) serving as the primary treatment, with polyferric sulfate (PFS) coagulation coupled with a Fenton system as secondary treatment, and a pair of upflow biological aerated filters (UBAFs) in parallel as tertiary treatment. The overall removal efficiency of chemical oxygen demand (COD) in this process was 97.3%, with an effluent COD less than 100 mg/L. Up to 99% ammonia (N–NH3) removal efficiency was achieved in the SBR, with an effluent of less than 3 mg/L, which meets the discharge standard (≤25 mg/L) with only primary treatment. The total phosphorus (TP) and suspended solids (SS) in the final effluent were reduced to less than 1 mg/L and 10 mg/L, respectively. The experience gained in the operation and maintenance will lead to a more stable performance of this combined process. An economic analysis shows that the overall operating cost of the advanced treatment was $2.70/m3. This new combination process was proved to be highly compatible and efficient in a small-scale landfill leachate treatment plant and is recommended for small-scale landfill leachate treatment plants.  相似文献   

6.
The applicability of Fenton's oxidation as an advanced treatment for chemical oxygen demand (COD) and color removal from anaerobically treated poultry manure wastewater was investigated. The raw poultry manure wastewater, having a pH of 7.30 (+/-0.2) and a total COD of 12,100 (+/-910) mg/L was first treated in a 15.7 L of pilot-scale up-flow anaerobic sludge blanket (UASB) reactor. The UASB reactor was operated for 72 days at mesophilic conditions (32+/-2 degrees C) in a temperature-controlled environment with three different hydraulic retention times (HRT) of 15.7, 12 and 8.0 days, and with organic loading rates (OLR) between 0.650 and 1.783 kg COD/(m3day). Under 8.0 days of HRT, the UASB process showed a remarkable performance on total COD removal with a treatment efficiency of 90.7% at the day of 63. The anaerobically treated poultry manure wastewater was further treated by Fenton's oxidation process using Fe2+ and H2O2 solutions. Batch tests were conducted on the UASB effluent samples to determine the optimum operating conditions including initial pH, effects of H2O2 and Fe2+ dosages, and the ratio of H2O2/Fe2+. Preliminary tests conducted with the dosages of 100 mg Fe2+/L and 200 mg H2O2/L showed that optimal initial pH was 3.0 for both COD and color removal from the UASB effluent. On the basis of preliminary test results, effects of increasing dosages of Fe2+ and H2O2 were investigated. Under the condition of 400 mg Fe2+/L and 200 mg H2O2/L, removal efficiencies of residual COD and color were 88.7% and 80.9%, respectively. Under the subsequent condition of 100 mg Fe2+/L and 1200 mg H2O2/L, 95% of residual COD and 95.7% of residual color were removed from the UASB effluent. Results of this experimental study obviously indicated that nearly 99.3% of COD of raw poultry manure wastewater could be effectively removed by a UASB process followed by Fenton's oxidation technology used as a post-treatment unit.  相似文献   

7.
Sulfide removal in petroleum refinery wastewater by chemical precipitation   总被引:2,自引:0,他引:2  
Sulfide removal by chemical precipitation from petroleum refinery wastewater was investigated. The wastewater samples were taken from the flocculation pond influent of TUPRAS Kirikkale Middle Anatolia Petroleum Refinery Wastewater Treatment Plant (WWTP) and physicochemical treatments using conventional coagulants which were partial precipitant [FeCl(3) . 6H(2)O and FeSO(4) . 7H(2)O] and coagulant-aids [Ca(OH)(2) and CaCO(3)] were applied to both raw and sulfide added wastewater. Sulfide and chemical oxygen demand (COD) removal efficiencies of Fe(3+) ions alone for sulfide added wastewaters having different pH values varied between 62-95 and 45-75%, respectively. In addition, removal efficiencies of sulfide (96-99%) and COD (50-80%) were obtained by using Fe(2+) ions together with Ca(OH)(2) as precipitant-aid under the same conditions. In experiments performed with raw wastewater which had different pH values, COD removal efficiencies of Fe(3+) and Fe(2+) ions together with Ca(OH)(2), were 50-80 and 32-50%, respectively.  相似文献   

