We evaluated the COBAS AMPLICOR PCR system (Roche Diagnostics) for the routine detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. Diagnostic culture, considered as the reference method, was performed with BACTEC, L?wenstein-Jensen, Stonebrink, and Kirchner media. Occasionally MB-Redox, ESP, or MGIT medium was also used. A total of 643 respiratory and 506 nonrespiratory specimens collected from 807 patients were investigated. Of the 95 culture-positive specimens, 80 were COBAS AMPLICOR MTB positive, and of the 1,054 culture-negative specimens, 1,044 were COBAS AMPLICOR MTB negative. After resolving discrepancies by review of the medical history, the overall sensitivity, specificity, and positive and negative predictive values for the COBAS AMPLICOR MTB assay, respectively, were 83.5, 98.8, 86.7, and 98.6% compared to those of diagnostic culture. In smear-positive specimens, the sensitivity of the COBAS AMPLICOR MTB assay was 96%, versus 48% for smear-negative specimens. No significant differences in the test performance between respiratory and nonrespiratory specimens were observed. The overall inhibition rate was less than 2%, excluding stool specimens. The clear advantages of the COBAS AMPLICOR PCR system are standardized procedures and reagents for specimen processing as well as an internal control for reliable monitoring of PCR inhibitors. By simplifying the work flow through a completely automated amplification and amplicon detection procedure, the COBAS AMPLICOR PCR system proved itself as a very useful component for routine diagnostic procedures.  相似文献   

2.
To evaluate the reliability and feasibility of the automated Roche COBAS AMPLICOR PCR system for routine detection of hepatitis C virus (HCV) RNA, a total of 405 serum samples previously tested by an in-house nested PCR and manual Roche AMPLICOR microwell plate HCV test were examined. Complete concordance was found between the results with the HCV COBAS AMPLICOR system and the previously determined HCV RNA status. The automated HCV COBAS AMPLICOR system provides the clinical microbiology laboratory with a specific and sensitive PCR method for rapid and reliable detection of HCV RNA.  相似文献   

3.
Certain strains of Neisseria subflava and Neisseria cinerea are known to produce false-positive results with the AMPLICOR Neisseria gonorrhoeae PCR (Roche Diagnostic Systems, Branchburg, N.J.). The analytical sensitivity and analytical specificity of three PCR tests were assessed with 3 geographically diverse N. gonorrhoeae strains and 30 non-N. gonorrhoeae Neisseria spp. The sensitivities of the in-house nested cppB gene and the 16S rRNA PCR methods were greater than that of the AMPLICOR N. gonorrhoeae PCR with purified DNA from all 3 N. gonorrhoeae strains. Six of 14 clinical strains of N. subflava (1 from a vaginal swab, 5 from respiratory sites) produced false-positive AMPLICOR N. gonorrhoeae PCR results and were negative by the two other PCR methods. When applied to 207 clinical specimens selected from a population with a high prevalence ( approximately 9%) of infection, the results for 15 of 96 (15.6%) AMPLICOR-positive specimens and 14 of 17 (82.3%) AMPLICOR-equivocal specimens were not confirmed by the more sensitive nested cppB PCR method. Only 2 of 94 (2.1%) of AMPLICOR N. gonorrhoeae PCR-negative specimens from the same population tested positive by the nested cppB method. These results suggest that for this population the AMPLICOR N. gonorrhoeae PCR test is suitable as a screening test only and all positive results should be confirmed by a PCR method that is more specific and at least as sensitive. This study also illustrates that caution should be used when introducing commercially available nucleic acid amplification-based diagnostic tests into the regimens of tests used for populations not previously tested with these products.  相似文献   

