首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
The aim of this study is to isolate denitrifying bacteria utilizing epsilon-caprolactam as the substrate, from a polyacrylonitrile fibre manufactured wastewater treatment system. The aim is also to compare the performance of PAN (polyacrylonitrile) mixed bacteria cultures acclimated to epsilon-caprolactam and isolated pure strain for treating different initial epsilon-caprolactam concentrations from synthetic wastewater under anoxic conditions. The result showed that the PAN mixed bacteria cultures acclimated to epsilon-caprolactam could utilize 1538.5 mg/l of epsilon-caprolactam as a substrate for denitrification. Sufficient time and about 2200 mg/l of nitrate were necessary for the complete epsilon-caprolactam removal. Paracoccus thiophilus was isolated from the polyacrylonitrile fibre manufactured wastewater treatment system and it could utilize 1722.5 mg/l of epsilon-caprolactam as a substrate for denitrification. About 3500 mg/l of nitrate was necessary for the complete removal of epsilon-caprolactam. When the initial epsilon-caprolactam concentration was below 784.3 mg/l, the removal efficiency of epsilon-caprolactam by Paracoccus thiophilus was better than that for the PAN mixed bacteria cultures. The growth of Paracoccus thiophilus was better. However, when the initial epsilon-caprolactam concentration was as high as 1445.8 mg/l, both the epsilon-caprolactam removal efficiency by Paracoccus thiophilus and Paracoccus thiophilus specific growth rate were similar to the PAN mixed bacteria cultures.  相似文献   

2.
The optimization of the Benchmark Simulation Model 1 (BSM1) through a multi objective genetic algorithm (MOGA) is studied in this paper. First, the optimization of the set points of the two Proportional Integral (PI) controllers proposed in BSM1 is performed. Then, a new controller layout composed of three PI controllers is proposed and the set points are also optimized. Among all performance indexes proposed in BSM1, only the effluent quality and the energy consumption for pumping and aeration were taken into account in both optimization problems. Since these two objectives are conflicting, the use of the MOGA allows in both cases a direct visualization of the possible trade-offs through a Pareto curve. These two case studies showed the feasibility of such optimizations even when dealing with computing intensive model like the full scale waste water treatment plant (WWTP) model.  相似文献   

3.
To supply theoretical verification of the function of a selector to control aerobic activated sludge bulking in the wastewater treatment plant for a chemical fiber factory in Taiwan, the filamentous and floc-forming bacteria in the aeration tank in the full-scale plant were examined microscopically and isolated. The kinetic characteristics of filamentous and floc-forming bacteria were also investigated.The predominant filamentous organism was Sphaerotilus natans. In addition to this organism, 21 strains of non-filamentous bacteria were isolated using the plate count method. These included Aeromonas jandaei DNA group 9, Acinetobacter johnsonii/genospecies 7, Bacillus pasteurii and Bacillus sp. (using the Biolog identification system). Nine strains showed the ability to form flocs when cultivated in glucose mineral salts medium.With glucose and acetate as sole substrates, the 4 floc-forming bacteria tested showed different substrate utilization characteristics. The 4 strains could be divided into 3 groups. The first group was the substrate degrading bacteria, the second group was the acid degrading bacteria and the other strains were those that had the highest substrate degradation rates at low substrate concentrations (below 800 mg/l). None of the floc-formers could utilize ethylene glycol, which is the major wastewater component. The kinetic characteristics of filamentous bacterium S. natans (Km = 4.0 mg glucose/l, Vm = 0.43 μl O2/l) and the flocforming bacterium Aeromonas jandaei DNA group 9 (Km = 34.8 mg glucose/l, Vm = 0.59 μl O2/l) provided information for selector design.  相似文献   

4.
Complaints from the Domingos Martins population about sewage odours in the city made the district attorney order an impact assessment of the odours emitted by the city wastewater treatment plant (WWTP). This study comprised various techniques, models and population surveys. In 2007, an odour emission model proved that the main hydrogen sulphide emitter was the aeration tank of the WWTP (13.5 g h(-1)) and such emissions, according to CALPUFF model, should be perceived in the whole Domingos Martins city centre area. In this area, 58% of those interviewed were annoyed by the WWTP odours. However, in 2009, the odour monitoring panel recorded few odour occurrences. A second population survey showed that hereafter only 20% of those interviewed were annoyed by the WWTP emissions. Odour emission and dispersion models run with 2010 data proved a drastic reduction of the WWTP aeration tank emissions and consequently the city centre was not bothered by WWTP emissions anymore. The odour emission reduction was due to the modification of the WWTP aeration tank system. Despite the odour emission reduction, houses located southeast of the WWTP were still annoyed by sewage odours. However, in this part of the town, other sources of sewage odours have been found.  相似文献   

