共查询到20条相似文献,搜索用时 0 毫秒
1.
《Contact lens & anterior eye》2021,44(1):18-23
PurposeTo determine the antimicrobial efficacy of a povidone-iodine system (PVP-I; cleadew, OPHTECS Corporation, Kobe, Japan), a peroxide system (AOSEPT Plus with HydraGlyde, Alcon, Fort Worth, TX), and a chemical multipurpose system (renu fresh, Bausch & Lomb, Rochester, NY) on contact lens case surfaces that are both in contact and not in contact with the solutions during lens disinfection.MethodsThe surfaces of the inner walls, underside of the lid, and lens holder (if applicable) of the cases were inoculated with P. aeruginosa ATCC 27853. The cases were disinfected with the solutions as per their manufacturer instructions. After disinfection, the inoculated surfaces were swabbed and the amount of surviving P. aeruginosa was determined. Following this experiment, separate cases were inoculated and disinfected as before. This time the cases were agitated after recommended disinfection time and the amount of P. aeruginosa in the disinfecting solution was quantified immediately, and again after resting for 7 days. Experiments were conducted in triplicate (n = 3).ResultsUnits are expressed in log CFU. All three solutions significantly reduced P. aeruginosa on direct-contact surfaces (all p < 0.039). On non-contact surfaces, the reduction of P. aeruginosa in the PVP-I system (pre-disinfection: 6.8 ± 0.5, post-disinfection: 1.0 ± 0.0; p < 0.001) was significant, but not for the hydrogen peroxide system (pre-disinfection: 6.3 ± 0.6, post: 5.5 ± 0.5; p = 0.194) and the chemical multipurpose system (pre-disinfection: 6.6 ± 0.1, post-disinfection: 5.6 ± 0.8; p = 0.336). After 7 days post-disinfection, no P. aeruginosa regrowth was observed in the PVP-I system (Day 1: 1.0 ± 0.0, Day 7: 1.0 ± 0.0; p = 1) and the chemical multipurpose system (Day 1: 4.2 ± 0.2, Day 7: 1.8 ± 0.9; p = 0.012), however regrowth was observed in the hydrogen peroxide system (Day 1: 3.4 ± 0.6, Day 7: 6.1 ± 0.4; p = 0.003).ConclusionThe PVP-I system was more effective against P. aeruginosa on non-contact surfaces than the hydrogen peroxide system or the chemical multipurpose system and is capable of inhibiting regrowth of P. aeruginosa for at least 7 days post-disinfection. 相似文献
2.
《Contact lens & anterior eye》2014,37(5):346-350
PurposeTo compare lens orientation and rotational recovery of five currently available soft toric lenses.MethodsTwenty subjects were recruited and trialed with each of the study lenses in a random order. Study lenses were PureVision® Toric (B&L), Air Optix® for Astigmatism (Alcon), Biofinity® Toric (CooperVision), Acuvue® Advance for Astigmatism (Vistakon), and Proclear® Toric (CooperVision). Lens orientation in primary position to determine the lens rotation form the vertical position and rotational recovery to primary gaze orientation following a 45° manual misorientation for the different lenses was compared.ResultsThe Biofinity Toric showed the lowest rotation from the vertical position and the Proclear Toric the highest. Also, the highest and the lowest reorientation speed were related to the Biofinity Toric and the Acuvue Advance for Astigmatism, respectively. The Repeated Measures ANOVA showed a significant difference in the lens rotation (P = 0.004) and rotational recovery (P < 0.001) among different contact lenses and the performed multiple comparisons indicated differences in rotation and also in reorientation speed were only seen between the Biofinity Toric when compared to four other lenses (P < 0.05).ConclusionAlthough there was appropriate fitting, based upon lens orientation and reorientation speed, with each of the study lenses it would appear that the optimized ballast technique used in the design of the Biofinity Toric helps reduce lens rotation and improve rotational recovery compared to others. 相似文献
3.
