首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
For the cost per kilowatt hour to be decreased, the trend in offshore wind turbines is to increase the rotor diameter as much as possible. The increasing dimensions have led to a relative increase of the loads on the wind turbine structure; thus, it is necessary to react to disturbances in a more detailed way, e.g. each blade separately. The disturbances acting on an individual wind turbine blade are to a large extent deterministic; for instance, tower shadow, wind shear, yawed error and gravity are depending on the rotational speed and azimuth angle and will change slowly over time. This paper aims to contribute to the development of individually pitch‐controlled blades by proposing a lifted repetitive controller that can reject these periodic load disturbances for modern fixed‐speed wind turbines and modern variable‐speed wind turbines operating above‐rated. The performance of the repetitive control method is evaluated on the UPWIND 5 MW wind turbine model and compared with typical individual pitch control. Simulation results indicate that for relatively slow changing periodic wind disturbances, this lifted repetitive control method can significantly reduce the vibrations in the wind turbine structure with considerably less high‐frequent control action. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
An evolutionary computation approach for optimization of power factor and power output of wind turbines is discussed. Data-mining algorithms capture the relationships among the power output, power factor, and controllable and non-controllable variables of a 1.5 MW wind turbine. An evolutionary strategy algorithm solves the data-derived optimization model and determines optimal control settings. Computational experience has demonstrated opportunities to improve the power factor and the power output by optimizing set points of blade pitch angle and generator torque. It is shown that the pitch angle and the generator torque can be controlled to maximize the energy capture from the wind and enhance the quality of the power produced by the wind turbine with a DFIG generator. These improvements are in the presence of reactive power remedies used in modern wind turbines. The concepts proposed in this paper are illustrated with the data collected at an industrial wind farm.  相似文献   

3.
E. A. Bossanyi 《风能》2000,3(3):149-163
This article reviews the design of algorithms for wind turbine pitch control and also for generator torque control in the case of variable speed turbines. Some recent and possible future developments are discussed. Although pitch control is used primarily to limit power in high winds, it also has a significant effect on various loads. Particularly as turbines become larger, there is increasing interest in designing controllers to mitigate loads as far as possible. Torque control in variable speed turbines is used primarily to maximize energy capture below rated wind speed and to limit the torque above rated. Once again there are opportunities for designing these controllers so as to mitigate certain loads. In addition to improving the design of the control algorithms, it is also possible to use additional sensors to help the controller to achieve its objectives more effectively. The use of additional actuators in the form of individual pitch controllers for each blade is also discussed. It is important to be able to quantify the benefits of any new controller. Although computer simulations are useful, field trials are also vital. The variability of the real wind means that particular care is needed in the design of the trials. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

4.
Throughout Europe there is an increasing trend of connecting high penetrations of wind turbines to the transmission networks. This has resulted in transmission system operators revising their grid code documents for the connection of large wind farms. These specifications require large MW capacity wind farms to have the ability to assist in some of the power system control services currently carried out by conventional synchronous generation. These services include voltage and frequency control. It is now recognized that much of this new wind generation plant will use either fixed speed induction generator (FSIG)‐ or doubly fed induction generator (DFIG)‐based wind turbines. The addition of a control loop to synthesize inertia in the DFIG wind turbine using the power electronic control system has been described. The possibility of deloading wind turbines for frequency response using blade pitch angle control is discussed. A pitch control scheme to provide frequency response from FSIG and DFIG wind turbines is also described. A case study of an FSIG wind turbine with frequency response capabilities is investigated. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

5.
The successfully developed wind chiller in our CCT Lab. directly uses wind force to drive refrigeration system and hence reduces two times energy conversions between mechanical and electrical energies. The wind chiller needs high wind speed for its effective work due to the large working torque is required by the compressor. For the purpose of enlarging the applied wind field by the wind machine, this work aims to develop a dual system of wind chiller integrated with wind generator. The integrated wind generator can use the wind energy which cannot effectively drive the compressor. Therefore, the new developed dual system can apply larger range of the wind field and further increase the total working efficiency of the wind machine. A programmable logic controller (PLC) is applied in this wind forced dual system to select the wind chiller or the wind generator separately in terms of the rotational speed of the wind machine. In this work, the wind chiller is switched on while the accelerated rotational speed reaches 80 rpm and off while the decelerated rotational speed reaches 60 rpm. The integrated wind generator is switched on while the decelerated rotational speed reaches 60 rpm and off while the decelerated rotational speed reaches 40 rpm. The two apparatuses in the dual system always work separately. The results show that there is ca. 18.5% increment of effective working efficiency which is captured by the wind generator.  相似文献   