8.
Removal of trace amounts of heavy metals can be achieved by means of selective ion-exchange processes. The newly developed resins offered a high resin capacity and faster sorption kinetics for the metal ions such as Pb(2+), Cu(2+), Zn(2+), Cd(2+), and Ni(2+) ions. In the present study, the removal of Pb(2+), Cu(2+), Zn(2+), Cd(2+), and Ni(2+) ions from aqueous solutions was investigated. Experimental investigations were undertaken using the ion-exchange resin Lewatit CNP 80 (weakly acidic) and were compared with Lewatit TP 207 (weakly acidic and chelating). The optimum pH range for the ion-exchange of the above mentioned metal ions on Lewatit CNP 80 and Lewatit TP 207 were 7.0-9.0 and 4.5-5.5, respectively. The influence of pH, contact time, metal concentration and amount of ion-exchanger on the removal process was investigated. For investigations of the exchange equilibrium, different amounts of resin were contacted with a fixed volume of Pb(2+), Cu(2+), Zn(2+), Cd(2+), and Ni(2+) ion containing solution. The obtained sorption affinity sequence in the presented work was Ni(2+)>Cu(2+)>Cd(2+)>Zn(2+)>Pb(2+). The metal ion concentrations were measured by AAS methods. The distribution coefficient values for metal ions of 10(-3)M initial concentration at 0.1mol/L ionic strength show that the Lewatit CNP 80 was more selective for Ni(2+), Cu(2+) than it was for Cd(2+), Zn(2+) and Pb(2+). Langmuir isotherm was applicable to the ion-exchange process and its contents were calculated. The uptake of metal ions by the ion-exchange resins was reversible and thus has good potential for the removal of Pb(2+), Cu(2+), Zn(2+), Cd(2+), and Ni(2+) from aqueous solutions. The amount of sorbed metal ion per gram dry were calculated as 4.1, 4.6, 4.7, 4.8, and 4.7mequiv./g dry resin for Pb(2+), Cu(2+), Zn(2+), Cd(2+), and Ni(2+), respectively. Selectivity increased in the series: Cd(2+)>Pb(2+)>Cu(2+)>Ni(2+)>Zn(2+). The results obtained showed that Lewatit CNP 80 weakly acidic resin had shown better performance than Lewatit TP 207 resin for the removal of metals. The change of the ionic strength of the solution exerts a slight influence on the removal of Pb(2+), Cu(2+), Zn(2+), Cd(2+), and Ni(2+). The presence of low ionic strength or low concentration of NaNO(3) does not have a significant effect on the ion-exchange of these metals by the resins. We conclude that Lewatit CNP 80 can be used for the efficient removal of Pb(2+), Cu(2+), Zn(2+), Cd(2+), and Ni(2+) from aqueous solutions.  相似文献   

9.
This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.  相似文献   

10.
Carbon adsorption process is tested for removal of high concentration of organic mercury (thimerosal) from industrial process wastewater, in batch and continuously flow through column systems. The organic mercury concentration in the process wastewater is about 1123 mg/L due to the thimerosal compound. Four commercially available adsorbents are tested for mercury removal and they are: Calgon F-400 granular activated carbon (GAC), CB II GAC, Mersorb GAC and an ion-exchange resin Amberlite GT73. The adsorption capacity of each adsorbent is described by the Freundlich isotherm model at pH 3.0, 9.5 and 11.0 in batch isotherm experiments. Acidic pH was favorable for thimerosal adsorption onto the GACs. Columns-in-series experiments are conducted with 30-180 min empty bed contact times (EBCTs). Mercury breakthrough of 30 mg/L occurred after about 47 h (96 Bed Volume Fed (BVF)) of operation, and 97 h (197 BVF) with 120 min EBCT and 180 min EBCT, respectively. Most of the mercury removal is attributed to the 1st adsorbent column. Increase in contact time by additional adsorbent columns did not lower the effluent mercury concentration below 30 mg/L. However, at a lower influent wastewater pH 3, the mercury effluent concentration decreased to less than 7 mg/L for up to 90 h of column operation (183 BVF).  相似文献   