《Contact lens & anterior eye》2020,43(2):185-188
BackgroundContact lens related keratitis is a frequent presentation to acute ophthalmology services. Patients often do not recall being counselled regarding the safe use of contact lenses therefore fail to comply with guidance.This study aimed to identify the content and format of advice given to patients with contact lens keratitis concerning appropriate hygiene practices, determine their compliance with this and finally characterise optometrist practices regarding contact lens advice provided to patients.MethodsAll adult patients presenting with contact lens related keratitis to the acute ophthalmology clinic were asked to complete a survey. Information was collected on lens type, format of advice received and compliance.Community optometrists were asked to complete an electronic survey on their contact lens review practices and routine patient education.ResultsAll patients surveyed recalled counselling on initiation of contact lenses; however 12% (6/50) were given no advice on return visits. This advice was in written format for 20% (10/50) of patients on initiation increasing to 32% (16/50) on renewal.Many patients slept (22%), showered (44%) or swam (36%) in lenses. 92% cleaned their contact lenses appropriately, but cases were washed infrequently (19% of cases cleaned < monthly) or with tap water (27%).All optometrists surveyed claimed to provide advice to patients in either written or verbal format for new and returning contact lens users. 49% (16/33) of optometrists gave written advice to patients on initial contact lens fitting, but only 1/33 continued with written advice for repeat customers.ConclusionThis study identified that although most patients were informed of appropriate hygiene requirements, compliance was poor. Optometrists regularly provide verbal advice but do not routinely offer written support and there is a mismatch between patient recollection and self-reported optometrist practice. It is suggested that patient education needs greater emphasis and both verbal and written information should be regularly provided on initial review and follow up assessments. 相似文献
4.
《Contact lens & anterior eye》2021,44(3):101334
PurposeTo investigate the interaction of a novel low molecular weight hyaluronic acid derivative containing hydrophobic groups with soft contact lenses and its effect on lens hydrophilicity compared with a conventional form of hyaluronic acid.MethodsThis investigation studied the uptake of fluorescently-labelled hyaluronic acid and a low molecular weight hyaluronic acid derivative to four types of contact lenses using fluorescent microscopy and confocal laser scanning microscopy. Further, the four lens types were used to compare efficacy in improving hydrophilicity, as well as maintenance of contact angle measurements, in commercially available multipurpose solutions that contained either hyaluronic acid, the low molecular weight hyaluronic acid derivative, or an alternative wetting agent.ResultsThe low molecular weight hyaluronic acid derivative was found to sorb more readily to silicone hydrogel lenses and exhibit a greater accumulation over time than conventional hyaluronic acid. Multipurpose solutions containing the low molecular weight hyaluronic acid derivative showed an increase in lens hydrophilicity through decreases in contact angle measurements when compared with those obtained from lenses treated with multipurpose solutions containing conventional hyaluronic acid or alternative wetting agents. This increase in lens hydrophilicity associated with the low molecular weight hyaluronic acid derivative was also maintained over multiple cycles in phosphate buffered saline, while alternative solutions with conventional hyaluronic acid did not.ConclusionOverall, lens treatment using a low molecular weight hyaluronic acid derivative-based solution lead to improved in vitro lens hydrophilicity. 相似文献
5.
6.
《Contact lens & anterior eye》2023,46(1):101742
PurposeTo determine the frequency and severity of ocular symptoms and signs in new orthokeratology (ortho-k) subjects using a povidone iodine (PI) disinfecting system compared to those present before lens wear, and whether these were associated with cleaning regimes.MethodsThis study recruited 80 subjects from two myopia control studies, who used a PI disinfecting solution for routine use. Ocular symptoms and signs at baseline, one- and six-month after lens wear were reported via questionnaires and ocular examination, respectively. To determine if rates of occurrence were attributable to differences in cleaning regime, subjects were randomly assigned into four groups with respect to routine care procedures, which involved various combinations of rubbing and use of a daily and/or enzymatic cleaner.ResultsSixty-eight subjects completed all aspects of the study. As there were no significant differences in incidence of signs and symptoms between the four groups before and after lens wear (Friedman tests, p > 0.07), data were combined for further analysis. Prior to lens wear, itchiness (69 %) and dryness (53 %) were the most commonly reported symptoms. The frequency and severity of all symptoms remained similar after lens wear (p > 0.10). Presence of follicles in the lower tarsal conjunctiva (22 %) and conjunctival injection (15 %) was frequently observed, but reduced significantly after lens wear (p < 0.01). Mild corneal staining, noted in 13 % of subjects at baseline, did not change significantly over time (p = 0.17). Ocular signs were not necessarily reflected in symptoms and vice versa.ConclusionUse of a PI-based solution did not increase the frequency or severity of ocular signs and symptoms observed before lens wear. Absence of a difference in occurrence of ocular discomfort with respect to cleaning regimes indicated that the use of the PI-based solution may adequately clean the lenses over a 6-month period. 相似文献
7.
