首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
For the representation of wind farms in transient stability studies of electrical power systems, reduced models based on aggregating identical wind turbines are commonly used. In the case of a wind farm with different wind turbines coupled to the same grid connection point, it is usual to aggregate identical wind turbines operating in similar conditions into an equivalent one. However, in the existing literature, there are not any references to the aggregation of different wind turbines (same wind turbine technology but different rated power or components) into a single one. This paper presents a comparative study of four reduced models for aggregating different DFIG wind turbines, experiencing different incoming winds, into an equivalent model. The first of them is the classical clustering model, in which each equivalent model experiences an equivalent wind. The other reduced models have the same equivalent generation system but different equivalent mechanical systems. Thus, the second and third ones are compound models with a clustering aggregated mechanical system and individual simplified models, respectively, to approximate the individual mechanical power according to the incoming wind speeds. The fourth is a mixed model that uses an equivalent wind speed, which is applied to an equivalent mechanical system (equivalent rotor and drive train) in order to approximate the mechanical power of the aggregated wind turbines. The equivalent models are validated by means of comparison with the complete model of the wind farm when simulated under wind fluctuations and grid disturbances. Finally, recommendations with regard to the applicability of models are established. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
The aim of this study is to provide a simplified model of a variable‐speed wind turbine (VSWT) with the technology of a doubly fed induction generator (DFIG), which operates under faulty grid conditions. A simplified model is proposed, which consists of a set of electrical and mechanical equations that can be easily modeled as simplistic electrical circuits. It makes it an excellent tool to achieve fault ride‐through capability of grid‐connected VSWT with DFIGs. Both symmetrical and unsymmetrical grid faults, which cause symmetrical and unsymmetrical voltage sags, have been applied to the system in order to validate the model. The proposed simplified model has been compared with the traditional full‐order model under multiple sags (different durations and depths), and the results reveal that both models present similar accuracy. As the idea is to reduce the computational time required to simulate the machine behavior under faulty grid conditions, the proposed model becomes suitable for that purpose. The analytical study has been validated by simulations carried out with MATLAB .  相似文献   

3.
Dynamic models of wind farms with fixed speed wind turbines   总被引:1,自引:0,他引:1  
The increasing wind power penetration on power systems requires the development of adequate wind farms models for representing the dynamic behaviour of wind farms on power systems. The behaviour of a wind farm can be represented by a detailed model including the modelling of all wind turbines and the wind farm electrical network. But this detailed model presents a high order model if a wind farm with high number of wind turbines is modelled and therefore the simulation time is long. The development of equivalent wind farm models enables the model order and the computation time to be reduced when the impact of wind farms on power systems is studied. In this paper, equivalent models of wind farms with fixed speed wind turbines are proposed by aggregating wind turbines into an equivalent wind turbine that operates on an equivalent wind farm electrical network. Two equivalent wind turbines have been developed: one for aggregated wind turbines with similar winds, and another for aggregated wind turbines under any incoming wind, even with different incoming winds.The proposed equivalent models provide high accuracy for representing the dynamic response of wind farm on power system simulations with an important reduction of model order and simulation time compare to that of the complete wind farm modelled by the detailed model.  相似文献   

