首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Degradation of 4-nitrophenol in aqueous medium by electro-Fenton method   总被引:4,自引:0,他引:4  
The degradation of 4-nitrophenol by electro-Fenton (E-Fenton) method was carried out in batch recirculation mode. The effect of operating conditions such as electrical current, Fenton's reagent dosage, Fe(II) to H(2)O(2) molar ratio, and H(2)O(2) feeding time on the efficiency of E-Fenton process was investigated. It was found that E-Fenton method showed the synergetic effect on COD removal. The increase of Fenton's reagent dosage, Fe(II) to H(2)O(2) molar ratio, and the electrical current would lead to the increase of COD removal efficiency. Continuous addition of hydrogen peroxide was more effective than the addition of hydrogen peroxide in a single step and there existed an optimal H(2)O(2) feeding time for COD removal. The reaction system was modeled as a plug flow reactor (PFR) in series with a continuous stirred tank reactor (CSTR), and the pseudo-first order rate constant of COD removal was determined from the model based on the experimental data.  相似文献   

2.
Optimization of Fenton process for the treatment of landfill leachate   总被引:18,自引:0,他引:18  
The treatment of landfill leachate by Fenton process was carried out in a batch reactor. The effect of operating conditions such as reaction time, pH, H2O2 to Fe(II) molar ratio, Fenton's reagent dosage, initial COD strength, feeding mode, the type of polymer, and temperature on the efficacy of Fenton process was investigated. It is demonstrated that Fenton's reagent can effectively degrade leachate organics. Fenton process was so fast that it was complete in 30 min. The oxidation of organic materials in the leachate was pH dependent and the optimal pH was 2.5. The favorable H2O2 to Fe(II) molar ratio was 1.5, and organic removal increased as dosage increased at the favorable H2O2 to Fe(II) molar ratio. The efficacy of Fenton process was improved by adding Fenton's reagent in multiple steps than that in a single step. Furthermore, the stepwise addition of both hydrogen peroxide and ferrous iron was more effective than that of hydrogen peroxide only. Sludge settling characteristics were much improved with the addition of the proper polymer. Temperature gave a positive effect on organic removal.  相似文献   

3.
The treatment of landfill leachate by Fenton process was carried out in a continuous stirred tank reactor (CSTR). The effect of operating conditions such as reaction time, hydraulic retention time, pH, H(2)O(2) to Fe(II) molar ratio, Fenton's reagent dosage, initial COD strength, and temperature on the efficacy of Fenton process was investigated. It is demonstrated that Fenton's reagent can effectively degrade leachate organics. Fenton process reached the steady state after three times of hydraulic retention. The oxidation of organic materials in the leachate was pH dependent and the optimal pH was 2.5. The favorable H(2)O(2) to Fe(II) molar ratio was 3, and organic removal increased as dosage increased at the favorable H(2)O(2) to Fe(II) molar ratio. Temperature gave a positive effect on organic removal.  相似文献   

4.
The pre-oxidation of an extremely polluted pharmaceutical wastewater (chemical oxygen demand (COD) value of 362,000mg/l) using the Fenton's reagent has been systematically studied using an experimental design technique. The parameters influencing the COD removal of the wastewater, namely temperature, ferrous ion and hydrogen peroxide concentrations have been optimized to achieve a COD global reduction of 56.4%.The total range of the proposed experimental design, however, could not be tested because under some conditions (hydrogen peroxide concentration over 5M) the Fenton's reaction became violent and could not be controlled, probably due to the high exothermic effect associated with COD oxidation. For the tested conditions, the optimal values of hydrogen peroxide and ferrous ion concentration were 3 and 0.3M, respectively, whereas temperature only showed a mild positive effect on COD removal. In addition, during the first 10min of Fenton's reaction, more than 90% of the total COD removal can be achieved.Fenton's reaction has proved to be a feasible technique for the pre-oxidation of the wastewater under study, and can be considered a suitable pre-treatment for this type of wastewaters.  相似文献   