4.
We evaluated the performance of an automatic polymerase chain reaction (PCR) detection system for identification of Mycobacterium tuberculosis in respiratory specimens. Six hundred and two respiratory specimens, including 557 sputa and 45 bronchial washing samples, were analyzed using the COBAS AMPLICOR Mycobacterium tuberculosis (MTB) test. The results were compared with those obtained from acid-fast microscopy, conventional culture, and clinical history. In cases of discrepancy between the results of the COBAS AMPLICOR MTB test and culture, the medical history of the patient was reviewed, the COBAS AMPLICOR MTB test was repeated, and the gene encoding M. tuberculosis superoxide dismutase was screened using PCR (SOD-PCR). Fourteen samples were excluded because the internal control test result was negative. Of 57 specimens that were culture positive for Mycobacterium species, 40 appeared to have growth of M. tuberculosis and 21 were smear positive for acid-fast bacteria. The sensitivity, specificity, and positive and negative predictive values for the COBAS AMPLICOR MTB test evaluated at our laboratory were 85.0% (34/40), 99.3% (544/548), 89.5% (34/38), and 98.9% (544/550), respectively. Three specimens that were culture positive for M. tuberculosis but negative by COBAS AMPLICOR MTB test were positive when rechecked by both COBAS AMPLICOR MTB test and SOD-PCR. Among the four specimens with positive reactions on both COBAS AMPLICOR MTB test and SOD-PCR that were culture negative, two were from patients who had been receiving antituberculosis treatment, one was from a patient who had been treated for tuberculosis for 1 year, and the other was from a patient who died of sepsis with adult respiratory distress syndrome. In more than 70% of smear-negative and culture-positive specimens and 86.4% of smear-positive specimens, M. tuberculosis was identified by the COBAS AMPLICOR MTB test within 10 hours after receipt of the specimens. Our data show that the COBAS AMPLICOR MTB test provides rapid and accurate detection of M. tuberculosis in respiratory specimens.  相似文献   

5.
Eight laboratory assays, viz., the pp65 direct antigenemia test, a quantitative cytomegalovirus (CMV)-specific immunoglobulin G (IgG) assay (Biomerieux VIDAS), a CMV-specific IgM assay (Biomerieux VIDAS), the Hybrid Capture system (Murex), an in-house PCR with plasma (P-PCR) and leukocytes (L-PCR), and a commercial PCR (Roche AMPLICOR) with plasma (P-AMP) and leukocytes (L-AMP), were compared for their abilities to predict CMV disease before the onset of illness in a prospective study of 37 renal transplant recipients. By using an expanded criterion for active infection (two or more of the markers positive) and a clinical definition of disease, 22 (59%) patients were identified as having active CMV infection and 13 (35%) were identified as having CMV disease. Of the 13 CMV-seronegative recipients who received seropositive kidneys (R- group), 8 had active infection and disease. All assays were 100% specific and 100% predictive of CMV disease in the R- group. The leukocyte PCRs (L-PCR and L-AMP) were the most sensitive assays, had positive results an average of between 8 and 13 days before the onset of illness, and were the assays of choice. The performance of the assays was less satisfactory for the 24 patients who were CMV seropositive before transplantation (R+ group). A negative result was more useful for this group. Overall, P-AMP had the best results, and it could be the assay of choice for monitoring R+ patients. The non-PCR-based methods generally had high specificities but often gave late positive results and were not sensitive enough for use as prediction tools for either group of patients.  相似文献   

6.
We evaluated the AMPLICOR cytomegalovirus (CMV) PCR kit for the diagnosis of neurologic CMV infections on 43 positive and 112 negative archived cerebrospinal fluid specimens originally tested by an in-house PCR method. The AMPLICOR kit showed sensitivity and specificity of 95 and 100%, respectively, versus the home-grown assay, indicating its utility in this clinical setting.  相似文献   