4.
Inertia provision for frequency control is among the ancillary services that different national grid codes will likely require to be provided by future wind turbines. The aim of this paper is analysing how the inertia response support from a variable speed wind turbine (VSWT) to the primary frequency control of a power system can be enhanced. Unlike fixed speed wind turbines, VSWTs do not inherently contribute to system inertia, as they are decoupled from the power system through electronic converters. Emphasis in this paper is on how to emulate VSWTs inertia using control of the power electronic converter and on its impact on the primary frequency response of a power system. An additional control for the power electronics is implemented to give VSWTs a virtual inertia, referring to the kinetic energy stored in the rotating masses, which can be released initially to support the system's inertia. A simple Matlab/Simulink model and control of a VSWT and of a generic power system are developed to analyse the primary frequency response following different generation losses in a system comprising VSWTs provided with virtual inertia. The possibility of substituting a 50% share of conventional power with wind is also assessed and investigated. The intrinsic problems related to the implementation of virtual inertia are illustrated, addressing their origin in the action of pitch and power control. A solution is proposed, which aims at obtaining the same response as for the system with only conventional generation. The range of wind speeds near the power limitation zone seems to be the most critical from a primary response point of view. The theoretical reasons behind this are elucidated in the paper. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
H.H. Song  Y.B. Qu 《风能》2013,16(5):645-659
A novel nonlinear energy‐based excitation controlling strategy for variable‐speed doubly‐fed induction wind generator (DFIWG) is proposed in this paper. From the consideration of physical nature and energy flow of the DFIWG, the mechanical subsystem and the electromagnetical subsystem of the DFIWG first have their port‐controlled Hamiltonian (PCH) realization. Then taking advantage of the feedback interconnection between the subsystems, the entire PCH model of the DFIWG is established. On the basis of this model, the excitation control for the generator speed adjustment is achieved by energy shaping design with the purpose of optimum wind energy capture. Finally, simulation results via MATLAB/Simulink (MathWorks, Natick, MA, USA) confirm the effectiveness of the proposed approach for wind speeds in different operating stages. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
This paper presents a new algorithm based on the combination of fuzzy logic control with M5 decision tree algorithm for doubly fed induction generator active and reactive power control. The M5 model tree is a machine learning algorithm that uses the extracted dataset from fuzzy logic for the aim of control performance enhancement. Because the fuzzy logic provides high design and implementation complexity, the new control approach is proposed to reduce its complexity and to achieve fast dynamic control by translating the fuzzy logic algorithm into simple if‐then instructions using M5 model tree. The obtained model shows good agreement with fuzzy logic in rotor side control. The effectiveness of the proposed control approach is investigated through Matlab/Simulink software. Furthermore, a cosimulated through processor in the loop testing is performed as an experimental verification using a low‐cost STM32F407 discovery board.  相似文献   

7.
Xiangyu Zhang  Yi Wang  Yuan Fu  Lie Xu 《风能》2016,19(2):313-328
This paper investigates virtual inertia control of doubly fed induction generator (DFIG)‐based wind turbines to provide dynamic frequency support in the event of sudden power change. The relationships among DFIGs' virtual inertia, rotor speed and network frequency variation are analysed, and a novel virtual inertia control strategy is proposed. The proposed control strategy shifts the maximum power point tracking (MPPT) curve to the virtual inertia control curves according to the frequency deviation so as to release the ‘hidden’ kinetic energy and provide dynamic frequency support to the grid. The calculation of the virtual inertia and its control curves are also presented. Compared with a PD regulator‐based inertial controller, the proposed virtual inertia control scheme not only provides fast inertial response in the event of sudden power change but also achieves a smoother recovery to the MPPT operation. A four‐machine system with 30% of wind penetration is simulated to validate the proposed control strategy. Simulation results show that DFIG‐based wind farms can provide rapid response to the frequency deviation using the proposed control strategy. Therefore, the dynamic frequency response of the power grid with high wind power penetration can be significantly improved. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

8.
Modern wind turbines are predominantly variable speed wind turbines with power electronic interface. Emphasis in this paper is therefore on the modelling and control issues of these wind turbine concepts and especially on their impact on the power system. The models and control are developed and implemented in the power system simulation tool DIgSILENT. Important issues like the fault ride‐through and grid support capabilities of these wind turbine concepts are addressed. The paper reveals that advanced control of variable speed wind turbines can improve power system stability. Finally, it will be shown in the paper that wind parks consisting of variable speed wind turbines can help nearby connected fixed speed wind turbines to ride‐through grid faults. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

9.
The objective of this paper is to propose a simple approach to solve the steady state of a wind turbine (WT) equipped with a doubly fed induction generator (DFIG), which can be used to initialize dynamic studies of the machine. The idea is to model the rotor‐side converter (RSC) as a constant current source connected to the rotor of the DFIG. The resulting equivalent circuit consists of a voltage source in series with a reactance, which makes it possible to obtain simple phasor expressions that can be used to obtain the Park components of the variables. The proposed method is compared with the traditional Newton–Raphson algorithm, showing that it is easier and faster to implement, as it makes use of the phasor expressions and it does not require an iterative process to obtain the final solution. Finally, the results of the proposed method are used to simulate a 2‐MW DFIG‐based WT under three‐phase faults, considering three different WT‐operating points. In these simulations, the idea of constant rotor current is extrapolated to the entire event. The simulated results show that both current at torque peaks are reduced. The analytical study and the simulations have been carried out in Matlab ?.  相似文献   

