首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe a new method for focusing and concentrating a stream of moving micron-sized aerosol particles in air. The focusing and concentrating process is carried out by the combined drag force and optical force that is generated by a double-layer co-axial nozzle and a focused doughnut-shaped hollow laser beam, respectively. This method should supply a new tool for aerosol science and related research.

Copyright © 2018 American Association for Aerosol Research  相似文献   


2.
Accurate exposure assessments are needed to evaluate health hazards caused by airborne microorganisms and require air samplers that efficiently capture representative samples. This highlights the need for samplers with well-defined performance characteristics. While generic aerosol performance measurements are fundamental to evaluate/compare samplers, the added complexity caused by the diversity of microorganisms, especially in combination with cultivation-based analysis methods, may render such measurements inadequate to assess suitability for bioaerosols. Specific performance measurements that take into account the end-to-end sampling process, targeted bioaerosol and analysis method could help guide selection of air samplers.

Nine different samplers (impactors/impingers/cyclones/ electrostatic precipitators/filtration samplers) were subjected to comparative performance testing in this work. Their end-to-end cultivation-based biological sampling efficiencies (BSEs) and PCR-/microscopy-based physical sampling efficiencies (PSEs) relative to a reference sampler (BioSampler) were determined for gram-negative and gram-positive vegetative bacteria, bacterial spores, and viruses.

Significant differences were revealed among the samplers and shown to depend on the bioaerosol's stress–sensitivity and particle size. Samplers employing dry collection had lower BSEs for stress-sensitive bioaerosols than wet collection methods, while nonfilter-based samplers showed reduced PSEs for 1 μm compared to 4 μm bioaerosols. Several samplers were shown to underestimate bioaerosol concentration levels relative to the BioSampler due to having lower sampling efficiencies, although they generally obtained samples that were more concentrated due to having higher concentration factors.

Our work may help increase user awareness about important performance criteria for bioaerosol sampling, which could contribute to methodological harmonization/standardization and result in more reliable exposure assessments for airborne pathogens and other bioaerosols of interest.

Copyright 2014 American Association for Aerosol Research  相似文献   


3.
The Fifth Annual Conference on Flame Retardancy was held May 24–26, 1994, at the Ramada Plaza Hotel, Stamford, Connecticut, USA. The conference was organized by Business Communications Company, Inc., Norwalk, Connecticut (Company President, Mr. Louis Naturman; Conference Coordinator, Mrs. Sharon D. Faust). New materials (polymers, blends, composites), their applications, industry developments, and markets were considered. Specifically, the most important topics were:

Introduction of new technological achievements and development in the field of flame retardancy (FR)

Review of the current state of science and technology in FR

Review of applications and markets for FR products

Presentation of recent developments in local and global standardization and in testing technology

Discussion of toxicity and environmental issues

Provision of a unique opportunity for newcomers to FR research technology and marketing to become acquainted with the FR field in all its aspects

Discussion of halogen-based and non-halogen-based flame retardant chemicals, syngergism, intumescence, FR mechanisms, modeling, flame parameters, inherently FR polymers, and polymer blends  相似文献   


4.
Detection of bioaerosols is important in fields ranging from environmental health monitoring to biosurveillance, and current detector weaknesses have motivated the development of new technologies. In this work, a detector was built, which applies the principles of droplet microfluidics to bioaerosol detection. Droplet microfluidics is a subfield of microfluidics based on the creation of monodisperse microdroplets with compartmentalized reagents and supports enhanced assays and fluidic manipulations. The bioaerosol detector operates by aerodynamically focusing aerosols directly into these droplets to harness the benefits of the microreactor environment. A breadboard detector system, which consisted of an aerodynamic focusing lens, aerosol-focusing capillary, microfluidic droplet chip, and optical microscope, was constructed. Computational fluid dynamic simulations and Lagrangian particle tracking modeling were conducted to identify the optimal conditions for focusing. Preliminary experiments, where aerosols were deposited onto a solid substrate, demonstrated sub 200-µm spot diameters for aerodynamic diameters of 2–5 µm. Test aerosols were then generated, and collected into the microfluidic liquid interface on the chip as verified by microscopy. Recovery efficiency of the aerosols was dependent on aerosol size and ranged from about 27% to nearly 100%. Finally, to prove bioaerosol collection and detection, a droplet propidium iodide (PI) assay was performed: the system distinguished between E. coli and non-biological aerosols within 20 s. Overall, this work established the technique of direct collection of bioaerosols into a convenient droplet microfluidic platform for detection.

