首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Fernando NL  Fedorak PM 《Water research》2005,39(19):4597-4608
In 1976, the activated sludge sewage treatment plant in Edmonton, Canada, was surveyed to determine the numbers of culturable airborne microorganisms. Many changes have been made at the plant to reduce odors and improve treatment efficiency, so in 2004 another survey was done to determine if these changes had reduced the bioaerosols. Covering the grit tanks and primary settling tanks greatly reduced the numbers of airborne microbes. Changing the design and operation of indoor automated sampling taps and sinks also reduced bioaerosols. The secondary was expanded and converted from a conventional activated sludge process using coarse bubble aeration to a biological nutrient removal system using fine bubble aeration. Although the surface area of the secondary more than doubled, the average number of airborne microorganisms in this part of the plant in 2004 was about 1% of that in 1976.  相似文献   

2.
Six different wastewater treatment plants were monitored in order to identify the main bioaerosol sources and to evaluate the effect of the aeration system used in the biological treatment (air diffusion, horizontal rotors and surface turbine aerators) on the airborne microorganism levels to which workers may be exposed. Air samples were collected by using a single stage impactor. Total count of mesophilic bacteria was used as the monitoring parameter to compare the impact of the aeration system on generic bacterial bioaerosols rather than a quantitative estimation for pathogens or fecal indicator microbes. In this study, pre-treatment, biological treatment and sludge thickening were the processes that generated the highest amount of bioaerosols. Aeration systems involving mechanical agitation of the wastewater, such as horizontal rotors and surface turbines, generated a larger amount of bioaerosols (between 450 and 4580CFU/m(3)) than air diffuser aerators (between 22 and 57CFU/m(3)). The levels of airborne bacteria generated by air diffusers were very similar to those registered at the background locations (lower than 50CFU/m(3)), unaffected by the activities taking place in the wastewater treatment plant. The use of air diffusers as an aeration system for the biological treatment would significantly minimise the potential biological hazard that wastewater treatment plant workers may be exposed to.  相似文献   

3.
Karra S  Katsivela E 《Water research》2007,41(6):1355-1365
Measurements were conducted at a Mediterranean site (latitude 35 degrees 31' north and longitude 24 degrees 03' east) during summer, to study the concentration of microorganisms emitted from a wastewater treatment plant under intensive solar radiation (520-840 W/m2) and at elevated air temperatures (25-31 degrees C). Air samples were taken with the Air Sampler MAS 100 (Merck) at each stage of an activated-sludge wastewater treatment (pretreatment, primary settling tanks, aeration tanks, secondary settling tanks, chlorination, and sludge processors). Cultivation methods based on the viable counts of mesophilic heterotrophic bacteria, as well as of indicator microorganisms of faecal contamination (total and faecal coliforms and enterococci), and fungi were performed. During air sampling, temperature, solar radiation, relative humidity and wind speed were measured. The highest concentrations of airborne microorganisms were observed at the aerated grit removal of wastewater at the pretreatment stage. A gradual decrease of bioaerosol emissions was observed during the advanced wastewater treatment from the pretreatment to the primary, secondary and tertiary treatment (97.4% decrease of mesophilic heterotrophic bacteria, and 100% decrease of total coliforms, faecal coliforms and enterococci), 95.8% decrease of fungi. The concentration of the airborne microorganisms at the secondary and tertiary treatment of the wastewater was lower than in the outdoor control. At the same time, the reduction of the microbial load at the waste sludge processors was 19.7% for the mesophilic heterotrophic bacteria, 99.4% for the total coliforms, and 100% for the faecal coliforms and the enterococci, 84.2% for the fungi. The current study concludes that the intensive solar radiation, together with high ambient temperatures, as well as optimal wastewater treatment are the most important factors for low numbers of microbes in the air.  相似文献   