《Contact lens & anterior eye》2019,42(2):165-169
ObjectiveTo introduce a new approach to simulatethe fitting process of rigid gas-permeable (RGP) contact lenses using 3D printing technology.MethodsA hemispherical or parabolic 3D model was created using 3D Builder or Tinkercad software. The horizontal and vertical diameters and the hemispherical or ellipsoid height were adjusted to simulate different morphologies of the corneal anterior surface. After exporting the file in stereo lithography (STL) format, a solid model was printed using a 3D printer and was used to simulate RGP contact lens fitting.ResultsLimited by the precision of the entry-level 3D printer which was used in this study, the print-outs of the corneal models were crude, but the models were tested for their ability to simulate common corneal morphologies with no corneal astigmatism and different axial corneal astigmatism. Compared with some built-in simulation programs for corneal topography, the solid models generated by 3D printing could well simulate the positioning of the lens under the influence of gravity and the eyelid, as well as lens eccentricity or the bubbles under lenses caused by an improper wearing method.Conclusion3D printing technology can be well applied in the simulation of RGP contact lens fitting, which may become a new teaching method in optometry. 相似文献
8.
Introduction
Rigid gas permeable (RGP) contact lens wearers may experience episodes of lens fracture during handling. In this paper, we report the case of a keratoconic contact lens wearer whose lens fractured whilst being handled at sub-zero temperatures. Subsequent studies illustrate how PMMA and RGP contact lenses behave when exposed to sub-zero temperatures.Methods
Using a previously validated custom-built strain gauge we have measured the force required to invert RGP contact lenses (Fluroperm, DK30-DK151, PMMA and Aquasil; dioptric power −2.00DS) under different temperature conditions.Results
It was found that RGP lenses, frozen to −7 °C, required on average 15% less force to cause inversion than when stored at room temperature, regardless of material. It was also found that without due care, lenses of all materials fractured more easily after having been frozen, than lenses kept at room temperature. Fracture rates rose from 8% to 83% if lenses were stored wet (at −7 °C) as opposed to dry.Conclusion
The authors conclude that practitioners should consider inappropriate contact lens storage and handling as a possible reason for otherwise unexplained acute RGP contact lens fracture. 相似文献9.
《Contact lens & anterior eye》2022,45(6):101718
PurposeTo characterise changes in soft contact lens wearing habits during the COVID-19 pandemic.MethodsA detailed online questionnaire was circulated to individuals aged 40–70 years, during the period April to May 2021. Data sampling took place in the United Kingdom (UK), United States of America (USA), Netherlands, Germany, France, Spain and Italy. Only data pertaining to individuals who were soft contact lens wearers were included. Data were extracted for questions relating to contact lens wearing habits pre- and during the COVID-19 pandemic, and expectations for future lens wear beyond the pandemic.ResultsSeven-hundred and twenty-eight individuals were identified as soft contact lens wearers of which six-hundred and nineteen wore a combination of contact lenses and spectacles. Most respondents indicated contact lens wear times had either remained the same (57.3%) or increased (9.8%) during the pandemic. The country with the greatest proportion of respondents decreasing wear time during COVID-19 was the UK (45.3%), and the least in the Netherlands (20.0%). The primary cause of decreased lens wear was attributed to leaving the home less often (70.0%), and the second most common reason due to concerns about hygiene (10.8%). Most respondents (83.9%), however, expressed a desire to return to pre-pandemic wear times once the pandemic was over.ConclusionsPractitioner concerns about contact lens market recovery ought to be assuaged by the survey outcomes which show most individuals to have maintained lens wear during the pandemic. In view of the continued lens wear, as and when restrictions ease, ECPs may wish to encourage patients to return for routine check-ups that may have been missed due to the pandemic. 相似文献
10.
《Contact lens & anterior eye》2014,37(3):228-229
PurposeTo report a case of epithelial Herpes Simplex keratitis in a patient wearing daily disposable contact lenses.MethodCase report.ResultsA 30-year-old female contact lens wearer presented to the emergency clinic with a painful, red left eye associated with an acute reduction of vision over 48 h. On examination, confluent dendritic ulcers were present on the cornea. Neither pertinent ocular nor medical history was obtained to explain such a dramatic clinical presentation.ConclusionContact lens wear was the only risk factor identified, perhaps resulting in deviation of the immune response at the ocular surface, with consequent extensive dendritic ulceration. 相似文献
11.
