首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract Mold exposure in damp buildings is associated with both nasal symptoms and asthma development, but the progression of building-related (BR) rhinosinusitis symptoms to asthma is unstudied. We examined the risk of developing BR-asthma symptoms in relation to prior BR-rhinosinusitis symptoms and microbial exposure among occupants of a damp building. We conducted four cross-sectional health and environmental surveys among occupants of a 20-story water-damaged office building. We defined BR-rhinosinusitis symptom (N?=?131) and comparison (N?=?361) groups from participants' first questionnaire responses. We compared the odds for the development of BR-asthma symptoms between these two groups over the subsequent surveys, using logistic regression models adjusted for demographics, smoking, building tenure, and first-survey exposures to fungi, endotoxin, and ergosterol. The BR-rhinosinusitis symptom group had higher odds for developing BR-asthma symptoms [odds ratio (OR)?=?2.2; 95% confidence interval (CI)?=?1.3-3.6] in any subsequent survey compared to those without BR-rhinosinusitis symptoms. The BR-rhinosinusitis symptom group with higher fungal exposure within the building had an OR of 7.4 (95% CI?=?2.8-19.9) for developing BR-asthma symptoms, compared to the lower fungal exposure group without BR-rhinosinusitis symptoms. Our findings suggest that rhinosinusitis associated with occupancy of water-damaged buildings may be a sentinel for increased risk for asthma onset in such buildings. PRACTICAL IMPLICATIONS: Exposure to mold is associated with the development of asthma in damp building occupants, and rhinitis is known to be a risk factor for asthma. However, there is little information about the degree of risk for the progression of rhinosinusitis to asthma owing to mold exposures in damp buildings. Our study of damp building occupants demonstrates that building-related (BR) rhinosinusitis symptoms were a risk factor for the development of BR asthma symptoms and that exposure to mold (fungi) or other dampness-related agents augments risk for the development of BR asthma symptoms among those with BR rhinosinusitis symptoms. Our findings suggest that occurrence of BR upper respiratory illness in water-damaged buildings may presage future endemic asthma.  相似文献   

2.
In order to develop baseline data about United States office buildings, the United States Environmental Protection Agency conducted the Building Assessment Survey Evaluation (BASE) study, a systematic survey of 100 randomly selected United States office buildings, in the 1990s. This paper analyzes the self-reported work-related symptoms and job and workplace characteristics of 4326 respondents and compares results to the National Institute for Occupational Safety and Health's (NIOSH) study of 80 'complaint' buildings. Four distinct groups of symptoms, representing 'tiredness', 'mucosal irritation', 'neuropsychological', and 'lower respiratory' conditions emerged from factor analysis of work-related symptoms. The symptom grouping is identical for both surveys. Although the prevalence of each symptom is significantly higher in the NIOSH than in the BASE sample, there is overlap of the symptom distributions. In the BASE survey, 45% of the work force reported at least one work-related health symptom; 20% reported at least three symptoms. These findings imply that it is counterproductive to dichotomize buildings into healthy vs. unhealthy; instead the prevalence of health problems related to buildings span a continuum. PRACTICAL IMPLICATIONS: These results indicate that most office buildings have occupants who report building-related symptoms. This paper provides practical guidance for the comparison of building prevalences to the BASE normative data. Work-related symptom distributions and symptom groups can improve investigators' ability to identify IEQ problems.  相似文献   

3.
Volatile organic compounds (VOCs) were sampled in buildings where people with non-specific building-related symptoms perceive health problems and in buildings where they do not. In total, nine persons and 34 buildings were included in the study. The obtained VOC data was evaluated using multivariate methods, to investigate possible systematic differences in air quality of 'problem' and 'non-problem' buildings. All individual compounds were included as variables in a multivariate partial least squares (PLS) data analysis. 'Problem' and 'non-problem' buildings separated into two distinct groups, showing that air samples of the two groups of building were chemically different. PRACTICAL IMPLICATIONS: The study showed that there was an identifiable systematic difference in the collected VOC data between buildings causing and not causing problems for people with non-specific building-related symptoms (also called sick building syndrome, SBS). This is an important indication that even such volatile organic compounds that can be sampled by commonly used adsorbents are of importance for the presence of such symptoms. By coordination of procedures for sampling and analysis of VOCs in buildings between laboratories, to get large datasets and more general models, the method can become a useful diagnostic measure in evaluating indoor air and to identify chemical compounds and sources that contribute to SBS problems.  相似文献   

