Ventilation in Scandinavian buildings is commonly performed by means of a constant flow ventilation fan. By using a regulated fan, it is possible to make a seasonal adjustment of outdoor ventilation flow. Energy saving can be achieved by reducing the mechanical ventilation flow during the heating season, when natural ventilation driven by temperature differences between outdoor and indoor is relatively high. This ventilation principle has been called 'seasonally adapted ventilation (SAV)'. The aim was to study if a 25-30% reduction of outdoor ventilation flow during heating season influenced sick building syndrome (SBS) and the perception of the indoor environment. This was done in a 1-year cross-over intervention study in 44 subjects in a multi-family building. During the first heating season (November to April), one part of the building (A) got a reduced flow during the heating season [0.4-0.5 air exchanges per hour (ACH)] while the other part (B) had constant flow (0.5-0.8 ACH). The next heating season, part A got constant flow, while part B got reduced ventilation flow. Reduced ventilation increased the relative air humidity by 1-3% in the living room (mean 30-37% RH), 1-5% in the bathroom (mean 48-58% RH) during heating season. The room temperature increased 0.1-0.3 degrees C (mean 20.7-21.6 degrees C), mean carbon dioxide (CO2) concentration in the bedroom increased from 920 to 980 p.p.m. at reduced flow. The indoor air quality was perceived as poorer at reduced outdoor airflow, both in the bedroom and in the apartment as a whole. There was a significant increase of stuffy odor (P = 0.05) at reduced outdoor airflow and the indoor air quality was perceived as poorer, both in the bedroom (P = 0.03) and in the apartment as a whole (P = 0.04). No significant influence on SBS symptoms or specific perceptions such as odors, draught, temperature, air dryness or stuffy air could be detected. In conclusion, reducing the ventilation flow in dwellings to a level below the current Swedish ventilation standard (0.5 ACH) may cause a perception of impaired air quality. Technical measurements could only demonstrate a minor increase of indoor temperature, relative air humidity, and bedroom CO2 concentration. This illustrates that it is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. PRACTICAL IMPLICATIONS: It is important to combine technical measurements with a longitudinal evaluation of occupant reactions, when evaluating energy-saving measures. Reduction of outdoor airflow in dwellings below the current ventilation standard of 0.5 ACH may lead to a perception of impaired air quality, despite only a minor increase of bedroom CO2-concentration.  相似文献   

2.
Indoor/outdoor measurements have been performed in the Oslo metropolitan area during summer and winter periods (2002-2003) at two different residential houses. The objective of the measurement study was to characterize, physically and chemically, the particulate matter (PM) and gaseous pollutants associated with actual human exposure in the selected places, and their indoor/outdoor relationship. In this paper, we focus on the PM measurements and examine the relationship between the indoor and outdoor PM concentrations taking into account the ventilation rate, indoor sources and meteorological conditions. The indoor/outdoor measurements indicate the important contribution of the outdoor air to the indoor air quality and the influence of specific indoor sources such as smoking and cooking to the concentration of PM inside houses. However, no specific correlation was found between the indoor/outdoor concentration ratio and the meteorological parameters. This study provides information on the physical characteristics and the relationship of indoor to outdoor concentration of particulate matter in residential houses. Moreover, the parameters that influence this relationship are discussed. The results presented here are specific to the sampled houses and conditions used and provide data on the actual human exposure characteristics which occur in the spatial and temporal scales of the present study.  相似文献   

3.
Wu PC  Li YY  Chiang CM  Huang CY  Lee CC  Li FC  Su HJ 《Indoor air》2005,15(1):19-26
Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R(2) = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R(2) = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings. PRACTICAL IMPLICATIONS: As control of indoor microbial contamination has become an increasing concern around the world, feasibility and effectiveness of adopting ventilation approach has attracted a significant interest. This field investigation demonstrated, quantitatively, critical variables to be taken into consideration while applying such a measure, including the kinds of microbes to be removed and the types of ventilation system already in place.  相似文献   