12.
Luigina Sorbara Jyotsna Maram Trefford Simpson Natalie Hutchings 《Contact lens & anterior eye》2018,41(2):193-200
Purpose
First, to examine how wearing high and low modulus lenses with two different base curves affected lens fit, and the corneal tissue and bulbar conjunctival vascular tissue (bulbar redness and blood velocity). Secondly, to quantify the associations between these baseline and outcome variables and the third purpose was to correlate these variables with end of day comfort.Methods
Thirty participants wore higher (PureVision (PV) 8.3, 8.6) and lower (Acuvue Advance (AA) 8.3, 8.7) modulus silicone hydrogel lenses for two weeks on a daily wear basis. Lens fitting characteristics were examined. Corneal epithelial thickness was measured and the cornea and conjunctiva were assessed. RBC velocity was estimated from high magnification bulbar conjunctival images. Subjective comfort/dryness was reported by participants using visual analogue scales.Results
AA lenses were rated the most comfortable (ANOVA, p = 0.041). The least movement was while using the AA 8.3 base curve lens (Tukey p = 0.028). Steep AA and PV lenses showed significantly higher conjunctival staining at the 2 week visit (ANOVA, p = 0.029). There was a significant decrease in RBC velocity with both steeper AA lenses vs PV lenses (Tukey, p = 0.001). Comparing baseline and 2 week visits, there was a significant negative correlation for the PV 8.3 between comfort and superior bulbar staining (r = ?0.53). For both the PV 8.3 and AA 8.3 reduced RBC velocity was correlated with dryness (r = 0.61 and r = 0.91, respectively).Conclusions
Physical differences in contact lenses affect structural and vascular functional aspects of the ocular surface and these may be associated with symptoms of dryness. 相似文献13.
《Contact lens & anterior eye》2020,43(5):476-483
PurposeTo investigate ocular discomfort during contact lens wear using a wrist-mounted electronic ‘lens awareness logger’ (LAL).MethodsThirty symptomatic contact lens wearers wore study contact lenses for three days. On the first two days, two lens types which are known to differ in end-of-day comfort (lens A: senofilcon A and lens B: balafilcon A), were worn as a matching pair (randomised order). On day three, a pair of lens B was worn. On each day, the participant used a LAL. On day one and two, the participant pressed a button on the LAL whenever they became aware of their lenses due to discomfort. On day three, the participant used a multiple click protocol (1 = mild awareness to 3 = severe awareness) to report discomfort.ResultsLAL events were similar on days one and two (17.3 vs. 15.8 events per day). There were significantly more LAL events for lens B (21.6 events per day) in comparison with lens A (11.6 events per day) (p = 0.006). The LAL event profile highlighted peaks in awareness following lens application and towards the end of the wearing cycle. Comparison of the LAL event profile for the two lens types showed significant differences in lens awareness, particularly in the first half of the wearing cycle. LAL events on day 3, showed a uniform distribution of single and double clicks through the day, but a marked peak in triple clicks in the last two hours of lens wear.ConclusionThe LAL was able to differentiate between the study lenses and demonstrated differences in their LAL event profiles. Lens awareness associated with discomfort appeared to increase not only in frequency, but also in intensity towards the end of the wearing cycle. The ability of the LAL to track lens awareness suggests it is likely to be a useful tool in furthering understanding of ocular discomfort. 相似文献
14.
《Contact lens & anterior eye》2019,42(6):646-651
PurposeTo evaluate meibomian gland (MG) width and determine its impact on successful contact lens (CL) use and ocular health.MethodsA five-site study was conducted by recruiting 18- to 45-year-old subjects who had dropped out of CLs because of discomfort. CL dropouts were compared to age- and sex-matched successful CL wearers. Right eyes were evaluated for tear break-up time, tear meniscus height, MG expressibility, meibum quality, and meibography. Central MG widths were evaluated with a custom MATLAB program.ResultsCL dropouts (n = 56) and successful CL (n = 56) wearers had similar grades for upper (p = 1.0) and lower (p = 0.22) MG atrophy, upper (p = 0.07) and lower (p = 0.89) MG tortuosity, and upper (p = 0.92) and lower (p = 0.97) MG widths. Upper eyelid MG widths were narrower than lower eyelid MG widths (p = 0.03). Upper and lower MG tortuosity (p < 0.001) and widths (p = 0.03) were associated, but not atrophy (p = 0.42). Lower eyelid MG widths were associated with MG expressibility (p = 0.01), but MG widths were not with any other factors.ConclusionsSuccessful CL wear does not appear to be clinically influenced by MG width or other measures of MG structural integrity. Lower eyelid MGs were wider than upper eyelid MGs and narrower lower eyelid MGs were associated with worse MG expressibility, suggesting that narrower MGs may produce abnormal meibum. Data also suggests that MG factors of both eyelids should be evaluated in practice. 相似文献
15.