4.
Wood smoke exposure has been associated with adverse respiratory health outcomes, with much of the current research focused on wood smoke from domestic heating and cooking. This study examined the association between respiratory symptoms and outdoor wood smoke in Launceston, Tasmania, where ~ 30% of homes use wood burners for domestic heating. This ecological study examined data from participants of the 2004 Tasmanian Longitudinal Health Study postal survey and compared the prevalence of respiratory symptoms in Launceston (n = 601) with that in Hobart (n = 1071), a larger Tasmanian city with much less wood smoke. Multivariate logistic regression models were used to investigate the associations of interest while adjusting for gender, atopy, history of allergic disease and current smoking status. There were no significant differences in symptom prevalence between Launceston and Hobart. Two subgroup analyses, which examined participants with pre-existing chronic respiratory disease, and those who reported actively using a wood burner in their home, also did not find significant differences. Any impact of wood smoke on non-specific respiratory symptoms might have been overshadowed by other important determinants of respiratory health, such as vehicle exhaust and tobacco smoking, or were too small to have been detected. However, the lack of detectable differences in symptom prevalence might also reflect the success of regulatory action by local governments to reduce wood smoke emissions in Launceston. The results of other epidemiological studies support an association between ambient wood smoke exposure and adverse respiratory health. Further investigations of wood smoke exposure in Australian settings are needed to investigate the lack of significant associations found in this study, especially studies of indoor air quality and health impacts in children and elderly populations.  相似文献   

5.
We describe a military hospital building with severe, repeated and enduring water and mold damage, and the symptoms and diseases found among 14 persons who were employed at the building. The exposure of the employees was evaluated by measuring the serum immunoglobulin G (IgG)-antibodies against eight spieces of mold and yeast common in Finnish water and mold damaged buildings and by sampling airborne viable microbes within the hospital. The most abundant spieces was Sporobolomyces salmonicolor. All but one of the employees reported some building-related symptoms, the most common being a cough which was reported by nine subjects. Four new cases of asthma, confirmed by S. salmonicolor inhalation provocation tests, one of whom was also found to have alveolitis, were found among the hospital personnel. In addition, seven other workers with newly diagnosed rhinitis reacted positively in nasal S. salmonicolor provocation tests. Skin prick tests by Sporobolomyces were negative among all 14 workers. Exposure of the workers to mold and yeast in the indoor air caused an outbreak of occupational diseases, including asthma, rhinitis and alveolitis. The diseases were not immunoglobulin E (IgE)-mediated but might have been borne by some other, as yet unexplained, mechanism.  相似文献   