4.
Indoor exposure to air contaminants penetrating from the outdoor environment depends on a number of key processes and parameters such as the ventilation rate, the geometric characteristics of the indoor environment, the outdoor concentration and the indoor removal mechanisms. In this study two alternative methods are used, an analytical and a numerical one, in order to study the time lag and the reduction of the variances of the indoor concentrations, and to estimate the deposition rate of the air contaminants in the indoor environment employing both indoor and outdoor measurements of air contaminants. The analytical method is based on a solution of the mass balance equation involving an outdoor concentration pulse which varies sinusoidally with the time, while the numerical method involves the application of the MIAQ indoor air quality model assuming a triangular pulse. The ratio of the fluctuation of the indoor concentrations to the outdoor ones and the time lag were estimated for different values of the deposition velocity, the ventilation rate and the duration of the outdoor pulse. Results have showed that the time lag between the indoor and outdoor concentrations is inversely proportional to the deposition and ventilation rates, while is proportional to the duration of the outdoor pulse. The decrease of the ventilation and the deposition rate results in a rapid decrement of the variance ratio of indoor to outdoor concentrations and to an increment of the variance ratio, respectively. The methods presented here can be applied for gaseous species as well as for particulate matter. The nomograms and theoretical relationships that resulted from the simulation results and the analytical methods respectively were used in order to study indoor air phenomena. In particular they were used for the estimation of SO2 deposition rate. Implications of the studied parameters to exposure studies were estimated by calculating the ratio of the indoor exposure to the exposure outdoors. Limitations of the methods were explored by testing various scenarios which are usually met in the indoor environment. Strong indoor emissions, intense chemistry and varying ventilation rates (opening and closing of the windows) were found to radically influence the time lag and fluctuation ratios.  相似文献   

5.
To conserve energy, office buildings with air-conditioning systems in Thailand are operated with a tight thermal envelope. This leads to low fresh-air ventilation rates and is thought to be partly responsible for the sick building syndrome symptoms reported by occupants. The objectives of this study are to measure concentrations and to determine sources of 13 volatile organic compounds (VOCs) in office buildings with air-conditioning systems in the business area of Bangkok. Indoor and outdoor air samples from 17 buildings were collected on Tenax-TA sorbent tubes and analyzed for individual VOCs by thermal desorption-gas chromatography/mass spectrometry (TD–GC/MS). Building ventilation was measured with a constant injection technique using hexafluorobenzene as a tracer gas. The results show that the VOC concentrations varied significantly among the studied buildings. The two most dominant VOCs were toluene and limonene with average concentrations of 110 and 60.5 μg m−3, respectively. A Wilcoxon sum rank test indicated that the indoor concentrations of aromatic compounds and limonene were statistically higher than outdoor concentrations at the 0.05 level, while the indoor concentrations of chlorinated compounds were not. Indoor emission factors of toluene and limonene were found to be highest with the average values of 80.9 and 18.9 μg m−2 h−1, respectively. Principal component analysis was applied to the emission factors of 13 VOCs, producing three components based on source similarities. Furthermore, a questionnaire survey investigation and field measurements of building air exchange pointed to indoor air complaints related to inadequate ventilation.  相似文献   

6.
Abstract We report approximately 500 indoor–outdoor air exchange rate (AER) calculations based on measurements conducted in residences in three US metropolitan areas in 1999–2001: Elizabeth, New Jersey; Houston, Texas; and Los Angeles County, California. Overall, a median AER across these urban areas and seasons was 0.71 air changes per hour (ACH, or per hour; n = 509) while median AERs measured in California (n = 182), New Jersey (n = 163), and Texas (n = 164) were 0.87, 0.88, and 0.47 ACH, respectively. In Texas, the measured AERs were lower in the summer cooling season (median = 0.37 ACH) than in the winter heating season (median = 0.63 ACH), likely because of the reported use of room air conditioners as Houston is typically hot and humid during the summer. The measured AERs in California were higher in summer (median = 1.13 ACH) than in winter (median = 0.61 ACH). Because the summer cooling season in Los Angeles County is less humid than in New Jersey or Texas, natural ventilation through open windows and screened doors likely increased measured AER in California study homes. In New Jersey, AER were similar across heating and cooling seasons, although the median AER was relatively lower during the spring.

Practical Implications

Adequate ventilation or air exchange rate (AER) for an indoor environment is important for human health and comfort, and relevant to building design and energy conservation and efficiency considerations. However, residential AER data, especially measured by more accurate non‐toxic tracer gas methodologies, are at present quite limited worldwide, and are insufficient to represent the variations across regions and seasons within and between homes, including apartments and condominiums in more densely populated urban areas. The present paper presents quantitative and qualitative data to characterize residential AERs in three US urban areas with different climate attributes.  相似文献   

