共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Ramoino P Usai C Beltrame F Fato M Gallus L Tagliafierro G Magrassi R Diaspro A 《Microscopy research and technique》2005,68(5):290-295
The number of neurotransmitter receptors on the plasma membrane is regulated by the traffic of intracellular vesicles. Golgi-derived vesicles provide newly synthesized receptors to the cell surface, whereas clathrin-coated vesicles are the initial vehicles for sequestration of surface receptors, which are ultimately degraded or recycled. We have previously shown that GABAB receptors display a punctuate vesicular pattern dispersed on the cell surface and throughout the cytoplasm and are internalized via clathrin-dependent and -independent endocytosis. Here we have studied constitutive GABAB receptor trafficking after internalization in Paramecium primaurelia by confocal laser scanning microscopy and multiple immunofluorescence analysis. After internalization, receptors are targeted to the early endosomes characterized by the molecular markers EEA1 and rab5. Some of these receptors, destined for recycling back to the plasma membrane, traffic from the early endosomes to the endosomal recycling compartment that is characterized by the presence of rab4-immunoreactivity (IR). Receptors that are destined for degradation exit the endosomal pathway at the early endosomes and traffic to the late endosome-lysosome pathway. In fact, some of the GABAB-positive compartments were identified as lysosomal structures by double staining with the lysosomal marker LAMP-1. GABAB vesicle structures also colocalize with TGN38-IR and rab11-IR. TGN38 and rab11 are proteins found in association with post-Golgi and recycling endosomes, respectively. 相似文献
3.
The illumination source for all high-resolution, optical sectioning, scanning microscopes is crucially important to the overall performance of the system. We examine advances that have been made in laser sources for both confocal and multiphoton microscopy where the emphasis has been on the development of potentially low-cost, easy to use sources. Growing interest in temporally and spatially resolved techniques has directed laser research towards addressing these challenges. We present the most recent developments in sources for confocal and multiphoton microscopy along with the considerations that should be made when a new source is being considered. 相似文献
4.
介绍了拉曼光谱仪采用的共焦显微术的广泛应用;叙述了真共焦显微术的基本原理和优点,以及简单共焦(即“赝共焦”)显微术的主要缺点;列出了有关实验结果及数据对比。 相似文献
5.
Wright AJ Burns D Patterson BA Poland SP Valentine GJ Girkin JM 《Microscopy research and technique》2005,67(1):36-44
We report on the introduction of active optical elements into confocal and multiphoton microscopes in order to reduce the sample-induced aberration. Using a flexible membrane mirror as the active element, the beam entering the rear of the microscope objective is altered to produce the smallest point spread function once it is brought to a focus inside the sample. The conventional approach to adaptive optics, commonly used in astronomy, is to utilise a wavefront sensor to determine the required mirror shape. We have developed a technique that uses optimisation algorithms to improve the returned signal without the use of a wavefront sensor. We have investigated a number of possible optimisation methods, covering hill climbing, genetic algorithms, and more random search methods. The system has demonstrated a significant enhancement in the axial resolution of a confocal microscope when imaging at depth within a sample. We discuss the trade-offs of the various approaches adopted, comparing speed with resolution enhancement. 相似文献
6.
We describe a simple method to produce an arbitrary complex optical field using a ferroelectric liquid crystal spatial light modulator. The system is configured so as to act as a pupil plane filter in a confocal microscope. The ability to tune the complex pupil function permits the system to be used both to modify the imaging performance by effectively engineering the point spread function as well as to remove optical aberrations present in the optical system. 相似文献
7.
The initial results of the first dedicated confocal scanning laser microscopy (CSLM) study of fluid inclusions in quartz are presented. CSLM imaging of a large inclusion shows the quartz crystal to contain numerous small (< 1 μm), highly reflective inclusions arranged along planes in at least two directions that are not readily visible in transmitted light. The technique allows measurements to be made of the angular intersection and orientation of the planes in both two and three dimensions. Results suggest that larger inclusions (> 10 μm) occur where two planes of small inclusions intersect, and that the shape of the large inclusions is controlled by the angular relationship between intersecting planes. 相似文献
8.
One potential application of tandem scanning confocal microscopy is the detection of in vivo pathogens. Our study of an experimental model of Acanthamoeba keratitis demonstrates that while this technology can successfully detect certain organisms, there are currently limitations. These limitations relate to instrument configuration, movement of either the tissue or the microscope, difficulty in reproducibly returning to the area of interest for serial examination, the lack of a distinctive morphology of some pathogens, and limited resolution of the microscope. 相似文献
9.
Al-Nawas B Grotz KA Götz H Heinrich G Rippin TG Stender TE Duschner H Wagner W 《Scanning》2001,23(4):227-231
10.