6.
In order to improve the torque performance of the propeller type wind turbine, and to increase the relative rotational speed of the generator, two-staged wind turbines were proposed. The experimental results of a wind tunnel test showed that self-starting characteristics of two-staged co-axial type were improved by attached front wind turbines for two bladed main wind turbine, and the relative rotational speed of counter-rotating type was increased.Then, a counter-rotating type trial machine was constructed and a wind tunnel test was also conducted. The test result demonstrated the technical possibility of conterrotating type wind powered generator.  相似文献   

7.
This paper describes a new wind turbine simulator for dynamic conditions. The authors have developed an experimental platform to simulate the static and dynamic characteristics of real wind energy conversion system. This system consists of a 3 kW dc motor, which drives a synchronous generator. The converter is a 3 kW single-phase half-controlled converter. MATLAB/Simulink real time control software interfaced to I/O board and a converter controlled dc motor are used instead of a real wind turbine. A MATLAB/Simulink model is developed that obtains wind profiles and, by applying real wind turbine characteristics in dynamics and rotational speed of dc motor, calculates the command shaft torque of a real wind turbine. Based on the comparison between calculated torques with command one, the shaft torque of dc motor is regulated accordingly by controlling armature current demand of a single-phase half-controlled ac–dc converter. Simulation and experimental results confirm the effectiveness of proposed wind turbine simulator in emulating and therefore evaluating various turbines under a wide variety of wind conditions.  相似文献   

8.
Matthew A. Lackner 《风能》2013,16(3):435-444
This paper investigates the loads on offshore floating wind turbines and a new control method that can be used to reduce these loads. In this variable power collective pitch control method, the rated generator speed, which is the set point that the collective pitch control attempts to drive the actual generator speed towards, is no longer a constant value but instead is a variable that depends on the platform pitch velocity. At a basic physical level, this controller achieves the following: as the rotor of a floating turbine pitches upwind, the controller adjusts so as to extract more energy from the wind by increasing the rated generator speed and thus damps the motion; as the rotor pitches downwind, less energy is extracted because the controller reduces the rated generator speed and again damps the motion. This method is applied to the NREL 5 MW wind turbine model, in above rated conditions where the platform motion is most problematic. The results indicate significant load reductions on key structural components, at the expense of minor increases in power and speed variability. The loads on the blades and tower are investigated more generally, and simple dynamic models are used to gain insight into the behavior of floating wind turbine systems. It is clear that for this particular design, aerodynamic methods for reducing platform motion and tower loads are likely inadequate to allow for a viable design, so new designs or possibly new control degrees of freedom are needed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

9.
The design of a PID pitch angle controller for a fixed speed active-stall wind turbine, using the root locus method is described in this paper. The purpose of this controller is to enable an active-stall wind turbine to perform power system stabilisation. For the purpose of controller design, the transfer function of the wind turbine is derived from the wind turbine's step response. The performance of this controller is tested by simulation, where the wind turbine model with its pitch angle controller is connected to a power system model. The power system model employed here is a realistic model of the North European power system. A short circuit fault on a busbar close to the wind turbine generator is simulated, and the dynamic responses of the system with and without the power system stabilisation of the wind turbines are presented. Simulations show that in most operating points the pitch controller can effectively contribute to power system stabilisation.  相似文献   

10.
Matthew A. Lackner 《风能》2013,16(4):519-528
This paper investigates the loads on offshore floating wind turbines and a new control method that can be used to reduce these loads. In this variable power collective pitch control method, the rated generator speed, which is the set point that the collective pitch control attempts to drive the actual generator speed towards, is no longer a constant value but instead a variable that depends on the platform pitch velocity. At a basic physical level, this controller achieves the following: as the rotor of a floating turbine pitches upwind, the controller adjusts so as to extract more energy from the wind by increasing the rated generator speed and thus damps the motion; as the rotor pitches downwind, less energy is extracted because the controller reduces the rated generator speed and again damps the motion. This method is applied to the NREL 5 MW wind turbine model, in above‐rated conditions where the platform motion is most problematic. The results indicate significant load reductions on key structural components, at the expense of minor increases in power and speed variability. The loads on the blades and tower are investigated more generally, and simple dynamic models are used to gain insight into the behavior of floating wind turbine systems. It is clear that for this particular design, aerodynamic methods for reducing platform motion and tower loads are likely inadequate to allow for a viable design, and so new designs or possibly new control degrees of freedom are needed. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

