首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This paper presents a new robust and effective control strategy to mitigate symmetrical voltage dips in a grid‐connected doubly fed induction generator (DFIG) wind energy conversion system without any additional hardware in the system. The aim is to control the power transmitted to the grid so as to keep the electrical and mechanical quantities above their threshold protection values during a voltage dip transient. To achieve this, the references of the powers are readjusted to adapt the wind energy conversion system to the fault conditions. Robust control strategies, combining the merits of sliding mode theory and fuzzy logic, are then proposed in this paper. These controllers are derived from the dynamic model of the DFIG considering the variations in the stator flux generated by the voltage drop. This approach is found to yield better performance than other control design methods which assume the flux in the stator to remain constant in amplitude. This control scheme is compliant with the fault‐ride‐through grid codes which require the wind turbine generator to remain connected during voltage dips. A series of simulation scenarios are carried out on a 3‐MW wind turbine system to demonstrate the effectiveness of the proposed control schemes under voltage dips and parameter uncertainty conditions.  相似文献   

2.
Wind turbine manufacturers are required by transmission system operators for fault ride‐through capability as the penetration of wind energy in the electrical systems grows. For this reason, testing and modeling of wind turbines and wind farms are required by the national grid codes to verify the fulfillment of this capability. Therefore, wind turbine models are required to simulate the evolution of voltage, current, reactive and active power during faults. The simulation results obtained from these wind turbine models are used for verification, validation and certification against the real wind turbines measurement results, although evolution of electrical variables during the fault and its clearance is not easy to fulfill. The purpose of this paper is to show the different stages involved in the fulfillment of the procedure of operation for fault ride‐through capability of the Spanish national grid code (PO 12.3) and the ‘procedure for verification, validation and certification of the requirements of the PO 12.3 on the response of wind farms in the event of voltage dips’. The process has been applied to a wind farm composed of Gamesa G52 wind turbines, and the results obtained are presented. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

3.
The energy capacitor system (ECS), composed of power electronic devices and electric double layer capacitor to enhance the low voltage ride through (LVRT) capability of fixed speed wind turbine generator system (WTGS) during network disturbance, is discussed. Control scheme of ECS is based on a sinusoidal pulse width modulation voltage source converter and DC?DC buck/boost converter composed of insulated gate bipolar transistors. Two-mass drive train model of WTGS is adopted because the drive train system modelling has great influence on the characteristics of wind generator system during network fault. Extensive analysis of symmetrical fault is performed with different voltage dip magnitudes and different time durations. Permanent fault because of unsuccessful reclosing is also analysed, which is one of the salient features of this study. A real grid code defined in the power system is considered and LVRT characteristic of WTGS is analysed. Finally, it is concluded that ECS (20 MW) can significantly enhance the LVRT capability of grid connected WTGS (50 MW) during network disturbance, where simulations have been carried out by using PSCAD/EMTDC.  相似文献   

4.
[目的]为改进半直驱风电系统的故障电压穿越(Flexible Fault Ride Through, FFRT)能力,提出采用电网故障时无功优先的改进网侧控制策略。[方法]在分析传统网侧控制策略的基础上,根据最新的故障电压穿越能力测试规程在传统网侧控制加入无功优先控制,在电网暂态故障期间优先向电网注入无功电流支撑电网电压恢复。根据改进网侧控制策略,对电网深度跌落和升高时采用卸荷电路结合改进网侧控制策略实现了风电机组的FFRT仿真运行,结合某项目6 MW半直驱风电机组,采用移动故障电压穿越测试设备进行故障电压现场测试。[结果]测试和仿真结果表明,改进网侧控制策略可提升半直驱风电系统的FFRT运行,无功电流稳定控制。[结论]改进网侧控制策略可在多种对称低电压/高电压故障工况和不对称高电压故障工况下优先向电网注入对应的稳定无功电流,有利于辅助电网电压恢复和提升半直驱风电系统的FFRT能力。  相似文献   

