1.
Shear failure of exterior beam-column joints is identified as the principal cause of collapse of many moment-resisting frame buildings during recent earthquakes. Effective and economical strengthening techniques to upgrade joint shear resistance and ductility in existing structures are needed. In this paper, efficiency and effectiveness of carbon fiber-reinforced polymer (CFRP) sheets in upgrading the shear strength and ductility of seismically deficient exterior beam-column joints have been studied. Four as-built joints were constructed with nonoptimal design parameters (inadequate joint shear strength with no transverse reinforcement) representing preseismic code design construction practice of joints and encompassing most of existing beam-column connections. Out of these four as-built specimens, two specimens were used as baseline specimens (control specimens) and other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All of these four subassemblages were subjected to cyclic lateral load histories so as to provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks through epoxy and externally bonding them with CFRP sheets under the same above two schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles, joint shear distortion, ductility, and stiffness degradation. The comparison shows that CFRP sheets are very effective in improving shear resistance and deformation capacity of the exterior beam-column joints and delaying their stiffness degradation.  相似文献   

2.
In this paper, efficiency and effectiveness of carbon fiber reinforced polymers (CFRPs) in upgrading the shear strength and ductility of seismically deficient corner or knee reinforced concrete beam-column joints have been studied. For this purpose, four as-built corner/knee joints were constructed with no transverse reinforcement, representing extreme case of preseismic code design construction practice of joints and encompassing many existing beam-column corner joints. Out of these four as-built specimens, two specimens were used as baseline specimens (control specimens) and other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All these four subassemblages were subjected to cyclic lateral load histories to simulate loading due to earthquake and provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks through epoxy and externally bonding them with CFRP sheets under the same above two schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles, ductility, and stiffness degradation. The comparison shows that CFRP sheets are very effective in improving shear resistance and deformation capacity of the corner beam-column joints and delaying their stiffness degradation. Shear capacities of control, repaired, and strengthened specimens were also predicted using writers’ published formulation. The predicted shear capacities were in a good agreement with the experimental values.  相似文献   

3.
In this paper, efficiency and effectiveness of carbon fiber-reinforced polymers (CFRP) in upgrading the shear strength and ductility of seismically deficient beam-column joints have been studied. For this purpose, four reinforced concrete interior beam-column sub-assemblages were constructed with nonoptimal design parameters (inadequate joint shear strength with no transverse reinforcement) representing preseismic code design construction practice of joints and encompassing the vast majority of existing beam-column connections. Out of these four, two specimens were used as baseline specimens (control specimens) and the other two were strengthened with CFRP sheets under two different schemes (strengthened specimens). In the first scheme, CFRP sheets were epoxy bonded to the joint, beams, and part of the column regions. In the second scheme, however, sheets were epoxy bonded to the joint region only but they were effectively prevented against any possible debonding through mechanical anchorages. All four subassemblages were subjected to cyclic lateral load histories so as to provide the equivalent of severe earthquake damage. Further, the damaged control specimens were repaired after filling the cracks through epoxy and wrapping them with CFRP sheets under the same two above-mentioned schemes. These repaired specimens were subjected to the similar cyclic lateral load history and their response histories were obtained. Hence, a total of six specimens were tested: two control; two strengthened; and two repaired. Response histories of control, repaired, and strengthened specimens were then compared. The results were compared through hysteretic loops, load-displacement envelopes, column profiles (maximum horizontal displacements of column along its height), joint shear distortion, ductility, and stiffness degradation. The comparison shows that CFRP sheets improve the shear resistance of the joint and increase its ductility. Results of two chosen schemes of strengthening were also compared and the importance of beam upgrading was highlighted.  相似文献   