7.
The use of the COBAS AMPLICOR System (Roche Molecular Diagnostics, Basel, Switzerland), the only automated system for PCR testing, was evaluated for a rapid identification of mycobacteria with positive BACTEC 12B cultures. Two hundred ninety-six specimens with a growth index of >/=30 were analyzed for the presence of Mycobacterium tuberculosis complex, Mycobacterium avium, and Mycobacterium intracellulare. Compared to traditional methods and provided that samples with PCR inhibition are retested at a 1:10 dilution, the sensitivity and specificity of the COBAS AMPLICOR System with BACTEC 12B cultures were 100 and 98%, respectively. The COBAS AMPLICOR method is rapid and reliable for identifying the most common mycobacteria in cultures.  相似文献   

8.
Eight commercial kits and an in-house ELISA for detection of IgG antibodies against Helicobacter pylori were evaluated for their use in diagnosis of H. pylori infection and in epidemiological research: Helico-GTM (Porton-Cambridge), G. A. P. test (Bio-Rad), H. pylori antibodies ELISA (Biometra), Anti-H. pylori IgG EIA (Roche), 2nd generation H. pylori EIA (Roche), Anti-H. pylori MTP-assay (Roche), Pylori stat test kit (Whittaker), Pyloriset latex agglutination kit (Orion), and the in-house ELISA based on heat-stable antigens. Fifty-four patients with dyspepsia (31 H. pylori positive by culture or microscopy) and 68 asymptomatic persons were tested. Sensitivities for the eight kits were 71%, 77%, 90%, 84%, 87%, 94%, 90%, 87%, and 87%, specificities were 74%, 65%, 74%, 74%, 83%, 83%, 70%, 65%, and 65%, respectively. For epidemiological use the estimated seroprevalence varied within approximately 15% in all age groups. Sensitivities and specificities obtained in different studies reveal as great differences in the results with the same kit as between results obtained with different kits in the same study. Kits with the highest sensitivities tend to be the same in all studies. It is therefore more important to test a kit in the population to which it is to be applied than to choose a specific kit.  相似文献   

9.
Three kits (Roche AMPLICOR human immunodeficiency virus type 1 [HIV-1] Monitor, Chiron enhanced-sensitivity bDNA, and Organon Teknika NASBA HIV-1 QT) and two in-house assays (from National Genetics Institute and Baylor College of Medicine) were compared with a blinded panel. The results were evaluated as to intra-assay sensitivity, precision, and ability to detect differences in a dilution series.  相似文献   

10.
The Roche Amplicor Mycobacterium tuberculosis PCR test was compared with mycobacterial culture for direct detection of M. tuberculosis in extrapulmonary specimens. From January 1995 to October 1996, 124 clinical specimens from 112 patients were assessed, including 47 body fluids, 61 tissue specimens and 16 abscesses. The sensitivity and specificity of Amplicor PCR compared to culture were 63.6% and 93.1% respectively. Analysis of 7 PCR-positive, culture-negative specimens confirmed that all were from patients with recently diagnosed tuberculosis under treatment. Eight specimens were PCR negative-culture positive, including a pleural fluid containing inhibitory substances. On acid-fast bacilli (AFB) smear-negative specimens, sensitivity and specificity were 53 and 100% respectively. The best results for Amplicor PCR were obtained with abscesses and biopsies. It is concluded that this test, highly specific for the diagnosis of tuberculosis, is at least as sensitive on extrapulmonary specimens as on smear-negative respiratory specimens.  相似文献   