11.
Attempts were made in this study to examine the efficiency of Fenton process combined with coagulation for treatment of water-based printing ink wastewater. Parameters affecting the Fenton process, such as pH, dosages of Fenton reagents and the settling time, were determined by using jar test experiments. 86.4% of color and 92.4% of chemical oxygen demand (COD) could be removed at pH 4, 50mg/l H(2)O(2), 25mg/l FeSO(4) and 30min settling time. The coagulation using polyaluminium chloride (PAC) and ferrous sulfate (FeSO(4)) was beneficial to improve the Fenton process treated effluent in reducing the flocs settling time, enhancing color and COD removal. The overall color, COD and suspended solids (SS) removal reached 100%, 93.4% and 87.2% under selected conditions, respectively. Thus this study might offer an effective way for wastewater treatment of water-based ink manufacturer and printing corporation.  相似文献   

12.
The applicability of Fenton's oxidation to improve the biodegradability of a pharmaceutical wastewater to be treated biologically was investigated. The wastewater was originated from a factory producing a variety of pharmaceutical chemicals. Treatability studies were conducted under laboratory conditions with all chemicals (having COD varying from 900 to 7000 mg/L) produced in the factory in order to determine the operational conditions to utilize in the full-scale treatment plant. Optimum pH was determined as 3.5 and 7.0 for the first (oxidation) and second stage (coagulation) of the Fenton process, respectively. For all chemicals, COD removal efficiency was highest when the molar ratio of H(2)O(2)/Fe(2+) was 150-250. At H(2)O(2)/Fe(2+) ratio of 155, 0.3M H(2)O(2) and 0.002 M Fe(2+), provided 45-65% COD removal. The wastewater treatment plant that employs Fenton oxidation followed by aerobic degradation in sequencing batch reactors (SBR), built after these treatability studies provided an overall COD removal efficiency of 98%, and compliance with the discharge limits. The efficiency of the Fenton's oxidation was around 45-50% and the efficiency in the SBR system which has two reactors each having a volume of 8m(3) and operated with a total cycle time of 1 day, was around 98%, regarding the COD removal.  相似文献   

13.
Anaerobic digestion of sludge from small electrocoagulation wastewater treatment plant (SEWWTP) is described. The sludge for digestion (SEWWTP sludge) was taken from pilot-scale SEWWTP with the capacity of about 200-population equivalent (25 m3 of municipal wastewater per day). Due to the technology of wastewater treatment, the characteristics of SEWWTP sludge was different from sludge produced in conventional mechanical-biological wastewater treatment plant. Therefore, experiments were focused on possibilities of anaerobic sludge digestion and determination of conditions and parameters (amount and quality of the sludge, biogas production, etc.). Average COD removal efficiency in the pilot-scale SEWWTP exceeded 80%. Organic content of excess sludge (volatile suspended solids (VSS)) was in the range of 52.1-59.2% (these values are much lower compared to VSS content in raw sludge from conventional municipal wastewater treatment plant, where VSS is about 75%). Biogas production from anaerobic digestion of SEWWTP sludge was approximately three times lower compared to standard production in conventional municipal wastewater treatment plant. Low pH (6.5-6.7), high concentration of iron (up to 1400 mg/L) and aluminium (up to 1300 mg/L) and very low (almost zero) concentration of dissolved phosphorus in sludge water were the main factors limiting the rate of anaerobic processes. Based on these results, anaerobic digestion of SEWWTP sludge was not recommended as an appropriate stabilisation method.  相似文献   

14.
Application of Fenton oxidation to cosmetic wastewaters treatment   总被引:1,自引:0,他引:1  
The removal of organic matter (TOC and COD) from a cosmetic wastewater by Fenton oxidation treatment has been evaluated. The operating conditions (temperature as well as ferrous ion and hydrogen peroxide dosage) have been optimized. Working at an initial pH equal to 3.0, a Fe(2+) concentration of 200 mg/L and a H(2)O(2) concentration to COD initial weight ratio corresponding to the theoretical stoichiometric value (2.12), a TOC conversion higher than 45% at 25 degrees C and 60% at 50 degrees C was achieved. Application of the Fenton oxidation process allows to reach the COD regional limit for industrial wastewaters discharges to the municipal sewer system. A simple kinetic analysis based on TOC was carried out. A second-order equation describes well the overall kinetics of the process within a wide TOC conversion range covering up to the 80-90% of the maximum achievable conversion.  相似文献   