10.
潮流计算是风电场接入系统设计的重要环节之一。准确的潮流计算结果对于建立风电场稳态模型是十分必要的。文章提出了不同控制方式下的双馈机组风电场节点在潮流计算中的处理方法以及潮流计算的具体步骤,给出了节点间的转化方法。运用PSASP进行仿真验证,证实了所提方法的可行性。  相似文献   

11.
This article considers gain‐scheduling control of variable‐speed wind energy conversion systems (WECS) in the context of linear parameter‐varying (LPV) systems. The typical problems of the classic gain‐scheduling techniques, such as stability guarantees, undesirable transient responses in the controller commutations and arduous design procedures, can be avoided with this new formulation. A model of a variable‐speed WECS expressed in LPV form and an optimal LPV gain‐scheduling control strategy are presented. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
This paper will describe the possibilities of coordinated control and management for different wind farm concepts to guarantee that operational set points of active and reactive power, specified by the Spanish transmission system operator (TSO), are reached. This coordinated control has been designed and implemented by a hierarchical and robust control structured from a central control level to each wind farm control board and finally to an individual wind turbine level. This article will demonstrate that both technologies, fixed and variable speed based wind farms can contribute to power and voltage control. In particular, this paper will deal with the use of under-load tap changing transformers in the point of common coupling of the wind farm with the grid, and the reactive power compensation by means of convectional mechanical switched capacitors enhancing the integration of the fixed speed wind farms in the power system.  相似文献   

13.
Larger percentages of wind power penetration into the grid translate to more demanding requirements coming from grid codes; for example, voltage support at the point of connection has been introduced recently by several grid codes from around the world, thus making it important to analyse this control. Voltage control is actuated by reactive power injection, and for a wind power plant of doubly fed generator turbines, reactive power capability can be a challenge, which typically is overcome by installing reactive power compensators. The integration and the interaction between all these reactive power sources and the on‐load tap changer of the main substation transformer need to be analysed and taken into account in the control design. In this paper, a novel coordination and control strategy for capacitor banks and on‐load tap changer for a wind power plant is introduced. The capacitor banks are controlled in such way that the steady‐state usage of the converters for reactive power injection is driven below to a maximum desired value of 0.1 pu. Additionally, the control transients because of the capacitor bank switching are minimized by using a suitable control structure. The tap changer control is coordinated with the plant control to decrease the impact of the capacitors reactive power in the line drop calculation, thus reducing the amount of tap operations and improving the accuracy of the line drop voltage estimation. The coordination of the central controller with the plant components is analysed and tested through electromagnetic transient program simulations. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
Centralised power control of wind farm with doubly fed induction generators   总被引:3,自引:0,他引:3  
At the moment, the control ability of wind farms is a prime research concern for the grid integration of large wind farms, due to their required active role in the power system. This paper describes the on-going work of a research project, whose overall objective is to analyse and assess the possibilities for control of different wind farm concepts. The scope of this paper is the control of a wind farm made up exclusively of doubly fed induction generators. The paper addresses the design and implementation issues of such a controller and focuses on the ability of the wind farm control strategy to regulate the wind farm power production to the reference power ordered by the system operators. The presented wind farm control has a hierarchical structure with both a central control level and a local control level. The central wind farm control level controls the power production of the whole farm by sending out reference power signals to each individual wind turbine, while the local wind turbine control level ensures that the reference power signal send by the central control level is reached. The performance of the control strategy is assessed and discussed by means of simulations illustrated both at the wind farm level and at each individual wind turbine level.  相似文献   

