首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A calibration apparatus for contact surface thermometers was developed. Temperature of the upper surface of a copper cube of the calibration apparatus was used as reference surface temperature, which was estimated at around \(50\,{^{\circ }}\hbox {C}\), \(100\,{^{\circ }}\hbox {C}\), and \(150\,{^{\circ }}\hbox {C}\) by not only two conventional industrial platinum resistance thermometers (IPRTs) but also five small-sized platinum resistance thermometers (SSPRTs) calibrated based on the International Temperature Scale of 1990 (ITS-90). These thermometers were inserted horizontally into the copper cube and aligned along the center axis of the copper cube. In the case of a no-load state without anything on the upper surface, the temperature profile inside the copper cube linearly decreased from the lower part to the upper surface, which suggests that the heat conduction inside the copper cube can be regarded as a one-dimensional steady state. On the other hand, in the case of a transient state just after the contact surface thermometer was applied to the upper surface, the temperature profile became a round shape. We obtained good agreement between the curvature of the temperature profiles and the results estimated by using an error function used for a one-dimensional transient heat conduction problem. The temperature difference between the estimated temperature by linear extrapolation using two IPRTs and that by extrapolation using the error function was within \(0.2\,{^{\circ }}\hbox {C}\) in the transient state at around \(150\,{^{\circ }}\hbox {C}\). Over 10 min after the contact surface thermometer was applied, the temperature profile showed a linear shape again, which indicated that linear extrapolation using two IPRTs was well for the estimation of the reference surface temperature because the heat conduction state inside the copper cube came back to the one-dimensional steady state. Difference between the surface temperature and temperature detected by the contact surface thermometer was also observed after the contact surface thermometer touched on the upper surface. The difference was over \(0.1\,{^{\circ }}\hbox {C}\) at several minutes after the contact surface thermometer touching on the reference surface and was suppressed with passing time in the transient state and became negligible over 10 min.  相似文献   

2.
CETIAT’s calibration laboratory, accredited by COFRAC, is a secondary thermometry laboratory. It uses overflow and stirred calibration baths \((\hbox {from} -\,80\,{^{\circ }}\hbox {C} \hbox { up } \hbox { to } +\,215\,{^{\circ }}\hbox {C})\), dry blocks and furnaces \((\hbox {from } +\,100\,{^{\circ }}\hbox {C} \hbox { up } \hbox { to } +\,1050\,{^{\circ }}\hbox {C})\) and thermostatic chambers \((\hbox {from } -\,30\,{^{\circ }}\hbox {C} \hbox { up } \hbox { to } +\,160\,{^{\circ }}\hbox {C})\). Typical calibration uncertainties that can be reached for platinum resistance thermometers in a thermostatic bath are between \(0.03\,{^{\circ }}\hbox {C}\) and \(0.06\,{^{\circ }}\hbox {C}\). In order to improve its calibration capabilities, CETIAT is working on the implementation of a gas-controlled heat pipe (GCHP) temperature generator, used for industrial sensor calibrations. This article presents the results obtained during the characterization of water GCHP for industrial applications. This is a new approach to the use of a heat pipe as a temperature generator for industrial sensor calibrations. The objective of this work is to improve measurement uncertainties and daily productivity. Indeed, as has been shown in many studies (Dunn and Reay in Heat Pipes, Pergamon Press, Oxford, 1976; Merlone et al. 2012), the temperature of the system is pressure dependent and the response time, in temperature, follows the pressure accordingly. Thanks to this generator, it is possible to perform faster calibrations with smaller uncertainties. In collaboration with INRiM, the GCHP developed at CETIAT works with water and covers a temperature range from \(+\,30\,{^{\circ }}\hbox {C}\) up to \(+\,150\,{^{\circ }}\hbox {C}\). This device includes some improvements such as a removable cover, which allows us to have different sets of thermometric wells adjustable according to the probe to be calibrated, and a pressure controller based on a temperature sensor. This article presents the metrological characterization in terms of homogeneity and stability in temperature. A rough investigation of the response time of the system is also presented in order to evaluate the time for reaching thermal equilibrium. The results obtained in this study concern stability and thermal homogeneity. The homogeneity on 200 mm is better than 5 mK and with a calibration uncertainty reduced by a factor of three.  相似文献   