4.
The research presented in this study involves full-scale experimental evaluation of carbon fiber-reinforced polymer (CFRP) rehabilitation for existing beam-column joints designed for gravity load with common pre-1970s deficient reinforcement details when subjected to cyclic loading. Numerous studies have demonstrated effectiveness of externally bonded fiber-reinforced polymer (FRP) materials for retrofitting the deteriorating RC structures. Although these materials are widely used in bridges, their applications in buildings have been somewhat limited. In particular, the experimental investigations on external FRP retrofit of deficient beam-column joints have not thoroughly been investigated and they are mainly on scaled-down specimens. The failure of these subassemblies, which possess lack of shear reinforcement within the joint core and shortly embedded positive beam reinforcement, would possibly result in catastrophic collapse of reinforced concrete frame structure during an earthquake event. Recognizing the urgent need to upgrade these structural subassemblies, the current investigation uses CFRP retrofit techniques to enhance the performance of such deficient joints. Experimental variables studied entail the developed CFRP retrofit configurations, and magnitude of the applied column axial load. Comparative analysis of the lateral loads versus drift hysteresis loops, stiffness degradation, and total dissipated energy curves of three as-built and three corresponding CFRP-retrofitted RC joints revealed that significant improvement in the shear capacity of the upgraded joints occurred. More importantly, the slippage of short embedded beam positive reinforcement into the joint was substantially controlled due to the developed CFRP retrofit. The results demonstrate the effectiveness of CFRP retrofit configurations in enhancing the structural performance of actual size connections.  相似文献   

5.
An experimental research program is described regarding the use of externally applied carbon fiber-reinforced plastic (CFRP) jackets for seismic rehabilitation of reinforced concrete interior beam-column joints, which were designed for gravity loads. The joints had steel reinforcement details that are known to be inadequate by current seismic codes in terms of joint shear capacity due to the absence of transverse steel hoops and bond capacity of beam bottom steel reinforcing bars at the joint. Lap splicing of beam bottom steel reinforcement at the joint using externally applied longitudinal CFRP composite laminates is investigated. Improvement of joint shear capacity using diagonal CFRP composite laminates is another strengthening scheme employed. Concrete crack widths for the as-built specimens and the extent of CFRP delamination for the rehabilitated specimens at various drift ratios are reported. The test results indicate that CFRP jackets are an effective rehabilitation measure for improving the seismic performance of existing beam-column joints with inadequate seismic details in terms of increased joint shear strength and inelastic rotation capacity. In addition, CFRP laminates are effective rehabilitation measures for overcoming problems associated with beam bottom steel bars that have inadequate embedment into the beam-column joints.  相似文献   

6.
To prevent the casualties that can result from the collapse of earthquake-damaged structures, it is important that structures be rehabilitated as soon as possible. This paper proposes a rapid rehabilitation scheme for repairing moderately damaged reinforced concrete (RC) beam-wide column joints. Four nonseismically detailed interior beam-wide column joints were used as control specimens. All four subassemblages were subjected to similar cyclic lateral displacement to provide the equivalent of severe earthquake damage. The damaged control specimens were then repaired by filling their cracks with epoxy and externally bonding them with carbon-fiber-reinforced polymer (CFRP) sheets and glass-fiber-reinforced polymer (GFRP) sheets. These repaired specimens were then retested and their performance compared with that of the control specimens. This paper demonstrates that the repair of damaged RC beam-wide column joints by using FRP can restore the performance of damaged RC joints with relative ease, suggesting that the repair of beam-column joints is a cost-effective alternative to complete demolition and replacement  相似文献   

7.
Most of the experimental studies available in literature on the seismic assessment and retrofit of existing, poorly detailed, reinforced concrete (RC) beam-column joints, typical of pre-1970s construction practice, have concentrated on the two-dimensional (2D) response, using unidirectional cyclic loading testing protocol and constant axial load. Even more limited information is available on the performance of exterior (corner) three-dimensional (3D) RC beam-column joints with substandard detailing subjected to bidirectional loading regime. In this study, the results of a comprehensive experimental program is presented, aiming to show the effects of varying axial and bidirectional loading on the seismic performance of deficient exterior RC beam-column joints before and after retrofit. Ten exterior beam-column joint subassemblies are tested, including four as-built specimens and six retrofitted specimens using externally bonded glass fiber-reinforced polymer (GFRP) sheets. Test results are herein presented and conclusions are drawn on the basis of the observed global and local performance. The significance of the triaxial interaction of varying axial and bidirectional loading effects on the response of retrofitted corner joints is confirmed by the experimental findings. The proposed retrofit solution was shown to be capable of re-establishing an appropriate hierarchy of strength within the subassembly, protecting the panel zone region from shear failure while promoting the formation of a plastic hinge in the beam.  相似文献   