6.
Using a semi-quantitative mold exposure index, the National Institute for Occupational Safety and Health (NIOSH) investigated 13 college buildings to examine whether building-related respiratory symptoms among employees are associated with environmental exposure to mold and dampness in buildings. We collected data on upper and lower respiratory symptoms and their building-relatedness, and time spent in specific rooms with a self-administered questionnaires. Trained NIOSH industrial hygienists classified rooms for water stains, visible mold, mold odor, and moisture using semi-quantitative scales and then estimated individual exposure indices weighted by the time spent in specific rooms. The semi-quantitative exposure indices significantly predicted building-related respiratory symptoms, including wheeze [odds ratio (OR) = 2.3; 95% confidence interval (CI) = 1.1-4.5], chest tightness (OR = 2.2; 95% CI = 1.1-4.6), shortness of breath (OR = 2.7; 95% CI = 1.2-6.1), nasal (OR = 2.5; 95% CI = 1.3-4.7) and sinus (OR = 2.2; 95% CI = 1.2-4.1) symptoms, with exposure-response relationships. We found that conditions suggestive of indoor mold exposure at work were associated with building-related respiratory symptoms. Our findings suggest that observational semi-quantitative indices of exposure to dampness and mold can support action to prevent building-related respiratory diseases. PRACTICAL IMPLICATIONS: Current air sampling methods have major limitations in assessing exposure to mold and other biological agents that may prevent the demonstration of associations of bioaerosol exposure with health. Our study demonstrates that semi-quantitative dampness/mold exposure indices, based solely on visual and olfactory observation and weighted by time spent in specific rooms, can predict existence of excessive building-related respiratory symptoms and diseases. Relative extent of water stains, visible mold, mold odor, or moisture can be used to prioritize remediation to reduce potential risk of building-related respiratory diseases. From a public health perspective, these observational findings justify action to correct water leaks and repair water damage in order to prevent building-related respiratory diseases. This approach can also be a basis for developing practical building-diagnostic tools for water-incursion.  相似文献   

7.
Acute responses to 65 min exposures to environmental tobacco smoke (ETS) were tested in 24 healthy non-asthmatic nonsmokers and 16 asthmatic nonsmokers, using an environmental chamber. Each subject was exposed to air (sham), and machine-generated cigarette smoke containing 17 ppm and 31 ppm carbon monoxide (CO). Nonasthmatic subjects exercised intermittently (mean respiratory minute volume (V̊E) of 44 l/min during each of two 15–min exercise bouts); asthmatic subjects remained at rest. After completion of the exposure, subjects made a 0–5 rating of the severity of symptoms, as well as rating the overall severity of exposure on a 0–100 scale. Both symptoms and exposure severity rating were significantly related to CO concentrations. Ratings for a given ETS exposure tended to be higher for asthmatic than for nonasthmatic subjects. Overall exposure severity rating was significantly (p < 0.05) related to four symptom scores for the asthmatics and three for the nonasthmatic subjects. Symptoms common to both groups included unpleasant odour, and nasal discharge; shortness of breath was unique for nonasthmatics and eye irritation for asthmatk subjects. Although the nonasthmatic subjects were exercising intermittently, and thus received both a higher respiratory exposure (calculated from a CO-based index of ETS concentration, V̊E, and time) and biological exposure (calculated independently using a rebreathing estimate of the increment in carboxyhemoglobin level), the asthmatic subjects appeared to be more adversely affected by the ETS exposures in terms of their subjective responses.  相似文献   

8.
A high prevalence and racial disparities in asthma and allergy have been observed in American children. This study aimed to identify risk factors for asthma and allergy among children, and their contribution to racial disparities in allergy prevalence. A population-based cross-sectional study was carried out among children aged 1-8 years in Northeast Texas 2008-2009. The health conditions, life style and home environment of 3766 children were surveyed by parental questionnaires through e.g. daycares, elementary school, and medical clinics. Among participants who indicated their ethnicity, 255 were Mexican-Americans, 178 Afro-Americans and 969 Caucasians. Afro-American children had a significantly higher prevalence of asthma and eczema. Caucasian had the highest prevalence of rhinitis. Compared to Mexican-American children, Afro-American and Caucasian children were breast fed shorter time, more often went to day care center, had pets and environmental tobacco smoke exposure at home more often. For all children, being at a day care center, being exposed to dampness and environmental tobacco smoke at home were strong risk factors for asthma and allergy. Central air conditioning system was associated with an increased prevalence of wheeze among Mexican-American children, while pets were associated with an increased risk of rhinitis among Afro-American and Caucasian children. Caucasian children were generally not healthier than relatively poor Mexican-American children. Differences in the prevalence of asthma and allergy between races cannot be explained by socioeconomic status only. Life style and home environmental exposures are important risk factors for asthma and allergy in Northeast Texas children.  相似文献   

