共查询到18条相似文献,搜索用时 78 毫秒
1.
2.
3.
4.
5.
6.
建立商超用NH3/CO2复叠双温制冷系统的热力学模型,拟合压缩机的等熵效率,并对系统运行参数进行计算分析。将某工况下的模拟计算结果与试验测试数据进行对比,验证系统模型的合理性。结果显示:不同中低温蒸发温度对制冷系统性能均具有影响,且系统制冷系数(COP)随中温蒸发温度的升高呈现先增大后减少的趋势。工况一定时,高温冷凝温度越低,系统COP越高;蒸发冷凝器的传热温差越大,高低温级间制冷剂流量比越小,则系统COP越低;提升NH3的冷凝过冷度,降低其蒸发过热度,均对提升系统COP具有积极作用。研究结果对NH3/CO2复叠双温制冷系统的理论研究与技术发展具有较好的指导意义。 相似文献
7.
8.
以CO2跨临界循环冷热联供系统为研究对象,通过理论计算分析了传热窄点温差约束下系统供热温度、供冷温度、制热系数(COPh)和制冷系数(COPc)随压缩机排气压强、气体冷却器出口工质温度和蒸发温度的变化规律。结果表明:供热温度随压缩机排气压强和气体冷却器出口工质温度的提高而升高,随蒸发温度的提高而降低;供冷温度只随蒸发温度变化;COPh和COPc随气体冷却器出口工质温度的提高而减小,随蒸发温度的提高而增大;当气体冷却器出口工质温度为30~40 ℃时,随压缩机排气压强的增大,COP减小,当气体冷却器出口工质温度为45 ℃时,COP先增大后减小;在考察工况下,当蒸发温度为-25 ℃、气体冷却器出口温度为45 ℃时,循环系统在压缩机排气压强为14 MPa可以达到最大供热温度120.65 ℃、最低供冷温度-15 ℃,此时系统COP为2.94。 相似文献
9.
通过对NH3/CO2、R290/CO2和R404A/CO2三种复叠式制冷系统的COP、最优低温循环冷凝温度和最佳质量流量比等进行理论分析及性能比较,得出在一定的蒸发温度、冷凝温度和冷凝蒸发器传热温差下,三种复叠式制冷系统的COP都随着低温循环冷凝温度的升高呈现出先增大后减少的趋势,其中NH3/CO2复叠式制冷系统的COP最大;三种复叠式制冷系统的最佳低温循环冷凝温度和最佳质量流量比都随着蒸发温度的升高而升高,其中R404A/CO2复叠式制冷系统的最佳低温循环冷凝温度最高,NH3/CO2复叠式制冷系统的最佳质量流量比最大。 相似文献
10.
11.
The objective of this work is the investigation of an alternative refrigeration system, which combines a supermarket CO2 booster system with an organic Rankine cycle. The waste heat after the high-pressure compressor is used in order to feed the organic Rankine cycle for electricity production. The working fluid in the organic Rankine cycle is selected to be the octamethyltrisiloxane (MDM), which has a low global warming potential, and so all the used working fluids in the system are environmentally friendly. The system is studied in the transcritical region for ambient temperatures from 27°C to 40°C. In every case, the system is optimized in order to minimize the overall electricity demand. According to the final results, the system coefficient of performance (COP) can be enhanced from 4.83% to 7.60%, while the electricity consumption can be reduced from 4.60% to 7.03% compared with the conventional booster system. Higher enhancements are found in cases with higher ambient temperatures. Furthermore, a preliminary financial study indicates that the examined idea is viable with the simple payback period to be 5.45 years. The present study is conducted by using a homemade model written in Engineering Equation Solver. 相似文献
12.
