首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The real-time uptake of serotonin, a neurotransmitter, by rat leukemia mast cell line RBL-2H3 and 5-hydroxytryptophan by Chinese hamster V79 cells has been studied by fluorescence lifetime imaging microscopy (FLIM), monitoring ultraviolet (340 nm) fluorescence induced by two-photon subpicosecond 630 nm excitation. Comparison with two-photon excitation with 590 nm photons or by three-photon excitation at 740 nm shows that the use of 630 nm excitation provides optimal signal intensity and lowered background from auto-fluorescence of other cellular components. In intact cells, we observe using FLIM three distinct fluorescence lifetimes of serotonin and 5-hydroxytryptophan according to location. The normal fluorescence lifetimes of both serotonin (3.8 ns) and 5-hydroxytryptophan (3.5 ns) in solution are reduced to approximately 2.5 ns immediately on uptake into the cell cytosol. The lifetime of internalized serotonin in RBL-2H3 cells is further reduced to approximately 2.0 ns when stored within secretory vesicles.  相似文献   

2.
Ulrich V  Fischer P  Riemann I  Königt K 《Scanning》2004,26(5):217-225
An inverted fluorescence microscope was upgraded into a compact three-dimensional laser scanning microscope (LSM) of 65 x 62 x 48 cm dimensions by means of a fast kHz galvoscanner unit, a piezodriven z-stage, and a picosecond (ps) 50 MHz laser diode at 405 nm. In addition, compact turn-key near infrared femtosecond lasers have been employed to perform multiphoton fluorescence and second harmonic generation (SHG) microscopy. To expand the features of the compact LSM, a time-correlated single photon counting unit as well as a Sagnac interferometer have been added to realize fluorescence lifetime imaging (FLIM) and spectral imaging. Using this unique five-dimensional microscope, TauMap, single-photon excited (SPE), and two-photon excited (TPE) cellular fluorescence as well as intratissue autofluorescence of water plant leaves have been investigated with submicron spatial resolution, <270 ps temporal resolution, and 10 nm spectral resolution.  相似文献   

3.
Long-term high-resolution multiphoton imaging of nonlabeled human salivary gland stem cell spheroids has been performed with submicron spatial resolution, 10.5-nm spectral resolution, and picosecond temporal resolution. In particular, the two-photon-excited coenzyme NAD(P)H and flavins have been detected by time-correlated single photon counting (TCSPC). Stem cells increased their autofluorescence lifetimes and decreased their total fluorescence intensity during the adipogenic-differentiation process. In addition, the onset of the biosynthesis of lipid vacuoles was monitored over a period of several weeks in stem-cell spheroids. Time-resolved multiphoton autofluorescence imaging microscopes may become a promising tool for marker-free stem-cell characterization and cell sorting.  相似文献   

4.
In this paper a detailed discussion is presented of the factors that affect the fluorescence lifetime imaging performance of a scanning microscope equipped with a single photon counting based, two‐ to eight‐channel, time‐gated detection system. In particular we discuss the sensitivity, lifetime resolution, acquisition speed, and the shortest lifetimes that can be measured. Detection systems equipped with four to eight time‐gates are significantly more sensitive than the two time‐gate system. Only minor sensitivity differences were found between systems with four or more time‐gates. Experiments confirm that the lifetime resolution is dominated by photon statistics. The time response of the detector determines the shortest lifetimes that can be resolved; about 25 ps for fast MCP‐PMTs and 300–400 ps for other detectors. The maximum count rate of fast MCP‐PMTs, however, is 10–100 times lower than that of fast PMTs. Therefore, the acquisition speed with MCP‐PMT based systems is limited. With a fast PMT operated close to its maximum count rate we were able to record a fluorescence lifetime image of a beating myocyte in less than one second.  相似文献   

5.
In vivo and in vitro multiphoton imaging was used to perform high resolution optical sectioning of human hair by nonlinear excitation of endogenous as well as exogenous fluorophores. Multiphoton fluorescence lifetime imaging (FLIM) based on time-resolved single photon counting and near-infrared femtosecond laser pulse excitation was employed to analyze the various fluorescent hair components. Time-resolved multiphoton imaging of intratissue pigments has the potential (i) to identify endogenous keratin and melanin, (ii) to obtain information on intrahair dye accumulation, (iii) to study bleaching effects, and (iv) to monitor the intratissue diffusion of pharmaceutical and cosmetical components along hair shafts.  相似文献   