9.
We reviewed the literature on Indoor Air Quality (IAQ), ventilation, and building-related health problems in schools and identified commonly reported building-related health symptoms involving schools until 1999. We collected existing data on ventilation rates, carbon dioxide (CO2) concentrations and symptom-relevant indoor air contaminants, and evaluated information on causal relationships between pollutant exposures and health symptoms. Reported ventilation and CO2 data strongly indicate that ventilation is inadequate in many classrooms, possibly leading to health symptoms. Adequate ventilation should be a major focus of design or remediation efforts. Total volatile organic compounds, formaldehyde (HCHO) and microbiological contaminants are reported. Low HCHO concentrations were unlikely to cause acute irritant symptoms (<0.05 ppm), but possibly increased risks for allergen sensitivities, chronic irritation, and cancer. Reported microbiological contaminants included allergens in deposited dust, fungi, and bacteria. Levels of specific allergens were sufficient to cause symptoms in allergic occupants. Measurements of airborne bacteria and airborne and surface fungal spores were reported in schoolrooms. Asthma and 'sick building syndrome' symptoms are commonly reported. The few studies investigating causal relationships between health symptoms and exposures to specific pollutants suggest that such symptoms in schools are related to exposures to volatile organic compounds (VOCs), molds and microbial VOCs, and allergens.  相似文献   

10.
Seppänen O  Fisk WJ 《Indoor air》2002,12(2):98-112
This paper provides a synthesis of current knowledge about the associations of ventilation system types in office buildings with sick building syndrome (SBS) symptoms and discusses potential explanations for the associations. Most studies completed to date indicate that relative to natural ventilation, air conditioning, with or without humidification, was consistently associated with a statistically significant increase in the prevalence of one or more SBS symptoms, by approximately 30 to 200%. In two of three analyses from a single study (assessments), symptom prevalences were also significantly higher in air-conditioned buildings than in buildings with simple mechanical ventilation and no humidification. The available data also suggest, with less consistency, an increase in risk of symptoms with simple mechanical ventilation relative to natural ventilation. Insufficient information was available for conclusions about the potential increased risk of SBS symptoms with humidification or recirculation of return air. The statistically significant associations of mechanical ventilation and air conditioning with SBS symptoms are much more frequent than expected from chance and also not likely to be a consequence of confounding by several potential personal, job, or building-related confounders. Multiple deficiencies in HVAC system design, construction, operation, or maintenance, including some which cause pollutant emissions from HVAC systems, may contribute to the increases in symptom prevalences but other possible reasons remain unclear.  相似文献   

11.
Qin Yang  Juan Wang  Dan Norbäck 《Indoor air》2021,31(5):1402-1416
Risk factors at home for ocular, nasal, throat and dermal symptoms, headache, and fatigue were studied in a nationwide questionnaire survey in Sweden, the BETSI study in 2006. Totally, 5775 adults from a stratified random sample of multi-family buildings participated. Associations between home environment factors and weekly symptoms were analyzed by multi-level logistic regression. In total, 8.3% had ocular symptoms; 11.9% nasal symptoms; 7.1% throat symptoms; 11.9% dermal symptoms; 8.5% headache and 23.1% fatigue. Subjects in colder climate zones had more mucosal and throat symptoms but less fatigue and ocular symptoms. Rented apartments had poorer indoor environment than self-owned apartments. Those living in buildings constructed from 1961 to 1985 had most symptoms. Building dampness, mold and mold odor were risk factors, especially headache and ocular symptoms. Lack of mechanical ventilation system was another risk factor, especially for headache. Environmental tobacco smoke (ETS), electric radiators, and crowdedness were other risk factors. Oiled wooden floors, recent indoor painting, and new floor materials were negatively associated with symptoms. In conclusion, building dampness, mold, poor ventilation conditions, crowdedness, ETS, and emissions from electric radiators in apartments in Sweden can increase the risk of ocular, nasal, throat and dermal symptoms, headache, and fatigue.  相似文献   