5.
This paper statistically examine wind characteristics from seven meteorological stations within the North-West (NW) geo-political region of Nigeria using 36-year (1971–2007) wind speed data measured at 10 m height subjected to 2-parameter Weibull analysis. It is observed that the monthly mean wind speed in this region ranges from 2.64 m/s to 9.83 m/s. The minimum monthly mean wind speed was recorded in Yelwa in the month of November while the maximum value is observed in Katsina in the month of June. The annual wind speeds range from 3.61 m/s in Yelwa to 7.77 m/s in Kano. It is further shown that Sokoto, Katsina and Kano are suitable locations for wind turbine installations with annual mean wind speeds of 7.61, 7.45 and 7.77 m/s, respectively. The results also suggest that Gusau and Zaria should be applicable for wind energy development using taller wind turbine towers due to their respective annual mean speeds and mean power density while Kaduna is considered as marginal. In addition, higher wind speeds were recorded in the morning hours than afternoon periods for this region. A technical electricity generation assessment using four commercial wind turbines were carried out. The results indicate that, while the highest annual power is obtained with Nordex N80–2.5 MW as 14233.53 kW/year in Kano, the lowest is in Yelwa having 618.06 kW/year for Suzlon S52. It is further shown that the highest capacity factor is 64.95% for Suzlon S52–600 kW in Kano while the lowest is 3.82% for Vestas V80–2 MW in Yelwa.  相似文献   

6.
This paper adds the new Spanish grid code to the previously published works about the comparison of international regulations for connection of wind turbines to the network. All the electrical magnitudes—currents and active and reactive power—regulated in the Spanish grid code are studied when the wind turbines are submitted to real voltage dips. Because grid codes and, specifically, the Spanish grid code do not fix the reactive power definition to be applied, four definitions commonly used have also been studied. Taking advantage of the voltage dips field tests carried out to the Gamesa G80 wind turbines, the results obtained for two representative voltage dip tests are presented: a three‐phase and a phase‐to‐phase voltage dip. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

7.
对于电压跌落,存在电压连续两次跌落的现象。指出了电压会发生两次跌落的现象,分析了双馈型风电机组在电压跌落过程中定子磁链衰减变化现象。结果表明在电压发生第二次跌落时,应考虑定子磁链初始值的问题。通过现场试验结果,验证了未考虑定子磁链初始值,两次电压跌落的间隔时间不同对风电机组的影响。  相似文献   

8.
This paper investigates the impact of extreme events on the planet bearings of a 5 MW gearbox. The system is simulated using an aeroelastic tool, where the turbine structure is modeled, and MATLAB/Simulink, where the drivetrain (gearbox and generator) are modeled using a lumped‐parameter approach. Three extreme events are assessed: low‐voltage ride through, emergency stop and normal stop. The analysis is focused on finding which event has the most negative impact on the bearing extreme radial loads. The two latter events are carried out following the guidelines of the International Electrotechnical Commission standard 61400‐1. The former is carried out by applying a voltage fault while simulating the wind turbine under normal turbulent wind conditions. The voltage faults are defined by following the guidelines from four different grid codes in order to assess the impact on the bearings. The results show that the grid code specifications have a dominant role in the maximum loads achieved by the bearings during a low‐voltage ride through. Moreover, the emergency brake shows the highest impact by increasing the bearing loads up to three times the rated value. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
凌禹 《太阳能学报》2022,43(12):312-319
基于传统矢量控制技术,该文提出一种改进的矢量控制技术来抑制双馈感应电机故障期间的转子过电流,以提高双馈风电机组故障穿越能力。从分析传统矢量控制技术入手,提出一种改进的矢量控制技术,其主要特点是反映定子电压瞬态对转子电流的影响,但并未增加控制的复杂程度。从理论的角度对所提方案能提高双馈风电机组故障穿越能力的机理进行深入分析。最后,对基于PSCAD/EMTDC软件环境下搭建的2 MW双馈风电机组模型进行仿真研究。仿真结果表明所提方案能有效抑制双馈感应电机故障期间的转子过电流,从而提高双馈风电机组的故障穿越能力。  相似文献   

10.
为探究大型水平轴风力机达到切出风速停机后变桨故障叶片的气动特性及准静态结构响应,基于计算流体力学方法对NREL 5 MW风力机变桨故障/成功叶片气动侧状态进行分析,并利用双向弱流固耦合及曲屈分析对典型方位角下变桨故障叶片展开研究。结果显示:切出风速下变桨故障叶片挥舞力矩平均值为变桨成功叶片的13.8倍,且前者的流场尾迹更为明显。此外,180°方位角变桨故障叶片较之0°方位角变桨故障叶片应力及叶尖位移分别减小29.8%和32.7%,一阶屈曲因子增加20.2%。  相似文献   