8.
The feasibility and efficiency of a seismic retrofit intervention using externally bonded fiber-reinforced polymer composites on existing reinforced concrete frame systems, designed prior to the introduction of modern standard seismic design code provisions in the mid-1970s, are herein presented, based on analytical and experimental investigations on beam-column joint subassemblies and frame systems. A multilevel retrofit strategy, following hierarchy of strength considerations, is adopted to achieve the desired performance. The expected sequence of events is visualized through capacity-demand curves within M-N performance domains. An analytical procedure able to predict the enhanced nonlinear behavior of the panel zone region, due to the application of CFRP laminates, in terms of shear strength (principal stresses) versus shear deformation, has been developed and is herein proposed as a fundamental step for the definition of a proper retrofit solution. The experimental results from quasi-static tests on beam-column subassemblies, either interior and exterior, and on three-storey three-bay frame systems in their as-built and CFRP retrofitted configurations, provided very satisfactory confirmation of the viability and reliability of the adopted retrofit solution as well as of the proposed analytical procedure to predict the actual sequence of events.  相似文献   

9.
The objective of this research is to investigate the seismic performance of as-built, retrofitted, and repaired hollow bridge columns with insufficient shear strength. Two as-built full-scale columns were first tested and repaired using carbon-fiber-reinforced polymer composites (CFRP) jackets and dog-bone-shaped bars and then retested. Another two columns having the same reinforcement as the as-built columns were retrofitted with CFRP jackets. In addition to the tests, the repairability of the failed hollow columns was investigated by analytical evaluation. The test results and analysis of the retrofitted columns showed that CFRP composites can effectively strengthen shear-critical hollow bridge columns and can successfully transform the failure mode from shear to flexure. The test results of the repaired circular columns show that dog-bone-shaped bars successfully repaired the flexural damage caused by the fractured longitudinal bars.  相似文献   

10.
This paper details the use of carbon fiber reinforced polymer (CFRP) sheets to repair and strengthen prestressed concrete bridge girders in flexure and shear. Three specimens that were removed from an overloaded bridge (Bridge No. 56) in Graham County, Kansas were tested. Two of the specimens were repaired and strengthened, and all three were tested to failure to determine flexural capacity. Test results showed that two layers of longitudinal CFRP sheets increased the flexural capacity of the strengthened specimens by 20% compared to an unstrengthened control specimen. Shear capacity was also evaluated on both ends of each specimen. Two different cases were evaluated in shear. One case allowed shear cracks to propagate inside the transfer length of the prestressing strand, allowing a bond failure to occur. The second case forced the shear cracks to remain outside of the transfer length, thereby preventing a bond failure. The test results show that transverse CFRP sheets increased the shear capacity of the specimens tested by as much as 28%, but did not prevent bond failures.  相似文献   

11.
Shear failure is catastrophic and occurs usually without advance warning; thus it is desirable that the beam fails in flexure rather than in shear. Many existing reinforced concrete (RC) members are found to be deficient in shear strength and need to be repaired. Externally bonded reinforcement such as carbon-fiber-reinforced polymer (CFRP) provides an excellent solution in these situations. To investigate the shear behavior of RC beams with externally bonded CFRP shear reinforcement, 11 RC beams without steel shear reinforcement were cast at the concrete laboratory of the New Jersey Institute of Technology. After the beams were kept in the curing room for 28?days, carbon-fiber strips and fabrics made by Sika Corp. were applied on both sides of the beams at various orientations with respect to the axis of the beam. All beams were tested on a 979?kN (220?kips) MTS testing machine. Results of the test demonstrate the feasibility of using an externally applied, epoxy-bonded CFRP system to restore or increase the shear capacity of RC beams. The CFRP system can significantly increase the serviceability, ductility, and ultimate shear strength of a concrete beam; thus, restoring beam shear strength by using CFRP is a highly effective technique. An analysis and design method for shear strengthening of externally bonded CFRP has been proposed.  相似文献   