12.
Based on a database accumulated from several recent surveys of office buildings located in a temperate climate (Denmark), the effect on occupant perceptions and symptom prevalence was compared in buildings with natural and with mechanical ventilation in which earlier studies have shown a discrepancy in the degree of perceived control. The database was composed of 1272 responses obtained in 24 buildings of which 15 had mechanical ventilation (997 responses) and nine had natural ventilation (275 responses). The number of occupant-reported control opportunities was higher in buildings with natural ventilation. Analysis of occupant responses, after grouping according to categories determined by the degree of satisfaction with the perceived control, showed that it was more likely the degree of control satisfaction that affected the prevalence of adverse perceptions and symptoms. Thus, the degree of control, as perceived by occupants, seemed more important for the prevalence of adverse symptoms and building-related symptoms than the ventilation mode per se. This result indicates that even though the development and application of new indoor environment sensors and HVAC control systems may allow for fully automated IEQ control, such systems should not compromise occupants’ perception of having some degree of control of their indoor environment.  相似文献   

13.
This stratified cross-sectional epidemiological study included 1053 school children aged 13-17 years. All pupils filled in a questionnaire on building-related symptoms and other relevant health aspects. The following exposure measurements were carried out: room temperature, CO2 level, and relative humidity; building characteristics including mold infestation were assessed, and dust was collected from floors, air, and ventilation ducts during a working day. Dust was examined for endotoxin level, and cultivated for viable molds. We did not find a positive association between building-related symptoms and extent of moisture and mold growth in the school buildings. Five of eight building-related symptoms were significantly and positively associated with the concentration of colony forming units of molds in floor dust: eye irritation, throat irritation, headache, concentration problems, and dizziness. After adjusting for different potentially confounding factors in separate analyses of each symptom, the above-mentioned associations between molds in dust and symptoms were still present, except for concentration problems. However, in none of the analyses was mold exposure the strongest covariate, being secondary to either asthma, hay fever, recent airway infection, or psychosocial factors.  相似文献   

14.
To evaluate the association of heating, ventilation and air-conditioning systems (HVAC) and respiratory symptoms in a tropical city, self-administered questionnaires were given to 2000 individuals working in air-conditioned office buildings and to 500 control workers in naturally ventilated buildings. Reported symptoms from the two populations were analyzed using chi-square tests, univariate and multiple logistic regressions models. Symptoms were the outcome variable and the odds ratios were adjusted by gender, age, accumulated work time, smoking habits and atopic background. There was a 79.8% response rate and there was a positive association of nasal symptoms (odds ratio, OR = 1.59, 95% confidence interval, CI = 1.11-2.28), naso-ocular symptoms (OR = 1.58, 95% CI = 1.05-2.38), persistent cough (OR = 3.04, 95% CI = 2.00-4.63) sinusitis symptoms (OR = 1.85, 95% CI = 1.27-2.71) and building-related worsening of the symptoms (OR = 4.92, 95% CI = 2.93-8.27) with working in air-conditioned buildings. In conclusion, our study suggests that artificial air-conditioning is a matter of concern for respiratory symptoms in cities with hot and humid climate. PRACTICAL IMPLICATIONS: This study suggests that indoor air-related respiratory symptoms are a matter of concern in places with hot and humid climate. The regression models were adjusted by confounders that could be used in further reanalysis of indoor air quality related symptoms and ventilation systems with expanded variety of climatic conditions.  相似文献   