4.
Micro-organisms and organic compounds of biogenic or anthropogenic origins are important constituents of atmospheric aerosols, which are involved in atmospheric processes and climate change. In order to investigate the role of fungi and their metabolisation activity, we collected airborne fungi using a biosampler in an urban location of Montreal, Quebec, Canada (45 degrees 28' N, 73 degrees 45' E). After isolation on Sabouraud dextrose agar, we exposed isolated colonies to dicarboxylic acids (C(2)-C(7)), a major group of organic aerosols and monitored their growth. Depending on the acid, total fungi numbers varied from 35 (oxalic acid) to 180 CFU/mL (glutaric acid). Transformation kinetics of malonic acid, presumably the most abundant dicarboxylic acid, at concentrations of 0.25 and 1.00 mM for isolated airborne fungi belonging to the genera Aspergillus, Penicillium, Eupenicillium, and Thysanophora with the fastest transformation rate are presented. The initial concentration was halved within 4.5 and 11.4 days. Other collected fungi did not show a significant degradation and the malonic acid concentration remained unchanged (0.25 and 1.00 mM) within 20 days. Degradation of acid with formation of metabolites was followed using high performance liquid chromatography-ultraviolet detection (HPLC/UV) and gas chromatography-mass spectrometry (GC/MS), as well as monitoring of (13)C labelled malonic acid degradation with solid-state nuclear magnetic resonance spectroscopy (NMR). Using GC/MS we identified two processes driving chemical modifications of organic aerosol solutions: (I) formation of metabolites within several days, and (II) rapid release (< or =2 min) of organic molecules from fungal species upon the insertion of taxa in organic aerosol solutions. Metabolites included aromatic compounds and alcohols (e.g. trimethylbenzene and butanol). Potential atmospheric implications of our results are discussed.  相似文献   

5.
Efforts to reduce the deliberate use of mercury (Hg) in modern industrialized societies have been largely successful, but the minimization and control of Hg in waste streams are of continuing importance. Municipal wastewater treatment plants are collection points for domestic, commercial, and industrial wastewaters, and Hg removal during wastewater treatment is essential for protecting receiving waters. Subsequent control of the Hg removed is also necessary to preclude environmental impacts. We present here a mass balance for Hg at a large metropolitan wastewater treatment plant that has recently been upgraded to provide for greater control of the Hg entering the plant. The upgrade included a new fluidized bed sludge incineration facility equipped with activated carbon addition and baghouse carbon capture for the removal of Hg from the incinerator offgas. Our results show that Hg discharges to air and water from the plant represented less than 5% of the mass of Hg entering the plant, while the remaining Hg was captured in the ash/carbon residual stream exiting the new incineration process. Sub-optimum baghouse operation resulted in some of the Hg escaping collection there and accumulating with the ash/carbon particulate matter in the secondary treatment tanks. Overall, the treatment process is effective in removing Hg from wastewater and sequestering it in a controllable stream for secure disposal.  相似文献   

6.
The aim of this study was to quantify the amount of polybrominated diphenyl ethers (PBDEs) released into the environment (biosolids, effluent) from a conventional Australian activated sludge treatment wastewater treatment plant (WWTP). The concentration of PBDE congeners was measured at various treatment stages and included four aqueous samples (raw, primary, secondary and tertiary effluents) and three sludges (primary, secondary and lime stabilized biosolids), collected at three sampling events over the course of the experiment (29 days). Semi-permeable membrane devices (SPMDs) were also installed for the duration of the experiment, the first time that SPMDs have been used to measure PBDEs in a WWTP. Over 99% of the PBDEs entering the WWTP were removed through the treatment processes, principally by sedimentation. The main congeners detected were BDE 47, 99 and 209, which are characteristic of the two major commercial formulations viz penta-BDE and deca-BDE. All the PBDE congeners measured were highly correlated with each other, suggesting a similar origin. In this case, the PBDEs are thought to be from domestic sources since domestic wastewater is the main contribution to the in-flow (∼ 95%). The mean concentration of ΣPBDEs in chemically stabilized sewage sludge (biosolids) was 300 μg kg− 1 dry weight. It is calculated that 2.3 ± 0.3 kg of PBDEs are disposed of each year with biosolids generated from the WWTP. If all Australian sewage sludge is contaminated to at least this concentration then at least 110 kg of PBDEs are associated with Australian sewage sludge annually. Less than 10 g are released annually into the environment via ocean outfall and field irrigation; this level of contamination is unlikely to pose risk to humans or the environment. The environmental release of treated effluent and biosolids is not considered a large source of PBDE environmental emissions compared to the quantities used annually in Australia.  相似文献   