Commercial refrigeration systems in supermarkets are intensive users of energy and CO2 is recognized as the most promising refrigerant such systems. The CO2 parallel compression system has been considered in medium- and low-temperature supermarket refrigeration systems, with auxiliary compressors to enhance system performance. This study is intended to investigate the effects of adding a subcooler in a CO2 trans-critical supermarket refrigeration system with parallel compression (SPR system). Mathematical models based on mass and energy conservation are built. Optimization is performed for the gas cooler pressure and the receiver pressure for maximizing the coefficient of performance (COP). The performance of the parallel compression system with a subcooler is analyzed and compared to a baseline parallel compression system in different cities of China. A 6.8% average promotion at least in seasonal energy efficiency ratio (SEER) is predicted, and the energy consumption of the whole system decreases 7.1% totally in Haikou. Gas cooler, taking up 63.3% of the total exergy destruction rate, is the key component to increase efficiency through exergy analysis. 相似文献
13.
针对中原地区典型气象年(辐射极大)的冬季气象条件,通过所建立的跨临界循环热泵系统性能模拟平台,计算并对比分析了太阳能辅助R744跨临界循环及单一R744热泵系统在中原地区的运行特性;讨论了热水出水温度、传热窄点温差改变时系统制热性能系数和最优放热侧压力的变化规律。研究结果表明,在设定工况下,联合应用太阳能集热系统,R744热泵系统性能在冬季可得到大幅度提高,平均提高34.4%;热水出水温度低于70℃时,系统性能提高幅度超过36.0%;但传热窄点温差增大,系统性能有一定程度下降。 相似文献
14.
利用过冷器将超市的空调系统和商用冷冻系统联合起来,利用空调的冷冻水给商用冷冻系统提供过冷,提高冷冻系统的COP值,降低冷冻系统的运行能耗,从整体上降低了超市的电能消耗,同时可减少工程初投资,是超市节能的一种新方法,具有良好的经济效益和节能环保效益。 相似文献
15.
对R744/R290、R744/R600a混合自然工质的热力性质进行分析比较,并将它们用于自复叠制冷循环,对系统的循环特性进行分析。经过计算,得出了两种混合工质制冷性质的不同点及环境温度、制冷温度、混合工质中R744浓度对系统性能的影响。为今后R744/R290、R744/R600a的实验研究和实际应用提供了理论依据,减少了实验的工作量。 相似文献
16.
为了实现低温热能的充分回收利用,在混合工质ORC循环发电基础上,提出一种利用CO_2跨临界循环与其耦合的发电系统。基于热力学第一、第二定律,建立相应热力学模型,并编写计算程序,确定系统运行条件,分析蒸发温度T1、跨临界蒸发压力p01及热源温度T_g等参数变化对耦合系统性能的影响,并将其与采用相同混合工质的ORC系统进行比较。结果表明:随蒸发温度提高,跨临界循环部分输出功逐渐增加,而ORC部分由于冷凝温度提升所减少的输出功逐渐降低。在T_g为373.00K时,若T_1为340.00、354.00K,耦合系统较基本ORC系统输出功分别增加15.77、113.53kW。随跨临界蒸发压力p_(01)变化,耦合系统输出功及效率均有先减小后增加再降低的规律,存在一最佳跨临界压力,且表现为随热源温度降低,耦合系统性能优越性逐渐明显。若T_g为373.00或403.00K,则耦合系统较基本ORC系统分别增加19.16、7.18kW。在蒸发温度较高或热源温度较低时,采用耦合系统具有重要意义。 相似文献
17.
虽然二氧化碳跨临界循环成为最具潜力的工质替代技术,但其循环的效率还是比常规工质循环低,因此开发膨胀机提高二氧化碳跨临界循环系统运行效率是推动实际应用的关键问题。本文给出了二氧化碳膨胀机的设计特点,同时利用实验手段对带膨胀机的二氧化碳跨临界循环水源热泵系统进行测试,了解膨胀机的运行特性以及对系统的影响,同时改变外部参数条件,了解系统运行规律。通过实验表明,膨胀机的运行效率与膨胀机的转速有关,而且存在极值。系统的运行也受其影响,但系统性能系数是一个综合作用的结果,应对系统运行参数进行优化。 相似文献