3.
The electrical and thermal properties with respect to the crystallization in \(\hbox {V}_{2}\hbox {O}_{5}\) thin films were investigated by measuring the resistance at different temperatures and applied voltages. The changes in the crystal structure of the films at different temperatures were also explored using Raman measurements. The thermal diffusivity of the crystalline \(\hbox {V}_{2}\hbox {O}_{5}\) film was measured by the nanosecond thermoreflectance method. The microstructures of amorphous and crystalline \(\hbox {V}_{2}\hbox {O}_{5}\) were observed by SEM and XRD measurements. The temperature-dependent Raman spectra revealed that a structural phase transition does not occur in the crystalline film. The resistance measurements of an amorphous film indicated semiconducting behavior, whereas the resistance of the crystalline film revealed a substantial change near \(250\,{^{\circ }}\hbox {C}\), and Ohmic behavior was observed above \(380\,{^{\circ }}\hbox {C}\). This result was due to the metal–insulator transition induced by lattice distortion in the crystalline film, for which \(T_{\mathrm{c}}\) was \(260\,{^{\circ }}\hbox {C}\). \(T_{\mathrm{c}}\) of the film decreased from 260 \({^{\circ }}\hbox {C}\) to \(230\,{^{\circ }}\hbox {C}\) with increasing applied voltage from 0 V to 10 V. Furthermore, the thermal diffusivity of the crystalline film was \(1.67\times 10^{-7}\,\hbox {m}^{2}\cdot \hbox {s}^{-1}\) according to the nanosecond thermoreflectance measurements.  相似文献   

4.
Molten nitrate salt is usually employed as heat transfer or energy storage medium in concentrating solar power systems to improve the overall efficiency of thermoelectric conversion. In the present work, the liquidus curves of the \(\hbox {LiNO}_{3}\)\(\hbox {NaNO}_{3}\)\(\hbox {KNO}_{3}\)\(\hbox {Ca}(\hbox {NO}_{3})_{2}\) system is determined by conformal ionic solution theory according to the solid–liquid equilibrium state of the binary mixture. The calculated eutectic temperature of the mixture is \(93.17\,{^{\circ }}\hbox {C}\), which is close to the experimental value of \(93.22\,{^{\circ }}\hbox {C}\) obtained from differential scanning calorimetry (DSC). Visualization observation experiments reveal that the quaternary eutectic mixture begins to partially melt when the temperature reaches \(50\,{^{\circ }}\hbox {C}\), and the degree of melting increases with temperature. The mixture is completely melted at \(\hbox {130}\,{^{\circ }}\hbox {C}\). The observed changes in the dissolved state at different temperatures correlate well with the DSC heat flow curve fluctuations.  相似文献   

5.
At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from \(70\,{^{\circ }}\hbox {C}\) to \(95\,{^{\circ }}\hbox {C}\) dew-point temperature, and the last modification allows an uncertainty of \(0.048\,{^{\circ }}\hbox {C}\) (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to \(95\,{^{\circ }}\hbox {C}\). In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within \(0.01\,{^{\circ }}\hbox {C}\) with PTB and NPL.  相似文献   

6.
This study describes the temperature and heat flow rate calibrations of a Calvet calorimeter (SETARAM, BT2.15) in the temperature range of 0–190 \({^{\circ }}\hbox {C}\). Temperature calibration is carried out using three reference materials, namely water, gallium, and indium, as specified in the International Temperature Scale of 1990 (ITS-90). The sample temperature of the Calvet calorimeter is corrected by the obtained mean value, \(-0.489 \,{^{\circ }}\hbox {C}\), of the measured extrapolated peak onset temperature (\(T_{e})\) when the heating rate (\(\upbeta )\) is zero (\(\Delta T_\mathrm{corr }(\upbeta ~=~0\))). The heat flow rate is calibrated using a reference material with a known heat capacity, namely SRM 720 \(\alpha \)-\(\hbox {Al}_{2}\hbox {O}_{3}\) (synthetic sapphire), which is traceable to the National Institute of Standards and Technology. From the heat flow rate measurements of the blank baseline and SRM 720, the proportional calibration factor, \(\hbox {K}_{\Phi }\), in the 0–190\( \,{^{\circ }}\hbox {C}\) temperature range was determined. The specific heat capacity of copper was measured with the obtained calibration values, and the measured data show consistency with the reference value.  相似文献   