7.
The total, ammonia-oxidizing, and denitrifying Bacteria in a full-scale membrane bioreactor (MBR) were evaluated monthly for over one year. Microbial communities were analyzed by denaturing gradient gel electrophoresis (DGGE) and clone library analysis of the 16S rRNA and ammonia monooxygenase (amoA) and nitrous oxide reductase (nosZ) genes. The community fingerprints obtained were compared to those from a conventional activated sludge (CAS) process running in parallel treating the same domestic wastewater. Distinct DGGE profiles for all three molecular markers were observed between the two treatment systems, indicating the selection of specific bacterial populations by the contrasting environmental and operational conditions. Comparative 16S rRNA sequencing indicated a diverse bacterial community in the MBR, with phylotypes from the α- and β-Proteobacteria and Bacteroidetes dominating the gene library. The vast majority of sequences retrieved were not closely related to classified organisms or displayed relatively low levels of similarity with any known 16S rRNA gene sequences and thus represent organisms that constitute new taxa. Similarly, the majority of the recovered nosZ sequences were novel and only moderately related to known denitrifiers from the α- and β-Proteobacteria. In contrast, analysis of the amoA gene showed a remarkably simple ammonia-oxidizing community with the detected members almost exclusively affiliated with the Nitrosomonas oligotropha lineage. Major shifts in total bacteria and denitrifying community were detected and these were associated with change in the external carbon added for denitrification enhancement. In spite of this, the MBR was able to maintain a stable process performance during that period. These results significantly expand our knowledge of the biodiversity and population dynamics of microorganisms in MBRs for wastewater treatment.  相似文献   

8.
A comparison study of novel collection methods for airborne bacteria and endotoxin was performed in an environmentally controlled chamber and in pilot-field studies. Airborne particulate matter was collected in swirling liquid impingers, air-monitoring filter cassettes, and with a micro-orifice uniform deposit impactor (MOUDI) to evaluate aerodynamic particle size distributions. Environmentally controlled chamber studies showed that impingers and MOUDI recovered significantly more airborne bacteria than filter cassettes, whereas collection methods for airborne endotoxin were not significantly different. In addition, total airborne bacteria and endotoxin concentrations were measured indoors and outdoors at three homes in Boulder, CO during winter and summer seasons. Indoor concentrations collected with the three different samplers were significantly different for airborne endotoxin, but not for airborne bacteria. Total airborne bacteria indoors and outdoors significantly varied with seasons. Outdoor airborne endotoxin significantly varied with season; no seasonal variation was seen for indoor airborne endotoxin. Indoor and outdoor levels were not significantly different for both airborne bacteria and endotoxin. The largest proportion of endotoxin was associated with airborne particulate matter <1 microm. PRACTICAL IMPLICATIONS: This study compared sampling methods for airborne endotoxin, a potent and nonspecific immune system stimulant which can induce negative health responses. The data from this study showed that swirling liquid impingers and the micro-orifice uniform deposit impactor (MOUDI) recovered significantly more airborne endotoxin than the more widely adapted method of collecting airborne endotoxin on membrane filters, when collection methods were applied in realistic settings (homes). The MOUDI measured the particle size distribution of airborne endotoxin, which can be useful for determining endotoxin respiratory toxicity and its health effects.  相似文献   

9.
Adjustment of the indoor air temperature and relative humidity set points for energy conservation is adopted in many air-conditioned offices in the subtropics. This study examines the environmental risks in an air-conditioned office with a ‘readjusted’ thermal environment from the perspective of the probable airborne bacteria level exceeding certain limits. In particular, a cross-sectional study of bacteria concentrations in 422 air-conditioned offices in Hong Kong was conducted, and a mathematical expression was proposed to correlate the indoor bacteria level with the indoor air temperature and relative humidity in an air-conditioned office. With the proposed correlation, the probability of an air-conditioned office having an unsatisfactory airborne bacteria level could be determined. The model results were verified with the measurement results from some other studies. This model would be a useful tool for preliminary assessment of the environmental risks, regarding the airborne bacteria level while balancing some energy conservation measures, in an air-conditioned office in the subtropics. The study also provides a template for developing an environmental risk assessment model in air-conditioned spaces elsewhere.  相似文献   