12.
13.
In order to reliably obtain seismic responses of as-built and repaired reinforced concrete bridge columns under near-fault ground motions, pseudodynamic testing of two bridge columns with a reduced scale of 2/5 was performed. Pseudodynamic test results reveal that a ductile member may have no chance to entirely develop its ductile behavior to dissipate seismic energy, because it may suddenly be destroyed by a significant pulse-like wave. The seismic performance of the two damaged bridge columns can be recovered after repair with carbon fiber reinforced plastics composite sheets. It is also experimentally confirmed that the flexural failure moment obtained from the pseudodynamic test is in good agreement with the plastic moment predicted by the ACI 318 code. As pseudodynamic test results are believed to be more accurate than numerical solutions, they can be considered as reference solutions in developing a finite-element model. An identical specimen was tested under cyclic loading to estimate basic properties of these columns, such as shear strength, flexural strength, and ductility, so that the seismic responses obtained from pseudodynamic tests can be thoroughly discussed. Furthermore, its hysteretic response may also be used to match a mathematical model to simulate the very complicated load-displacement relation for analysis.  相似文献   

14.
A one-fourth scale outrigger beam-column frame with as-built details was tested to assess its performance under reversed cyclic loading and to develop a retrofit procedure suitable for moderate seismic regions. The ductility of the as-built frame was limited due to pullout of poorly embedded positive moment reinforcement in the joint and shear inadequacy in the joint and beam. Strut-and-tie truss idealizations were developed to aid in predicting the failure mechanism and failure loads. Sectional and nonlinear finite-element analyses were used to predict the performance of the as-built outrigger frames. The retrofit procedure involved fiber-reinforced concrete sleeving of the beam and the joint, together with column jacketing, to enable plastic hinging and energy dissipation to occur in the column. This retrofit solution increased the strength, ductility, and energy absorption of the system. The provision of high-performance fiber-reinforced concrete in the beam sleeve was very effective in controlling the cracks and hence would improve durability.  相似文献   

15.
Repair, strengthening, and retrofit of reinforced and prestressed concrete members have become increasingly important issues as the World’s infrastructure deteriorates with time. Buildings and bridges are often in need of repair or strengthening to accommodate larger live loads as traffic and building occupancies change. In addition, inadequate design and detailing for seismic and other severe natural events has resulted in considerable structural damage and loss of life, particularly in reinforced concrete buildings. Numerous buildings and bridges suffer damage during such events and need to be repaired. The use of carbon fiber reinforced polymer (CFRP) composite fabric bonded to the surface of concrete members is comparatively simple, quick and virtually unnoticeable after installation. The use of composites has become routine for increasing both the flexural and shear capacities of reinforced and prestressed concrete beams. Earthquake retrofit of bridge and building structures has relied increasingly on composite wrapping of columns, beams and joints to provide confinement and increase ductility. This paper presents the results of cyclic testing of three large-scale reinforced concrete slab–column connections. Each of the specimens was a half-scale model of an interior slab–column connection common to flat-slab buildings. The specimens were reinforced according to ACI-318 code requirements and included slab shear reinforcement. While supporting a slab gravity load equivalent to dead load plus 30% of the live load, the specimens were subjected to an increasing cyclic lateral loading protocol up to 5% lateral drift. The specimens were subjected to the same loading protocol after they were repaired with epoxy crack sealers and CFRP sheet on the surfaces of the slab. Repair with epoxy and CFRP on the top surface of the slab was able to restore both initial stiffness and ultimate strength of the original specimen.  相似文献   

16.
The performance of rehabilitated reinforced concrete beam-column joints was compared with the response of existing joints designed to preseismic codes to assess proposed rehabilitation techniques. Six beam-column subassemblies with nonductile reinforcement detailing were tested. The joints were subjected to quasi-static load that simulates seismic forces. The first three specimens had inadequate anchorage length of the bottom beam bars. Two of them were strengthened by using carbon-fiber-reinforced polymer sheets attached to the bottom beam face and then tested. The other three specimens had no steel ties installed in the joint zone, in addition to inadequate anchorage length of the beam bars. Two of the beam-column joints were strengthened by glass-fiber-reinforced polymer jackets of the joint zone and steel rods or plates. The rehabilitation techniques were found effective in eliminating the brittle joint shear and steel bar bond-slip failure modes, and ductile beam hinging instead occurred.  相似文献   

