首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This work presents a thorough fractionation of COD in raw sewage, followed by pilot plant coagulation tests with low-dosage lime (pH 9). Through a physical separation (sieving and crossflow filtration) total COD in the raw sewage was partitioned among eight size fractions in the range of 150-0.02 microm. In addition, respirometric tests were performed to measure the biodegradability of the different size fractions. More than 60% of COD was associated with settleable and supracolloidal particles (size > 1 microm), which are characterised by slow biodegradability. Coagulation with lime increased COD removal efficiencies in the primary treatment from typical 30-35%, up to 65-70%, suggesting that lime may induce the almost complete removal of the slowly settling, slowly biodegradable supracolloidal particles in the primary treatment. On the basis of these results a non-conventional sewage treatment scheme is proposed, considering that there is plenty of space for improving primary treatment efficiency through sewage coagulation. Higher primary treatment efficiency may present several advantages, including lower aeration energy in the subsequent biological unit and higher energy recovery from sludge digestion.  相似文献   

2.
The effect of moving bed biofilm reactor (MBBR) loading rate on membrane fouling rate was studied in two parallel units combining MBBR and membrane reactor. Hollow fiber membranes with molecular weight cut-off of 30 kD were used. The HRTs of the MBBRs varied from 45 min to 4 h and the COD loading rates ranged from 4.1 to 26.6 g COD m(-2) d(-1). The trans-membrane pressure (TMP) was very sensitive to fluxes for the used membranes and the experiments were carried out at relatively low fluxes (3.3-5.6 l m(-2) h(-1)). Beside the test with the highest flux, there were no consistent differences in fouling rate between the low- and high-rate reactors. Also, the removal efficiencies were quite similar in both systems. The average COD removal efficiencies in the total process were 87% at 3-4 h HRT and 83% at 0.75-1 h HRT. At high loading rates, there was a shift in particle size distribution towards smaller particles in the MBBR effluents. However, 79-81% of the COD was in particles that were separated by membranes, explaining the relatively small differences in the removal efficiencies at different loading rates. The COD fractionation also indicated that the choice of membrane pore size within the range of 30 kD to 0.1 microm has very small effect on the COD removal in the MBBR/membrane process, especially with low-rate MBBRs.  相似文献   

3.
Aerobic granular sludge was successfully cultivated in a lab-scale SBR-system treating malting wastewater with a high content of particulate organic matter (0.9 gTSS/L). At an organic loading rate (CODtotal) of 3.4 kg/(m3 x d) an average removal efficiency of 50% in CODtotal and 80% in CODdissolved was achieved. Fractionation of the COD by means of particle size showed that particles with a diameter less than 25-50 microm could be removed at 80% efficiency, whereas particles bigger than 50 microm were only removed at 40% efficiency. Tracer experiments revealed a dense sessile protozoa population covering the granules. The protozoa appeared to be responsible for primary particle uptake from the wastewater.  相似文献   

4.
The treatment of winery wastewater was performed at full-scale applying a two-stage fixed bed biofilm reactor (FBBR) system for the discharge in the sewerage. The results of the first year of operation at the full-scale plant are presented. Values of removed organic loads and effluent concentrations were interpreted on the basis of the COD fractionation of influent wastewater assessed through respirometric tests. The average removal efficiency of total COD was 91 %. It was not possible to reach an higher efficiency because of the unbiodegradable soluble fraction of COD (about 10% of total COD on average during the whole year), that cannot be removed by biological process or settling. Due to the high empty space offered by the plastic carriers, FBBRs did not require backwashing during the seasonal operationing period of the plant (September-March). In comparison with other treatment systems the FBBR configuration allows one to ensure a simple management, to obtain high efficiency also in the case of higher fluctuations of flow and loads and to guarantee a good settleability of the sludge, without bulking problems.  相似文献   