10.
In the present study, indoor and outdoor air samples were collected using four types of air samplers often used for airborne bacterial sampling. These air samplers included two solid impactors (BioStage and RCS), one liquid impinger (BioSampler), and one filter sampler with two kinds of filters (a gelatin and a cellulose acetate filter). The collected air samples were further processed to analyze the diversity and abundance of culturable bacteria and total bacteria through standard culture techniques, denaturing gradient gel electrophoresis (DGGE) fingerprinting and quantitative polymerase chain reaction (qPCR) analysis.The DGGE analysis indicated that the air samples collected using the BioStage and RCS samplers have higher culturable bacterial diversity, whereas the samples collected using the BioSampler and the cellulose acetate filter sampler have higher total bacterial diversity. To obtain more information on the sampled bacteria, some gel bands were excised and sequenced. In terms of sampling efficiency, results from the qPCR tests indicated that the collected total bacterial concentration was higher in samples collected using the BioSampler and the cellulose acetate filter sampler.In conclusion, the sampling bias and efficiency of four kinds of air sampling systems were compared in the present study and the two solid impactors were concluded to be comparatively efficient for culturable bacterial sampling, whereas the liquid impactor and the cellulose acetate filter sampler were efficient for total bacterial sampling.  相似文献   

11.
Little is known about the microbial selectivity of UV treatment for antibiotic resistant bacteria, and the results of limited studies are conflicting. To understand the effect of UV disinfection on antibiotic resistant bacteria, both total heterotrophic bacteria and antibiotic resistant bacteria (including cephalexin-, ciprofloxacin-, erythromycin-, gentamicin-, vancomycin-, sulfadiazine-, rifampicin-, tetracycline- and chloramphenicol-resistant bacteria) were examined in secondary effluent samples from a municipal wastewater treatment plant. Bacteria resistant to both erythromycin and tetracycline were chosen as the representative of multiple-antibiotic-resistant bacteria and their characteristics after UV treatment were also investigated.  相似文献   

12.
Huang JJ  Hu HY  Tang F  Li Y  Lu SQ  Lu Y 《Water research》2011,45(9):2775-2781
Reports state that chlorination of drinking water and wastewater affects the proportions of antibiotic-resistant bacteria by potentially assisting in microbial selection. Studies on the effect of chlorination on like species of antibiotic-resistant bacteria, however, have shown to be conflicting; furthermore, few studies have inspected the regrowth or reactivation of antibiotic-resistant bacteria after chlorination in wastewater. To understand the risks of chlorination resulting from potentially selecting for antibiotic-resistant bacteria, inactivation and reactivation rates of both total heterotrophic bacteria and antibiotic-resistant bacteria (including penicillin-, ampicillin-, tetracycline-, chloramphenicol-, and rifampicin-resistant bacteria) were examined after chlorinating secondary effluent samples from a municipal wastewater treatment plant in this study.Our experimental results indicated similar inactivation rates of both total heterotrophic bacteria and antibiotic-resistant bacteria. Microbial community composition, however, was affected by chlorination: treating samples with 10 mg Cl2/L for 10 min resulted in chloramphenicol-resistant bacteria accounting for nearly 100% of the microbial population in contrast to 78% before chlorination. This trend shows that chlorination contributes to selection of some antibiotic-resistant strains. Reactivation of antibiotic-resistant bacteria occurred at 2.0 mg Cl2/L for 10 min; specifically, chloramphenicol-, ampicillin-, and penicillin-resistant bacteria were the three prevalent groups present, and the reactivation of chloramphenicol-resistant bacteria exceeded 50%. Regrowth and reactivation of antibiotic-resistant bacteria in secondary effluents after chlorination with a long retention time could threaten public health security during wastewater reuse.  相似文献   