We compare the axial sectioning capability of multifocal confocal and multifocal multiphoton microscopy in theory and in experiment, with particular emphasis on the background arising from the cross‐talk between adjacent imaging channels. We demonstrate that a time‐multiplexed non‐linear excitation microscope exhibits significantly less background and therefore a superior axial resolution as compared to a multifocal single‐photon confocal system. The background becomes irrelevant for thin (< 15 µm) and sparse fluorescent samples, in which case the confocal parallelized system exhibits similar or slightly better sectioning behaviour due to its shorter excitation wavelength. Theoretical and experimental axial responses of practically implemented microscopes are given. 相似文献
11.
A new noninvasive microscopic technique of three-dimensional optical biopsy from in vivo human skin based on real-time confocal microscopy and computer reconstruction is demonstrated. A tandem scanning confocal microscope is a prototype of a mobile, flexible design for the in-depth microscopic exploration of the skin on the human body. The various skin layers were observed in real-time, at the subcellular level down to a depth of 200 μm with a vertical resolution of 2 μm. Rapid video recording of the Z-series through the ventral aspect of the forearm avoided shifts caused by subject movement and blood flow pulsations. Two video frames were averaged, and the average was digitized, providing a stack of 64 optical sections in 1-μm vertical steps. Three-dimensional reconstructions of in vivo human skin were obtained with sets of orthogonal slices, and slices at arbitrary planes through a volume containing the stack of slices. This method clearly shows the spatial relationships between the different cell layers. The use of orthogonal cutting planes is preferred because of its analogy with classical vertical sections of histopathology. Linear structures (surface lines) within the stratum corneum are described and their global orientations were determined by the use of Fourier transform analysis. En face optical sections constitute unusual views of this tissue, since typical pathohistological studies are based on sagittal (vertical) slices. The noninvasive optical microscopic technique provides a three-dimensional optical biopsy of in vivo human skin. 相似文献
12.
M. A. A. Neil R. Jukaitis M. J. Booth T. Wilson T. Tanaka† & S. Kawata† 《Journal of microscopy》2000,200(2):105-108
We demonstrate aberration correction in two-photon microscopy. Specimen-induced aberrations were measured with a modal wavefront sensor, implemented using a ferro-electric liquid crystal spatial light modulator (FLCSLM). Wavefront correction was performed using the same FLCSLM. Axial scanned ( x z ) images of fluorescently labelled polystyrene beads using an oil immersion lens show restored sectioning ability at a depth of 28 µm in an aqueous specimen. 相似文献
13.
We consider the effect of the finite size of the detector on both the lateral and axial resolution of the confocal system. The use of a finite sized detector means that the imaging is no longer truly coherent. We find that the lateral resolution is considerably more sensitive to the detector size than is the axial response. The question of the rejection of flare light is also considered. Experimental results are shown and we find that acceptable extended-focus, auto-focus and height images may be obtained from non truly-confocal systems. We also find that lens apodization has a far greater effect on the axial resolution than the lateral resolution. 相似文献
14.
We consider the imaging in scanning microscopes employing point and slit-shaped detectors in both the bright-field and fluorescent mode. In particular we consider the three-dimensional aspects of the imaging and show inter alia that acceptable, albeit asymmetrical, images result from a slit detector system at low levels of defocus. The situation becomes worse as the defocus is increased although acceptable extended-focus and isometric images are still possible in some cases. 相似文献
15.
The effects of fluorescence saturation on imaging in confocal microscopy have been studied. To include saturation it was necessary to deviate from the widely assumed linear relationship between the fluorescence and the illumination intensity. The lateral response for a point-like object, as well as the optical sectioning power, decreases depending on the degree of saturation. For very high illumination intensities the response for a saturated point object approached that of a conventional fluorescence microscope in which the fluorescence was not saturated. The decrease in the axial confocal response has been confirmed qualitatively by experiment. 相似文献
16.
The relationship between integrated fluorescence intensity and integrated absorbance was measured in Feulgen-stained pigeon erythrocyte nuclei hydrolysed for different periods of time and stained at different dye concentrations. In conventional as well as confocal quantitative fluorescence microscopy the relationship between the integrated fluorescence intensity and the integrated absorbance shows a maximum. This is due to inner filtering and re-absorption of the excitation light and emission light respectively. In conventional quantitative fluorescence microscopy the relationship is influenced by the numerical aperture of the objective lens. Under confocal observation, as measured with the BIO-RAD MRC-500 Confocal Imaging System, no influence of the numerical aperture of the objective lens on the relationship between the integrated fluorescence intensity and the integrated absorbance could be observed. 相似文献
17.