7.
Ten homes were monitored at regular intervals from June 1994 through April 1995 as part of a Public Health Assessment in Southeast Chicago for exposure to volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs), and elements. Simultaneous 24-h indoor and outdoor samples were collected. VOCs were and analyzed using USEPA Method TO-14 with Selected Ion Monitoring Mass Spectrometry (GC/MS). PAHs were analyzed using USEPA Method TO-13 with GC/MS. Elements were collected on quartz fiber filters and analyzed by Inductively Coupled Argon Plasma (ICP) spectroscopy or Graphite Furnace Atomic Absorption (GFAA). Continuous measurements of CO2 and temperature were recorded for each indoor sample. Twenty-four h total CO2 emissions were determined from occupancy and estimated gas stove usage and were moderately correlated (R2 = 0.19) with 24 h average indoor CO2 concentrations. Modeled 24-h air exchange rates ranged from 0.04 to 3.76 air changes h-1 (ACH), with mean of 0.52 ACH. Median particle penetration was 0.89. Emission rates were calculated for each pollutant sampled. Using a detailed housing survey and field sampling questionnaires, it was possible to evaluate associations between housing characteristics and source activities, and pollutant source rates. The data indicate that several predictor variables, including mothball storage, air freshner use, and cooking activities, are reasonable predictors for emission rates for specific pollutants in the homes studied.  相似文献   

8.
Although elevated nitrogen dioxide (NO2) exposures may exacerbate asthma, few studies have examined indoor NO2 levels in low-income, urban neighborhoods, where asthma prevalence is high. As part of the Healthy Public Housing Initiative, NO2 was measured in 77 homes within three Boston public housing developments, using Palmes tubes placed in the kitchen, living room, and outdoors. Air exchange rates (AERs) were assessed using a perfluorocarbon tracer technique. Overall NO2 levels were [mean (ppb)+/-s.d.]: kitchen (43+/-20, n=100), living room (36+/-17, n=102), outdoor (19+/-6, n=91). Indoor NO2 levels were significantly higher in the heating season (living room: 43 ppb vs. 26 ppb, kitchen: 50 ppb vs. 33 ppb), while AERs were significantly lower in the heating season (medians 0.49/h vs. 0.85/h). Significant univariate predictors of indoor concentrations include: outdoor NO2 levels, AERs, and occupancy. AERs and outdoor NO2 remained significant in multivariate models (P<0.05). A dummy variable for supplemental heating with gas stove was not significant (P=0.14), but had a large, positive coefficient. Indoor NO2 levels in this cohort are higher than those generally reported in residential US settings, associated in part with increased gas stove usage and decreased AERs during the heating season. PRACTICAL IMPLICATIONS: Indoor air quality is mainly a function of outdoor concentrations, indoor sources, ventilation, and residential behavior. Indoor exposures to nitrogen dioxide and other combustion pollutants may be elevated within low-income housing developments due to the presence of multiple sources, poor ventilation, small apartment size, and behavioral responses to apartment conditions (e.g. supplemental heating with gas stove). This information may be used by housing authorities and other landlords to decrease potential environmental stressors, through interventions such as source substitution and improved ventilation, particularly for sensitive sub-populations such as asthmatics.  相似文献   

9.
新风对于稀释室内空气中的有害物质、改善室内环境有着重要的意义。新风量则是衡量新风的有效手段,目前不设独立新风系统的建筑室内新风量测量广泛采用CO_2示踪气体法。本文通过一系列实验探讨CO_2初始浓度、门窗开关方式、室外风速以及室内杂物对室内新风量检测结果的影响。实验结果表明CO_2初始浓度、门窗开关方式、室外风速、室内杂物这些因素均对新风量检测值均存在不同程度的影响,其中室外风速和室内有无杂物对新风量检测结果的影响最为明显。  相似文献   

