首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This paper describes a method for spatial encoding in synthetic transmit aperture ultrasound imaging. This allows several ultrasonic sources to be active simultaneously. The method is based on transmitting pseudorandom sequences to spatially encode the transmitters. The data can be decoded after only one transmission using the knowledge of the transmitted code sequences as opposed to other spatial encoding techniques, such as Hadamard or Golay encoding. This makes the method less sensitive to motion, and data can be acquired using fewer transmissions. The aim of this paper is to analyze the underlying theory and to test the feasibility in a physical system. The method has been evaluated in simulations using Field II in which the point-spread functions were simulated for different depths for a 7 MHz linear array transducer. A signal-to-noise ratio (SNR) simulation also was included in the study in which an improvement in SNR of approximately 1.5 dB was attained compared to the standard synthetic transmit aperture (STA) firing scheme. Considering the amount of energy transmitted, this value is low. A plausible explanation is given that is verified in simulation. The method also was tested in an experimental ultrasound scanner and compared to a synthetic transmit aperture ultrasound imaging scheme using a sinusoidal excitation. The performance of the proposed method was comparable to the reference with respect to axial and lateral resolution, but it displayed poorer contrast with sidelobe levels at approximately - 40 dB compared to the mainlobe.  相似文献   

2.
A frequency-domain method for implementing the synthetic aperture focusing technique is developed and demonstrated using computer simulation. As presented, the method is well suited to reconstructing ultrasonic reflectivity over a volumetric region of space using measurements made over an adjacent two-dimensional aperture. Extensive use is made of both one- and two-dimensional Fourier transformations to perform the temporal and spatial correlation required by the technique, making the method well suited to general-purpose computing hardware. Results are presented demonstrating both the lateral and axial resolution achieved by the method. The effect of limiting the reconstruction bandwidth is also demonstrated.  相似文献   

3.
A new method for filtering the coherence map issued from synthetic aperture radar (SAR) interferometric data is presented. For each pixel of the interferogram, an adaptive neighborhood is determined by a region-growing technique driven by the information provided by the amplitude images. Then pixels in the derived adaptive neighborhood are complex averaged to yield the filtered value of the coherence, after a phase-compensation step is performed. An extension of the algorithm is proposed for polarimetric interferometric SAR images. The proposed method has been applied to both European Remote Sensing (ERS) satellite SAR images and airborne high-resolution polarimetric interferometric SAR images. Both subjective and objective performance analysis, including coherence edge detection, shows that the proposed method provides better results than the standard phase-compensated fixed multilook filter and the Lee adaptive coherence filter.  相似文献   

4.
The oscillating profile naturally present in ultrasound images has been shown to be extremely valuable in different applications, particularly in motion estimation. Recent studies have shown that it is possible to produce images with transverse oscillations (TOs) based on a specific type of beamforming. However, there is still a great difference between the nature of the lateral oscillations produced with current methods and the axial profile of ultrasound images. In this study, we propose to combine synthetic aperture imaging (synthetic transmit aperture, STA) using a specific beamformer in both transmit mode and receive mode combined with a heterodyning demodulation method to produce lateral radiofrequency signals (LRFs). The aim was to produce lateral signals as close as possible to conventional axial signals, which would make it possible to estimate lateral displacements with the same accuracy as in the axial direction. The feasibility of this approach was validated in simulation and experimentally on an ultrasound research platform, the Ultrasonix RP system. We show that the combination of STA and the heterodyning demodulation can divide the wavelength of the LRF signals by 4 and divide the width of the lateral envelope of the point spread function (PSF) by 2 compared with the previous approaches using beamforming in receive mode only. Finally, we also illustrate the potential of our beamforming for motion estimation compared with previous TO methods.  相似文献   