Copyright © 2017 The Johns Hopkins University Applied Physics Laboratory  相似文献   


5.
To address the critical need for improving the chemical characterization of the organic composition of ambient particulate matter, we introduce a combined thermal desorption aerosol gas chromatograph—aerosol mass spectrometer (TAG-AMS). The TAG system provides in-situ speciation of organic chemicals in ambient aerosol particles with hourly time resolution for marker compounds indicative of sources and transformation processes. However, by itself the TAG cannot separate by particle size and it typically speciates and quantifies only a fraction of the organic aerosol (OA) mass. The AMS is a real-time, in-situ instrument that provides quantitative size distributions and mass loadings for ambient fine OA and major inorganic fractions; however, by itself the AMS has limited ability for identification of individual organic compounds due to the electron impact ionization detection scheme used without prior molecular separation.

The combined TAG-AMS system provides real-time detection by AMS followed by semicontinuous analysis of the TAG sample that was acquired during AMS operation, achieving simultaneous and complementary measurements of quantitative organic mass loading and detailed organic speciation. We have employed a high-resolution time-of-flight mass spectrometer (HR-ToF-MS) to enable elemental-level determination of OA oxidation state as measured on the AMS, and to allow improved compound identification and separation of unresolved complex mixtures (UCM) measured on the TAG. The TAG-AMS interface has been developed as an upgrade for existing AMS systems. Such measurements will improve the identification of organic constituents of ambient aerosol and contribute to the ability of atmospheric chemistry models to predict ambient aerosol composition and loadings.

Copyright 2014 American Association for Aerosol Research  相似文献   


6.
Conventional methods for total dust sampling from industrial high-temperature aerosols containing condensable species, e.g., in boilers of municipal solid waste incinerators (MSWI), are always influenced by condensation artifacts. Therefore, we extended the scope of a previously developed probe intended for size-fractionated aerosol sampling with reduced artifacts and employed it for total dust measurements. The dust is collected on quartz fiber filters, which are gravimetrically evaluated and chemically analyzed by energy dispersive X-ray spectroscopy and wet-chemical methods. First measurements in the boiler of an MSWI confirm that the probe is also suitable for artifact-minimized total dust sampling. The data are consistent with results from measurements with the size-fractionating method conducted in parallel. By combining the results of both sampling methods, we reveal the average chemical composition of the submicron particles in the aerosol, which is not accessible by one of the two methods alone.

© 2017 American Association for Aerosol Research  相似文献   


7.
A new experimental technique is reported to visualize agglomeration of submicron aerosol particles by laser-induced fluorescence (LIF). The basic idea is to produce or activate the fluorescent tracer material by a chemical reaction triggered by the agglomeration between two chemically different primary particles. Different types of chemical reactions are able to fulfil this task, among others acid–base reactions or molecule solvation. In this work, we demonstrate the feasibility of the fluorescent tracer activation by means of solvation. The fluorescence is activated almost instantaneously when the dry fluorescent material (Fluorescein or Rhodamine B) contained in the dye aerosol is dissolved by a water/glycerol mixture constituting the particles of the solvent aerosol. Estimations of the timescale for diffusional mixing suggest that the fluorescence is activated within 1 ms. Agglomerates can be detected as single particles or in bulk quantities depending on the available laser excitation energy and light sensitivity. In order to enhance agglomeration in the validation experiments, two aerosol streams were electrostatically charged with opposite polarity. Finally, potential variations and applications of the newly introduced technique are briefly discussed, mentioning the detection of humidity among others.