6.
Two-photon fluorescence lifetime imaging microscopy was used noninvasively to monitor a fluorescent antigen during macrophage-mediated endocytosis, intracellular vacuolar encapsulation, and protease-dependent processing. Fluorescein-conjugated bovine serum albumin (FITC–BSA) served as the soluble exogenous antigen. As a relatively nonfluorescent probe in the native state, the antigen was designed to reflect sequential intracellular antigen processing events through time-dependent changes in fluorescence properties. Using two-photon lifetime imaging microscopy, antigen processing events were monitored continuously for several hours. During this time, the initial fluorescein fluorescence lifetime of 0.5 ns increased to α 3.0 ns. Control experiments using fluorescein conjugated poly- l -lysine and poly- d -lysine demonstrated that the increase in fluorescence parameters observed with FITC–BSA were due to intracellular proteolysis since addition of the inert d -isomer did not promote an increase in fluorescence lifetime or intensity. Comparisons of intravacuolar and extracellular FITC–dextran concentration suggested active localization of dextran in the vacuoles by the macrophage. In addition, the kinetics of degradation observed using two-photon microscopy were similar to results obtained on the flow cytometer, thus validating the use of flow cytometry for future studies.  相似文献   

7.
Fluorescence lifetime imaging (FLIM) is a powerful microscopy technique for providing contrast of biological and other systems by differences in molecular species or their environments. However, the cost of equipment and the complexity of data analysis have limited the application of FLIM. We present a mathematical model and physical implementation for a low cost digital frequency domain FLIM (DFD-FLIM) system, which can provide lifetime resolution with quality comparable to time-correlated single photon counting methods. Our implementation provides data natively in the form of phasors. On the basis of the mathematical model, we present an error analysis that shows the precise parameters for maximizing the quality of lifetime acquisition, as well as data to support this conclusion. The hardware and software of the proposed DFD-FLIM method simplifies the process of data acquisition for FLIM, presents a new interface for data display and interpretation, and optimizes the accuracy of lifetime determination.  相似文献   

8.
We develop a multidimensional fluorescence imaging technique by implementing a wide-field time-gated fluorescence lifetime imaging into digital scanned laser light-sheet microscopy (FLIM-DSLM) to measure 3D fluorescence lifetime distribution in mesoscopic specimens with high resolution. This is achieved by acquiring a series of time-gated images at different relative time delays with respect of excitation pulses at different depths. The lifetime is determined for each voxel by iteratively fitting to single exponential decay. The performance of the developed system is evaluated with the measurements of a lifetime reference Rhodamine 6G solution and a subresolution fluorescent bead phantom. We also demonstrate the application performances of this system to ex vivo and in vivo imaging of Tg(kdrl:EGFP) transgenic zebrafish embryos, illustrating the lifetime differences between the GFP signal and the autofluorescence signal. The results show that FLIM-DSLM can be used for sample size up to a few millimetres and can be utilised as a powerful and robust method for biomedical research, for example as a readout of protein–protein interactions via Förster resonance energy transfer.  相似文献   

9.
Cheng  Pan  Shih  Kim  Liou  Park 《Journal of microscopy》1998,189(3):199-212
A new generation of efficient two-photon absorbing fluorescent molecules has been developed and used effectively for two-photon laser scanning microscopy. Several examples of the use of these new fluorophores have been presented. In addition, issues relating to the two-photon absorption cross-section, excitation power, sample properties and resolution in two-photon laser scanning microscopy are discussed.  相似文献   

10.
A whole-field time-domain fluorescence lifetime imaging (FLIM) microscope with the capability to perform optical sectioning is described. The excitation source is a mode-locked Ti:Sapphire laser that is regeneratively amplified and frequency doubled to 415 nm. Time-gated fluorescence intensity images at increasing delays after excitation are acquired using a gated microchannel plate image intensifier combined with an intensified CCD camera. By fitting a single or multiple exponential decay to each pixel in the field of view of the time-gated images, 2-D FLIM maps are obtained for each component of the fluorescence lifetime. This FLIM instrument was demonstrated to exhibit a temporal discrimination of better than 10 ps. It has been applied to chemically specific imaging, quantitative imaging of concentration ratios of mixed fluorophores and quantitative imaging of perturbations to fluorophore environment. Initially, standard fluorescent dyes were studied and then this FLIM microscope was applied to the imaging of biological tissue, successfully contrasting different tissues and different states of tissue using autofluorescence. To demonstrate the potential for real-world applications, the FLIM microscope has been configured using potentially compact, portable and low cost all-solid-state diode-pumped laser technology. Whole-field FLIM with optical sectioning (3D FLIM) has been realized using a structured illumination technique.  相似文献   