10.
This study examined indoor nitrogen dioxide (NO2) concentrations in Ashford, Kent (UK), Menorca Island and Barcelona city (Spain) and the contribution of their most important indoor determinants (e.g. gas combustion appliances and cigarette smoking). The homes examined (n = 1421) were those from infants recruited for the Asthma Multicentre Infants Cohort Study, which aimed to assess, using a standard protocol, the effects of pre- and post-natal environmental exposures in the inception of atopy and asthma. Indoor NO2 was measured using passive filter badges placed on a living room wall of the homes for between 7 and 15 days. Homes in the three centers had significantly different concentrations of indoor NO2, with those in Barcelona showing the highest levels (median NO2 levels: 5.79, 6.06 and 23.87 p.p.b. in Ashford, Menorca and Barcelona, respectively). Multiple regression analysis showed that the principal indoor determinants of NO2 concentrations in the three cohorts were the heating/cooking fuel used in the house (gas fire increased average NO2 concentrations by 1.27-fold and gas cooker by 2.13 times), parental cigarette smoking and season of measurement. Those variables significantly related to indoor NO(2) accounted for 23, 14 and 39% of the variation in indoor NO2 concentration in Ashford, Barcelona and Menorca, respectively. In all the cohorts combined, 52% of the variation could be explained in this way. Although outdoor NO2 was not measured concurrently, its additional contribution was estimated. In conclusion, despite differences in indoor NO2 mean concentrations probably reflecting different outdoor NO2 level, home factors affecting indoor NO2 values and their specific contributions were constant across the three cohorts. PRACTICAL IMPLICATIONS: This study found that principal determinants associated to indoor NO2 in three different sites of Europe: Ashford (UK), Barcelona and Menorca (Spain) were the energy source present in the home and cigarette smoking, despite these areas presented different climates, levels of outdoor contamination, housing characteristics and ventilation behavior. It is suggested that interventions in homes of these three centers will need to address principally cigarette smoking and gas combustion appliances. These latter factors require institutional intervention, while cigarette smoking mainly require personal changes.  相似文献   

11.
In this study, we performed a series of trials to measure the infiltration air exchange rate (ACH) of several single-family dwellings throughout Catalonia, as well as the ACH of sealed rooms that could be used as indoor shelters. A shelter is an indoor room where people can take protection in case of a toxic gas release, while the toxic cloud passes through the dwelling. Experimental measurements were made using the tracer gas decay technique with CO2 as the tracer gas in 2 periods—summer and winter—with the aim of characterizing air infiltration in Catalan dwellings. The geometric means obtained for the ACH of shelters and dwellings were 0.16 and 0.23 h−1, respectively, that is, lower than those reported for North American (0.56 h−1) and Greek (0.76 h−1) dwellings. In general, the ACH was lower for shelters than for dwellings, and the average reduction obtained in shelters with respect to dwellings was 35%. The largest reductions were obtained in old dwellings with small floor areas and few stories. As for meteorological conditions, we found that the ACH of dwellings was more closely linked to wind speed than indoor–outdoor temperature difference, while the ACH of shelters was more affected by indoor–outdoor temperature and temperature differences inside the dwelling, particularly in dwellings with 3 or more stories.  相似文献   

12.
Here we report indoor and outdoor concentrations of NO2 for Erfurt and Hamburg and assess the contribution of the most important indoor sources (e.g. the presence of gas cooking ranges, smoking) and outdoor sources (traffic exhaust emissions). We examined the relative contribution of the different sources of NO2 to the total indoor NO2 levels in Erfurt and Hamburg. NO2 indoor concentrations in Hamburg were slightly higher than those in Erfurt (i.e. living room: 15 microg m(-3) for Erfurt and 17 microg m(-3) for Hamburg). A linear regression model including the variables, place of residence, season and outdoor NO2 levels, location of the home within the city, housing and occupant characteristics accounted for 38% of the NO2 variance. The most important predictors of indoor NO2 concentrations were gas in cooking followed by other characteristics, such as ventilation or outdoor NO2 level. Residences in which gas was used for cooking, or in which occupants smoked, had substantially higher indoor NO2 concentrations (41 or 18% increase, respectively). An increase in the outdoor NO2 concentration from the 25th to the 75th-percentile (17 microg m(-3)) was associated with a 33% increase in the living room NO2 concentration. Multiple regression analysis for both cities separately illustrated that use of gas for cooking was the major indoor source of NO2. This variable caused a similar increase in the indoor NO2 levels in each city (43% in Erfurt and 47% in Hamburg). However, outdoor sources of NO2 (motor vehicle traffic) contributed more to indoor NO2 levels in Hamburg than in Erfurt.  相似文献   