11.
Chlamydia trachomatis infections are the most prevalent sexually transmitted diseases (STDs) in the United States. In acute-care settings such as clinics and emergency rooms, a desirable chlamydia screening assay should exhibit good sensitivity and good specificity and should provide test results while the patient is still present. The Biostar Chlamydia OIA (Biostar, Inc., Boulder, Colo.) is an optical immunoassay (OIA) that provides test results in less than 30 min and that uses a test format that allows office-based testing. This assay is performed entirely at room temperature without the need for rotators or other specialized equipment. The goal of this study was to compare the performance of the Biostar Chlamydia OIA for the detection of C. trachomatis with the performance of cell culture, direct fluorescent-antibody (DFA) assay (Syva MicroTrak; Syva Co., Palo Alto, Calif.), and PCR (Roche Amplicor Chlamydia trachomatis; Roche, Branchburg, N.J.) for the detection of C. trachomatis infections in women attending an urban STD clinic. For calculations of relative test performance (sensitivity, specificity, and positive and negative predictive values), patient specimens that yielded positive results by two or more of the four assays (cell culture, DFA assay, PCR, and OIA) were classified as "true infections." By these criteria, 42 of 306 total specimens were classified as positive for C. trachomatis (positive prevalence, 13.7%), 11 (3.6%; 10 by PCR and 1 by DFA assay) were positive by a single assay, and 253 (82.7%) were negative by all four tests. All culture-positive specimens were also positive by at least one other assay. Among the culture-negative specimens, 14(5%) specimens were positive by two of the three non-culture-based assays used. By using the criterion that positivity by at least two of the tests indicated a true infection,the relative sensitivities were as follows: culture and PCR, 92.9% each; Biostar Chlamydia OIA, 73.8%; and DFA assay, 59.5%.  相似文献   

12.
A new PCR kit (AMPLICOR CT/NG; Roche Diagnostic Systems, Inc., Branchburg, N.J.) was used as a screening tool for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine (FVU) specimens from 3,340 asymptomatic women attending European health care units for contraceptive advice or pregnancy termination. All samples were kept frozen (-20 degrees C) prior to testing. Chlamydia-positive samples were retested once by the plasmid-based PCR kit and also by a major outer membrane protein (MOMP) primer-based PCR. Discrepancies were resolved by using the direct immunofluorescence test (DIF) with the centrifuged sediment of the FVU specimens. Samples positive for N. gonorrhoeae were retested by chromosomal primer-based PCR and verified by a 16S RNA PCR. Of the samples tested, 1.8% were considered inhibitory by using the internal amplification control. Of 81 samples positive for C. trachomatis, 74 samples were positive by both plasmid- and MOMP-based PCRs, 6 samples were positive by plasmid-based PCR and DIF, and one sample was positive by both MOMP-based PCR and DIF. Nine samples (0.3%) were positive for N. gonorrhoeae by the chromosomal primer-based PCR; however, none of the results could be confirmed. The test offers the unique ability to identify inhibition of amplification with the optional internal control.  相似文献   

13.
The benefits shown by the recent introduction of PCR for the in vitro diagnosis of hepatitis C virus (HCV) infection has prompted the development of standardized, ready-to-use assays that can be implemented in routine clinical laboratories. We have evaluated the clinical performance of COBAS AMPLICOR HCV (COBAS), the first instrument system that allows the automation of HCV RNA amplification and detection, to determine its performance in the routine laboratory setting. More than 2,000 specimens collected at five centers were analyzed in parallel by the COBAS and the manual AMPLICOR HCV (AMPLICOR) tests, and the results were compared with the results for biochemical and serological markers of HCV. In this study the two PCR systems showed the same accuracy, with a concordance rate of 99.8%. As expected, the correlation between serology and PCR was not absolute because the presence of anti-HCV antibodies may be associated with a latent or past infection. On the other hand, if the presence of confirmed anti-HCV antibodies and elevated alanine aminotransferase levels are taken as the "gold standard," indicating an active, ongoing infection, the COBAS and AMPLICOR tests show high and comparable sensitivities (100%) and specificities (98%), with positive and negative predictive values of 100 and 97%, respectively. During the study no false-positive reactions were detected. The use of an internal control allowed the identification of inhibitory substances that prevented amplification for 0.3 and 0.4% of samples tested by the COBAS and AMPLICOR tests, respectively. Compared to the manual system, the COBAS system allowed a significant reduction of hands-on time and could improve the overall laboratory work flow. In conclusion, these results support the use of the COBAS and AMPLICOR tests for the molecular diagnosis of active HCV infections.  相似文献   