5.
A two-dimensional (2-D) array of 256 X 256 = 65,536 elements, with total area 4 X 4 = 16 cm2, serves as a flexible platform for developing acquisition schemes for 3-D rectilinear ultrasound imaging at 10 MHz using synthetic aperture techniques. This innovative system combines a simplified interconnect scheme and synthetic aperture techniques with a 2-D array for 3-D imaging. A row-column addressing scheme is used to access different elements for different transmit events. This addressing scheme is achieved through a simple interconnect, consisting of one top, one bottom single-layer, flex circuits that, compared to multilayer flex circuits, are simpler to design, cheaper to manufacture, and thinner so their effect on the acoustic response is minimized. We present three designs that prioritize different design objectives: volume acquisiton time, resolution, and sensitivity, while maintaining acceptable figures for the other design objectives. For example, one design overlooks time-acquisition requirements, assumes good noise conditions, and optimizes for resolution, achieving -6 dB and -20 dB beamwidths of less than 0.2 and 0.5 mm, respectively, for an F/2 aperture. Another design can acquire an entire volume in 256 transmit events, with -6 dB and -20 dB beamwidths in the order of 0.4 and 0.8 mm, respectively.  相似文献   

6.
A comprehensive theoretical performance comparison of the wideband maximum-likelihood (WMLE) and cross-correlation strategies, previously proposed and evaluated for the estimation of blood velocity using ultrasound is presented. It is based on evaluation of the bias, local and global accuracy, and signal-to-noise ratio (SNR) performance. The results show that the intervening medium does not bias either wideband estimation, due to the effect of tracking the scattering target. The presence of intervening tissue actually improves the global accuracy of both wideband estimators, without a significant change in the local accuracy of either wideband estimator. After the transmission of P pulses, a comparison of the performance of the two strategies shows that the cross-correlation estimator requires P(2 ) correlations to achieve performance similar to that of the WMLE with P operations. In addition, the WMLE can increase the effective SNR in comparison with cross correlation.  相似文献   

7.
In the past we proposed a multidimensional speckle noise model to which we now include systematic phase variation effects. This extension makes it possible to define what is believed to be a novel coherence model able to identify the different sources of bias when coherence is estimated on multidimensional synthetic radar aperture (SAR) data. On the one hand, low coherence biases are basically due to the complex additive speckle noise component of the Hermitian product of two SAR images. On the other hand, the availability of the coherence model permits us to quantify the bias due to topography when multilook filtering is considered, permitting us to establish the conditions upon which information may be estimated independently of topography. Based on the coherence model, two coherence estimation approaches, aiming to reduce the different biases, are proposed. Results with simulated and experimental polarimetric and interferometric SAR data illustrate and validate both, the coherence model and the coherence estimation algorithms.  相似文献   

8.
Conventional (Doppler-based) blood flow velocity measurement methods using ultrasound are capable of resolving the axial component (i.e., that aligned with the ultrasound propagation direction) of the blood flow velocity vector. However, these methods are incapable of detecting blood flow in the direction normal to the ultrasound beam. In addition, these methods require repeated pulse-echo interrogation at the same spatial location. A new method has been introduced which estimates the lateral component of blood flow within a single image frame using the observation that the speckle pattern corresponding to blood reflectors (typically red blood cells) stretches (i.e., is smeared) if the blood is moving in the same direction as the electronically-controlled transducer line selection in a 2-D image. The situation is analogous to the observed distortion of a subject photographed with a moving camera. The results of previous research showed a linear relationship between the stretch factor (increase in lateral speckle size) and blood flow velocity. However, errors exist in the estimation when used to measure blood flow velocity. In this paper, the relationship between speckle size and blood flow velocity is investigated further with both simulated flow data and measurements from a blood flow phantom. It can be seen that: 1) when the blood flow velocity is much greater than the scan velocity (spatial rate of A-line acquisition), the velocity will be significantly underestimated because of speckle decorrelation caused by quick blood movement out of the ultrasound beam; 2) modeled flow gradients increase the average estimation error from a range between 1.4% and 4.4%, to a range between 4.4% and 6.8%; and 3) estimation performance in a blood flow phantom with both flow gradients and random motion of scatterers increases the average estimation error to between 6.1% and 7.8%. Initial attempts at a multiple-scan strategy for estimating flow by a least-squares model suggest the possibility of increased accuracy using multiple scan velocities.  相似文献   