17.
In this paper a procedure for analytical prediction of joint shear strength of interior beam-column joints, strengthened with externally bonded fiber-reinforced polymer (FRP) sheets, has been presented. The procedure is based on the formulation available in the literature. To implement the available formulation for shear capacity prediction a computer program has been developed. Using this program shear capacity of the joint and joint shear stress variation at various stages of loading have been predicted and compared with experimental observations; presented in Part I of this study. Predictions show good agreement with experimental test results. The formulation is further extended to predict diagonal tensile stresses in the joint. The effectiveness of FRP quantity on joint shear strength and on various strains has been studied on parametric basis. It is observed that even a low quantity of FRP can enhance shear capacity of the joint significantly and its effectiveness can be further increased if debonding is suppressed (e.g., through mechanical anchorages). Effect of column axial load on shear strength of the joint has also been studied. It is observed that axial load increases the confinement of the joint core, which in turn increases the shear capacity of the joint.  相似文献   

18.
A sound repair on a 40 year old four-span prestressed concrete girder bridge is performed with an innovative strengthening method using prestressed carbon fiber reinforced polymer (CFRP) sheets. In fact, this application is the first North American field application of its type. An adequate repair design is conducted based on the American Association of State Highway and Transportation Officials Load Resistance Factor Design (AASHTO LRFD) and the Canadian Highway Bridge Design Code. To ensure the feasibility of the site application using prestressed CFRP sheets, tests are conducted and closed-form solutions are developed to investigate the behavior of the anchor system that is necessary for prestressing the CFRP sheets. A full-scale finite-element analysis (FEA) is performed to investigate the flexural behavior of the bridge in the undamaged, damaged, and repaired states. The AASHTO LRFD exhibits conservative design properties as compared to the FEA results. The repaired bridge indicates that the flexural strength of the damaged girder has been fully recovered to the undamaged state, and the serviceability has also been improved. An assessment based on the AASHTO rating factor demonstrates the effectiveness of the repair.  相似文献   

19.
The aging infrastructure of the United States requires significant attention for developing new materials and techniques to effectively and economically revive this aging system. Damaged steel-concrete composite girders can be repaired and retrofitted by epoxy bonding carbon fiber-reinforced polymer (CFRP) laminates to the critical areas of tension flanges. This paper presents the results of a study on the behavior of damaged steel-concrete composite girders repaired with CFRP sheets under static loading. A total of three large-scale composite girders made of W355×13.6 A36 steel sections and 75-mm-thick by 910-mm-wide concrete slabs were prepared and tested. One, three, and five layers of CFRP sheet were used to repair the specimen with 25, 50, and 100% loss of the cross-sectional area of their tension flange, respectively. The test results showed that epoxy bonded CFRP sheet could restore the ultimate load-carrying capacity and stiffness of damaged steel-concrete composite girders. Comparison of the experimental and analytical results revealed that the traditional methods of analysis of composite beams were conservative.  相似文献   

20.
This paper presents the results of an experimental and analytical study of the fatigue performance of corroded reinforced concrete (RC) beams repaired with fiber-reinforced polymer (FRP) sheets. Ten RC beam specimens (152×254×3,200?mm) were constructed. One specimen was neither strengthened nor corroded to serve as a reference; three specimens were corroded and not repaired; another three specimens were corroded and repaired with U-shaped glass FRP sheets that wrapped the cross section of the specimen; and the remaining three specimens were corroded and repaired with U-shaped glass FRP sheets for wrapping and carbon-fiber-reinforced polymer (CFRP) sheets for flexural strengthening. The FRP sheets were applied after the main reinforcing bars were corroded to an average mass loss of 5.5%. Following FRP repair, some specimens were tested immediately to failure, while the other repaired specimens were subjected to further corrosion before being tested to failure to investigate their postrepair (long-term) performance. Reinforcement steel pitting due to corrosion reduced the fatigue life significantly. The FRP wrapping had no significant effect on the fatigue performance, while using CFRP sheets for flexural strengthening enhanced the fatigue performance significantly. The fatigue results were compared to smooth specimen fatigue data to estimate an equivalent fatigue notch factor for the main reinforcing bars of the tested specimens.  相似文献   