15.
Xing Li  Yao Sun  Mei Su  Hui Wang 《风能》2014,17(2):317-336
This paper proposes a coordinated control scheme of a stand‐alone doubly fed induction generator (DFIG)‐based wind energy conversion system to improve the operation performance under unbalanced load conditions. To provide excellent voltage profile for load, a direct stator flux control scheme based on auto‐disturbance rejection control (ADRC) is applied, and less current sensors are required. Due to the virtues of ADRC, the controller has good disturbance rejection capability and is robust to parameter variation. In the case of unbalanced loads, the electromagnetic torque pulsations at double synchronous frequency will exist. To eliminate the undesired effect, the stator‐side converter (SSC) is used to provide the negative sequence current components for the unbalanced load. Usually, proportional integral controllers in a synchronous reference frame are used to control SSC. To simplify the algorithm, an improved proportional resonant (PR) control is proposed and used in the current loop without involving positive and negative sequence decomposition. The improved PR provides more degree of freedom which could be used to improve the performance. The effectiveness of the proposed control scheme has been validated by the simulation and experimental results. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
This paper presents a comparison of three variable‐speed wind turbine simulators used for a 2 MW wind turbine short‐term transient behaviour study during a symmetrical network disturbance. The simulator with doubly fed induction generator (DFIG) analytical model, the simulator with a finite element method (FEM) DFIG model and the wind turbine simulator with an analytical model of DFIG are compared. The comparison of the simulation results shows the influence of the different modelling approaches on the short‐term transient simulation accuracy. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

17.
This paper investigates the physical capability of double‐fed induction generator (DFIG) wind turbines for inertial support of frequency response. Frequency stability is modeled using the DFIG electromechanical and generator controller dynamics, and a destabilizing effect is demonstrated in low‐inertia systems. To improve response, a synchronous reference frame DFIG controller is proposed that acts by following low‐frequency grid dynamics and adds a fast acting proportional plus integral (PI)‐controlled frequency‐responsive component to existing qd current commands. The proposed controller is derived in a straightforward manner using only the DFIG dynamic equations and is designed using pole/zero placement techniques. Laboratory experiments using a micro‐scale DFIG wind turbine with hub‐emulating flywheel prove better capability for transient frequency regulation even under extreme load change. The result is a DFIG controller that balances the appearance of transients in electrical and mechanical systems. Value is achieved in providing immediate continuous inertial response to support load change. The proposed frequency response can improve the use of existing physical inertia from wind turbines.  相似文献   

18.
Vladislav Akhmatov 《风能》2006,9(4):313-326
A model for a variable speed wind turbine with a permanent magnet, multipole, synchronous generator is developed and implemented in the simulation tool PSS/E as a user‐written model. The model contains representations of the permanent magnet generator, the frequency converter system with control, the aerodynamic rotor and a lumped mass representation of the shaft system. This model complexity is needed for investigations of the short‐term voltage stability and ride‐through capability of such wind turbines. Ride‐through capability is a major issue and, for the given concept, can be achieved by applying blocking and restart sequences to the frequency converter at the voltage drop in the power grid. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

19.
介绍了一种在PSCAD/EMTDC环境中建立双馈风电机组模型以用于电磁暂态分析的方法。分析了风力机风速与输出转矩的关系,建立了机侧换流器的定子磁链定向矢量控制模型、网侧换流器的电网电压定向矢量控制模型,并考虑了低电压穿越控制策略。最后在PSCAD/EMTDC环境中建立了双馈风电机组的模型,仿真验证了建模方法的有效性和正确性。仿真结果表明,在PSCAD/EMTDC环境中,双馈风机建模方法能够准确地描述风电机组的电磁暂态特性。  相似文献   

20.
This article compares three reduced models with a detailed model of a doubly fed induction generator system for wind turbine applications. The comparisons are based on simulations only. The main idea is to provide reduced generator models which are appropriate to simulate normal wind turbine operation in aeroelastic wind turbine models, e.g. for control system design or structural design of the wind turbine. The electrical behaviour such as grid influence will therefore not be considered. The work presented in this article shows that with an ideal, undisturbed grid the dynamics of the doubly fed induction generator system is very well represented by the dynamics due to the generator inertia and the generator control system, whereas the electromagnetic characteristics of the generator can be represented by the steady state relations. The parameters for the proposed models are derived from parameters typically available from the generator data sheet and from the controller settings. Thus the models are simple to apply in any case where the generator data sheet is available. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