《Contact lens & anterior eye》2022,45(5):101519
PurposeTo determine (1) the factors associated with a high degree of self-reported symptoms with Japanese translations of the 8-Item Contact Lens Dry Eye Questionnaire (J-CLDEQ-8) in a cross-section of soft contact lens (SCL) wearers in Japan and (2) whether the difference in translation of the CLDEQ-8 affects the scores between validated and non-validated versions of the Japanese translation.MethodsHabitual SCL wearers completed the validated J-CLDEQ-8 and a previous non-validated version. Demographics and SCL history questions were queried when they presented for routine eye care in nine geographically distinct clinics across Japan. The following risk factors for high J-CLDEQ-8 scores (≥11) were tested: sex, age, SCL replacement (daily disposable vs. bi-weekly and monthly reusable), years of SCL wear, and self-reported use of rewetting drops. The scores of the validated and non-validated questionnaires were compared.ResultsSignificant patient-related risk factors for high J-CLDEQ-8 scores were female sex, use of reusable SCLs, longer years of SCL wear, and use of rewetting drops. Scores for six out of eight questions in the validated J-CLDEQ-8 were significantly higher than those of the non-validated version, resulting in a significant difference in the average total score between the two questionnaires (validated J-CLDEQ-8: 10.5 ± 5.9 vs non-validated J-CLDEQ-8: 9.5 ± 5.8, P < 0.001).ConclusionsFemale sex, use of reusable SCLs, longer years of SCL wear, and use of rewetting drops were significant risk factors for high J-CLDEQ-8 scores in a cross-sectional clinical population of Japanese SCL wearers. Symptoms with SCL are not predicted by age and must therefore be queried at follow-up visits for all SCL wearers. Differences in the two translations affected the ability of the questionnaire to identify individuals with high symptoms associated with SCL wear. 相似文献
16.
Motohiro Itoi Motozumi Itoi Nathan Efron Philip Morgan Craig Woods 《Contact lens & anterior eye》2018,41(4):369-376
Purpose
To review contact lens prescribing trends in Japan between 2003 and 2016.Methods
An annual survey of contact lens prescribing trends was conducted each year between 2003 and 2016. Japanese ophthalmologists were asked to provide information relating to ten consecutive contact lens fittings between January and March every year.Results
Over the 14 years of the annual survey, data from a total of 64,122 contact lens fits were returned by ophthalmologists. The mean age (±SD) of lens wearers was 30?±?13?years, and 68% were female. The proportion of rigid lens fits decreased over time, from 35.4% in 2003 to 14.7% in 2016. Across this period, daily disposable lens fits increased, representing 46% in 2016. The proportion of toric lenses and multifocal lenses gradually increased, from 6.6% and 1.9% to 12.3% and 5.8%, respectively. Silicone hydrogel material use grew from 0% to 43.2%, while mid and low water content lens materials declined from 54.1% and 28.2% to 36.1% and 8.3%, respectively. Multi-purpose lens care solutions dominated the market over the 14?year survey period.Conclusions
This survey has revealed prescribing trends and preferences in Japan over the past 14 years, with the main changes observed being a decrease in rigid lens use and an increase in the use of silicone hydrogel materials and daily disposable lenses. 相似文献17.