11.
It is likely that intermittent renewable sources such as wind and solar will provide the greatest opportunity for future large-scale hydrogen production. Here, on-shore wind is examined. Global wind energy is estimated by placing one 2 MW turbine/km2 over the surface of the earth. Wind energy production is based on monthly mean wind speed data. Wind turbines are grouped to form arrays that are linked to local hydrogen generation and transmission networks. Hydrogen generation is done via low-pressure electrolysis and transmission via high-pressure gas pipelines. The wind/hydrogen system is considered within a global energy system that must not only provide hydrogen, but also energy for electricity consumption at the local generation site. The technical potential of the hydrogen produced is estimated to be 116 EJ. Uneven distribution of the hydrogen-rich sites results in the need to export much of the hydrogen produced to energy-poor regions. To overcome system losses, a combined wind/HVDC/hydrogen system is considered.  相似文献   

12.
This work presents the results of in‐field tests performed on a 2.5 MW, 80 m diameter wind turbine. During the two test campaigns, dynamic response of the structure was monitored by using three different measurement systems, namely conventional strain gauges, photogrammetry and laser interferometry, whereas the turbine was both at parked condition and rotating. The recorded data were analysed by using an operational modal analysis algorithm based on the least square complex exponential method and several turbine parameters (eigenfrequencies and damping ratios) were extracted. The obtained system parameters were then qualitatively compared with the results presented in a study from literature, which includes both aeroelastic simulations and in‐field measurements performed on a similar size and capacity wind turbine. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

13.
A prototype 3 kW horizontal upwind type wind turbine generator of 4 m in diameter has been designed and examined under real wind conditions. The machine was designed based on the concept that even small wind turbines should have a variable pitch control system just as large wind turbines, especially in Japan where typhoons occur at least once a year. A characteristic of the machine is the use of a worm and gear system with a stepping motor installed in the center of the hub, and the rotational main shaft. The machine is constructed with no mechanical breaking system so as to avoid damage from strong winds. In a storm, the wind turbine is slowed down by adjusting the pitch angle and the maximum electrical load. Usually the machine is controlled at several stages depending on the rotational speed of the blades. Two control methods have been applied: the variable pitch angle, and regulation of the generator field current. The characteristics of the generator under each rotational speed and field current are first investigated in the laboratory. This paper describes the performances of the wind turbine in terms of the functions of wind turbine rotational speed, generated outputs, and its stability for wind speed changes. The expected performances of the machine have been confirmed under real wind conditions and compared with numerical simulation results. The wind turbine showed a power coefficient of 0.257 under the average wind speed of 7.3 m/s.  相似文献   

14.
《Journal of power sources》2006,162(2):943-948
This paper describes a novel method of modelling an energy store used to match the power output from a wind turbine and a solar PV array to a varying electrical load. The model estimates the fraction of time that an energy store spends full or empty. It can also estimate the power curtailed when the store is full and the unsatisfied demand when the store is empty. The new modelling method has been validated against time–stepping methods and shows generally good agreement over a wide range of store power ratings, store efficiencies, wind turbine capacities and solar PV capacities.Example results are presented for a system with 1 MW of wind power capacity, 2 MW of photovoltaic capacity, an energy store of 75% efficiency and a range of loads from 0 to 3 MW average.  相似文献   

15.
16.
Wind Energy Conversion System (WECS) based on Doubly Fed Induction Generator (DFIG) connected to the grid is subjected to high transient currents at rotor side and rise in DC-link voltage during voltage sag at stator/grid side. To secure power system operation wind turbines have to meet grid requirements through the Low voltage ride through (LVRT) capability and contribute to grid voltage control during severe situations. This paper presents the modeling and control designs for WECS based on a real model of DFIG taking into account the effect of stator resistance. The non-linear control technique using sliding mode control (SMC) strategy is used to alter the dynamics of 1.5 MW wind turbine system connected to the grid under severe faults of grid voltage. The paper, also discusses the transient behavior and points out the performance limit for LVRT by using two protection circuits of an AC-crowbar and a DC-Chopper which follow a developed flowchart of system protection modes under fault which achieved LVRT requirements through results. The model has been implemented in MATLAB/SIMULINK for both rotor and grid side converters.  相似文献   