13.
The scientific literature through 2005 on the effects of ventilation rates on health in indoor environments has been reviewed by a multidisciplinary group. The group judged 27 papers published in peer-reviewed scientific journals as providing sufficient information on both ventilation rates and health effects to inform the relationship. Consistency was found across multiple investigations and different epidemiologic designs for different populations. Multiple health endpoints show similar relationships with ventilation rate. There is biological plausibility for an association of health outcomes with ventilation rates, although the literature does not provide clear evidence on particular agent(s) for the effects. Higher ventilation rates in offices, up to about 25 l/s per person, are associated with reduced prevalence of sick building syndrome (SBS) symptoms. The limited available data suggest that inflammation, respiratory infections, asthma symptoms and short-term sick leave increase with lower ventilation rates. Home ventilation rates above 0.5 air changes per hour (h(-1)) have been associated with a reduced risk of allergic manifestations among children in a Nordic climate. The need remains for more studies of the relationship between ventilation rates and health, especially in diverse climates, in locations with polluted outdoor air and in buildings other than offices. PRACTICAL IMPLICATIONS: Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants. This review and assessment indicates that increasing ventilation rates above currently adopted standards and guidelines should result in reduced prevalence of negative health outcomes. Building operators and designers should avoid low ventilation rates unless alternative effective measures, such as source control or air cleaning, are employed to limit indoor pollutant levels.  相似文献   

14.
为了探求具有良好自然通风的传统民居形式,本文对云南彝族传统民居的室内、外空气温度和风速进行了实测;并利用CFD软件对其室内和院落的风环境进行了模拟,分析各建筑因素(院门的开启、院墙的高低、畜棚的位置及门窗的设置)对自然通风的影响。结果表明,合理设置窗户和百叶、增加通风槽、扩大正房厦子能有效提高室内的自然通风效果;合理调整附属建筑的位置、院落尺寸和院墙高低能改善院落的自然通风效果。在此基础上,提出了改进风环境的设计建议。  相似文献   

15.
More and more studies reported that there were insufficient ventilation and excessive CO_2 concentration in air-conditioned residential buildings, but few solutions were provided. This study investigates the overnight evolution of CO_2 concentration in air-conditioned residential buildings and then focuses mainly on the evaluation of three ventilation strategies, including overnight natural ventilation, short-term mechanical ventilation and short-term natural ventilation. On-site measurements were conducted in a typical residential bedroom in Hong Kong in September. The indoor and outdoor CO_2 concentration, air temperature and relative humidity as well as the outdoor wind speed during the measurements were analysed. Ventilation rates were calculated based on the time series of CO_2 concentration. This study confirms that additional ventilation is usually needed in air-conditioned residential buildings. Overnight natural ventilation with even a small opening is associated with excessive energy consumption and deteriorated indoor thermal environment. Short-term natural ventilation strategies are inefficient and uncontrollable. Compared to the best short-term natural ventilation strategy, a reasonably designed short-term mechanical ventilation strategy requires only a 41% of ventilation period to complete one full replacement of indoor air and to reach a lower indoor CO_2 concentration. Nighttime case studies and a theoretical analysis suggest that a few several-minute mechanical ventilation periods could potentially maintain an acceptable indoor air quality for a normal sleeping period of 8 h.  相似文献   

16.
Abstract Investigations of particle concentration levels and size distribution were conducted in the complex hospital system of the Royal Children's and the Royal Brisbane Hospitals in Queensland, Australia. The aim of the measurements was to provide an indication of particulate sources in the hospital environment and relate particle characteristics to the operating parameters of the hospitals. The measurements were performed using the most advanced instrumentation for size classification in the submicrometer and supermicrometer levels. The conclusions from the investigation were: (i) that indoor concentration levels of particle numbers are closely related to outdoor concentration levels, indicating that outdoor particulates were the main contributor to the indoor particulates in the hospitals under investigations; and (ii) that the performance of filtration/ventilation systems is the most critical parameter in reducing general particulate concentration levels in those hospital units where medical procedures can result in generation of potentially hazardous organic aerosols.  相似文献   