5.
Particle size distribution (PSD) via sequential filtration/ultrafiltration was used as the tool for COD fractionation and colour profiling of textile wastewaters before and after treatment. Profiles prior to treatment suggested PSD-based COD fingerprints characteristic for the influents. Treatment efficiencies were determined via comparing the profiles of the effluents from chemical- and biological-treatment to those of the corresponding influents. COD fingerprints of the wastewaters from the textile plants, applying different treatment alternatives, were different especially at the upper size range; yet profiles after treatment were similar, with the soluble fraction (< 2 nm) being almost the only apparent one. Half of the overall COD-removal via chemical treatment was at the particulate- and upper colloidal-ranges, revealing that this alternative was effective at higher ranges, but not at the soluble fraction. In contrast, biological treatment was effective at both ends of size distribution, with total removal at the particulate range and 50% elimination at the soluble portion. Overall colour content and PSD-based colour profiles of the influents were also different. Chemical treatment was successful in removing colour originating from the entire colloidal range, but was not efficient at the soluble fraction. Conversely, colour removal efficiency of biological treatment was moderate throughout the entire size spectrum.  相似文献   

6.
The effect of ozone based oxidation on removing recalcitrant organic matter (ROM) and enhancing the biodegradability of alkaline bleach plant effluent was investigated. A bubble column ozonation tower was used in the study. The experiments were carried out at different temperatures (20 degrees C and 60 degrees C) and pH (9 and 11), with a number of biological and chemical parameters being monitored including BOD5, COD, TC, pH, color, and molecular weight distribution of organics (nominal cut off of 1,000 Da). Biodegradability of the effluent was determined based on BOD5/COD of the wastewater throughout the process. For all the experiments, ozonation enhanced the biodegradability of the effluent by 30-40%, which was associated with noticeable removal of ROM including high molecular weight (HMW) and color-causing organics by about 30% and 60%, respectively. While the biodegradability of HMW fraction increased by about 50%, there was no biodegradability improvement for low molecular weight (LMW) portion, which was originally readily biodegradable (with BOD5/COD of about 0.5). Statistical analysis of variance (ANOVA) revealed neither pH nor temperature played significant role on the ozonation process at 95% confidence level.  相似文献   

7.
This study was conducted to evaluate the treatability of OMW (olive mill wastewater) with sewage and sewage sludge, which could supplement nutrients and microbes required for OMW treatment and reduce its possible toxicity. The amount of OMW added to an aeration tank was based on the loading difference between the designed and actual COD loads, while the amount added to anaerobic digestion for energy recovery was determined by CH4 production. The COD removal efficiencies were 70-85% for both systems. Compost of OMW with dried sewage sludge also showed a similar temperature profile without OMW addition. This strongly suggested that OMW can be treated at a sewage plant without pretreatment and the treated effluent can be reused in irrigation for an arid region.  相似文献   

8.
9.
A comparison of two different medium scale MBRs (ultrafiltration and microfiltration) using respirometric methods has been achieved. The ultrafiltration membrane plant (0.034 microm pore size) maintained recirculation sludge flow at seven times the influent flow, and membranes were backwashed every 5 min and chemically cleaned weekly. The microfiltration membrane plant (0.4 microm pore size) maintained recirculation sludge flow at four times the influent flow, membrane-relax was applied after the production phase and membranes were chemically cleaned in the event of high trans-membrane pressure. Both technologies showed a similar performance with regard to heterotrophic kinetic and stoichiometric parameters and organic matter effluent concentrations. The influent was characterized by means of its COD fractions and the average removal percentages for COD concentrations were around 97% for both plants in spite of influent COD fluctuation, temperature variations and sludge retention time (SRT) evolution. Both SRT evolution and temperature affect the heterotrophic yield (Y(H)) and the decay coefficient (bH) in the same range for both plants. Y(H) values of over 0.8 mg COD/mg COD were obtained during the unsteady periods, while under steady state conditions these values fell to less than 0.4 mg COD/mg COD. bH by contrast reached values of less than 0.05 d(-1).  相似文献   

