首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A thin fluorescent test layer, which is used in a practically mono-exponential bleaching regime, is employed to determine separately the excitation intensity and the fluorescence detection efficiency distributions in the field of view of a confocal fluorescence microscope. We demonstrate that once these distributions are known, it is possible to correct an image of a specimen for intensity variations which are caused by spatial nonuniformities of the illumination and the detection efficiency of the microscope. It is indicated that, provided a photophysically well-characterized fluorescent test layer is available, the method is potentially capable of quantifying the fluorescence intensities in an image of a specimen in terms of the fluorescence quantum yield, the absorption cross-section and the concentration of the fluorophore in the specimen.  相似文献   

2.
A method is presented for the standardization of images acquired with fluorescence microscopy, based on the knowledge of spatial distributions proportional to the microscope's absolute excitation intensity and fluorescence detection efficiency distributions over the image field. These distributions are determined using a thin fluorescent test layer, employed under practically mono-exponential photobleaching conditions. It is demonstrated that these distributions can be used for (i) the quantitative evaluation of differences between both the excitation intensity and the fluorescence detection efficiency of different fluorescence microscopes and (ii) the standardization of images acquired with different microscopes, permitting the deduction of quantitative relationships between images obtained under different imaging conditions.  相似文献   

3.
We propose an algorithmic technique for accelerating maximum likelihood (ML) algorithm for image reconstruction in fluorescence microscopy. This is made possible by integrating Biggs–Andrews (BA) method with ML approach. The results on widefield, confocal, and super‐resolution 4Pi microscopy reveal substantial improvement in the speed of 3D image reconstruction (the number of iterations has reduced by approximately one‐half). Moreover, the quality of reconstruction obtained using accelerated ML closely resembles with nonaccelerated ML method. The proposed technique is a step closer to realize real‐time reconstruction in 3D fluorescence microscopy. Microsc. Res. Tech. 78:331–335, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

4.
郑东 《现代仪器》2003,9(1):43-46
本文叙述荧光共振能量转移显微术及荧光寿命成像显微术的原理、方法及特点。同时介绍利用荧光共振能量转移显微术研究信号分子Rac蛋白在3T3成纤维细胞内的定位及活化过程,以及利用荧光共振能量转移—荧光寿命成像显微术研究转录因子CAATT/增强子结合蛋白α在小鼠垂体细胞内的二聚化现象。  相似文献   

5.
The imaging performance in single-photon (1-p) and two-photon (2-p) fluorescence microscopy is described. Both confocal and conventional systems are compared in terms of the three-dimensional (3-D) point spread function and the 3-D optical transfer function. Images of fluorescent sharp edges and layers are modelled, giving resolution in transverse and axial directions. A comparison of the imaging properties is also given for a 4Pi confocal system. Confocal 2-p 4Pi fluorescence microscopy gives the best axial resolution in the sense that its 3-D optical transfer function has the strongest response along the axial direction.  相似文献   

6.
We develop a multidimensional fluorescence imaging technique by implementing a wide-field time-gated fluorescence lifetime imaging into digital scanned laser light-sheet microscopy (FLIM-DSLM) to measure 3D fluorescence lifetime distribution in mesoscopic specimens with high resolution. This is achieved by acquiring a series of time-gated images at different relative time delays with respect of excitation pulses at different depths. The lifetime is determined for each voxel by iteratively fitting to single exponential decay. The performance of the developed system is evaluated with the measurements of a lifetime reference Rhodamine 6G solution and a subresolution fluorescent bead phantom. We also demonstrate the application performances of this system to ex vivo and in vivo imaging of Tg(kdrl:EGFP) transgenic zebrafish embryos, illustrating the lifetime differences between the GFP signal and the autofluorescence signal. The results show that FLIM-DSLM can be used for sample size up to a few millimetres and can be utilised as a powerful and robust method for biomedical research, for example as a readout of protein–protein interactions via Förster resonance energy transfer.  相似文献   