© 2017 American Association for Aerosol Research  相似文献   


8.
Accurate refractive index values are required to determine the effects of aerosol particles on direct radiative forcing. Theoretical retrievals using extinction data alone or extinction plus absorption data have been simulated to determine the sensitivity of each retrieval. A range of aerosol types with a range of different refractive indices were considered. The simulations showed that the extinction-only retrieval was not able to accurately or precisely retrieve refractive index values, even for purely scattering compounds, but the addition of a simulated absorption measurement greatly improved the retrieval.

Copyright 2014 American Association for Aerosol Research  相似文献   


9.
We introduce a new electrical measurement technique for aerosol detection, based on pulsed unipolar charging followed by a non-contact measurement of the rate of change of the aerosol space charge in a Faraday cage. This technique, which we call “aerosol measurement with induced currents,” has some advantages compared to the traditional method of collecting the charged particles on either an electrode or with a particle filter. We describe the method and illustrate it with a simple and miniature (shirt-pocket-sized) instrument to measure lung-deposited surface area. Aerosol measurement by induced currents can also be applied to more complex devices.

Copyright 2014 American Association for Aerosol Research  相似文献   


10.
The field of performance plastics is showing remarkable vitality and growth, even though the participants find the price to be high in terms of technical and sales support required, together with high capital investment for plants.

There has been a high degree of proliferation of new products in the form of new polymers, new grades of existing polymers, as well as filled, reinforced, alloyed versions. While this does introduce new degrees of freedom in material selection, it is a source of significant confusion for the design engineers who have to cope with selecting the preferred material from among the many that are available. The choices and data bases are becoming confusing.

Various forms of relatively exotic, aromatic-monomer chemistry are being applied, but the emphasis appears to be on new amorphous polymers.

High-performance requirements exist in virtually all segments of the plastics field; the major end uses are in aerospace, automotive, business machines, electrical/electronics, food packaging, and medical applications.

Foreign presence has strongly increased as European companies have increased imports or have purchased established product lines or business units.

There will be continued pressure on the performance plastics from the lower priced materials which are countering with upgraded, modified, alloyed versions of their own. There is also increased competition between thermoplastics and thermosets as the result of material developments and process refinements.  相似文献   


11.
In situ atmospheric aerosol measurements have been performed from a Manta unmanned aircraft system (UAS) using recently developed miniaturized aerosol instruments. Flights were conducted up to an altitude of 3000 m (AMSL) during spring 2015 in Ny-Ålesund, Svalbard, Norway. We use these flights to demonstrate a practical set of miniaturized instruments that can be deployed onboard small UASs and can provide valuable information on ambient aerosol. Measured properties include size-resolved particle number concentrations, aerosol absorption coefficient, relative humidity, and direct sun intensity. From these parameters, it is possible to derive a comprehensive set of aerosol optical properties: aerosol optical depth, single scattering albedo, and asymmetry parameter. The combination of instruments also allows us to determine the aerosol hygroscopicity.

Copyright © 2017 American Association for Aerosol Research  相似文献   


12.
The quality of water provided by the Budapest Waterworks should comply with the standards prescribed by the European Community. According to these provisions, on one of the major water-producing regions (Csepel Island), rows of wells of 60,000 m3/day yield have been closed recently, and in the immediate future further plants would have been closed because of the high iron and manganese content of the water.

The raw water obtained from 100 different wells will be purified by a water treatment plant of 150,000 m3/day capacity. Considering the high iron content (0.05–0.15 mg/L) and manganese content (0.05–0.2 mg/L), the raw water fails to comply with the requirements of the potable water standard.