5.
Municipal landfill leachate, especially mature leachate, may disrupt the performance of moderately-sized municipal activated sludge wastewater treatment plants, and likewise tend to be recalcitrant to biological pretreatment. Recently, Fenton methods have been investigated for chemical treatment or pre-treatment of mature leachate. In this paper, the results of laboratory tests to determine the roles of oxidation and coagulation in reducing the organic content of mature leachate during Fenton treatment are presented. The efficiencies of chemical oxygen demand (COD) oxidation and coagulation were tested, and the ratio of COD removal by oxidation to that by coagulation was assessed, under various operating conditions. Low initial pH, appropriate relative and absolute Fenton reagent dosages, aeration, and stepwise addition of reagents increased COD removal by oxidation and the importance of oxidation relative to coagulation. Simultaneous aeration and stepwise reagent addition allowed comparable treatment without initial acidification pH, due to the generation of acidic organic intermediates and the continuous input of CO2. On the other hand, high COD oxidation efficiency and low ferrous dosage inhibited COD removal by coagulation. At significantly high oxidation efficiency, overall COD reduction decrease slightly due to low coagulation efficiency. Under the most favorable conditions (initial pH 3, molar ratio [H(2)O(2)]/[Fe2+]=3, [H2O2]=240 mM, and six dosing steps), 61% of the initial COD was removed, and the ratio of COD removal oxidation to coagulation was 0.75. Results highlighted the synergistic roles of oxidation and coagulation in Fenton treatment of mature leachate, and the role of oxidation in controlling the efficiency of removal of COD by coagulation.  相似文献   

6.
The treatment of leachate from landfills is a major disposal problem for municipal solid waste. The leachate is generally recalcitrant to be treated according to complicated characteristics and high color intensity resulting further threat for environment and human health. In this work, the designed thin gap annular photoreactor with 4-UV lamps in UV/H2O2 process was proposed to decolor and remove chemical oxygen demand (COD) from the landfill leachate for solving this environmental problem. Meanwhile, the operating parameters such as UV dosage, hydrogen peroxide concentration and leachate strength were evaluated. The landfill leachate treated with the maximum dosage of 4-UV lamps and 232.7 mM of hydrogen peroxide concentration achieved 72 and 65% of color and COD removal efficiencies in 300 min. As for less concentrated leachate of 20% strength, 91% of color and 87% of COD were removed within only 120 min. From the experimental results, the UV/H2O2 process in this work was an effective pre-treatment or treatment technology for landfill leachate.  相似文献   

7.
The oxidation of leachate coming from the composting of two organic wastes (wastewater sludge and organic fraction of municipal solid wastes) using the Fenton's reagent was studied using different ratios [Fe(2+)]/[COD](0) and maintaining a ratio [H(2)O(2)]/[COD](0) equal to 1. The optimal conditions for Fenton reaction were found at a ratio [Fe(2+)]/[COD](0) equal to 0.1. Both leachates were significantly oxidized under these conditions in terms of COD removal (77 and 75% for leachate from wastewater sludge composting and leachate from organic fraction of municipal solid wastes, respectively) and BOD(5) removal (90 and 98% for leachate from wastewater sludge composting and leachate from organic fraction of municipal solid wastes, respectively). Fenton's reagent was found to oxidize preferably biodegradable organic matter of leachate. In consequence, a decrease in the biodegradability of leachates was observed after Fenton treatment for both leachates. Nevertheless, Fenton reaction proved to be a feasible technique for the oxidation of the leachate under study, and it can be considered a suitable treatment for this type of wastewaters.  相似文献   

8.
Fenton's reagent is the result of reaction between hydrogen peroxide (H(2)O(2)) and ferrous iron (Fe(2+)), producing the hydroxyl radical (-*OH). The hydroxyl radical is a strong oxidant capable of oxidizing various organic compounds. The mechanism of oxidizing trichloroethylene (TCE) in groundwater and soil slurries with Fenton's reagent and the feasibility of injecting Fenton's reagent into a sandy aquifer were examined with bench-scale soil column and batch experiment studies. Under batch experimental conditions and low pH values ( approximately 3), Fenton's reagent was able to oxidize 93-100% (by weight) of dissolved TCE in groundwater and 98-102% (by weight) of TCE in soil slurries. Hydrogen peroxide decomposed rapidly in the test soil medium in both batch and column experiments. Due to competition between H(2)O(2) and TCE for hydroxyl radicals in the aqueous solutions and soil slurries, the presence of TCE significantly decreased the degradation rate of H(2)O(2) and was preferentially degraded by hydroxyl radicals. In the batch experiments, Fenton's reagent was able to completely dechlorinate the aqueous-phase TCE with and without the presence of soil and no VOC intermediates or by-products were found in the oxidation process. In the soil column experiments, it was found that application of high concentrations of H(2)O(2) with addition of no Fe(2+) generated large quantities of gas in a short period of time, sparging about 70% of the dissolved TCE into the gaseous phase with little or no detectable oxidation taking place. Fenton's reagent completely oxidized the dissolved phase TCE in the soil column experiment when TCE and Fenton's regent were simultaneously fed into the column. The results of this study showed that the feasibility of injecting Fenton's reagent or H(2)O(2) as a Fenton-type oxidant into the subsurface is highly dependent on the soil oxidant demand (SOD), presence of sufficient quantities of ferrous iron in the application area, and the proximity of the injection area to the zone of high aqueous concentration of the target contaminant. Also, it was found that in situ application of H(2)O(2) could have a gas-sparging effect on the dissolved VOC in groundwater, requiring careful attention to the remedial system design.  相似文献   