11.
A complete mathematical model of a hydraulic transmission concept for use in wind turbines is presented. The hydraulic system transfers the power from the nacelle to ground level. The main focus has been to develop a model that takes into account the most important dynamics affecting the wind turbine and the hydraulic transmission system involved, such that the model can be used to analyze the dynamic feasibility of a hydraulic transmission concept. Further, dynamic analysis of a hydraulic transmission system for wind turbines is investigated. The nonlinear dynamic model is developed in MATLAB Simulink. Analytical calculation of natural periods of a linearized model corresponds well with simulations of the overall system. A valve control system is proposed to reduce pressure and power fluctuations at operation both below and above the rated wind speed for the wind turbine. Further, a blade pitch control system based on an aerodynamic power estimator is proposed for operation above the rated wind speed. System simulations for one case below and one case above the rated wind speed show that the dynamic response of the overall system is stable and that the wind turbine variables are within typical ranges for conventional variable speed wind turbines with mechanical transmission. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

12.
为探究不同海况及伺服系统下单桩式近海风力机的地震易损性,以DTU 10 MW风力机为研究对象,建立风浪相关的地震-湍流风-波浪多物理场模型,研究其在变速变桨伺服系统下的动力特性,基于增量动力分析方法评估其地震易损性。结果表明:变速变桨伺服系统可有效缓解风力机高风速下无地震作用时的塔顶振动;当风轮在大推力下,较小的波浪载荷一定程度上可降低风力机塔顶振动及塔底弯矩;随地震动强度增加,风力机各临界损伤状态失效概率逐渐增加;风力机地震易损性主要由地震动强度决定,波浪载荷与湍流风载荷对风力机地震易损性影响较小。  相似文献   

13.
Output power of wind turbine generator (WTG) is not constant and fluctuates due to wind speed changes. To reduce the adverse effects of the power system introducing WTGs, there are several published reports on output power control of WTGs detailing various researches based on pitch angle control, variable speed wind turbines, energy storage systems, and so on. In this context, this paper presents an integrated control method for a WF to reduce frequency deviations in a small power system. In this study, the WF achieves the frequency control with two control schemes: load estimation and short-term ahead wind speed prediction. For load estimation in the small power system, a minimal-order observer is used as disturbance observer. The estimated load is utilized to determine the output power command of the WF. To regulate the output power command of the WF according to wind speed changing, short-term ahead wind speed is predicted by using least-squares method. The predicted wind speed adjusts the output power command of the WF as a multiplying factor with fuzzy reasoning. By means of the proposed method, the WF can operate according to the wind and load conditions. In the WF system, each output power of the WTGs is controlled by regulating each pitch angle. For increasing acquisition power of the WF, a dispatch control method also is proposed. In the pitch angle control system of each WTG, generalized predictive control (GPC) is applied to enhance the control performance. Effectiveness of the proposed method is verified by the numerical simulations.  相似文献   

14.
风电机组参与调频时其输出功率的调整将改变风电机组变桨动作的风速范围,同时由于桨距角调节气动功率的灵敏度随风况变化,使得传统PI变桨控制难以适用于风电机组参与调频时的复杂工况,出现风电机组转速振荡问题。提出一种基于线性变参数(Linear Parameter Varying, LPV)系统的风电机组变桨控制方法,对风电机组模型进行线性化,根据风速和桨距角的变化范围进行凸分解,得到其具有四面体结构的LPV模型,通过求解不同平衡点处的线性矩阵不等式(Linear Matrix Inequality, LMI)设计出相应的变桨控制器。仿真结果表明:与传统PI变桨控制相比,LPV变桨控制能有效减小转速的波动,降低低速轴载荷以及减小桨距角的波动程度,验证了该控制策略的有效性和先进性。  相似文献   