5.
某城镇污水处理厂设计规模12万m3/d,采用AAO--MBR工艺,为了保证出水TN稳定达标(≤10 mg/L),外加碳源量较大,电耗较高,导致运行成本过高.通过将传统AAO工艺调整为微氧曝气-多段AO工艺运行方式,在实际进水水质明显提高的情况下,改造后出水水质指标均优于改造前的水平,其中TN去除率提高约6%,且外加碳源...  相似文献   

6.
Based on results from bench-scale flow-film-reactors (FFR) and aerated cascade photoreactors, a solar catalytic pilot plant has been built at the site of a textile factory. This plant has an illuminated surface area of 50 m2 and is designed for the treatment of 1 m3 h(-1) of wastewater. The preliminary results are presented and compared with a bench-scale FFR using textile wastewater and dichloroacetic acid. Equivalent degradation kinetics were obtained and it was demonstrated that the solar catalytic technology is able to remove recalcitrant compounds and color. However, on-site optimization is still necessary for wastewater reuse and for an economic application.  相似文献   

7.
As part of an expansion to an average flow of 45.9 million gallons per day (174 mld), the Ypsilanti Community Utilities Authority wastewater treatment plant in the State of Michigan, USA, elected to install ultraviolet disinfection as a replacement for the existing chlorination process. This paper presents a unique methodology used in selecting the best system based on not only the life cycle costs, and O & M considerations but also the participation of the stakeholders. The Team members consisted of representatives of all departments at the Authority, and these Team members made the decision. The Team evaluated all criteria in the office, which was followed by verification at selected sites with similar types of equipment. The selected equipment then was pilot tested for validation of the dose-kill relationship under normal operation and also under reduced irradiation conditions. A low-pressure, high intensity system was selected, based on life-cycle cost, reliability, safety, and ease of operation. This paper describes the unique methodologies used in making that decision. The full-scale system is scheduled for start-up in Spring 2003.  相似文献   

8.
To evaluate the importance of periphyton to nitrogen dynamics in the discharge from wastewater treatment plants (WWTPs), we examined changes in total and inorganic nitrogen content downstream from a WWTP on the Kurose River in Hiroshima Prefecture, Japan. At 0.7 km downstream of the WWTP (point A), NH4+?N was the dominant form of inorganic nitrogen, but concentrations decreased rapidly to 5 km downstream (point B). In contrast, no significant change in the [NO2?+ + NO3?]?N concentration was observed between the two points. Total nitrogen (TN) load decreased significantly between the two points, suggesting that sorption and/or denitrification occurred in the river channel. Potential rates of nitrogen sorption and transformation by periphyton were determined in a loboratory experiment in which changes in the nitrogen content of river water were examined in an acrylic chamber with periphyton. Nitrification and nitrogen removal occurred mainly in the periphyton. The contributions of periphyton activity to TN and NH4+?N decrease in the field, as estimated from the results of the laboratory experiments, were 6–18% and 23–72%, respectively. These results suggest that periphyton plays an important role in decreasing NH4+?N concentration in the discharge from wastewater treatment plants.  相似文献   