7.
Two Co–C and Pd–C eutectic fixed point cells for both radiation thermometry and thermocouple thermometry were constructed at NMC. This paper describes details of the cell design, materials used, and fabrication of the cells. The melting curves of the Co–C and Pd–C cells were measured with a reference radiation thermometer realized in both a single-zone furnace and a three-zone furnace in order to investigate furnace effect. The transition temperatures in terms of ITS-90 were determined to be \(1324.18\,{^{\circ }}\hbox {C}\) and \(1491.61\,{^{\circ }}\hbox {C}\) with the corresponding combined standard uncertainty of \(0.44\,{^{\circ }}\hbox {C}\) and \(0.31\,{^{\circ }}\hbox {C}\) for Co–C and Pd–C, respectively, taking into account of the differences of two different types of furnaces used. The determined ITS-90 temperatures are also compared with that of INRIM cells obtained using the same reference radiation thermometer and the same furnaces with the same settings during a previous bilateral comparison exercise (Battuello et al. in Int J Thermophys 35:535–546, 2014). The agreements are within \(k=1\) uncertainty for Co–C cell and \(k = 2\) uncertainty for Pd–C cell. Shapes of the plateaus of NMC cells and INRIM cells are compared too and furnace effects are analyzed as well. The melting curves of the Co–C and Pd–C cells realized in the single-zone furnace are also measured by a Pt/Pd thermocouple, and the preliminary results are presented as well.  相似文献   

8.
Microstructure and composition are factors determining heat transfer in ZnO ceramic materials, which define the performance of the material after Joule heating, generated by electron transport. In this study, photothermal radiometry was applied to investigate the influence of the sintering temperature, ranging from \(800\,{^{\circ }}\hbox {C}\) to \(1300\,{^{\circ }}\hbox {C}\), by measuring the thermal diffusivity and thermal conductivity at room temperature, of commercial and sol–gel ZnO pellets. Our results show that the values of these thermal properties for both types of ZnO increase when the sintering temperature increases, displaying maximum energy dissipation at \(1200\,{^{\circ }}\hbox {C}\). Additionally, the role of the sintering temperature on the optical properties was also analyzed using diffuse reflectance spectroscopy, and from these data the optical band-gap was obtained.  相似文献   

9.
A small multiple fixed-point cell (SMFPC) was designed to be used as in situ calibration reference of the internal temperature sensor of a dry block calibrator, which would allow its traceable calibration to the International Temperature Scale of 1990 (ITS-90) in the operating range of the block calibrator from \(70\,^{\circ }\hbox {C}\) to \(430\,^{\circ }\hbox {C}\). The ITS-90 knows in this temperature range, three fixed-point materials (FPM) indium, tin and zinc, with their respective fixed-point temperatures (\(\vartheta _\mathrm {FP}\)), In (\(\vartheta _\mathrm {FP}\,{=}\,156.5985\,^{\circ }\hbox {C}\)), Sn (\(\vartheta _\mathrm {FP}\,{=}\,231.928\,^{\circ }\hbox {C}\)) and Zn (\(\vartheta _\mathrm {FP}\,{=}\,419.527\,^{\circ }\hbox {C}\)). All of these FPM are contained in the SMFPC in a separate chamber, respectively. This paper shows the result of temperature measurements carried out in the cell within a period of 16 months. The test setup used here has thermal properties similar to the dry block calibrator. The aim was to verify the metrological properties and functionality of the SMFPC for the proposed application.  相似文献   