10.
To reduce the residual organic matter and phosphorus contained in secondary effluent, a biofiltration system combined with electrocoagulation using bipolar iron electrodes was evaluated as a supplementary treatment to existing small-community sewage treatment. Based on the results of batch tests, bipolar electrocoagulation (BEC) was found to be more effective on phosphorus removal than monopolar electrocoagulation (MEC) but energy consumption was less in monopolar electrocoagulation. Optimum conditions of BEC to treat the secondary effluent were current density 15 A/m2, electrode spacing 1 cm and pH < 8. The removals of COD(Cr) and phosphorus by biofiltration system without BEC were 69.1% and 9.6%, respectively. However, biofiltration system combined with BEC showed 76.6-83.7% and 70.7-93.0% removal for COD(Cr) and phosphorus respectively. Extraordinary increase in phosphorus could be achieved by introducing electrocoagulation to biofiltration, and BEC/biofiltration system was evaluated to be applicable to existing small-community sewage treatment plants as a supplementary process.  相似文献   

11.
The return flows of reject water from sewage sludge dewatering alter the activated sludge process in a conventional WWTP and increase TN concentration in the final effluent from WWTP. The objective of the investigation carried out was to consider the application of multistage treatment wetland (MTW) for the treatment of reject water from sewage sludge dewatering in a centrifuge (RWC). This paper aims to present the design and performance of each stage of the treatment as well as the efficiency of total MTW. The full scale pilot plant for RWC, consisting of two vertical flow beds (SS VF) working in series, followed by an horizontal flow bed (SS HF), was built in 2008. The applied configuration ensured a very high removal efficiency of principal pollutant (COD - 76.0% and NH4+-N - 93.6%). In the investigated facilities, the SS VF beds ensured an effective removal of nitrogen compounds, especially NH4+-N, whereas the decomposition of hardly degradable Org-N and COD took place in SS HF. This research illustrates that the MTW could be successfully applied for the treatment of RWC.  相似文献   

12.
Membranes can be installed in the clarifier (or aeration tank) of an existing activated sludge plant to enhance the biomass separation function of the system, thereby effectively overcoming any operating constraints associated with sludge settleability. The resulting upgraded plant can be operated at high biomass concentrations (10–20 gMLSS/L), leading to an increase in its treatment capacity. The membranes also ensure a treated water consistently free of suspended solids and a superior disinfection performance. The system offers an enhanced operating flexibility, and allows to operate at high sludge ages leading to a low excess sludge production.Such an immersed membrane activated sludge process (BIOSEP®) has been developed and applied to the treatment of raw sewage. When treating screened raw sewage with this process, with a sludge concentration of 15 gMLSS/L and a volumetric loading of 1.2 kgCOD/m3/d, a 96% COD reduction and a 95% Total Kjeldahl Nitrogen (TKN) reduction have been obtained. The disinfection performance of the system was over 6 Log removal for fecal coliforms. The resulting production of sludge was 0.20 kgMLSS/kgCOD.Two desk case studies are given for 900 m3/day upgraded plants. In one case, the primary objective was to increase the treatment efficiency and develop nutrient removal for the original plant, while in the other case the primary objective was to increase the capacity of the original 460 m3/day plant.  相似文献   

13.
Laboratory batch experiments were conducted at 20 degrees C to investigate the potential of primary sludge fermentation for the generation of readily biodegradable substrate and to evaluate the effect of fermentation products on mass balance for organic carbon, nitrogen and phosphorus, emphasizing COD fractionation. Fermentation converted between 18 to 30% of the initial volatile suspended solids in the sludge into soluble biodegradable COD. The volatile fatty fraction of the soluble COD was approximately 85% after the fermentation process. The average volatile fatty acid composition in fermentation involved 50% acetic acid, 33% propionic acid, 9% butyric acid and 8% valeric acid, indicating that the most important volatile fatty acid obtained during the biological fermentation process was acetate with more than half of total VFA concentration, which is one of the most important carbon sources for denitrification and biological nutrient removal processes. The recoverable fraction of the fermented sludge supernatant could potentially increase the readily biodegradable COD content of the primary effluent by 5%, together with a potential increase of the soluble nitrogen and phosphorus content by 2%.  相似文献   