Since 1990, over a period of three years, we conducted water purification experiments in several stages. In these, three methods of oxidizing as well as single and double layer open rapid filters were applied to oxidize the manganese (and, to a lesser extent, the water) present in dissolved form, resp., to destroy various living organisms.

In the course of the experiments, it became clear that the chlorine and chlorine + air methods are efficient in case of a small quantity of iron to be oxidized and only 20–25% of the dissolved manganese content could be oxidized.

Neither of the two methods could ensure firm management of microbiological and bacteriological characteristics. The best results were obtained by ozone oxidation, in which case the chemical oxidizing process was almost fully completed and even the chlorine-resistant living organisms could be destroyed.

On the basis of the experiments carried out, the investment program of the water treatment plant was worked out and the conditions of an international tender were compiled whose winner will be commissioned to build up the water works in the time period 1993–1996. One of the main steps of the proposed technology is the ozone treatment.  相似文献   


13.
It is currently admitted that for each filtration process using pleated filters, at least three steps can be distinguished: depth and surface filtration, which are common to flat filters, and surface reduction. This step is caused by inefficient filling of the pleat due to the filter geometry. For combustion aerosol, it has been proved that this third step strongly depends on the filtration velocity resulting in an increase of the resistance when air flow decreases. This observation leads one to think that Brownian diffusion, higher for low velocities, could influence the clogging dynamic of a pleated filter.

In this article, a protocol derived from the dust cake preparation method published by Schmidt is developed. The aim of this study is to measure the aerosol penetration inside a filter media as well as in a pleat using a scanning electronic microscope and energy dispersive X-ray spectroscopy elementary detection. This method has also been extended to the study of pleated filters to measure the particle distribution inside the pleat. Filters were loaded with nanoparticles in order to evaluate the specificity of the diffusional regime on the clogging of pleated HEPA filters. For pleated filters, two filtration velocities were investigated: 2.5 and 0.2 cm/s.

Copyright 2014 American Association for Aerosol Research  相似文献   


14.
The problem of large pressure-differential-driven laminar convective–diffusive ultrafine aerosol flow through bent microtubes is of interest in several contemporary research areas including; release of contents from pressurized containment vessels, aerosol sampling equipment, advanced scientific instruments, gas-phase microheat exchangers, and microfluidic devices. In each of these areas, the predominant problem is the determination of the fraction of particles entering the microtube that is deposited within the tube and the fraction that is transmitted through. Due to the extensive parameter restrictions of this class of problems, a Lagrangian particle tracking method making use of the coupling of the analytical stream line solutions of Dean for convective motion and a sampling of a Gaussian distribution for diffusive motion is a useful tool in problem characterization. This method is a direct analog to the Monte Carlo N-Particle method of particle transport extensively used in nuclear physics and engineering. In this work, 10-nm-diameter particles with a density of 1 g/cm3 are tracked within microtubes with toroidal bends with pressure differentials ranging between 0.2175 and 0.87 atmospheres. The tubes have radii of 25 microns or 50 microns and the radius of curvature is either 1 m or 0.3183 cm. The carrier gas is helium, and temperatures of 298 K and 558 K are considered. Numerical convergence is considered as a function of time step size and of the number of particles per simulation. Particle transmission rates and deposition patterns within the bent microtubes are calculated.

Copyright © 2016 American Association for Aerosol Research  相似文献   


15.
The article presents a mathematical model for calculation of nonstationary hydraulic and separation processes in a gas centrifuge (GC) cascade for separation of multicomponent isotope mixtures. The model has been applied to calculate the parameters of nonstationary processes in a GC cascade for separation of krypton, germanium and tungsten isotopes. As a result, the specifics of the excess holdup distribution along the cascade stages has been identified, and variations of the isotope concentrations in a nonstationary process have been revealed. The data obtained show that the proposed mathematical model is able to adequately describe nonstationary hydraulic processes in GC cascades for separation of multicomponent isotope mixtures.

Highlights:

Mathematical model of cascade for separation of multicomponent isotope mixture has been developed.