10.
The selection of a material for making the hot and cold plates of high-temperature guarded hot plates (HTGHPs) working up to \(800\,{^\circ }\hbox {C}\) is still an issue. The material must be machinable, have a high mechanical stability to keep the high level of flatness of the plates and have a high thermal conductivity and a high resistance to oxidation when used in air. Nickel 201 alloy has been used in several instruments, but has shown, sometimes, problems of mechanical stability. The total hemispherical emissivity of the plates must be higher than 0.8 as recommended by the standards. Three ceramic materials, a silicon infiltrated silicon carbide (SiSiC), a machinable aluminum nitride and a sintered aluminum nitride (AlN) with high thermal conductivity claimed at ambient temperature, were selected for tests in thermal conductivity and opacity to thermal radiation. Three paints withstanding high temperatures were tested in total hemispherical emissivity and durability at high temperature. Above \(600\,{^\circ }\hbox {C}\), Nickel 201 alloy has a higher thermal conductivity than the three ceramics. Below \(600\, \,{^\circ }\hbox {C}\), the SiSiC and the sintered AlN have a thermal conductivity significantly higher than Nickel 201, but the sintered AlN shows a wide transparency spectral band at short wavelengths (below \(6.5\,\upmu \hbox {m}\)). Above \(300\,{^\circ }\hbox {C}\), the three paints have a total hemispherical emissivity above 0.8. One of the paints has polluted the specimens of an insulation material tested in thermal conductivity up to \(650\,{^\circ }\hbox {C}\). The other two can be recommended to coat the hot and cold plates of HTGHPs used up to \(800\,{^\circ }\hbox {C}\).  相似文献   

11.
Commercial paraffin wax used by Bolsius Nederland B.V. for manufacturing various kinds of candles was applied as a phase-change material (PCM) for cooling a 28 W high-power light emitting diode (LED) panel during its operation. The main problem arising during operation of an LED is thermal management. According to the manufacturer’s datasheet specifications (BioSolution Ltd. www.biosolution.pl), the operating temperature range for the LED street lamp UL28W is \((-30~{^{\circ }}\hbox {C})\) to \((+40~{^{\circ }}\hbox {C})\). The object of the present study was an LED panel containing 28 pieces of high-power 1W LEDs connected in series (4 LEDs in each of the 7 rows) mounted on an aluminum plate of dimensions 80 mm by 135 mm. The tested aluminum plate was placed in a block made of aluminum with a hollow compartment containing Bolsius paraffin wax of density \(914~\hbox {kg}\cdot \hbox {m}^{-3}\) at room temperature. Temperatures were recorded using K-type thermocouples at selected locations of the tested LED panel for several values of the power supplied to it, while utilizing PCM and without it. As the manufacturer of Bolsius wax candles does not provide any data on the thermal properties of the material used, it was necessary to carry out micro-calorimetric research. Thermophysical properties of the paraffin wax such as the apparent specific heat, enthalpy of phase transition and temperature of phase change transition during heating and cooling were determined using the Netzsch DSC 214 Polyma. The Netzsch TG 209F3 Tarsus was used for TG/DTG measurements. DSC investigations revealed the following thermal transitions taking place during the first heating: solid–solid transition (onset \(30.4~{^{\circ }}\hbox {C}\), peak at \(40.9~{^{\circ }}\hbox {C}\)), solid–liquid transition (onset \(47.7~{^{\circ }}\hbox {C}\), peak at \(54.9~{^{\circ }}\hbox {C}\), end at \(58.3~{^{\circ }}\hbox {C}\)), latent heat of energy storage \(201~\hbox {J}\cdot \hbox {g}^{-1}\), apparent specific heat corresponding to peak at \(41.5~{^{\circ }}\hbox {C}\) \((5.498~\hbox {J}\cdot \hbox {g}^{-1}\cdot \hbox {K}^{-1})\). DTG investigations revealed that the decomposition of paraffin wax is a two-step process. At \(283~{^{\circ }}\hbox {C}\) there was observed a slightly slower decomposition \((9.43\,\%\cdot \hbox {min}^{-1})\) than that at \(323~{^{\circ }}\hbox {C} (12.5\,\%\cdot \hbox {min}^{-1})\). The experimental results obtained upon cooling the high-power LED lamp during its operation can be applied to verify results of numerical modeling of the heat transfer problems with phase-change transitions. An attempt at modeling such a problem based on 1D fixed grid with variable time step approach was undertaken in this work.  相似文献   