9.
A synthetic aperture is an effective approach to enhancement of the resolution of telescopes. In this paper, a new method to improve the resolution by using a pair of gratings is proposed. It allows collection of parts of the light diffracted from the object which could not previously reach the imaging device. This method improves the resolution and light energy utilization ratio of telescopes without introducing new chromatic aberration. An experiment for resolution testing was carried out and the feasibility and availability of the method were verified.  相似文献   

10.
The error characteristics of a single-transducer (one dimensional), dual-transducer (two-dimensional), and triple-transducer (three-dimensional) system for velocity estimation are examined. A velocity vector is completely characterized by the magnitude and the directional angles. For a single-transducer case, the velocity magnitude alone can be estimated. The variation in the directional angles for a single-transducer case cannot be accounted for in the estimation process, thus resulting in large errors. For a dual transducer, both the velocity magnitude and the angle on the x-y plane can be estimated. The use of an extra transducer provides added flexibility in the estimation process. Variation in one of the directional angles is accounted for in the estimation process, thus resulting in smaller error than the single-transducer case. For a triple-transducer case, if the normal angles between the three transducer axes are known, then the complete velocity vector with all the directional angles can be estimated.  相似文献   

11.
基于单基元几何交汇法的被动目标测距测速研究   总被引:1,自引:0,他引:1       下载免费PDF全文
从理论上分析和推导了单传感器测距测速的几何交汇模型,该模型结合二维栅格搜索策略对具有稳定线谱的匀速直线运动目标进行距离和速度的估计。为满足交汇模型的测频精度要求,介绍了对短样本信号进行测频的谱估计法、过零法和Hilbert方法。把多组对应一定特征频率、正横距离、目标速度和信噪比的目标通过信号代入交汇模型进行计算机仿真,相应得出一系列测量误差曲线,分析结果表明,对于一定参数的通过信号该模型可以较精确的估计出目标的正横距离及速度。  相似文献   

12.
A significant improvement in blood velocity estimation accuracy can be achieved by simultaneously processing both temporal and spatial information obtained from a sample volume. Use of the spatial information becomes especially important when the temporal resolution is limited. By using a two-dimensional sequence of spatially sampled Doppler signal "snapshots" an improved estimate of the Doppler correlation matrix can be formed. Processing Doppler data in this fashion addresses the range-velocity spread nature of the distributed red blood cell target, leading to a significant reduction in spectral speckle. Principal component spectral analysis of the "snapshot" correlation matrix is shown to lead to a new and robust Doppler mode frequency estimator. By processing only the dominant subspace of the Doppler correlation matrix, the Cramer-Rao bounds on the estimation error of target velocity is significantly reduced in comparison to traditional narrowband blood velocity estimation methods and achieves almost the same local accuracy as a wideband estimator. A time-domain solution is given for the velocity estimate using the root-MUSIC algorithm, which makes the new estimator attractive for real-time implementation.  相似文献   

13.
Zhang  J. Mu  X. Chen  E. Yang  S. 《Communications, IET》2009,3(7):1136-1143
A decision-directed (DD) channel estimation based on iterative linear minimum mean square error (LMMSE) is proposed for orthogonal frequency division multiplexing systems. Existing DD channel estimation is well known to have the problem of error propagation because of symbol-by-symbol detection. The proposed algorithm can estimate the correction term of current channel state information (CSI) according to the error vector of previous CSI by applying the orthogonality principle, and corrects the current CSI with this correction term. Analysis and simulation results have shown that this method has no error propagation problem. The performance of the proposed algorithm is much better than the conventional DD channel estimation, and close to the optimal LMMSE estimator, but with much less computational complexity compared with the optimal LMMSE estimator.  相似文献   