15.
Li Li  Hang Liu  Yu Wang  Xu Han  Tanxi Ge  Lijun Pan 《Indoor air》2020,30(6):1178-1188
This study examined indoor air pollutants and their health effects on allergic rhinitis in 3194 employees of 226 bus station halls and then constructed a nomogram model to predict allergic rhinitis risk in those employees. Indoor air temperature, relative humidity, PM10, PM2.5, total bacteria, and total fungi were measured, and questionnaires were used to collect basic station information and employee health information. The results revealed that the over-standard rates of PM10, PM2.5, total bacteria, and total fungi were 18.16%, 31.13%, 2.22%, and 55.89%, respectively. Seasonal variations were found in temperature, relative humidity, and PM2.5. Passenger flow could affect temperature, and total bacteria. Central air conditioning could affect total bacteria. A total of 15.90% of the employees were diagnosed as allergic rhinitis by physicians. Relative humidity, fungi, self-reported allergic rhinitis symptoms, and exposure to smoking were the influencing factors for allergic rhinitis. These four variables were incorporated to construct a nomogram. The concordance index of the nomogram was 0.775 (95% CI: 0.745-0.806) and 0.749 (95% CI: 0.715-0.783) for the training cohort and test cohort, respectively. The calibration plot revealed that the nomogram model exhibited good discrimination and consistency. This nomogram model may help predict the occurrence of allergic rhinitis.  相似文献   

16.
Dong GH  Cao Y  Ding HL  Ma YN  Jin J  Zhao YD  He QC 《Indoor air》2007,17(6):475-483
The effects of childhood environmental tobacco smoke (ETS) exposure on respiratory symptoms were investigated in 6053 kindergarten-aged children residing in 15 districts of northern China. Responses to a self-administered questionnaire completed by parents of children from 30 kindergartens were used to ascertain children with persistent cough, persistent phlegm, asthma symptom, current asthma, wheeze and wheeze without asthma. In first 2 years ETS exposure and current ETS exposure were associated with increased prevalence of persistent cough, persistent phlegm, wheeze and wheeze without asthma. Among boys, ETS exposure was associated with more respiratory symptoms and diseases than in girls. ETS exposure during pregnancy was associated with asthma symptom [odds ratio (OR), 3.00; 95% confidence interval (CI): 1.28-7.03], current asthma (OR, 3.38; 95% CI: 1.25-9.14), persistent cough (OR, 1.64; 95% CI: 1.13-2.37), persistent phlegm (OR, 1.74; 95% CI: 1.01-3.01), wheeze (OR, 1.75; 95% CI: 1.15-2.68), and wheeze without asthma (OR, 1.46; 95% CI: 1.01-2.37) only among boys. In boys, the adjusted ORs for increased risk of asthma symptom and current asthma for household exposures (> or =10 cigarettes smoked per day vs. none smoked) during workday were 2.04 (95% CI: 1.01-3.89) and 2.76 (95% CI: 1.06-9.58), respectively. We conclude that ETS exposure increases the occurrence of respiratory symptoms and diseases during childhood. Boys may be more susceptible to ETS than girls. PRACTICAL IMPLICATIONS: Environmental tobacco smoke (ETS) is a highly prevalent respiratory irritant. In agreement with previous cross-sectional studies, our study indicates that exposure to ETS may increase the occurrence of respiratory symptoms and diseases in children, and the association of ETS exposure and respiratory health of children increased in strength with number of cigarettes smoked inside the house per day during workday and day-off. Boys may be more susceptible to ETS than girls. These findings support the view that measures should be taken to reduce ETS exposure for children.  相似文献   

17.
L. Lundin 《Indoor air》1999,9(2):92-102
Abstract The aim of the study was to describe how allergies and non-allergies perceive the same environment. All high school students in a town in southern Sweden were invited to answer a questionnaire concerning allergy, subjective symptoms, annoyance reactions and perception of the environment (response rate: 81%). The results show that only 45% of the students were non-allergic (n = 1,715). Since the symptom frequency among non-allergic students was normal, the schools were classified as healthy. However, compared to the non-allergic students, a higher percentage among the allergies suffered from symptoms every week, a lower percentage was satisfied with the air quality and the cleaning, and a higher percentage was bothered every week by temperature, stuffy/stale air, bad odor, passive smoke, bad lighting, noise, dust and dirt (ANOVA, P < 0.05). The findings could indicate that allergies note discomfort earlier than non-allergies by being more critical in general and especially critical to factors that could effect their health. The findings could also indicate that awareness of ones own sensitivity could lead to attention to different risk factors, which in turn could lead to stress/anxiety, which could make symptoms worse. The conclusion is that it is important to take allergy into consideration when the environment is assessed.  相似文献   