12.
A 0.8PMN–0.2PT solid-solution ceramic was synthesized by columbite processing technique. The effects of sintering temperature on the density, structure and microstructure and in turn on the dielectric properties were investigated. The ceramics sintered at and above 1050\(^{\circ }\hbox {C}\) resulted in single-phase perovskite formation. However, high density >90% is achieved only after 1170\(^{\circ }\hbox {C}\). Microstructural analysis revealed that grain size increases with increase in sintering temperature. A significant increase in the peak of dielectric permittivity only after 1150\(^{\circ }\hbox {C}\) owing to increase in density is noted in this study. The quadratic law applied to this ceramic demonstrates that the transition is diffused. The broadness in phase transition and lower dielectric relaxation obtained for the composition demonstrate that the ceramic exhibits characteristics of both relaxor and normal ferroelectrics. The ceramic of composition 0.8PMN–0.2PT exhibits excellent dielectric properties \(\varepsilon _{\mathrm{r}\text {-}\mathrm{max}} =\) 20294?27338 at 100 Hz with \(T_{\mathrm{c}} = 100\)\(96^{\circ }\hbox {C}\) at low sintering temperature 1170–1180\(^{\circ }\hbox {C}\), respectively.  相似文献   

13.
Kinematic viscosity correlation has been developed for liquid petroleum fractions at 37.78\(\,^{\circ }\hbox {C}\) and \(98.89\,^{\circ }\hbox {C}\) (100 and \(210^{\circ }\hbox {F})\) standard temperatures using a large variety of experimental data. The only required inputs are the specific gravity and the average boiling point temperature. The accuracy of the correlation was compared with several other correlations available in the literature. The proposed correlations proved to be more accurate in predicting the viscosity at 37.78\(\,^{\circ }\hbox {C}\) and \(98.89\,^{\circ }\hbox {C}\) with average absolute deviations of 0.39 and \(0.72\hbox { mm}^{2}/\hbox {s}\), respectively. Another objective was to develop a relation for the variation of viscosity with temperature to predict the viscosity of petroleum fraction at a certain temperature from the knowledge of the viscosity for the same liquid at two other temperatures. The newly developed correlation represents a wide array of temperatures from 20 \(^{\circ }\hbox {C}\) to 150 \(^{\circ }\hbox {C}\) and viscosities from 0.14\(\hbox { mm}^{2}/\hbox {s}\) to 343.64\(\hbox { mm}^{2}/\hbox {s}\). The results have been validated with experimental data consisting of 9558 data points, yielding an overall deviation of \(0.248\hbox { mm}^{2}/\hbox {s}\) and \(\hbox {R}^{2}\) of 0.998. In addition, new formulas were developed to interconvert the viscosity of petroleum fractions from one unit of measure to another based on finding the best fit for a set of experimental data from the literature with \(R^{2}\) as high as 1.0 for many cases. Detailed analysis showed good agreement between the predicted values and the experimental data.  相似文献   

14.
The Russian national humidity standard of gases has been modernized in order to increase the number of reproducible quantities of humidity (relative humidity, dew/frost-point temperature, mole fraction) and to extend the humidity and operating temperature ranges. The basis of the standard comprises two humidity generators with operating temperature ranges from \(5\,^{\circ }\hbox {C}\) to \(90\,^{\circ }\hbox {C}\) and from \(-60\,^{\circ }\hbox {C}\) to \(15\,^{\circ }\hbox {C}\). The common working range (from \(5\,^{\circ }\hbox {C}\) to \(15\,^{\circ }\hbox {C}\)) allows comparison of the generators. The generators use the two-pressure method to generate humid gas defined in terms of the relative humidity (from 5 %rh to 98 %rh at temperatures from \(90\,^{\circ }\hbox {C}\) to \(-60\,^{\circ }\hbox {C}\)) and the one-pressure (or phase equilibrium) method to generate humid gas defined in terms of the vapor mole fraction (from 0.6 ppm to \(700\times 10^{3}\) ppm) and dew/frost-point temperature (from \(-79\,^{\circ }\hbox {C}\) to \(90\,^{\circ }\hbox {C}\)). The expanded uncertainty in the relative humidity is no more than 0.2 %rh, no more than 1.2 % in the vapor mole fraction, and no more than \(0.12\,^{\circ }\hbox {C}\) in the dew/frost-point temperature. The ordinary hygrometers are traceable to the national primary standard in accordance with the state hierarchical chain for measuring means of gas humidity. The state hierarchical chain consists of three branches for means of measurements: (a) mole fraction, (b) dew/frost-point temperature, and (c) relative humidity with each branch represented as the scheme: primary standard–secondary standard–working standard–ordinary hygrometer. Calibration and verification of working standards and ordinary hygrometers, and their traceability to the primary standard use methods of (i) direct measurements, (ii) direct comparison, or (iii) comparison with a comparator.  相似文献   