15.
In this paper the dynamics of a small autonomous system, comprising a diesel generator and a wind turbine, are investigated. The analysis is performed both in the frequency and time domain, using simplified models of the system components and taking into account the diesel engine speed governor and the wind turbine pitch controller (for pitch regulated machines). The investigation is extended to include different types of wind turbines, equipped with induction or synchronous generator and using pitch or stall regulation, as well as operation of the wind turbine in an autonomous or infinite system. The objective is to determine the main factors affecting the behaviour of the system and to illustrate the effect of the speed governor and pitch controller settings on the expected performance. Particular emphasis is placed on identifying the main modes of the system and determining their dependence on the controllers' parameters. A comparative assessment of the dynamic characteristics of different types of wind turbines is also included and the operation of the wind turbine in a small system and against an infinite bus is addressed and discussed.  相似文献   

16.
Grid connected wind turbines may produce flicker during continuous operation. This paper presents a simulation model of a MW-level variable speed wind turbine with a doubly fed induction generator developed in the simulation tool of PSCAD/EMTDC. Flicker emission of variable speed wind turbines with doubly fed induction generators is investigated during continuous operation, and the dependence of flicker emission on mean wind speed, wind turbulence intensity, short circuit capacity of grid and grid impedance angle are analyzed. A comparison is done with the fixed speed wind turbine, which leads to a conclusion that the factors mentioned above have different influences on flicker emission compared with that in the case of the fixed speed wind turbine. Flicker mitigation is realized by output reactive power control of the variable speed wind turbine with doubly fed induction generator. Simulation results show the wind turbine output reactive power control provides an effective means for flicker mitigation regardless of mean wind speed, turbulence intensity and short circuit capacity ratio.  相似文献   

17.
A multi‐body aeroelastic design code based on the implementation of the combined aeroelastic beam element is extended to cover closed loop operation conditions of wind turbines. The equations of a controller for variable generator speed and pitch‐controlled operation in high wind speeds are combined with the aeroelastic equations of motion for the complete wind turbine, in order to provide a compound aeroservoelastic system of equations. The control equations comprise linear differential equations for the pitch and generator torque actuators, the control feedback elements (proportional–integral control) and the various filters acting on the feedback signals. In its non‐linear form, the dynamic equations are integrated in time to provide the reference state, while upon linearization of the system and transformation in the non‐rotating frame, the linear stability equations are derived. Stability results for a multi‐MW wind turbine show that the coupling of the controller dynamics with the aeroelastic dynamics of the machine is important and must be taken into account in view of defining the controller parameters. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

18.
采用计算流体力学方法(CFD)针对垂直轴风力发电机,开展简化的二维绕流特性研究。首先,基于开放型转子和增强型转子,研究网格节点数和壁面y+、计算时间步长和湍流模型等的变化对计算结果的影响,对计算模型和方法进行确认。随后,计算分析增强型垂直轴风力机与开放型垂直轴风力机的特性。结果表明,与开放性垂直轴风力发电机相比,增强型垂直轴风力发电机的功率系数和转矩系数有明显增加,且达到最大值的位置向叶尖速比增大的方向移动。然后对增强型垂直轴风力机发电机在不同来流风速下进行计算,发现增强型垂直轴风力发电机的转子转矩随来流风速增加,而转矩系数和功率系数与来流风速无关。最后,针对定子叶片在不同的方向开展计算研究。结果表明,定子叶片在不同方向时,增强型垂直轴风力机的转子转矩不同,且转矩到达峰值的位置也不同;在当前3个方向角中,叶片处于0°方向角时风力机具有最高的转矩系数,即具有最佳的功率系数。  相似文献   

19.
Modern wind turbines are predominantly variable speed wind turbines with power electronic interface. Emphasis in this paper is therefore on the modelling and control issues of these wind turbine concepts and especially on their impact on the power system. The models and control are developed and implemented in the power system simulation tool DIgSILENT. Important issues like the fault ride‐through and grid support capabilities of these wind turbine concepts are addressed. The paper reveals that advanced control of variable speed wind turbines can improve power system stability. Finally, it will be shown in the paper that wind parks consisting of variable speed wind turbines can help nearby connected fixed speed wind turbines to ride‐through grid faults. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
关注国内研究较少的风力发电机的特殊状态,基于FAST平台选择了特定的变桨距风力发电机模型,对于风力发电机的启动、关机和故障过程3大类中的7个特殊状态进行了仿真实验。将所得结果在MATLAB中绘图,得到了风力发电机风轮转速和发电机电磁功率在各个特殊状态下随时间变化的曲线,并对各个过程进行了简要的分析。  相似文献   