11.
We present combined epi-coherent anti-Stokes Raman scattering (CARS) and multiphoton imaging with both chemical discrimination and subcellular resolution on human skin in vivo. The combination of both image modalities enables label-free imaging of the autofluorescence of endogenous fluorophores by two-photon excited fluorescence, as well as imaging of the distribution of intercellular lipids, topically applied substances and water by CARS. As an example for medical imaging, we investigated healthy and psoriasis-affected human skin with both image modalities in vivo and found indications for different lipid distributions on the cellular level.  相似文献   

12.
Multiple frequency fluorescence lifetime imaging microscopy   总被引:3,自引:0,他引:3  
The experimental configuration and the computational algorithms for performing multiple frequency fluorescence lifetime imaging microscopy (mfFLIM) are described. The mfFLIM experimental set‐up enables the simultaneous homodyne detection of fluorescence emission modulated at a set of harmonic frequencies. This was achieved in practice by using monochromatic laser light as an excitation source modulated at a harmonic set of frequencies. A minimum of four frequencies were obtained by the use of two standing wave acousto‐optic modulators placed in series. Homodyne detection at each of these frequencies was performed simultaneously by mixing with matching harmonics present in the gain characteristics of a microchannel plate (MCP) image intensifier. These harmonics arise as a natural consequence of applying a high frequency sinusoidal voltage to the photocathode of the device, which switches the flow of photoelectrons ‘on’ and ‘off’ as the sinus voltage swings from negative to positive. By changing the bias of the sinus it was possible to control the duration of the ‘on’ state of the intensifier relative to its ‘off’ state, enabling the amplitude of the higher harmonic content in the gain to be controlled. Relative modulation depths of 400% are theoretically possible from this form of square‐pulse modulation. A phase‐dependent integrated image is formed by the sum of the mixed frequencies on the phosphor of the MCP. Sampling this signal over a full period of the fundamental harmonic enables each harmonic to be resolved, provided that the Nyquist sampling criterion is satisfied for the highest harmonic component in the signal. At each frequency both the phase and modulation parameters can be estimated from a Fourier analysis of the data. These parameters enable the fractional populations and fluorescence lifetimes of individual components of a complex fluorescence decay to be resolved on a pixel‐by‐pixel basis using a non‐linear fit to the dispersion relationships. The fitting algorithms were tested on a simulated data set and were successful in disentangling two populations having 1 ns and 4 ns fluorescence lifetimes. Spatial invariance of the lifetimes was exploited to improve the accuracy significantly. Multiple frequency fluorescence lifetime imaging microscopy was then successfully applied to resolve the fluorescence lifetimes and fluorescence intensity contributions in a rhodamine dye mixture in solution, and green fluorescent protein variants co‐expressed in live cells.  相似文献   

13.
Video-rate fluorescence lifetime-resolved imaging microscopy (FLIM) is a quantitative imaging technique for measuring dynamic processes in biological specimens. FLIM offers valuable information in addition to simple fluorescence intensity imaging; for instance, the fluorescence lifetime is sensitive to the microenvironment of the fluorophore allowing reliable differentiation between concentration differences and dynamic quenching. Homodyne FLIM is a full-field frequency-domain technique for imaging fluorescence lifetimes at every pixel of a fluorescence image simultaneously. If a single modulation frequency is used, video-rate image acquisition is possible. Homodyne FLIM uses a gain-modulated image intensified charge-coupled device (ICCD) detector, which unfortunately is a major contribution to the noise of the measurement. Here we introduce image analysis for denoising homodyne FLIM data. The denoising routine is fast, improves the extraction of the fluorescence lifetime value(s) and increases the sensitivity and fluorescence lifetime resolving power of the FLIM instrument. The spatial resolution (especially the high spatial frequencies not related to noise) of the FLIM image is preserved, because the denoising routine does not blur or smooth the image. By eliminating the random noise known to be specific to photon noise and from the intensifier amplification, the fidelity of the spatial resolution is improved. The polar plot projection, a rapid FLIM analysis method, is used to demonstrate the effectiveness of the denoising routine with exemplary data from both physical and complex biological samples. We also suggest broader impacts of the image analysis for other fluorescence microscopy techniques (e.g. super-resolution imaging).  相似文献   