14.
Phase errors in synthetic aperture sonar (SAS) imaging must be reduced to less than one eighth of a wavelength so as to avoid image destruction. Most of the phase errors occur as a result of platform motion errors, for example, sway yaw and surge that are the most important error sources. The phase error of a wide band synthetic aperture sonar is modeled and solutions to sway yaw and surge motion estimation based on the raw sonar echo data with a Displaced Phase Center Antenna (DPCA) method are proposed and their implementations are detailed in this paper. It is shown that the sway estimates can be obtained from the correlation lag and phase difference between the returns at coincident phase centers. An estimate of yaw is also possible if such a technique is applied to more than one overlapping phase center positions. Surge estimates can be obtained by identifying pairs of phase centers with a maximum correlation coefficient. The method works only if the platform velocity is low enough such that a number of phase centers from adjacent pings overlap.  相似文献   

15.
In this paper a method for designing waveforms for temporal encoding in medical ultrasound imaging is described. The method is based on least squares optimization and is used to design nonlinear frequency modulated signals for synthetic transmit aperture imaging. By using the proposed design method, the amplitude spectrum of the transmitted waveform can be optimized, such that most of the energy is transmitted where the transducer has large amplification. To test the design method, a waveform was designed for a BK8804 linear array transducer. The resulting nonlinear frequency modulated waveform was compared to a linear frequency modulated signal with amplitude tapering, previously used in clinical studies for synthetic transmit aperture imaging. The latter had a relatively flat spectrum which implied that the waveform tried to excite all frequencies including ones with low amplification. The proposed waveform, on the other hand, was designed so that only frequencies where the transducer had a large amplification were excited. Hereby, unnecessary heating of the transducer could be avoided and the signal-to-noise ratio could be increased. The experimental ultrasound scanner RASMUS was used to evaluate the method experimentally. Due to the careful waveform design optimized for the transducer at hand, a theoretic gain in signal-to-noise ratio of 4.9 dB compared to the reference excitation was found, even though the energy of the nonlinear frequency modulated signal was 71% of the energy of the reference signal. This was supported by a signal-to-noise ratio measurement and comparison in penetration depth, where an increase of 1 cm was found in favor for the proposed waveform. Axial and lateral resolutions at full-width half-maximum were compared in a water phantom at depths of 42, 62, 82, and 102 mm. The axial resolutions of the nonlinear frequency modulated signal were 0.62, 0.69, 0.60, and 0.60 mm, respectively. The corresponding axial resolutions for the reference waveform were 0.58, 0.65, 0.62, and 0.60 mm, respectively. The compression properties of the matched filter (mismatched filter for the linear frequency modulated signal) were tested for both waveforms in simulation with respect to the Doppler frequency shift occurring when probing moving objects. It was concluded that the Doppler effect of moving targets does not significantly degrade the filtered output. Finally, in vivo measurements are shown for both methods, wherein the common carotid artery on a 27-year-old healthy male was scanned.  相似文献   

16.
李晟  王博文  管海涛  梁坤瑶  胡岩  邹燕  张许  陈钱  左超 《光电工程》2023,50(10):230090-1-230090-27

传统光学成像实质上是目标场景的光强信号在空间维度上的直接均匀采样记录与再现的过程。因此,其成像分辨率与信息量不可避免地受到光学衍射极限、成像系统空间带宽积等若干物理条件制约。如何突破这些物理制约,获得更高分辨率、更宽广的图像信息,一直是该领域的永恒课题。计算光学成像通过前端光学调控与后端信号处理相结合,为突破成像系统的衍射极限限制,实现超分辨成像提供了新思路。本文综述了基于计算光学合成孔径成像实现成像分辨率的提升以及空间带宽积拓展的相关研究工作,主要包括基于相干主动合成孔径成像与非相干被动合成孔径成像的基础理论及关键技术。本文进一步揭示了当前“非相干、无源被动、超衍射极限”成像的迫切需求及其现阶段存在的瓶颈问题,并展望了今后的研究方向以及解决这些问题可能的技术途径。