7.
Although single-photon fluorescence lifetime imaging microscopy (FLIM) is widely used to image molecular processes using a wide range of excitation wavelengths, the captured emission of this technique is confined to the visible spectrum. Here, we explore the feasibility of utilizing near-infrared (NIR) fluorescent molecular probes with emission >700 nm for FLIM of live cells. The confocal microscope is equipped with a 785 nm laser diode, a red-enhanced photomultiplier tube, and a time-correlated single photon counting card. We demonstrate that our system reports the lifetime distributions of NIR fluorescent dyes, cypate and DTTCI, in cells. In cells labelled separately or jointly with these dyes, NIR FLIM successfully distinguishes their lifetimes, providing a method to sort different cell populations. In addition, lifetime distributions of cells co-incubated with these dyes allow estimate of the dyes' relative concentrations in complex cellular microenvironments. With the heightened interest in fluorescence lifetime-based small animal imaging using NIR fluorophores, this technique further serves as a bridge between in vitro spectroscopic characterization of new fluorophore lifetimes and in vivo tissue imaging.  相似文献   

8.
Fluorescence polarization, particularly fluorescence anisotropy (FA) can be used to characterize the rotation dynamics and interactions of biomolecules. We report here fluorescence polarization microscopy based on a two-photon fluorescence microscope. Two-photon fluorescence excited by a linearly polarized fs laser beam was separated into components of parallel and perpendicular polarization and then recorded simultaneously by two detectors. From the images corresponding to different combinations of the polarization for the excitation and fluorescence photons, images of FA, or polarization difference, can be derived. It is demonstrated that FA microscopy is capable of probing rotational mobility of the fluorescent molecules and their interaction with the surroundings, but displays lower axial resolution than fluorescence intensity images. It is proved that the degraded axial resolution of FA imaging is intrinsic to the current experimental set-up. Artifacts in FA imaging of aligned molecules are also discussed.  相似文献   

9.
The improved resolution and sectioning capability of a confocal microscope make it an ideal instrument for extracting three-dimensional information especially from extended biological specimens. The imaging properties, also with finite detection pinholes are considered and a number of biological applications demonstrated.  相似文献   

10.
We study the feasibility of volume imaging from a few angular views/scans in a light sheet fluorescence microscopy. Two‐dimensional (2D) images (angular views) were acquired at an angular separation of 10° and volume images were constructed with merely 18, 9, and 6 views. We study the structural changes in a 5‐day old Zebrafish embryo labeled with Phalloidin TRITC that binds to F‐Actin of embryo cell. To collect the data, the specimen is rotated (for varying sampling angles Δθ) with respect to a fixed vertical axis passing through the volume‐of‐interest (yolk sac). In the proposed realization of selective plane illumination microscopy (SPIM) technique, the translation is completely avoided. Analysis shows rich structural information with marginal reduction in contrast. Comparison with the state‐of‐the‐art SPIM shows appreciable volume reconstruction (from an order less 2D scans) that may be good enough for rapid monitoring of macroscopic specimens. Microsc. Res. Tech. 79:455–458, 2016. © 2016 Wiley Periodicals, Inc.  相似文献   

11.
Fluorescence in situ hybridization on human metaphase chromosomes is detected by near-field scanning optical microscopy. This combination of cytochemical and scanning probe techniques enables the localization and identification of several fluorescently labelled genomic DNA fragments on a single chromosome with an unprecedented resolution. Three nucleic acid probes are used: pUC1. 77. p1–79 and the plasmid probe α-spectrin. The hybridization signals are very well resolved in the near-field fluorescence images, while the exact location of the probes can be correlated accurately with the chromosome topography as afforded by the shear force image.  相似文献   