14.
A theory for multiphoton fluorescence imaging in high aperture scanning optical microscopes employing finite sized detectors is presented. The effect of polarisation of the fluorescent emission on the imaging properties of such microscopes is investigated. The lateral and axial resolutions are calculated for one-, two- and three-photon excitation of p-quaterphenyl for high and low aperture optical systems. Significant improvement in lateral resolution is found to be achieved by employing a confocal pinhole. This improvement increases with the order of the multiphoton process. Simultaneously, it is found that, when the size of the pinhole is reduced to achieve the best possible resolution, the signal-to-noise ratio is not degraded by more than 30%. The degree of optical sectioning achieved is found to improve dramatically with the use of confocal detection. For two- and three-photon excitation axial full width half-maximum improvement of 30% is predicted.  相似文献   

15.
Graphical representation of fluorescence lifetime imaging microscopy data demonstrates that a mixture of two components with single exponential decays can be resolved by single frequency measurements. We derive a method based on linear fitting that allows the calculation of the fluorescence lifetimes of the two components. We show that introduction of proper error‐weighting results in a non‐linear method that is mathematically identical to a global analysis algorithm that was recently derived. The graphical approach was applied to cellular data obtained from a lifetime‐based phosphorylation assay for the epidermal growth factor receptor and yielded results similar to those obtained by a global analysis algorithm.  相似文献   

16.
It is demonstrated that fluorescence lifetimes in the nanosecond and picosecond time-scale range can be observed with the recently proposed double-pulse fluorescence lifetime imaging technique (Müller et al. , 1995, Double-pulse fluorescence lifetime imaging in confocal microscopy. J. Microsc 177, 171–179).
A laser source with an optical parametric amplifier (OPA) system is used to obtain short pulse durations needed for high time resolution, wavelength tunability for selective excitation of specific fluorophores and high pulse energies to obtain (partial) saturation of the optical transition.
It is shown that fluorescence lifetimes can be determined correctly also with nonuniform saturation conditions over the observation area.
A correction scheme for the effect on the measurements of laser power fluctuations, which are inherently present in OPA systems, is presented. Measurements on bulk solutions of Rhodamine B and Rhodamine 6G in different solvents confirm the experimental feasibility of accessing short fluorescence lifetimes with this technique.
Because signal detection does not require fast electronics, the technique can be readily used for fluorescence lifetime imaging in confocal microscopy, especially when using bilateral scanning and cooled CCD detection.  相似文献   

17.
A scanning‐less single‐photon counting system for FLIM and fluorescence anisotropy wide‐field imaging is described and characterized in this paper. The two polarizations of the fluorescence are divided by a Glan prism and acquired at the same time by the QA detector. Fluorescence decay profiles can be reconstructed for any desired area up to each pixel and used to calculate time‐resolved fluorescence anisotropy decays.  相似文献   

18.
Jiang X  Zhong J  Liu Y  Yu H  Zhuo S  Chen J 《Scanning》2011,33(1):53-56
Multiphoton microscopic imaging of collagen plays an important role in noninvasive diagnoses of human tissue. In this study, two-photon fluorescence and second-harmonic generation (SHG) imaging of collagen in human skin dermis and submucosa of colon and stomach tissues were investigated based on multiphoton microscopy (MPM). Our results show that multiphoton microscopic image of collagen bundles exhibits apparently different pattern in human tissues. The collagen bundles can simultaneously reveal its SHG and two-photon excited fluorescence images in the submucosa of colon and stomach, whereas it solely emit SHG signal in skin dermis. The intensity spectral information from tissues further demonstrated the above results. This indicates that collagen bundles have completely different space arrangement in these tissues. Our experimental results bring more detailed information of collagen for the application of MPM in human noninvasive imaging.  相似文献   

19.
Many multiphoton imaging applications would benefit from a larger field of view; however, large field of views (>mm) require low magnification objectives which have low light collection efficiencies. We demonstrate a light collection system mounted on a low magnification objective that increases fluorescence collection by as much as 20-fold in scattering tissues. This peripheral detector results in an effective numerical aperture of collection >0.8 with a 3-4 mm field of view.  相似文献   

20.
The integration of fibre optics into an imaging system for the convenient delivery and collection of light has resulted in many hybrid forms of novel biomedical optical instrumentation. Although it is extremely robust and cost effective, fibre integration requires special consideration in a time‐domain fluorescence lifetime imaging schema where multipath propagation in the fibre causes significant spread in photon transit times. In this study, we investigated the effect of the length of a multimode collection fibre on the temporal performance of a multichannel fluorescence lifetime microscope and demonstrated the effectiveness of a photonic crystal fibre as a means of optimizing the collection and delivery of emitted fluorescence in terms of temporal resolution. The findings are pertinent to all studies that employ a multimode optical fibre to collect and deliver an emitted fluorescence signal from a sample to a remote detector for measurement of the characteristic fluorescence lifetime.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号