9.
Constructed treatment wetlands (CTWs) are unique ecotechnologies that can sustainably treat a range of wastewaters. This study focused on a 0.23 ha vegetated surface-flow CTW polishing nitrate-rich (3-6 mg-N/L) tertiary effluent from a municipal wastewater treatment plant. Water quality was monitored longitudinally in the fall of 2009 and 2010. The CTW cooled water by from around 20 °C to <15 °C in both years. Longitudinal temperature profiles were successfully modeled using an energy balance approach (2009 R(2) = 0.69; 2010 R(2) = 0.92). The magnitude of key model fitting parameters, including albedo (0.1-0.2) and convective transfer coefficient (0.1-0.9 MJ/m(2) d °C), were within ranges reported in the literature. In both years, dissolved oxygen decreased through the wetland from 6-7 mg/L to 3-4 mg/L, yielding an oxygen mass consumption rate of 0.08-0.09 g/m(2) d. Longitudinal nitrate profiles were well represented by the P-k-C* model (2009 R(2) = 0.88; 2010 R(2) = 0.92). First order removal rates were 20.2 m/yr in 2009 and 29.0 m/yr in 2010 at a P value of 6.0. Levels of ammonia and total phosphorus increased negligibly through the wetland, remaining below 0.25 mg/L. This study shows that vegetated surface-flow CTWs are well suited to cool and polish low-BOD nitrate-dominated tertiary effluents with little degradation of other water quality parameters of concern, including phosphorus and ammonia.  相似文献   

10.
徐骏  朱伟 《水资源保护》2014,30(2):62-66
针对污泥中重金属赋存形态尚不明确的问题,使用MacNicol提出的组分分离方法,以3个污水处理厂污泥为对象,研究了重金属在无机颗粒、生物絮团、胶粒、流动相4个组分中的分配情况。结果表明,脱水污泥的干物质中颗粒组分和生物絮团组分约占到了67%~94%,而在脱水污泥中颗粒组分和生物絮团仅占7%~22%,大多数属于流动相。这一组成特性决定了脱水污泥的大部分重金属分布在污泥流动相中,无机颗粒、生物絮团、胶粒中的重金属只占很少一部分。但从赋存浓度来看,流动相重金属浓度很低,相反有机相胶粒组分中重金属浓度较高。  相似文献   

11.
This study was conducted to evaluate the treatability of OMW (olive mill wastewater) with sewage and sewage sludge, which could supplement nutrients and microbes required for OMW treatment and reduce its possible toxicity. The amount of OMW added to an aeration tank was based on the loading difference between the designed and actual COD loads, while the amount added to anaerobic digestion for energy recovery was determined by CH4 production. The COD removal efficiencies were 70-85% for both systems. Compost of OMW with dried sewage sludge also showed a similar temperature profile without OMW addition. This strongly suggested that OMW can be treated at a sewage plant without pretreatment and the treated effluent can be reused in irrigation for an arid region.  相似文献   

12.
A one-year study of the proliferation of mosquito in a Pistia stratiotes-based waste stabilization ponds in Cameroon revealed that Mansonia and Culex were the main breeding genera with about 55% and 42% of the total imagoes respectively. Though the ponds represent a favorable breeding ground for mosquitoes, only 0.02% of captured imagoes was Anopheles gambiae, suggesting that this wastewater treatment plant does not significantly contribute to the development of the malaria vector in the area. Gambusia sp. introduced to control mosquito population in the ponds acclimatized relatively well in most of the ponds (B3-B7) and their feeding rate without any diet ranged from 15.0 to 50.2 larvae/day for a single fish.  相似文献   

13.
Sludge bulking is still a problem in the operation of state-of-the-art wastewater treatment plants (WWTPs). The ozonation of returned activated sludge (RAS) is an innovative option as a non-specific measure for the control of filament growth. The applicability of sludge ozonation for bulking control of a large wastewater treatment plant was investigated. At a full-scale WWTP one lane was equipped with a sludge ozonation plant for RAS. The implemented sludge ozonation of RAS was tested against the two identical references lanes of the same WWTP. The positive effect on settleability could be clearly proven. Low-dose sludge ozonation could be a technical alternative in comparison with the established chemical measures for bulking control.  相似文献   

14.
对某A2/O工艺城市污水处理厂施工建造和运营维护阶段所造成的环境影响进行生命周期评价,并以绿色税收为参考指标概算各环境影响指标造成的经济负担,同时对采用不同污水处理方式的污水处理厂的生命周期评价结果进行比较。结果表明:A2/O工艺城市污水处理厂生命周期内造成的环境影响主要来自运营维护阶段的能量消耗,对水体富营养化的影响较大;相对于某湿地污水处理系统,A2/O工艺城市污水处理厂对非生物资源消耗较大,但在大气酸化、光化学氧化以及全球变暖等方面的影响较小;相对于五阶段Bardenpho工艺,A2/O工艺对水体富营养化具有较大影响,但在非生物资源消耗、全球变暖、光化学氧化、大气酸化等方面影响较小。  相似文献   