14.
A Discfilter with 10 and 18 microm filter openings, respectively, was placed in parallel to a flotation plant for separation of biological flocs from a post-denitrifying Kaldnes Moving Bed Process, the last treatment step at the municipal wastewater treatment plant at Sj?unda, Malm?, Sweden. The effluent concentrations from the 10 and 18 microm filter were 2-5 and 2-8 mg SS L(-1), respectively, which is comparable to, or better than, the flotation plant. Comparison with experiences from activated sludge plants shows that the Discfilter works especially well after the Kaldnes process. Particle size distribution (PSD) studies show that particles larger than the filter openings of 10 and 18 microm are separated with approximately 90% efficiency, whereas most of the smaller particles pass the filter. This fact indicates that the major particle separation mechanism is physical blocking. These findings point to the possibility of improving the prediction of the separation efficiency by combining measurements of turbidity and suspended solids with particle size analysis.  相似文献   

15.
Irrigation with reclaimed water is becoming a practical alternative to conventional irrigation in semi-arid areas of the Mediterranean like Spain, but it requires a reliable treatment process to provide a safe water supply. Helminth eggs are one of the main concerns for the safe use of reclaimed water, as they can survive adverse environmental conditions and they are highly infective. Spanish water quality criteria and International guidelines set a limit of 0.1 eggs/l for water uses with unrestricted human exposure. Two microscreening processes have been tested to determine their potential for helminth eggs removal, after a conventional physic-chemical reclamation process. Hydrotech Drum and Discfilters, provided with 10 microm pore size filter cloth, were tested to determine their efficiency for helminth eggs straining. An experimental test was conducted using 20 microm spherical latex particles, as surrogates for helminth eggs, to test the removal efficiency of a small full-scale drumfilter. In a subsequent laboratory test, actual Trichuris suis eggs were strained using a 10 microm pore size filter cloth from a discfilter. Results from both tests indicate that drum and discfilters are able to achieve 99% removal efficiency for spherical latex particles and a complete removal for helminth eggs in reclaimed water.  相似文献   

16.
Two high-rate, anaerobic/aerobic units were used to treat the sewage of the Institut Agronomique st Vétérinaire Hassan II (Morocco) campus in a 1,100 m2-plant designed for 1,500 e.p. and receiving 63 m3 per day. The anaerobic pre-treatment consisted of a two-step up-flow anaerobic reactor (TSUAR) comprising two reactors and one external settler all in series. The aerobic line, or post-treatment, consisted of a high-rate algal pond (HRAP) and one maturation pond in series. The system totalized a hydraulic retention time (HRT) of 9 days. A gravel filter (GF) was constructed behind the TSUAR to trap low-density particles. The TSUAR removed 80% of COD and 90% of SS within 48 h. Solids retention time in the reactors averaged 32 d with a specific sludge production of 0.28 g SS g(-1) COD removed. Almost 93% of the sludge evacuated from the settler was stabilized. Specific biogas production from both reactors was 0.25m3 kg(-1) COD removed. Used in this configuration, the HRAP lost its BOD removal activity and increased its nutrients and pathogens removal capabilities (tertiary treatment). Results showed that 85% of total nitrogen and 48% of total phosphorus were removed by the HRAP. Land area requirement of this combination was less than 1 m2 per capita and filtered final effluent was of excellent quality (COD, 82 mg/l; TKN, 8.3 mg/l; total P, 2.7 mg/l, faecal coliforms, 2.4 10(3)/100 ml and zero helminths eggs).  相似文献   