15.
The effect of thermal annealing in an inert atmosphere (argon) on the structural and thermochromic properties of \(\hbox {MoO}_{3}\) thin films was investigated. \(\hbox {MoO}_{3}\) thin films were deposited by thermal evaporation in vacuum of \(\hbox {MoO}_{3}\) powders. X-ray diffraction patterns of the films showed the presence of the monoclinic Magneli phase \(\hbox {Mo}_{9}\hbox {O}_{26}\) for annealing temperatures above \(250\,{^{\circ }}\hbox {C}\). Absorbance spectra of the films annealed in argon indicated that their thermochromic response increases with the annealing temperature in the analyzed range (23 \({^{\circ }}\hbox {C}\)–300 \({^{\circ }}\hbox {C}\)), a result opposite to the case of thermal annealings in air, for which case the thermochromic response shows a maximum value around 200 \({^{\circ }}\)C–225 \({^{\circ }}\)C and decreases for higher temperatures. These results are explained in terms of a higher density of oxygen vacancies formed upon thermal treatments in inert atmospheres.  相似文献   

16.
Vegetable oils have been widely studied as biofuel candidates. Among these oils, jojoba (Simmondsia chinensis) oil has attracted interest because it is composed almost entirely of wax esters that are liquid at room temperature. Consequently, it is widely used in the cosmetic and pharmaceutical industries. To date, research on S. chinensis oil has focused on to its use as a fuel and its thermal stability, and information about its thermal properties is scarce. In the present study, the thermal effusivity and conductivity of jojoba oil between \(20\,{^{\circ }}\hbox {C}\) and \(45\,{^{\circ }}\hbox {C}\) were obtained using the inverse photopyroelectric and hot-ball techniques. The feasibility of an inverse photopyroelectric method and a hot-ball technique to monitor the thermal conductivity, and the thermal effusivity of the S. chinensis is demonstrated. The thermal effusivity decreased from 538 \(\hbox {W}\cdot \,\hbox {s}^{1/2}\cdot \,\hbox {m}^{-2}\cdot \,\hbox {K}^{-1}\) to 378 \(\hbox {W}\cdot \,\hbox {s}^{1/2}\cdot \,\hbox {m}^{-2}\cdot \,\hbox {K}^{-1}\) as the temperature increased, whereas the thermal conductivity remained the same over the temperature range investigated in this study. The obtained results provide insight into the thermal properties of S. chinensis oil between \(20\,{^{\circ }}\hbox {C}\) and \(45\,{^{\circ }}\hbox {C}\).  相似文献   

17.
Industrial platinum resistance thermometer (IPRT) sensors or probes suffer from some instability on cycling over significant ranges of temperature and, specifically, from hysteresis in which the resistance tends to follow different paths for increasing temperatures compared with decreasing temperatures. The effect is well known, and cases of quite large hysteresis have been reported in the literature. Therefore, in establishing calibration and measurement capabilities for IPRT calibrations it is important to include an assessment of the performance which can be expected of a ‘typical good’ IPRT and to include this in the overall uncertainty which the laboratory can expect to achieve in such calibrations, even though the effect itself is outside the laboratory’s control. This paper presents results which have been obtained in cycling IPRT probes from four sources within various temperature ranges of current interest at NPL, between \(-196\,^{\circ }\hbox {C}\) and \(150\,^{\circ }\hbox {C}\), to see what levels of hysteresis may be expected. The cycles were carried out quite quickly in order to detect the hysteresis before it was mitigated by relaxation effects, but the time dependence was not itself studied. In most cases, hysteresis was \({<}0.0025\,^{\circ }\hbox {C}\) between \(0\,^{\circ }\hbox {C}\) and \(100\,^{\circ }\hbox {C}\), and \({<}0.0035\,^{\circ }\hbox {C}\) when the range extended down to \(-80\,^{\circ }\hbox {C}\) or up to \(150\,^{\circ }\hbox {C}\). Greater instability occurred when the sensors were cooled to \(-196\,^{\circ }\hbox {C}\).  相似文献   