17.
Indoor air quality (IAQ) has been a matter of public concern these days whereas air pollution is normally monitored outdoors as part of obligations under the National air quality strategies. Much little is known about levels of air pollution indoors. Simultaneous measurements of indoor and outdoor carbon monoxide (CO) and oxides of nitrogen (NO and NO2) concentrations were conducted at three different environments, i.e. rural, urban and roadside in Agra, India, using YES - 205 multigas monitor during the winter season, i.e. October 2002-February 2003. A statistical correlation analysis of indoor concentration levels with outdoor concentrations was carried out. CO was maximum at roadside locations with indoor concentrations 2072.5 +/- 372 p.p.b. and outdoor concentrations 1220 +/- 281 p.p.b. (R2 = 0.005). Oxides of nitrogen were found maximum at urban site; NO concentration was 385 +/- 211 and 637 +/- 269 p.p.b. for indoors and outdoors respectively (R2 = 0.90792), where as NO2 concentration was 255 +/- 146 p.p.b. for indoors and 460 +/- 225 p.p.b. for outdoors (R2 = 0939464). Although indoor concentration at all the houses of the three sites have a positive correlation with outdoor concentration, CO variation indoors was very less due to outdoor sources. An activity schedule of inside and outside these homes were also prepared to see its influence and concentrations of pollutants. As standards for indoor air were not available for the Indian conditions these were compared with the known standards of other countries, where as outdoor concentrations were compared with the standards given by the Central Pollution Control board, which shows that indoor concentrations of both NO(x) and CO lie below permissible limits but outdoor concentrations of NO(x) cross the standard limits. PRACTICAL IMPLICATIONS: 'India currently bears the largest number of indoor air pollution (IAP) related health problems in world. An estimated 500,000 women & children die in India each year due to IAP-related cause--this is 25% of estimated IAP-related deaths worldwide. This study will be useful for policy makers, health related officials, academicians and Scientists who have interest in countries of developing world'.  相似文献   

18.
Air quality in two large athletic halls with different ventilation (natural and mechanical) was investigated in relation to outdoor pollution and meteorological conditions. Simultaneous measurements of O3, NO, NO2 and SO2 were performed in the halls at two heights (at the arena and spectators’ seats) and outdoors. BTX concentrations at the spectators’ seats and outdoor NMHCs, CH4, PM10 and CO concentrations were also measured. Analysis of diurnal variations of the pollutants’ concentrations, cross correlation analysis of the concentration time-series and principal component analysis were applied to the collected data. Results revealed that outdoor pollution significantly affected indoor air quality of both halls. However, this effect was different for the two buildings, depending on the ventilation types, the wind direction prevailing at the areas and the kind of indoor activity recorded. It was found that the latter parameters controlled the pollutants concentration levels in the halls and their response to the changes of the outdoor pollution levels. Temperature and pollution stratification enhancing during athletic events were also evident in both halls but with different characteristics observed, such as the spatial distribution of the indoor pollutants. The airflow patterns prevailing in each hall, imposed by the ventilation operation schemes were important factors.  相似文献   

19.
The sampling rate of a nitrogen dioxide (NO2) passive sampling badge was evaluated in indoor environments including an unoccupied research house, residential houses, and an office. Measurements from the NO2 badges were compared with those of a chemiluminescent analyzer the EPA reference method, by placing them near to the sample inlet of the chemiluminescent analyzer In this study, we used a new sampling rate for the NO2 badge placed in indoor environments (an overall mass transfer coefficient of 0.10 cm/s) smaller than the rate previously reported for the badge when used outdoors. The new rate provides more accurate measurements of NO, concentrations in indoor environments. Indoor NO2 concentrations were also measured with the NO2 badges exposed to a constant wind velocity provided by a wind tunnel. Since the measurements of the badge with a constant wind velocity agreed well with the reference method, the badges could be assumed to be a secondary reference measurement. With the badges used as the secondary reference measurement, we developed a portable wind tunnel to evaluate a personal exposure measurement by the badge. The results are presented in Environment International (Lee et al., 1993). Precision of the badge measurements was as good as an intraclass correlation coefficient of 0.9779. It was determined that placement of the badge should be at least 10 cm out from an indoor wall surface to avoid undersampling due to NO2 gradients near the surface.  相似文献   

20.
The purpose of the study was to gather information about the actual ventilation and indoor air quality and to evaluate the differences between houses and apartments with different ventilation systems. A sample of 242 dwellings in the Helsinki metropolitan area was studied over periods of no weeks during the 1988-1989 heating season. The mean air-exchange rates had a high variation (average 0.52 l/h, range 0.07-1.55 l/h). The ASHRAE minimum value of 0.35 l/h was not achieved in 28% of the dwellings. The air-exchange rates were significantly her in the houses than in the apartments (averages 0.45/0.64 l/h, p < 0.001); in the natural ventilation systems they, were slightly her than in the mechanical systems. The average temperature in the bedrooms was approximately 22 °C (range 18–27 °C), slightly but significantly higher in the apartment than in the houses. The average dust depositions were higher in the balanced ventilation systems than in the other systems. The median radon concentration was 82 Bq/m3 (range 5-866 Bq/m3); the Finnish target value of 200 Bq/m3 was exceeded in 17% of the houses but in none of the apartment. The measurements indicate that the indoor air quality in Finnish dwellings is not always satisfactory with reference to human health and comfort.  相似文献   