9.
Advanced oxidation processes (AOPs), namely photo-Fenton, Fenton-like, Fenton and UV/H(2)O(2), have been investigated in the removal of organic matter and colour from landfill leachates. The leachate was characterised by high COD, low biodegradability and intense dark colour. Evaluation of COD removal as a function of the operation variables (H(2)O(2), Fe(2+), Cu(2+), UV) led to results that ranged between 30% and 77% and it was observed that the removal efficiencies decreased in the order: photo-Fenton>Fenton-like>Fenton>UV/H(2)O(2)>UV. Thus, a detailed experimental analysis was carried out to analyse the effect of the hydrogen peroxide and iron concentrations and the number of reagent additions in the photo-Fenton process, observing that: (i) the COD removal ranged from 49% to 78% depending on the H(2)O(2) dose, (ii) the total amount of organic matter removed was increased by adding the reagent in multiple steps (86%), (iii) iron concentration corresponding to a Fe(2+)/COD mass ratio=0.33 was found to be the most favourable and, (iv) after a neutralization step, the colour and residual concentrations of iron and H(2)O(2) were practically negligible in the final leachate solution.  相似文献   

10.
The effectiveness of the Fenton's reagent (H(2)O(2)/Fe(2+)) in the treatment of carpet dyeing wastewater was investigated under different operational conditions, namely, H(2)O(2) and FeSO(4) concentrations, initial pH and temperature. Up to 95% COD removal efficiency was attained using 5.5 g/l FeSO(4) and 385 g/l H(2)O(2) at a pH of 3, temperature of 50 degrees C. The H(2)O(2)/Fe(2+) ratio (g/g) was found to be between 95 and 290 for maximum COD removal. It was noteworthy that, keeping H(2)O(2)/Fe(2+) ratio constant within the range of 95-290, it became possible to decrease FeSO(4) concentration to 1.1 g/l and H(2)O(2) concentration to 96.3 g/l, still achieving nearly the same COD removal efficiency. The relative efficiencies of Fenton's oxidation and coagulation stages revealed that Fenton's coagulation removed organic compounds which were not removed by Fenton's oxidation, indicating that the Fenton's coagulation acted as a polishing step.  相似文献   

11.
This study examines how Fenton's reagent (Fe2+ and H2O2) decomposed dichlorvos insecticide. Results showed that dichlorvos decomposed in a two-stage reaction. The first stage is a Fe2+/H2O2 reaction in which dichlorvos swiftly decomposed. In the second stage, dichlorvos decomposed somewhat less rapidly, and it is a Fe3+/H2O2 reaction. The detection of ferrous ions also supports the theory of the two-stage reaction for the dichlorvos oxidation with Fenton's reagent. The dissolved oxygen of the solution decreased rapidly in the first stage reaction, but it slowly increased in the second stage with a zero-order kinetics. The Fenton system decomposed dichlorvos most rapidly when the initial pH in the solution is 3-4. In addition, increasing the concentration of hydrogen peroxide or ferrous ions can enhance the decomposition of dichlorvos. Consequently, the relationship of rate constant (kobs), [H2O2] and [Fe2+] at initial pH 3 is determined as kobs = 2.67 x 10(4)[H2O2]0.7[Fe2+]1.2.  相似文献   

12.
The chemical oxidation of the wastewaters generated during storage of table olives in NaCl brines, prior to their manufacturing process, was studied. Ozone alone produced COD removals in the range 14-23%, and a higher average removal of 73% of the aromatic compounds. The additional presence of hydrogen peroxide and UV radiation increased these values to 39% for COD and 86% for aromatics. However, UV radiation alone only gave a removal of 9% for COD and 27% for aromatics, and the additional presence of 0.5M H(2)O(2) led to 13% for COD and 38% for aromatics, respectively. The Fenton's reagent oxidation achieved a COD removal of 24% for the higher concentrations of Fe(2+) and H(2)O(2). The most effective process was the combination O(3)/UV/H(2)O(2) with total removals of 65 and 92% for the COD and aromatics, respectively. The aerobic treatment of these effluents gave a 66% removal regardless of the initial biomass concentration used, and a rate constant of 0.19 per day was obtained for the process by using the Contois model. Finally, the aerobic treatment of the wastewaters previously ozonated alone, and ozonated with UV radiation, gave increases in the COD removal and a final rate constant of 0.44 per day. The enhancements were due to the chemical oxidations, these procedures being suitable technologies as pre-treatments to subsequent biological processes for the purification of these residues.  相似文献   