18.
Inhomogeneity is the largest contributor to uncertainty in temperature measurements made with thermocouples, and the knowledge of inhomogeneity is essential if low-uncertainty measurements are required. Inhomogeneity is a particular problem for long-term applications at temperatures near or above 1500 \(^{\circ }\hbox {C}\), where pairs of alloyed noble-metal thermocouples must be used and the alloy components and potential contaminants become very mobile and cause large deviations in the Seebeck coefficient. While changes in inhomogeneity are a known and well-studied problem in noble-metal alloys at temperatures below 1100 \(^{\circ }\hbox {C}\), the effects are not well quantified at higher temperatures. This paper reports the first detailed measurements of inhomogeneity in a number of Type B and Land–Jewell thermocouples exposed to either short-term calibration up to 1600 \(^{\circ }\hbox {C}\) or long-term in situ measurements for a period of approximately 3000 h at 1600 \(^{\circ }\hbox {C}\). The inhomogeneity is measured in a high-resolution scanner operating over the range from 600 \(^{\circ }\hbox {C}\) to 900 \(^{\circ }\hbox {C}\). The results show that drifts of between 0.2 % and 0.6 % can be expected for reversible crystallographic and oxidation effects, whereas drift caused by irreversible contamination effects can be expected to be between 0.6 % and 1.1 %. It is also shown that the deviations in emfs caused by irreversible homogeneities in these thermocouples scale approximately linearly with temperature. This scalability allows uncertainties assessed at one temperature, to be extrapolated to other temperatures. Additionally it is shown that a preconditioning anneal at 1100 \(^{\circ }\hbox {C}\) should be applied both before and after calibration to remove undesirable crystallographic and rhodium-oxidation effects.  相似文献   

19.
More than one decade ago, an InGaAs detector-based transfer standard infrared radiation thermometer working in the temperature range from \(150\,{^{\circ }}\hbox {C}\) to \(1100\,{^{\circ }}\hbox {C}\) was built at TUBITAK UME in the scope of collaboration with IMGC (INRIM since 2006). During this timescale, the radiation thermometer was used for the dissemination of the radiation temperature scale below the silver fixed-point temperature. Recently, a new radiation thermometer with the same design but with different spectral responsivity was constructed and employed in the laboratory. In this work, we present the comparative study of these thermometers. Furthermore, the paper describes the measurement results of the thermometer’s main characteristics such as the size-of-source effect, spectral responsivity, gain ratio, and linearity. Besides, both thermometers were calibrated at the freezing temperatures of indium, tin, zinc, aluminum, and copper reference fixed-point blackbodies. The main study is focused on the impact of the spectral responsivity of thermometers on the interpolation parameters of the Sakuma–Hattori equation. Furthermore, the calibration results and the uncertainty sources are discussed in this paper.  相似文献   

20.
The Physikalisch-Technische Bundesanstalt determined the directional spectral emissivities of several widely used black coatings: Nextel 811-21, Herberts 1534, Aeroglaze Z306 and Acktar Fractal Black. These are and were often applied in different industrial and scientific applications. The measurements are taken angularly resolved over a range from \(10{^{\circ }}\) to \(70{^{\circ }}\). They cover the temperature range typical for the application of the respective coating and a wide wavelength range from \(4~\upmu \hbox {m}\) to \(100~\upmu \hbox {m}\). The respective directional total emissivities and hemispherical total emissivities are given as well. The measurements were taken under vacuum at the reduced background calibration facility to achieve low uncertainties and avoid atmospheric interferences. Additionally, some measurements were taken with the emissivity measurement setup in air.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号