18.
The aim of this study was to explore the association between the building-related occupants’ reported health symptoms and the indoor pollutant concentrations in a sample of 148 office rooms, within the framework of the European OFFICAIR research project. A large field campaign was performed in 37 office buildings among eight countries, which included (a) 5-day air sampling of volatile organic compounds (VOCs), aldehydes, ozone, and NO2 (b) collection of information from 1299 participants regarding their personal characteristics and health perception at workplace using online questionnaires. Stepwise and multilevel logistic regressions were applied to investigate associations between health symptoms and pollutant concentrations considering personal characteristics as confounders. Occupants of offices with higher pollutant concentrations were more likely to report health symptoms. Among the studied VOCs, xylenes were associated with general (such as headache and tiredness) and skin symptoms, ethylbenzene with eye irritation and respiratory symptoms, a-pinene with respiratory and heart symptoms, d-limonene with general symptoms, and styrene with skin symptoms. Among aldehydes, formaldehyde was associated with respiratory and general symptoms, acrolein with respiratory symptoms, propionaldehyde with respiratory, general, and heart symptoms, and hexanal with general SBS. Ozone was associated with almost all symptom groups.  相似文献   

19.
In order to compare patterns of indoor air perception, including perceptions of temperature, air movement, indoor air quality (IAQ), mental concentration, and comfort, 33 subjects either with persistent allergic rhinitis or controls were exposed to different temperatures and constant relative humidity in an experimental office environment. Results were obtained by means of a self-administered visual analogue scale, analyzed using mean score comparisons and principal component analysis. At 14 degrees C, the rhinitis group reported higher scores for sensations of air dryness than controls. At 18 degrees C, in the rhinitis group, there was a correlation between dry, stagnant air, and difficult mental concentration. This group also correlated heat, dry air, and poor IAQ, in contrast to the control group, which correlated comfort, easy mental concentration, and freshness. At 22 degrees C, the rhinitis group correlated heat, dryness, stagnant air, and overall discomfort. This group also correlated non-dry air, freshness, and comfort, whereas the control group correlated heat, humidity, good indoor air, freshness, and comfort. This study suggests that the rhinitis group perceives indoor temperatures of 14 degrees C as dryer than controls do, and that at 18 and 22 degrees C this group positively correlates different adverse perceptions of IAQ. By means of a self-administered questionnaire in an experimental condition, the present study compares subjective patterns of indoor air perception from individuals with respiratory allergy (allergic rhinitis) to control individuals. It reports different patterns of perception of indoor air quality (IAQ) between the two groups, suggesting that allergic individuals could have different IAQ perception.  相似文献   

20.
Abstract This paper presents data on indoor air quality in schools as perceived by those working in them and relates these data to exposure measurements. Data on subjective air quality, domestic exposures and health aspects were gathered by means of a questionnaire which was sent to all personnel in 38 schools; it was completed by 1410 persons (85’4 of the total). Data on exposure were gathered by exposure measurements in classrooms. The results indicate that 53% of the personnel perceived the indoor air quality as bad or very bad. It was perceived as worse by those who were younger, those who were dissatisfied with their psychosocial work climate and those who were not exposed to tobacco smoke at home. In older school buildings and buildings with displacement ventilation there was less dissatisfaction with the air quality. There were no significant relations between complaints and air exchange rate or concentration of carbon dioxide. The air quality was perceived as worse at higher levels of exposure to a number of airborne compounds including volatile organic compounds, moulds, bacteria and respirable dust. It was concluded that exposure to indoor pollutants affects perception even at the low concentrations normally found indoors in nonindustrial buildings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号