12.
A commercially available atomic force microscopy and fluorescence microscope were installed and tested inside a custom-designed hyperbaric chamber to provide the capability to study the effects of hyperbaric gases on biological preparations, including cellular mechanism of oxidative stress. In this report, we list details of installing and testing atomic force microscopy and fluorescence microscopy inside a hyperbaric chamber. The pressure vessel was designed to accommodate a variety of imaging equipment and ensures full functionality at ambient and hyperbaric conditions (≤85 psi). Electrical, gas and fluid lines were installed to enable remote operation of instrumentation under hyperbaric conditions, and to maintain viable biological samples with gas-equilibrated superfusate and/or drugs. Systems were installed for vibration isolation and temperature regulation to maintain atomic force microscopy performance during compression and decompression. Results of atomic force microscopy testing demonstrate sub-nanometre resolution at hyperbaric pressure in dry scans and fluid scans, in both contact mode and tapping mode. Noise levels were less when measurements were taken under hyperbaric pressure with air, helium (He) and nitrogen (N(2) ). Atomic force microscopy and fluorescence microscopy measurements were made on a variety of living cell cultures exposed to hyperbaric gases (He, N(2) , O(2) , air). In summary, atomic force microscopy and fluorescence microscopy were installed and tested for use at hyperbaric pressures and enables the study of cellular and molecular effects of hyperbaric gases and pressure per se in biological preparations.  相似文献   

13.
Correlative microscopy is a collection of procedures that rely upon two or more imaging modalities to examine the same specimen. The imaging modalities employed should each provide unique information and the combined correlative data should be more information rich than that obtained by any of the imaging methods alone. Currently the most common form of correlative microscopy combines fluorescence and electron microscopy. While much of the correlative microscopy in the literature is derived from studies of model cell culture systems we have focused, primarily, on correlative microscopy in tissue samples. The use of tissue, particularly human tissue, may add constraints not encountered in cell culture systems. Ultrathin cryosections, typically used for immunoelectron microscopy, have served as the substrate for correlative fluorescence and electron microscopic immunolocalization in our studies. In this work, we have employed the bifunctional reporter FluoroNanogold. This labeling reagent contains both a fluorochrome and a gold-cluster compound and can be imaged by sequential fluorescence and electron microscopy. This approach permits the examination of exactly the same sub-cellular structures in both fluorescence and electron microscopy with a high level of spatial resolution.  相似文献   

14.
In the femtoliter observation volume of a two-photon microscope, multiple fluorophores can be present and complex photophysics can take place. Combined detection of the fluorescence emission spectra and lifetimes can provide deeper insight into specimen properties than these two imaging modalities taken separately. Therefore, we have developed a detection scheme based on a frequency-modulated multichannel photomultiplier, which measures simultaneously the spectrum and the lifetime of the emitted fluorescence. Experimentally, the efficiency of the frequency domain lifetime measurement was compared to a time domain set-up. The performance of this spectrally and lifetime-resolved microscope was evaluated on reference specimens and living cells labeled with three different stains targeting the membrane, the mitochondria, and the nucleus.  相似文献   

15.
Although confocal microscopes have considerably smaller contribution of out-of-focus light than widefield microscopes, the confocal images can still be enhanced mathematically if the optical and data acquisition effects are accounted for. For that, several deconvolution algorithms have been proposed. As a practical solution, maximum-likelihood algorithms with regularization have been used. However, the choice of regularization parameters is often unknown although it has considerable effect on the result of deconvolution process. The aims of this work were: to find good estimates of deconvolution parameters; and to develop an open source software package that would allow testing different deconvolution algorithms and that would be easy to use in practice. Here, Richardson-Lucy algorithm has been implemented together with the total variation regularization in an open source software package IOCBio Microscope. The influence of total variation regularization on deconvolution process is determined by one parameter. We derived a formula to estimate this regularization parameter automatically from the images as the algorithm progresses. To assess the effectiveness of this algorithm, synthetic images were composed on the basis of confocal images of rat cardiomyocytes. From the analysis of deconvolved results, we have determined under which conditions our estimation of total variation regularization parameter gives good results. The estimated total variation regularization parameter can be monitored during deconvolution process and used as a stopping criterion. An inverse relation between the optimal regularization parameter and the peak signal-to-noise ratio of an image is shown. Finally, we demonstrate the use of the developed software by deconvolving images of rat cardiomyocytes with stained mitochondria and sarcolemma obtained by confocal and widefield microscopes.  相似文献   