13.
Qinglong Wu 《Water research》2009,43(4):1101-5488
Procedures to extract and count sludge viruses-like particles from municipal sewage treatment plant were optimized by epifluorescence microscopy using SYBR Green I as a stain. The highest indigenous virus yields from the bulk of the anaerobic digestion sludge and influent (solid) were obtained by utilizing 10 mM sodium pyrophosphate as eluant solution with vortex and 1 min of sonication. The use of 1× phosphate buffered saline as eluant with vortex and 1 min of sonication yields highest indigenous virus from activated sludge. The efficiency of extracting indigenous viruses by sodium pyrophosphate-ultrasound treatment was about 62% of the extractable virus particles from activated sludge and 87% for anaerobic digestion sludge, respectively. Samples treated with DNase had decreased, but not significant, virus counts, suggesting a minor effect of extracellular DNA on virus count. Following the optimized procedure, we investigated the abundance and diversity of virus particles in the wastewater stream of a municipal treatment plant. The concentrations of virus particles ranged from 0.28 × 109 ml−1 to 27.04 × 109 ml−1. Transmission electron microscopy (TEM) showed a high variety of virus morphotypes in sludge. Pulsed-field gel electrophoresis (PFGE) revealed a diverse and dynamic viral community in different stages of the system with genome sizes ranging from 33 kb to >350 kb with most of the viral DNA in the 30-80 kb and 200-350 kb size ranges. Collectively, our study suggested that indigenous viruses are abundant and dynamic in the municipal wastewater treatment system and may play an important role in functioning of the system.  相似文献   

14.
In the design of a wastewater treatment plant, engineers must estimate the future population that the plant will need to serve. When the population growth is uncertain, modular design can reduce up-front capital costs, operating costs and total expected present value costs. Models based on real option theory can provide insights to engineers/decision-makers that will not arise from standard net present value analysis. We consider a municipality faced with a plant expansion decision required to meet the demand of significant, uncertain growth. We present a model that optimises the size of the plant and its maximum modular size. The optimisation requires that multiple solutions be calculated at the decision time for the staged expansion. We utilise a moment matching technique to approximate the solution of the Asian-like option. The results show that as the uncertainty increases, a modular plant can save significant total costs for the municipality.  相似文献   

15.
We have long known that human occupants are a major source of microbes in the built environment, thus raising the question: How much can we learn about the occupants of a building by analyzing the microbial communities found in indoor air? We investigated bacterial and fungal diversity found in airborne dust collected onto heating, ventilation, and air‐conditioning (HVAC) air filters and settling plates from 91 rooms within a university dormitory. The sex of the room occupants had the most significant effect on the bacterial communities, while the room occupants had no significant effect on fungal communities. By examining the abundances of bacterial genera, we could predict the sex of room occupants with 79% accuracy, a finding that demonstrates the potential forensic applications of studying indoor air microbiology. We also identified which bacterial taxa were indicators of female and male rooms, and found that those taxa often identified as members of the vaginal microbiome were more common in female‐occupied rooms while taxa associated with human skin or the male urogenital microbiota were more common in male‐occupied rooms.  相似文献   

16.
Suh CW  Lee JW  Hong YS  Shin HS 《Water research》2009,43(1):137-147
We propose an evolutionary process model induction system that is based on the grammar-based genetic programming to automatically discover multivariate dynamic inference models that are able to predict fecal coliform bacteria removals using common process variables instead of directly measuring fecal coliform bacteria concentration in a full-scale municipal activated-sludge wastewater treatment plant. A sequential modeling paradigm is also proposed to derive multivariate dynamic models of fecal coliform removals in the evolutionary process model induction system. It is composed of two parts, the process estimator and the process predictor. The process estimator acts as an intelligent software sensor to achieve a good estimation of fecal coliform bacteria concentration in the influent. Then the process predictor yields sequential prediction of the effluent fecal coliform bacteria concentration based on the estimated fecal coliform bacteria concentration in the influent from the process estimator with other process variables. The results show that the evolutionary process model induction system with a sequential modeling paradigm has successfully evolved multivariate dynamic models of fecal coliform removals in the form of explicit mathematical formulas with high levels of accuracy and good generalization. The evolutionary process model induction system with sequential modeling paradigm proposed here provides a good alternative to develop cost-effective dynamic process models for a full-scale wastewater treatment plant and is readily applicable to a variety of other complex treatment processes.  相似文献   