  相似文献   

17.
A useful nondestructive testing tool for civil engineering should immediately reveal defects inside concrete structures at the construction sites. To date, there are few effective methods to image defects inside concrete structures. In this paper, a new nondestructive testing method using elastic waves for imaging possible defects inside concrete is developed. This method integrates the point-source/point receiver scheme with the synthetic aperture focusing technique (SAFT) to increase functioning depth and enhance received signals. To improve image quality, received signals are processed by Hilbert-Huang transform (HHT) to get time-frequency curves for the SAFT process. Compared with conventional SAFT method processing with time-amplitude signals, this new method is capable of providing a better image of defects not only in the numerical simulation but also in the experimental result. The image can reveal the number of defects and their locations and front-end profiles. The results shown in this paper indicate that this new elastic-wave-based method exhibits high capability in imaging the defects of in situ concrete structures.  相似文献   

18.
For pt.I see ibid., vol.45, no.4, pp.939-54 (1998). The statistical performance of the new 2-D narrowband time-domain root-MUSIC blood velocity estimator described previously is evaluated using both simulated and flow phantom wideband (50% fractional bandwidth) ultrasonic data. Comparisons are made with the standard 1-D Kasai estimator and two other wideband strategies: the time domain correlator and the wideband point maximum likelihood estimator. A special case of the root-MUSIC, the "spatial" Kasai, is also considered. Simulation and flow phantom results indicate that the root-MUSIC blood velocity estimator displays a superior ability to reconstruct spatial blood velocity information under a wide range of operating conditions. The root-MUSIC mode velocity estimator can be extended to effectively remove the clutter component from the sample volume data. A bimodal velocity estimator is formed by processing the signal subspace spanned by the eigenvectors corresponding to the two largest eigenvalues of the Doppler correlation matrix. To test this scheme, in vivo common carotid flow complex Doppler data was obtained from a commercially available color flow imaging system. Velocity estimates were made using a reduced form of this data corresponding to higher frame rates. The extended root-MUSIC approach was found to produce superior results when compared to both 1- and 2-D Kasai-type estimators that used initialized clutter filters. The results obtained using simulated, flow phantom, and in vivo data suggest that increased sensitivity as well as effective clutter suppression can be achieved using the root-MUSIC technique, and this may be particularly important for wideband high frame rate imaging applications.  相似文献   

19.
Di J  Zhao J  Jiang H  Zhang P  Fan Q  Sun W 《Applied optics》2008,47(30):5654-5659
Theoretical analysis shows that, to improve the resolution and the range of the field of view of the reconstructed image in digital lensless Fourier transform holography, an effective solution is to increase the area and the pixel number of the recorded digital hologram. A new approach based on the synthetic aperture technique and use of linear CCD scanning is presented to obtain digital holographic images with high resolution and a wide field of view. By using a synthetic aperture technique and linear CCD scanning, we obtained digital lensless Fourier transform holograms with a large area of 3.5 cm x 3.5 cm (5000 x 5000 pixels). The numerical reconstruction of a 4 mm object at a distance of 14 cm by use of a Rayleigh-Sommerfeld integral shows that a theoretically minimum resolvable distance of 2.57 microm can be achieved at a wavelength of 632.8 nm. The experimental results are consistent with the theoretical analysis.  相似文献   

20.
Orthogonal frequency division multiplexing with code division multiplexing (OFDM-CDM) is attractive for the next generation high-speed wireless systems due to the fact that the performance of OFDM-CDM systems can be considerably improved by employing a joint detection scheme such as the maximum likelihood (ML) detector. However, the complexity of the ML detector increases rapidly as the number of orthogonal spreading codes and/or the number of bits per modulation symbol increase. In this study, the authors introduce a unified detection model and propose two hybrid detectors, which combine zero forcing (ZF) with successive interference cancellation (SIC) and sphere detection (SD) algorithms, respectively. After obtaining the initial solution from the front-end ZF receiver, the proposed back-end algorithms are adopted to extend the potential solution list and search for the final result. The objective is to utilise the combination of a simplified linear equaliser and a comprehensive detection scheme to achieve enhanced performance and offer alternatives to the more complex and channel-estimation-sensitive minimum mean squared error (MMSE) scheme. The results show that the proposed hybrid detectors are able to achieve superior performance compared to the MMSE scheme and provides a significant performance improvement compared to the conventional OFDM counterpart.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号