14.
Eighty clinical specimens of BACTEC 9240 blood culture vials, culture positive for staphylococci (38 Staphylococcus aureus and 42 coagulase negative staphylococci), were tested directly for the presence of clumping factor/protein A and free coagulase. Seven commercial slide agglutination kits were compared with a direct-tube coagulase (DTC) method. All tests were performed on blood culture pellets. Sensitivity, specificity, and negative and positive predictive values for the seven commercial kits were extremely variable, whereas a two-hour DTC test was highly predictive of S aureus. There was no significant difference between a two-, six- or 24-hour DTC test. Three (8%) S aureus isolates remained DTC negative even after 24 hours' incubation. Staphylococcal slide agglutination kits should not be used directly on blood culture broths. In contrast, a two-hour DTC test is a useful, rapid screening test for S aureus bacteraemia, provided isolates from DTC negative blood culture broths are re-tested using standard laboratory techniques.  相似文献   

15.
We evaluated the Amplicor C. trachomatis PCR assay (Roche Molecular Systems, N.J.) for the diagnosis of cervical infection in asymptomatic women attending a family planning clinic, aged between 18 and 25 years. Culture onto McCoy cells with fluorescent monoclonal staining was the reference system. Cervical specimens from 485 women were tested. The prevalence of C. trachomatis was 10.5% by culture and 11% by Amplicor. No specimen was positive by culture and negative by PCR. Three PCR-positive, culture-negative specimens were positive by MOMP-PCR and a second plasmid-based PCR. The resolved sensitivity of PCR and culture were 100% and 94.5%, respectively. Specificities for both were 100%, positive and negative predictive values for culture were 100% and 99.3%. Total test efficiency was 99.4%. The Amplicor C. trachomatis assay gave very clear results, quite above or below the cut-off value, and showed high sensitivity and specificity, improved ease of handling and represented a good alternative to culture for large scale diagnosis of asymptomatic C. trachomatis infection.  相似文献   

16.
We have developed the AMPLICOR CMV Test, which is rapid and sensitive for the detection of cytomegalovirus (CMV) in plasma and cerebrospinal fluid (CSF) specimens. The test incorporated an internal control in the reaction mixture to monitor the amplification efficiency and the presence of inhibitors. The AMPLICOR CMV Test was very specific in detecting 12 clinical CMV isolates and four laboratory CMV strains tested. Cross-reactivity with 26 non-CMV pathogens was not observed. The AMPLICOR CMV Test requires only 50 microl of specimen (plasma or CSF) for processing. The performance of the AMPLICOR CMV Test was compared to those of the CMV antigenemia assay and the conventional tube culture method. Among 112 plasma specimens from 43 human immunodeficiency virus-infected patients, CMV was detected in 20 (18%) of the specimens by the AMPLICOR CMV Test, 21 (19%) of the specimens by the CMV antigenemia assay, and 10 (9%) of the specimens by culture. In CSF specimens from AIDS patients, CMV was detected in 10 of 58 (17%) specimens tested by the AMPLICOR CMV Test, 5 of 28 (18%) specimens tested by the antigen assay, and none of the 25 specimens tested by culture. While the performance of the AMPLICOR CMV Test in this study was comparable to that of the CMV antigen assay, processing of specimens by the AMPLICOR CMV Test was much simpler than that by the antigen assay; in addition, the antigen assay requires greater than 10(5) leukocytes from blood or 1 ml of CSF to perform the assay. Our study suggested that the AMPLICOR CMV Test could provide a rapid and sensitive assay for the detection of CMV in plasma and CSF specimens.  相似文献   

17.
We report on a PCR-based assay we have developed for the detection of Mycobacterium tuberculosis in sputum samples. One hundred sputum specimens, which included 34 culture-positive and 66 culture-negative specimens, were evaluated with this system. Of the 34 culture-positive specimens, 31 were PCR positive, and 60 of the culture-negative specimens were PCR negative. An internal standard has been included in the assay system to monitor PCR inhibition and to confirm the reliability of the PCR assay.  相似文献   