In order to demonstrate the power of quantitative microscopy, the endocytic apparatus of rat hepatocytes was reexamined using in situ liver and short term cultured hepatocyte couplets that were allowed to internalize endocytic markers for various time intervals. Correlative confocal light and electron microscopy demonstrate a tubulovesicular reticulum representing the endocytic apparatus. Volume and membrane area account for 2% of cell volume and 30% plasma membrane surface. Colocalization analysis demonstrated that pathway-specific ligands and fluid-phase markers enter EEA1-positive vesicles, the early endosomal compartment, immediately after internalization. These vesicles are translocated rapidly from basolateral to perinuclear and apical locations. Ligands are sorted within 5 min to their respective pathways. Sequential colocalization of an asialoglycoprotein-pulse with rab7 and lamp3 demonstrates that early endosomes change into or fuse with late endosomes and lysosomes. Alternatively, markers are sequestered into the common endosome consisting of rab11-positive, long tubules that originate from early endosomes and show an affinity for the transcytotic marker pIgA and its receptor. This compartment mediates transcytosis by delivering the receptor-ligand complex to the subapical compartment, a set of apical, rab11-positive vesicles, which are connected to the tubular reticulum. We conclude that vesicular traffic between preexisting compartments, maturation or fusion of endocytic organelles, and transport in tubules act in concert and together mediate transport between compartments of a tubulovesicular endocytic apparatus. In addition, we show that quantitative microscopy using high resolution data sets can detect and characterize kinetics of various parameters thus adding a dynamic component to 3D information. 相似文献
18.
It is generally accepted that the functional compartmentalization of eukaryotic cells is reflected by the differential occurrence of proteins in their compartments. The location and physiological function of a protein are closely related; local information of a protein is thus crucial to understanding its role in biological processes. The visualization of proteins residing on intracellular structures by fluorescence microscopy has become a routine approach in cell biology and is increasingly used to assess their colocalization with well‐characterized markers. However, image‐analysis methods for colocalization studies are a field of contention and enigma. We have therefore undertaken to review the most currently used colocalization analysis methods, introducing the basic optical concepts important for image acquisition and subsequent analysis. We provide a summary of practical tips for image acquisition and treatment that should precede proper colocalization analysis. Furthermore, we discuss the application and feasibility of colocalization tools for various biological colocalization situations and discuss their respective strengths and weaknesses. We have created a novel toolbox for subcellular colocalization analysis under ImageJ, named JACoP, that integrates current global statistic methods and a novel object‐based approach. 相似文献
19.
Simona Rodighiero Bruno Torre Elisa Sogne Roberta Ruffilli Cinzia Cagnoli Maura Francolini Enzo Di Fabrizio Andrea Falqui 《Microscopy research and technique》2015,78(6):433-443
Confocal microscopy imaging of cells allows to visualize the presence of specific antigens by using fluorescent tags or fluorescent proteins, with resolution of few hundreds of nanometers, providing their localization in a large field‐of‐view and the understanding of their cellular function. Conversely, in scanning electron microscopy (SEM), the surface morphology of cells is imaged down to nanometer scale using secondary electrons. Combining both imaging techniques have brought to the correlative light and electron microscopy, contributing to investigate the existing relationships between biological surface structures and functions. Furthermore, in SEM, backscattered electrons (BSE) can image local compositional differences, like those due to nanosized gold particles labeling cellular surface antigens. To perform SEM imaging of cells, they could be grown on conducting substrates, but obtaining images of limited quality. Alternatively, they could be rendered electrically conductive, coating them with a thin metal layer. However, when BSE are collected to detect gold‐labeled surface antigens, heavy metals cannot be used as coating material, as they would mask the BSE signal produced by the markers. Cell surface could be then coated with a thin layer of chromium, but this results in a loss of conductivity due to the fast chromium oxidation, if the samples come in contact with air. In order to overcome these major limitations, a thin layer of indium‐tin‐oxide was deposited by ion‐sputtering on gold‐decorated HeLa cells and neurons. Indium‐tin‐oxide was able to provide stable electrical conductivity and preservation of the BSE signal coming from the gold‐conjugated markers. Microsc. Res. Tech. 78:433–443, 2015. © 2015 Wiley Periodicals, Inc. 相似文献
20.
S. RÜTTINGER V. BUSCHMANN B. KRÄMER R. ERDMANN R. MACDONALD F. KOBERLING 《Journal of microscopy》2008,232(2):343-352
Single molecule detection based on fluorescent labels offers the possibility to gain not only qualitative but also quantitative insight into specific functions of complex biological systems. Fluorescence correlation spectroscopy is one of the favourite techniques to determine concentrations and diffusion constants as well as molecular brightness of molecules in the pico‐ to nano‐molar concentration range, with broad applications in biology and chemistry. Although fluorescence correlation spectroscopy in principle has the potential to measure absolute concentrations and diffusion coefficients, the necessity to know the exact size and shape of the confocal volume very often hampers the possibility to obtain quantitative results and restricts fluorescence correlation spectroscopy to relative measurements mainly. The determination of the confocal volume in situ is difficult because it is sensitive to optical alignment and aberrations, optical saturation and variations of the index of refraction as observed in biological specimen. In the present contribution, we compare different techniques to characterize the confocal volume and to obtain the confocal parameters by fluorescence correlation spectroscopy curve fitting, a fluorescence correlation spectroscopy dilution series and confocal scanning of fluorescent beads. The results are compared in the view of quantitative fluorescence correlation spectroscopy measurement and analysis. We investigate how unavoidable artefacts caused by a non‐ideal confocal volume can be experimentally determined and validated. 相似文献