16.
The effects of fluorescence saturation on imaging in confocal microscopy have been studied. To include saturation it was necessary to deviate from the widely assumed linear relationship between the fluorescence and the illumination intensity. The lateral response for a point-like object, as well as the optical sectioning power, decreases depending on the degree of saturation. For very high illumination intensities the response for a saturated point object approached that of a conventional fluorescence microscope in which the fluorescence was not saturated. The decrease in the axial confocal response has been confirmed qualitatively by experiment.  相似文献   

17.
A method of direct visualization by correlative scanning electron microscopy (SEM) and fluorescence light microscopy of cell structures of tissue cultured cells grown on conductive glass slides is described. We show that by growing cells on indium–tin oxide (ITO)-coated glass slides, secondary electron (SE) and backscatter electron (BSE) images of uncoated cells can be obtained in high-vacuum SEM without charging artefacts. Interestingly, we observed that BSE imaging is influenced by both accelerating voltage and ITO coating thickness. By combining SE and BSE imaging with fluorescence light microscopy imaging, we were able to reveal detailed features of actin cytoskeletal and mitochondrial structures in mouse embryonic fibroblasts. We propose that the application of ITO glass as a substrate for cell culture can easily be extended and offers new opportunities for correlative light and electron microscopy studies of adherently growing cells.  相似文献   

18.
Epifluorescence, confocal and total internal reflection microscopy are the most widely used techniques for optical single‐molecule experiments. Employing these methods, we recorded the emission intensity of the same single molecule as a function of the excitation rate under otherwise identical experimental conditions. Evaluation of these data provides a quantitative comparison of the signal‐to‐background ratios that can be achieved for the three microscopic techniques.  相似文献   

19.
Thin, uniformly fluorescing reference layers can be used to characterize the imaging conditions in confocal, or more general, sectioning microscopy. Through-focus datasets of such layers obtained by standard microscope routines provide the basis for the approach. A set of parameters derived from these datasets is developed for defining a number of relevant sectioned imaging properties. The main characteristics of a particular imaging situation can then be summarized in a Sectioned Imaging Property-chart or SIPchart. We propose the use of such charts for the characterization of imaging properties in confocal and multiphoton microscopy. As such, they can be the basis for comparison of sectioned imaging condition characteristics, quality control, maintenance or reproduction of sectioned imaging conditions and other applications. Such charts could prove useful in documenting the more relevant properties of the instrumentation used in microscopy studies. The method carries the potential to provide the basis for a general characterization of sectioned imaging conditions as the layers employed can be characterized and fabricated to standard specifications. A limited number of such thin, uniformly fluorescing layers is available from our group for this purpose. Extension of the method to multiphoton microscopy is discussed.  相似文献   

20.
The bilateral scanning approach to confocal microscopy is characterized by the direct generation of the image on a two-dimensional (2-D) detector. This detector can be a photographic plate, a CCD detector or the human eye, the human eye permitting direct visualization of the confocal image. Unlike Nipkow-type systems, laser light sources can be used for excitation. A design called a carousel has been developed, in which the bilateral confocal scan capability can be added to an existing microscope so that rapid exchange and comparison between confocal and non-confocal imaging conditions is possible. The design permits independent adjustment of confocal sectioning properties with lateral resolutions better than, or, in the worst case equivalent to, those available in conventional microscopy. The carousel can be considered as a stationary optical path in which certain imaging conditions, such as confocality, are defined and operate on part of the imaging field. The action of the bilateral scan mirror then extends this image condition over the whole field. A number of optical arrangements for the carousel are presented which realize various forms of confocal fluorescence and reflection imaging, with point, multiple point or slit confocal detection arrangements. Through the addition of active elements to the carousel direct stereoscopic, ratio, time-resolved and other types of imaging can be achieved, with direct image formation on a CCD, eye or other 2-D detectors without the need to modify the host microscope. Depending on the photon flux available, these imaging modes can run in real-time or can use a cooled CCD at (very) low light level for image integration over an extended period.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号