18.
Microbiologically-inapparent chlamydial infection may contribute towards the immunopathogenesis of these diseases. Although morphologically and physiologically aberrant non-cultivable chlamydiae can be induced reversibly in cell culture, evidence for these forms in infections of animals and humans is indirect. A mouse model of salpingitis caused by the mouse pneumonitis biovar of Chlamydia trachomatis (MoPn) was used to determine the existence of non-cultivable organisms in vivo. Following intravaginal inoculation, mice yielded high chlamydial counts for 7-14 dyas, with a decline in culture-positivity by 21-28 days. A significant elevation of IFN gamma production in infected tissues was measured for 21 days and, from 28-70 days, all mice were culture-negative and developed characteristic hydrosalpinges. MoPn was detected by PCR in vaginal swabs of 80% and 69% respectively of culture-negative animals at 21 and 28 days. In a second study, 100%, 63% and 50% of culture-negative genital tissue homogenates were PCR-positive at 21, 28 and 42 days. Immunosuppression with either cyclophosphamide or hydrocortisone failed to regenerate cultivable chlamydiae. Tissues were disrupted by homogenization and inoculated intranasally to MF1 mice which are extremely susceptible to MoPn, but all culture-negative specimens were non-infectious. The significance of the PCR-positive culture-negative specimens requires further investigation, since these may represent a non-cultivable state in the deeper tissues of the mouse genital tract which may be beyond the reach of reactivating triggers.  相似文献   

19.
The AMPLICOR cytomegalovirus (CMV) test, a new qualitative assay for the detection of CMV DNA in plasma, was compared to conventional methods and quantitative PCR (Q-PCR) assays by using leukocytes and plasma from 179 blood samples from subjects with AIDS. For the diagnosis of CMV disease, cell-based assays such as a Q-PCR with polymorphonuclear leukocytes (Q-PCR-PMNL) and a pp65 antigenemia assay had the highest sensitivities but suffered from a lack of specificity. The best agreement between the results of the Q-PCR-PMNL assay and those of the AMPLICOR test was found when a threshold diagnostic value of 690 copies per 10(5) cells was selected for the Q-PCR-PMNL assay. In that context, the AMPLICOR CMV test had a sensitivity of 96.4% and a specificity of 95.3% when results were compared to results of the cell-based PCR assay. This threshold was close to the one described as associated with the best sensitivity and specificity for the diagnosis of CMV disease in a recently published study (4). Blood samples that tested positive by the Q-PCR-PMNL assay but negative by the AMPLICOR CMV test were associated with viral loads (mean, 785 copies, median, 96 copies per 10(5) leukocytes) lower than the viral loads of blood samples that tested positive by both assays (mean, 21,452 copies; median, 9,784 copies per 10(5) leukocytes) (P = 0.003). The AMPLICOR CMV test gave positive results at least 48 days before the development of symptomatic CMV disease in a longitudinal analysis of a limited subset of patients (n = 6) from whom sequential specimens were available for testing. In conclusion, the AMPLICOR CMV test is a very convenient assay combining rapidity, simplicity, and the possibility of batch testing. A positive result by this test seems particularly important since this implies, in most instances, the presence or the imminence of CMV disease, although a negative test result does not rule out disease.  相似文献   

20.
In the present study we comparatively evaluated the first- and second-generation Digene Hybrid Capture assays for detection of human papillomaviruses (HPV) associated with high or intermediate risk for cervical cancer in cervical specimens. Concordant results were obtained with 468 of 483 (96.8%) specimens. All 15 specimens which gave repeatedly discordant results were positive by the second-generation test only, and 14 of them tested PCR positive. The enhanced sensitivity of the second-generation assay is mainly a result of the reformulation of hybridization reagents and, to a lesser extent, a result of the addition of new HPV probes.  相似文献   