17.
High penetration of wind generation challenges wind turbine operators to supply reliable power and extract optimum power from the wind. Hence, the fault ride through (FRT) capability of wind turbine together with the optimum power tracking and regulation of wind turbine output voltage due to fluctuating nature of the wind becomes essential. In this paper, a method is proposed to ensure that the double fed induction generator (DFIG) wind turbine continues to operate during severe grid faults and maintains a constant output voltage, irrespective of the fluctuating wind. The proposed controller also allows the DFIG wind turbine to track optimum power from the wind. Extensive simulation is performed using PSCAD/EMTDC software and results obtained show that the DFIG output voltage fulfills the grid code requirements. The results also show that the proposed method is able to track the optimum power, regulate the DFIG output voltage and perform fault ride through of wind turbine.  相似文献   

18.
Egypt is one of the Red Sea and Mediterranean countries having windy enough areas, in particular along the coasts. The coastal location Ras Ghareb on the Red Sea has been investigated in order to know the wind power density available for electricity generation. To account for the wind potential variations with height, a new simple estimating procedure was introduced. This study has explicitly demonstrated the presence of high wind power density nearly 900 kW/m2 per year at 100 m of altitude for this region. Indeed, the seasonal wind powers available are comparable to and sometimes higher than the power density in many European cities for wind electricity applications like Vindeby (Denmark) and also America.New technical analysis for wind turbine characteristics have been made using three types of commercial wind turbines possessing the same rotor diameter and rated power to choice the best wind machine suitable for Ras Ghareb station. As per the decreasing the cut-in wind speed for the wind turbine used, the availability factor increases for a given generator. That it could produce more energy output throughout the year for the location.The aim of this research, was to predict the electrical energy production with the cost analysis of a wind farm 150 MW total power installed at Ras Ghareb area using 100 wind turbines model (Repower MD 77) with 1.5 MW rated power. Additionally, this paper developed the methodology for estimating the price of each kWh electricity from the wind farms. Results show that this wind park will produce maximum energy of 716 GWh/year. The expected specific cost equal to 1.5 € cent/kWh is still less than and very competitive price with that produced from the wind farms in Great Britain and Germany and at the international markets of wind power. The important result derived from this study encourages several wind parks with hundreds of megawatts can be constructed at Ras Ghareb region.  相似文献   

19.
This paper presents a positive approach for low voltage ride-through (LVRT) improvement of the permanent magnet synchronous generator (PMSG) based on a large wind power plant (WPP) of 50 MW. The proposed method utilizes the conventional current control strategy to provide a reactive power requirement and retain the active power production during and after the fault for the grid codes compliance. Besides that, a resistive superconducting fault current limiter (RSFCL) as an additional self-healing support is applied outside the WPP to further increase the rated active power of the installation, thereby enhance the dc-link voltage smoothness, as well as the LVRT capability of the 50 MW WPP. This is achieved by limiting the exceed fault current and diminishing the voltage dip level, leading to increase the voltage safety margin of the LVRT curve. Furthermore, the effect of the installed RSFCL on the extreme load reduction is effectively demonstrated. A large WPP has a complicated structure using several components, and the inclusion of RSFCL composes this layout more problematic for optimal performance of the system. Hence, the most-widely decision-making technique based on the analytic hierarchy process (AHP) is proposed for the optimal design of the combinatorial RSFCL and 50 MW WPP to compute the three-dimensional alignment in Pareto front at the end of the optimization run. The numerical simulations verify effectiveness of the proposed approach, using the Pareto optimality concept.  相似文献   

20.
为研究并网双馈风力发电机组的机电耦合作用对机组暂态性能的影响,采用等效集中质量法,在Mat-lab/Simulink环境下,提出一种基于叶片弯曲柔性和传动轴扭转柔性的风力发电机组3质量块等效模型。结合双馈发电机控制策略,分别以额定功率750 kW和3 MW的风力发电机组为例,对其在电网电压跌落和机械扰动两种情况下进行暂态稳定性仿真,并将仿真结果和传统的1质量块、2质量块等效模型的仿真结果进行比较分析。结果表明:随着单机容量的增加,叶片的柔性对机组暂态稳定性的影响逐渐增大,建立3质量块等效模型对研究大容量双馈风力发电机组暂态稳定性是必要和有效的。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号