17.
The extension of the Nijmegen wastewater treatment plant for full nitrogen and phosphorus removal is enormously reduced by introducing an innovative energy interaction with an incineration plant. A reduction of the investment costs of 30-40% has been reached. Heating up a part of the primary sedimentation overflow leads to a constant process temperature of 20-25 degrees C and an advanced biological phosphorus and COD removal.  相似文献   

18.
In this study, feasibility of membrane separation for the removal of indigenous noroviruses (NVs) is evaluated. The indigenous NV gene was never detected from ultrafiltration (UF) permeates of sewage sludge and treated wastewater. Indigenous NV gene was also not detected from permeates of sewage sludge and treated wastewater by microfiltration (MF) with a pore size of 0.1 microm (MF0.1). Even though the pore size of MF (0.1 microm) was much larger than the diameter of virus particle (approximately 30-40nm), more than 4-log10 reduction value (LRV) at maximum was achieved by membrane separation with MF0.1. NV genes were often detected from permeates of sewage sludge and treated wastewater by MF with a pore size of 0.45 microm (MF0.45), although the maximum log10 reduction values were more than 3.59 for sewage sludge and more than 2.90 for treated wastewater. It is important to verify factors determining the removal efficiency of viruses with MF membranes.  相似文献   

19.
The effect of organic loading, season and plant species on the treatment of fish farm effluent was tested using three-year old mesocosm wetland systems. During one year, nine 1 m2 mesocosms (horizontal subsurface flow), located in a controlled greenhouse environment, were fed with a reconstituted fish farm effluent containing a high fraction of soluble components (1,600 microS/cm and in mg/L: 230 +/- 80 COD, 179 +/- 60 sCOD, 100 +/- 40 TSS, 37 +/- 7 TKN, 14 +/- 2 TP). Combinations of three hydraulic loading rates (30, 60 and 90 L.m(-2) d(-1)) and two plant species (Phragmites australis, Typha angustifolia) and an unplanted control were tested for treatment performance and hydraulic behaviour. Loadings higher than 15 g COD m(-2) d(-1) resulted in a net decrease of hydraulic performances (generation of short circuiting) coupled with low TKN removal. Maximal TKN removal rates (summer: 1.2, winter: 0.6 g.m(-2) d(-1)) were reached in planted units. In all mesocosms, phosphorus was removed during summer (maximal removal rate: 0.3 g TP m(-2) d(-1)) and was released in winter (release rate = approximately half of summer removal rate). This study confirmed that constructed wetlands are susceptible to clogging when treating anaerobic storage tank supernatant rich in highly biodegradable compounds. Contributions of plants to hydraulic efficiency were mainly observed in summer, associated with high evapotranspiration rates. Both plant species gave a similar removal efficiency for all pollutants.  相似文献   

20.
The present study aimed mainly for the development of a wastewater treatment system incorporating enhanced primary treatment, anaerobic digestion of coagulated organics, biofilm aerobic process for the removal of soluble organics and disinfection of treated water. An attempt was also made to study the reuse potential of treated water for irrigation and use of digested sludge as soil conditioner by growing marigold plants. Ferric chloride dose of 30 mg/l was found to be the optimum dose for enhanced primary treatment with removals of COD and BOD to the extent of 60% and 77%, respectively. Efficient anaerobic digestion of ferric coagulated sludge was performed at 7 days hydraulic retention time (HRT). Upflow aerobic fixed film reactor (UAFFR) was very efficient in removals of COD/BOD in the organic loading rate (OLR) range of 0.25 to 3 kg COD/m(3)/day with COD and BOD removals in the range 65-90 and 82-96, respectively. Photo-oxidation followed by disinfection saved 50% of chlorine dose required for disinfection of treated effluent and treated water was found to be suitable for irrigation. The result also indicated that anaerobically digested sludge may be an excellent soil conditioner. From the results of this study, it is possible to conclude that the developed wastewater treatment system is an attractive ecologically sustainable alternative for sewage treatment from institutional/industrial/residential campuses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号