The model verification has been done.

The isotope transient regularities into cascade during nonstationary processes has been identified.  相似文献   


16.
Accurate development and evaluation of inlets for representatively collecting ambient particulate matter typically involves the use of monodisperse particles in aerosol wind tunnels. However, the resource requirements of using monodisperse aerosols for inlet evaluation creates the need for more rapid and less-expensive techniques to enable determination of size-selective performance in aerosol wind tunnels. The goal of recent wind tunnel research at the U.S. EPA was to develop and validate the use of polydisperse aerosols, which provide more rapid, less resource-intensive test results, which still meet data quality requirements necessary for developing and evaluating ambient aerosol inlets. This goal was successfully achieved through comprehensive efforts regarding polydisperse aerosol generation, dispersion, collection, extraction, and analysis over a wide range of aerodynamic particle sizes. Using proper experimental techniques, a sampler’s complete size-selective efficiency curve can be estimated with polydisperse aerosols in a single test, as opposed to the use of monodisperse aerosols, which require conducting multiple tests using several different particle sizes. While this polydisperse aerosol technique is not proposed as a regulatory substitute for use of monodisperse aerosols, the use of polydisperse aerosols is advantageous during an inlet’s development where variables of sampling flow rate and inlet geometry are often iteratively evaluated before a final inlet design can be successfully achieved. Complete Standard Operating Procedures for the generation, collection, and analysis of polydisperse calibration aerosols are available from EPA as downloadable files. The described experimental methods will be of value to other researchers during the development of ambient sampling inlets and size-selective evaluation of the inlets in aerosol wind tunnels.

© 2018 American Association for Aerosol Research  相似文献   


17.
The conventional blown process imparts an inherent haze to the product. The percentage of haze varies with certain process variables:

1. Surface irregularities caused by melt flow phenomena

2. Crystallization behavior

3. Melt drawing phenomena in certain types of polyethylene  相似文献   


18.
19.
This work presents the development and characterization of a thermodenuder for the study and interpretation of aerosol volatility. Thermodenuder measurements are further combined with a continuous-flow streamwise thermal gradient CCN counter to obtain the corresponding aerosol hygroscopicity. The thermodenuder response function is characterized with monodisperse aerosol of variable volatility and hygroscopicity. The measurements are then interpreted with a comprehensive instrument model embedded within an optimization framework to retrieve aerosol properties with constrained uncertainty. Special attention is given to the interpretation of the size distribution of the thermodenuded aerosol, deconvoluting the effects of impurities and multiple charging, and to simplifications on the treatment of thermodenuder geometry, temperature, the cooling section, and the effects of curvature and accommodation coefficient on inferred particle volatility. Retrieved vapor pressures are consistent with published literature and shown to be most sensitive to uncertainty in the accommodation coefficient.

Copyright 2014 American Association for Aerosol Research  相似文献   


20.
The use of inlets for transferring aerosols from the environment to instrumentation can introduce uncertainty in the measurement of aerosol properties. Aerosol loss during this process is a non-negligible issue that may bias the subsequent measurements. These loss mechanisms include aspiration at the inlet head and deposition/evaporation/condensation during transport through the sampling lines. Coarse-mode aerosol is significantly impacted by the aspiration and inertial loss mechanisms within an inlet system. This work uses wind tunnel experiments to investigate aerosol losses through the Storm Peak Laboratory’s (SPL) new aerosol inlet system. The inlet is used extensively for both intensive field campaigns and long-term aerosol monitoring. The results of numerical simulations of the SPL aerosol inlet sampling efficiency are provided at several wind speeds, and experimental results demonstrate the system has a 50% cut off for the coarse-mode at an aerodynamic diameter of approximately 13?μm and wind speed of 0.5?m s?1. This investigation will lead to improved accuracy of in situ aerosol measurements at SPL and this system can be replicated at other atmospheric stations.

Copyright © 2019 American Association for Aerosol Research  相似文献   