17.
Seasonal change of virulent phage infected to two E. coli O157:H7 strains (O:157-phage) in the influent of a domestic wastewater treatment plant in the central part of Japan and fate of O:157-phage in the plant were monitored almost monthly from March 2001 to February 2002. Coliphage infected to nonpathogenic E. coli O157:H7 ATCC43888 (43888-phage) was detected for 1 year. On the other hand, phage infected to pathogenic E. coli O157:H7 EDL933 (EDL-phage) was detected intermittently. Concentration of EDL-phage was almost one-tenth of that of 43888-phage. The progressive decrease in phage concentration with the treatment steps was observed. No phage was detected in the supernatant from the secondary settling tank and effluent. PCR amplification of the Stx 2 gene that encodes Shiga toxin (Stx) was observed when O:157-phage concentration in the influent was high x10(3) PFU/ml order. Concentration and percentage of suspended O:157-phage decreased with the progress of the wastewater treatment. 933W phage, which encodes Stx 2 gene, was more fragile and sensitive to chlorination than T4 phage. However, addition of 0.02 mg/l chlorine, in conformance with the required concentration of the plant, did not affect the viability of T4 and 933 W phages. On the other hand, 1mg/l chlorine inactivated the 933 W phage significantly.  相似文献   

18.
Building predictive models for highly time varying and complex multivariable aspects of the wastewater treatment plant is important both for understanding the dynamics of this complex system, and in the development of optimal control support and management schemes.This paper presents a new approach, which is called genetic programming as a self-organising modelling tool, to model dynamic performance of municipal activated-sludge wastewater treatment plants. Genetic programming evolves several process models automatically based on methods of natural selection ('survival of the fittest'), that could predict the dynamics of MLSS and suspended solids in the effluent.The predictive accuracy of the genetic programming approach was compared with a nonlinear state-space model with neural network and a well-known IAWQ ASM2. The genetic programming system evolved some models that were an improvement over the neural network and ASM2 and showed that the transparency of the model evolved may allow inferences about underlying processes to be made. This work demonstrates that dynamic nonlinear processes in the wastewater treatment plant may be successfully modelled through the use of evolutionary model induction algorithms in GP technique. Further, our results show that genetic programming can work as a cost-effective intelligent modelling tool, enabling us to create prototype process models quickly and inexpensively instead of an engineer developing the process model.  相似文献   

19.
Methylmercury (MeHg) and total mercury (THg) inputs to the Mississippi River from a large metropolitan wastewater treatment plant were measured to characterize the relative contribution of the treatment plant to in-stream loads of these contaminants. Concentrations of MeHg and THg were determined in filtered and unfiltered whole water samples collected weekly from the treatment plant effluent stream and from the river upstream of the plant discharge. Unfiltered MeHg concentrations in the plant effluent ranged from 0.034 to 0.062 ng L(-1) and were always less than those in the river (range: 0.083-0.227 ng L(-1)). The MeHg loading to the river from the treatment plant ranged from 0.026 to 0.051 g d(-1) and averaged 0.037 g d(-1) over the 13-week sampling period. The in-stream MeHg load in the river upstream varied widely depending on hydrologic conditions, ranging from 0.91 to 18.8 g d(-1) and averaging 4.79 g d(-1). The treatment plant discharge represented 1.6%, on average, of the in-stream MeHg load, ranging from 0.2 to 3.5% depending on flow conditions in the river. MeHg in treatment plant effluent was primarily in the filtered phase (mean: 57%, <0.2 microm), but in the river the filtered/unfiltered ratio (F/UF) was typically less than 30% except during a major precipitation runoff event, when F/UF increased to 78%. The MeHg/THg ratio in unfiltered treatment plant effluent varied little (range: 1.6-1.9%), suggesting that THg concentration can serve as a relatively accurate proxy for MeHg concentration in this effluent stream. Supplemental sampling of the treatment plant influent stream showed that removals of MeHg and THg across the treatment process averaged 97% and 99%, respectively. These results show the treatment plant to be effective in removing MeHg and THg from wastewater and in minimizing its impact on Hg levels in the receiving water.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号