15.
Dyeing and finishing of textile yarns and fabrics are extremely important processes in terms of both quality and environmental concerns. Among the commercial textile dyes, particularly disperse dyestuffs are of environmental interest because of their widespread use, their potential for formation of toxic aromatic amines and their low removal rate during aerobic waste treatment as well as advanced chemical oxidation. Thus, in the present paper ferrous iron coagulation, ozonation and ferrous iron-catalyzed ozonation were employed at varying pH (3-13) and Fe(II)-ion doses (0.09-18mM) for the treatment of a simulated disperse dye-bath (average initial apparent color as absorbance at 566nm=815.4m(-1); COD(0)=3784mgl(-1); TOC(0)=670mgl(-1); BOD(5,0)=58mgl(-1)) that more closely resembled an actual dyehouse effluent than an aqueous disperse dye solution. Coagulation with 5000mgl(-1) FeSO4-7H2O (18mM Fe(2+)) at pH 11 removed up to 97% color and 54% COD, whereas oxidation via ozonation alone (applied ozone dose=2300mgl(-1)) was only effective at pH 3, resulting in 77% color and 11% COD removal. Fe(II)-ion-catalyzed ozonation (3.6mM Fe(2+) at pH 3; Fe(2+):O3 molar ratio 1:14) eliminated 95% color and 48% COD and appeared to be the most attractive option among the investigated chemical treatment methods as for its applicability at the natural acidic pH of the disperse dye-bath effluent and at relatively low Fe(2+)-ion doses as compared to ferrous sulfate coagulation. However, no TOC reduction was observable for ozonation and catalytic ozonation at the investigated reaction conditions (14gl(-1) O3 at pH 3). An average six-fold enhancement in the biodegradability parameter of the synthetic dye wastewater expressed in terms of the BOD(5)/COD ratio could be achieved by the investigated chemical treatment methods.  相似文献   

16.
Photochemical mineralization of di-n-butyl phthalate with H2O2/Fe3+   总被引:1,自引:0,他引:1  
This study evaluated the performance of photo-Fenton reaction initiated by the UV irradiation with H(2)O(2)/Fe(3+), denoted as UV/H(2)O(2)/Fe(3+), to decompose di-n-butyl phthalate (DBP) in the aqueous solution. The concentration of total organic carbon (TOC) was chosen as a mineralization index of the decomposition of DBP by the UV/H(2)O(2)/Fe(3+) process. A second-order kinetic model with respect to TOC was adequately adopted to represent the mineralization of DBP by the UV/H(2)O(2)/Fe(3+) process. The experimental results of this study suggested that the dosages with 4.74 x 10(-5) mol min(-1)L(-1) H(2)O(2) and initial Fe(3+) loading concentration of 4.50 x 10(-4) mol L(-1) in the solution at pH 3.0 with 120 microW cm(-2) UV (312 nm) provided the optimal operation conditions for the mineralization of DBP (5 mg L(-1)) yielding a 92.4% mineralization efficiency at 90 min reaction time.  相似文献   