13.
Simple measurements of H2O2 concentration or CO2 evolution were used to evaluate the effectiveness of the use of Fenton's reagent to mineralize organic compounds in water and soil contaminated by crude petroleum. This methodology is suitable for application in small treatment and remediation facilities. Reagent concentrations of H2O2 and Fe(2+) were found to influence the reaction time and temperature, as well as the degree of mineralization and biodegradability of the sample contaminants. Some H2O2/Fe(2+) combinations (H2O2 greater than 10% and Fe(2+) greater than 50mM) resulted in a strong exothermic reaction, which causes peroxide degradation and violent gas liberation. Up to 75% TOC removal efficiency was attained in water and 70% in soil when high H2O2 (20%) and low Fe(2+) (1mM) concentrations were used. Besides increasing the degree of mineralization, the Fenton's reaction enhances the biodegradability of petroleum compounds (BOD5/COD ratios) by a factor of up to 3.8 for contaminated samples of both water and soil. Our experiments showed that low reagent concentrations (1% H2O2 and 1mM Fe(2+)) were sufficient to start the degradation process, which could be continued using microorganisms. This leads to a decrease in reagent costs in the treatment of petroleum-contaminated water and soil samples. The simple measurements of H2O2 concentration or CO2 evolution were effective to evaluate the Fenton's reaction efficiency.  相似文献   

14.
The aim of this work was to evaluate the efficiency of three chemical oxidation processes for increasing the biodegradability of aqueous diethanolamine solutions (aqueous DEA solutions), to be used as pre-treatments before a biological process. The raw aqueous DEA solution, sourced from a sour gas sweetening plant at a Mexican oil refinery, was first characterized by standardized physico-chemical methods. Then experiments were conducted on diluted aqueous DEA solutions to test the effects of Fenton's reagent, ozone and ozone-hydrogen peroxide on the removal of some physicochemical parameters of these solutions. Lastly, biodegradability tests based on Dissolved Organic Carbon Die Away OECD301-A, were carried out on a dilution of the raw aqueous DEA solution and on the treated aqueous DEA solutions, produced by applying the best experimental conditions determined during the aforementioned oxidation tests. Experimental results showed that for aqueous DEA solutions treated with Fenton's reagent, the best degradation rate (70%) was obtained at pH 2.8, with Fe(2+) and H(2)O(2) at doses of 1000 and 10,000 mg/L respectively. In the ozone process, the best degradation (60%) was observed in aqueous DEA solution (100 mg COD/L), using 100 mg O(3)/L at pH 5. In the ozone-hydrogen peroxide process, no COD or DOC removals were observed. The diluted spent diethanolamine solution showed its greatest increase in biodegradability after a reaction period of 28 days when treated with Fenton's reagent, but after only 15 days in the case of ozonation.  相似文献   

15.
Aqueous oxidation treatment of COD and color in landfill leachate with the combination of hydrogen peroxide and ferrous ion, Fenton reagent, has been studied. The effect of variables such as concentration of both reactants and pH has been investigated. Best concentrations seem to be 0.6 and 3.0 mol/L for H2O2 and Fe2+ ion, respectively. The other important variable, pH of landfill leachate should be near 7. From the experimental results can be known the determined process was the generation of hydroxyl radicals involving in advanced oxidation. Oxidation rates are even higher than those of other advanced oxidation systems involving ozone, UV radiation, and hydrogen peroxide.  相似文献   

16.
Pulp mill effluent containing toxic chemicals was treated by different advanced oxidation processes (AOPs) consisting of treatments by hydrogen peroxide, Fenton's reagent (H2O2/Fe2+), UV, UV/H2O2, photo-Fenton (UV/H2O2/Fe2+), ozonation and peroxone (ozone/H2O2) in laboratory-scale reactors for color, total organic carbon (TOC) and adsorbable organic halogens (AOX) removals from the pulp mill effluent. Effects of some operating parameters such as the initial pH, oxidant and catalyst concentrations on TOC, color, AOX removals were investigated. Almost every method used resulted in some degree of color removal from the pulp mill effluent. However, the Fenton's reagent utilizing H2O2/Fe2+ resulted in the highest color, TOC and AOX removals under acidic conditions when compared with the other AOPs tested. Approximately, 88% TOC, 85% color and 89% AOX removals were obtained by the Fenton's reagent at pH 5 within 30 min. Photo-Fenton process yielded comparable TOC (85%), color (82%) and AOX (93%) removals within 5 min due to oxidations by UV light in addition to the Fenton's reagent. Fast oxidation reactions by the photo-Fenton treatment makes this approach more favorable as compared to the others used.  相似文献   