15.
Radiotracer incubation experiments and beta microimaging, along with fluorescent in situ hybridisation (FISH), are proposed as a complementary approach to specific methanogenic activity testing and measurement of in vitro substrate utilisation rates to understand better the ecophysiology of anaerobic granular biofilms from wastewater treatment reactors.  相似文献   

16.
事故池作为工业区污水处理厂应急事故处理的核心单元,能够降低因进水水质超标造成的污水处理厂前端溢流,对水环境的安全保护起到至关重要的作用.河南省某综合污水处理厂服务范围内工业企业较多,其事故的最大原因可能由进水水质超标引起.因此事故池依事故范围及进水流量等确定了关键设计参数,并根据厂区工艺主流程设置事故池的节点位置,同时...  相似文献   

17.
三乡镇污水处理厂设计规模2万m3/d,污水处理工艺采用改良CASS法,污泥处理采用浓缩-机械脱水工艺,臭气处理采用分散收集后生物法集中除臭的方法.具体介绍了改良CASS工艺的设计参数、工艺流程及设计特点,为改良CASS工艺克服选址及占地限制提供一定参考.  相似文献   

18.
Residual pharmaceutical products in sewage and other water environments have recently become a serious social problem in advanced countries. Among these pharmaceutical products, antibiotics have attracted special attention due to their serious impact on the ecosystem and connections to the emergence of drug-resistant bacteria. Our research intended to develop a new method to analyse the three antibiotics estimated to be released out of the body in large amounts in Japan; levofloxacin (LVFX), clarithromycin (CAM) and azithromycin (AZM), and survey the state of pollution in the sewerage. The concentrations of the water-phase antibiotics LVFX, CAM and AZM were measured in each process of activated sludge process in six wastewater treatment plants. Liquid chromatography tandem mass spectrometry (LC/MS/MS) was used to analyse solutions of the antibiotics after pretreatment with a solid phase extraction. The limits of quantification and the average recoveries for these antibiotics in the influent were 1.2 to 29 ng/L and 46 to 93%, respectively. In the influent, LVFX, CAM and AZM were detected at concentrations of 552, 647 and 260 ng/L, respectively, while their removal efficiencies were 42, 43 and 49%, respectively. Although the CAM and AZM concentrations decreased as the treatment progressed, it was shown that the LVFX concentration increased in activated sludge reactors in some cases. Despite differences in octanol-water partition coefficients among LVFX, CAM and AZM, their removal efficiency showed no major difference. This indicates that this removal phenomenon cannot be explained by simple adsorption by the activated sludge.  相似文献   

19.
对某燃煤电厂实现废水近零排放目标存在的主要问题进行了分析,对废水来水与回用水不平衡问题提出了综合治理解决方案.提出采用部分辅机冷却水回流来解决辅机冷却用水量与全厂补水量的不平衡问题并进行了可行性论证;综合治理方案实施后电厂单位发电用水量将降低19%,针对该厂末端高盐废水蒸干系统存在的问题,结合目前国内外几种主要高盐废水...  相似文献   

20.
Computer modelling has been used in the last 15 years as a powerful tool for understanding the behaviour of activated sludge wastewater treatment systems. However, computer models are mainly applied for domestic wastewater treatment plants (WWTPs). Application of these types of models to industrial wastewater treatment plants requires a different model structure and an accurate estimation of the kinetics and stoichiometry of the model parameters, which may be different from the ones used for domestic wastewater. Most of these parameters are strongly dependent on the wastewater composition. In this study a modified version of the activated sludge model No. 1 (ASM 1) was used to describe a tannery WWTP. Several biological tests and complementary physical-chemical analyses were performed to characterise the wastewater and sludge composition in the context of activated sludge modelling. The proposed model was calibrated under steady-state conditions and validated under dynamic flow conditions. The model was successfully used to obtain insight into the existing plant performance, possible extension and options for process optimisation. The model illustrated the potential capacity of the plant to achieve full denitrification and to handle a higher hydraulic load. Moreover, the use of a mathematical model as an effective tool in decision making was demonstrated.  相似文献   