17.
A variety of advanced oxidation processes (AOPs; O3/OH-, H2O2/UV, Fe2+/H2O2, Fe3+/H2O2, Fe2+/H2O2/UV and Fe3+/H2O2/UV) have been applied for the oxidative pre-treatment of real penicillin formulation effluent (average COD0 = 1395 mg/L; TOC0 = 920 mg/L; BOD(5,0) approximately 0 mg/L). For the ozonation process the primary involvement of free radical species such as OH* in the oxidative reaction could be demonstrated via inspection of ozone absorption rates. Alkaline ozonation and the photo-Fenton's reagents both appeared to be the most promising AOPs in terms of COD (49-66%) and TOC (42-52%) abatement rates, whereas the BOD5 of the originally non-biodegradable effluent could only be improved to a value of 100 mg/L with O3/pH = 3] treatment (BOD5/COD, f = 0.08). Evaluation on COD and TOC removal rates per applied active oxidant (AOx) and oxidant (Ox) on a molar basis revealed that alkaline ozonation and particularly the UV-light assisted Fenton processes enabling good oxidation yields (1-2 mol COD and TOC removal per AOx and Ox) by far outweighed the other studied AOPs. Separate experimental studies conducted with the penicillin active substance amoxicillin trihydrate indicated that the aqueous antibiotic substance can be completely eliminated after 40 min advanced oxidation applying photo-Fenton's reagent (pH = 3; Fe(2+):H2O2 molar ratio = 1:20) and alkaline ozonation (at pH = 11.5), respectively.  相似文献   

18.
利用粉煤灰、黏土、脱水污泥和碳酸钙等原料制备粉煤灰陶粒。通过正交试验确定原料的最优配比,并对自制陶粒进行了性能表征,进一步利用自制曝气生物滤池装置,通过改变运行参数,测试了自制陶粒用作曝气生物滤池填料处理城市污水的效果。结果表明:自制陶粒填料各项性能都符合相关标准;化学需氧量(COD)、总氮(TN)去除率随着水力停留时间(HRT)的增加而增加,当HRT为4h时,总磷(TP)去除率达到最大;低温不利于TN、TP的去除,温度对COD去除率影响不大;当进水中的TN含量为30mg/L时,TN去除率最大。TP去除率随着进水中的TP含量的增加而增加,进水浓度对COD去除率影响不大。  相似文献   

19.
A novel activation process was adopted to produce highly porous activated carbon from cyclic activated sludge in secondary precipitator in municipal wastewater treatment plant for dye removal from colored wastewater. The physical properties of activated carbon produced with the activation of 3M KOH solution in the atmosphere of steam were investigated. Adsorption removal of a dye, Acid Brilliant Scarlet GR, from aqueous solution onto the sludge-based activated carbon was studied under varying conditions of adsorption time, initial concentration, carbon dosage and pH. Adsorption equilibrium was obtained in 15 min for the dye initial concentration of 300 mg/L. Initial pH of solution had an insignificant impact on the dye removal. Results indicated that 99.7% coloration and 99.6% total organic carbon (TOC) were removed after 15 min adsorption in the synthetic solution of Acid Brilliant Scarlet GR with initial concentration of 300 mg/L of the dye and 20 g/L activated carbon. The Langmuir and Freundlich equilibrium isotherm models fitted the adsorption data well with R(2)=0.996 and 0.912, respectively. Accordingly, it is concluded that the procedure of developing activated carbon used in this study could be effective and practical for utilizing in dye wastewater treatment.  相似文献   

20.
Advanced treatment of coking wastewater was investigated experimentally with coagulation and zero-valent iron (ZVI) processes. Particular attention was paid to the effect of dosage and pH on the removal of chemical oxygen demand (COD) in the two processes. The results showed that ZVI was more effective than coagulation for advanced treatment of coking wastewater. The jar tests revealed that maximal COD removal efficiency of 27.5-31.8% could be achieved under the optimal condition of coagulation, i.e. 400mg/L of Fe(2)(SO(4))3 as coagulant at pH 3.0-5.0. On the other hand, the COD removal efficiency could be up to 43.6% under the idealized condition of ZVI upon 10 g/L active carbon and 30 g/L iron being dosed at pH 4.0. The mechanisms for COD removal in ZVI were dominated by coagulation, precipitation and oxidation-reduction. ZVI would also enhance the biodegradability of effluent by increasing BOD5/COD from 0.07 to 0.53. Moreover, some ester compounds could be produced in the reaction. Although ZVI was found more efficient than coagulation in eliminating low molecular weight (<2000 Da) compounds in the wastewater, there were still a few residual contaminants which could hardly be eliminated by either of the process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号