《Contact lens & anterior eye》2019,42(1):28-35
PurposeTo compare three methods to measure central corneal clearance (CCC) during scleral lens wear: subjective (slit lamp), image processed (ImageJ) and with an optic biometer. The optic biometer technique was validated in comparison to an OCT in the first part of the study.MethodsTwenty-two eyes (11 subjects) with healthy corneas were recruited. Three measures of OCT with scleral lens and ten measurements of axial length (AL) with IOLMaster with and without lens were performed. For the second part, 61 eyes (35 subjects) enrolled in a clinical study were selected. Measurements of CCC were done with IOLMaster, SlitLamp and ImageJ.ResultsThe measurements of CCC indirectly obtained with IOLMaster had a strong correlation with AS-OCT measurements (r = 0.981), showing a mean difference of 122.18 ± 46.05 μm (higher with IOLMaster). Regarding the second part, measurements of CCC were 238.66 ± 95.94 μm, 250.16 ± 124.31 μm and 263.15 ± 90.60 μm, for the IOLMaster, SlitLamp and ImageJ, respectively. The correlations were higher for ImageJ vs Subjective measure (r = 0.891) than for IOL vs Subjective (r = 0.748) and IOL vs ImageJ (r = 0.745). Analysis of differences and correlations between SlitLamp and ImageJ through time showed a mean difference of -32.28 ± 89.95 μm (r = 0.683) at V1month, 12.53 ± 59.46 μm (r = 0.850) at V6months and 11.57 ± 32.95 μm (r = 0.940) at V12months.ConclusionsIt is possible to measure CCC with IOLMaster, considering AL measured with and without lens and lens thickness. The three methods tested have good correspondence, showing that IOLMaster and ImageJ could be objective techniques to measure CCC. Also, it is possible to improve the agreement of subjective measures when compared to objective measures trough time. 相似文献
18.
19.
《Contact lens & anterior eye》2014,37(1):16-19
PurposeThe purpose of this study was to evaluate the complexity and effectiveness of fitting bitoric rigid gas permeable contact lenses (RGPCLs), compared to spherical RGPCLS, when used in the correction of high amounts of post-penetrating keratoplasty astigmatism.MethodsRecords of post-penetrating keratoplasty (PKP) patients being managed with bitoric RGPCLs were compared to controls (post-PKP patients managed with spherical RGPCLs). Factors that were analyzed included the number of diagnostic RGPCLs used to assess the initial fit, the number of RGPCLs ordered to finalize the fit and the number of total doctor visits to finalize the fit.ResultsFourteen eyes of 14 patients satisfied the study criteria. The average amount of total astigmatism in this study group was 10.0 D ± 5.0 compared to the control group which was 3.3 D ± 2.6. The number of diagnostic RGPCLs used for the study group was 1.2 ± 0.4 compared to 1.0 ± 0.0 for the control group. The mean number of contact lenses ordered to complete the fitting for the study group was 1.9 ± 0.7 compared to the control which was 2.1 ± 0.8. The study group presented for an average of 6.3 ± 1.6 visits whereas the control group presented for 4.9 ± 1.1 visits. Contact lens corrected acuity for the study group was 0.101 ± 0.11 (20/25) compared to the control group 0.08 ± 0.12 (20/24).ConclusionsThe complexity of fitting bitoric RGPCLs was found to be similar to fitting spherical RGPCLs on post-PKP eyes and the visual outcomes were not different. 相似文献
20.
《Contact lens & anterior eye》2022,45(3):101446
PurposeTo document contact lens prescribing trends in the United Kingdom over the past quarter of a century.MethodsAn annual survey of contact lens prescribing was conducted each year from 1996 to 2020, inclusive, by asking a random selection of optometrists and contact lens opticians to provide information relating to 10 consecutive contact lens fits between January and March.ResultsOver the 25 year survey period, 2,671 practitioners returned survey forms, reporting a total of 25,575 contact lens fits. The mean (± standard deviation) age of lens wearers was 35 ± 15 years, of which 64 % were female. Over the survey period, rigid lens new fits decreased from 22 % to 2%. The prescribing of silicone hydrogel lenses has increased steadily since their introduction towards the end of the 1990s, and now represent 80 % of soft lens fits. Soft toric lens prescribing has gradually increased to 47 % – a value at which astigmatism ≥ 0.75DC is theoretically corrected in all contact lens wearers. Daily disposable prescribing increased steadily over the survey period and now represents 63 % of lenses prescribed. Extended wear fits remain at very low levels, except for some prescribing for overnight orthokeratology. Multi-purpose lens care solutions are ubiquitous; peroxide and other systems are now seldom prescribed. Rigid lenses and monthly replacement soft lenses are predominantly worn on a full time basis, whereas daily disposable soft lenses are mainly worn part time.ConclusionsThis report documents the evolution of contact lens fitting in the United Kingdom over the past 25 years. The most likely lens fit is a spherical design silicone hydrogel daily disposable contact lens prescribed for a 35 year old female and worn on a part-time basis. 相似文献