17.
Application of Fenton oxidation to cosmetic wastewaters treatment   总被引:1,自引:0,他引:1  
The removal of organic matter (TOC and COD) from a cosmetic wastewater by Fenton oxidation treatment has been evaluated. The operating conditions (temperature as well as ferrous ion and hydrogen peroxide dosage) have been optimized. Working at an initial pH equal to 3.0, a Fe(2+) concentration of 200 mg/L and a H(2)O(2) concentration to COD initial weight ratio corresponding to the theoretical stoichiometric value (2.12), a TOC conversion higher than 45% at 25 degrees C and 60% at 50 degrees C was achieved. Application of the Fenton oxidation process allows to reach the COD regional limit for industrial wastewaters discharges to the municipal sewer system. A simple kinetic analysis based on TOC was carried out. A second-order equation describes well the overall kinetics of the process within a wide TOC conversion range covering up to the 80-90% of the maximum achievable conversion.  相似文献   

18.
An advanced oxidation process, UV/H2O2, was applied for decolorization of a di-azo dye (acid black 1). The effects of operating parameters such as hydrogen peroxide dosage, UV dosage and initial dye concentration, on decolorization have been evaluated. The acid black 1 solution was completely decolorized under optimal hydrogen peroxide dosage of 21.24 mmol/l and UV dosage of 1400 W/l in less than 1.2 min. The decolorization rate followed pseudo-first order kinetics with respect to the dye concentration. The rate increased linearly with volumetric UV dosage and nonlinearly with increasing initial hydrogen peroxide concentration. It has been found that the degradation rate increased until an optimum of hydrogen peroxide dosage, beyond which the reagent exerted an inhibitory effect. For real case application, an operation parameter plot of rate constant was developed. To evaluate the electric power and hydrogen peroxide consumption by UV/H2O2 reactor, 90% color removal was set as criteria to find the balance between both factors.  相似文献   

19.
The aim of our research was to determine appropriate treatment technique for effective treatment of heavily polluted tannery landfill leachate. We have accomplished several treatment experiments: (i) aerobic biological treatment, (ii) air stripping at various pH, (iii) adsorption to activated carbon, (iv) coagulation-flocculation and (v) advanced oxidation process with Fe(2+)/H(2)O(2). Efficiency of each procedure was monitored by chemical analysis and changes in biodegradability and acute toxicity were also evaluated (Vibrio fischeri and Daphnia magna). Biological treatment of raw leachate was effective only for very diluted leachate (up to 6Vol.%). It has been confirmed that air stripping at pH 11.0 effectively removed volatile organics and ammonia for 33% and 84%, respectively and contributed to lower toxicity of the leachate. Fenton's oxidation was the most effective among all used treatment procedures. COD removal reached 86%, biodegradability has been increased and toxicity reduced. Adsorption to activated carbon increased BOD(5)/COD ratio from 0.18 to 0.56 and it removed 40% of organics. Coagulation and flocculation procedures with FeCl(3) were also very effective. At lowered pH and added flocculant treatment efficiency reached 50%. But no method alone was effective enough to meet effluent limits for release into local surface waters. Future work was focused on the study of different promising treatment schemes, especially combination of Fenton's oxidation and biological treatment.  相似文献   

20.
The applicability of Fenton's oxidation to improve the biodegradability of a pharmaceutical wastewater to be treated biologically was investigated. The wastewater was originated from a factory producing a variety of pharmaceutical chemicals. Treatability studies were conducted under laboratory conditions with all chemicals (having COD varying from 900 to 7000 mg/L) produced in the factory in order to determine the operational conditions to utilize in the full-scale treatment plant. Optimum pH was determined as 3.5 and 7.0 for the first (oxidation) and second stage (coagulation) of the Fenton process, respectively. For all chemicals, COD removal efficiency was highest when the molar ratio of H(2)O(2)/Fe(2+) was 150-250. At H(2)O(2)/Fe(2+) ratio of 155, 0.3M H(2)O(2) and 0.002 M Fe(2+), provided 45-65% COD removal. The wastewater treatment plant that employs Fenton oxidation followed by aerobic degradation in sequencing batch reactors (SBR), built after these treatability studies provided an overall COD removal efficiency of 98%, and compliance with the discharge limits. The efficiency of the Fenton's oxidation was around 45-50% and the efficiency in the SBR system which has two reactors each having a volume of 8m(3) and operated with a total cycle time of 1 day, was around 98%, regarding the COD removal.  相似文献   