首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 5 毫秒
1.
Strength Evaluation of Deteriorated RC Bridge Columns   总被引:1,自引:0,他引:1  
Condition-rating methods followed by load rating calculations are used for evaluating existing bridges in the United States. Ratings are assessed visually based on engineering expertise and experience, and in some cases supplemented by nondestructive tests. Good understanding of the effects of deterioration on the structural performance leads to better inspection procedures, planning, and cost-effective rehabilitation methods. This paper presents a bridge pier column strength evaluation method that can be adapted into a currently used bridge condition evaluation method. This method uses damaged material properties, and accounts for amount of corrosion and exposed bar length for each reinforcement, concrete loss, bond failure, and type of stresses in the corroding reinforcement. The proposed evaluation method provides a good estimate of the condition and load-carrying capacity of bridge piers that currently cannot be obtained by normal visual surveys. In addition, the proposed evaluation approach will help reduce repair costs, avoid overconservative condition ratings, and result in a more uniform level of safety of concrete bridge substructure in the United States.  相似文献   

2.
The effect of varying transverse posttensioning levels and arrangements on the load response of a one-half scale 30° skewed seven box beam bridge model was investigated. The effective span of the bridge model was 9.45?m (31?ft) with a width of 3.35?m (11?ft) and depth of 355.6?mm (14?in.). The bridge model was prestressed and reinforced with carbon fiber composite cables (CFCCs). CFCCs were also used as shear reinforcement. The bridge model was provided with five transverse diaphragms equally spaced along the length of the bridge. The experimental investigation included load and strain distribution tests and a flexural ultimate load test. The load and strain distribution tests were conducted on the bridge model with and without full-depth longitudinal cracks at the shear-key locations. The investigation showed that the application of an adequate transverse posttensioning force was successful in restoring the load distribution of the bridge model with full-depth longitudinal deck cracks to that of the case without deck cracks. The ultimate load and the associated compression-controlled failure mode of the bridge model agreed well with that predicted according to ACI 440.4R-04 and numerical analysis. The behavior of the bonded pretensioned and reinforced CFCC strands was linear elastic and remained intact throughout the collapse of the bridge model. The unbonded transverse posttensioned CFCC strand also remained intact.  相似文献   

3.
In New Mexico, many reinforced concrete slab (RCS) bridges provide service on interstates I-10, I-25, and I-40. The load rating for this type of bridge largely depends on the live-load moment in the slab. Consequently, the objective of this study was to determine a more accurate value for the equivalent strip width using higher level evaluation techniques. A continuous RCS bridge was evaluated starting with an AASHTO load and resistance factor rating analysis. A diagnostic test was then conducted to measure live-load strains which showed that the slab stiffness fit within cracked and gross section behavior. Furthermore, slab moments from finite element analysis agreed reasonably well with experimental moments derived using the average of the cracked and gross section modulus. From refined analysis, the equivalent strip widths for positive moment were 26.1 and 22.1% greater than those calculated by the AASHTO approximate method for the exterior and interior spans, respectively. The refined widths for negative moment were greater than AASHTO by 13.1 and 11.1%. This increase in the equivalent strip width reduced the live-load effects, which proportionally increased the rating factors.  相似文献   

4.
North Carolina has recently installed a fiber-reinforced polymer (FRP) deck on steel girders at a site in Union County. The bridge was instrumented with foil strain gauges, strain transducers, and displacement transducers. The bridge was then tested with a simulated MS-22.5 design load. Experimental data confirmed full composite interaction between the girders and the FRP deck panels. The neutral axis was measured to be 383?mm above the bottom flange of the 618-mm-deep girder. It was found that composite action could be estimated within 3% using a transformed section analysis of the deck panels. For two lanes loaded, the maximum live load distribution factor was computed to be 0.75. When looking at the overall performance of the structure, the deck deflected 5?mm, with the allowable stress at least 10 times over the maximum stress measured in the material. The girder deflection of 7?mm was well within the parameters set forth by AASHTO. Simple span deflection equations were found to conservatively model the anticipated deflection of the girders when using the transformed section properties.  相似文献   

5.
Fiber-reinforced polymers offer several advantages over conventional construction materials but are also faced with several challenges. These include increased first cost, relatively low stiffness, and a lack of field experience. To address these challenges and to advance the state of the art, a hybrid fiber reinforced polymer/reinforced concrete bridge was designed and constructed in Texas. The bridge design and field evaluation are unique in several respects. Design considerations, the bid process, and the results of intermittent live load evaluations that have been conducted over a period of approximately 2 years are presented. Recommendations for the design of future similar bridges are provided.  相似文献   

6.
A curved, three-span continuous, steel I-girder bridge in Salt Lake City was tested in order to determine its dynamic and static load carrying properties for three boundary condition states. For each of the three boundary condition states, two dynamic forced vibration methods were applied to the bridge as well as a static live-load test. The first forced vibration method used an eccentric mass shaker. The second method involved striking the side of the bridge with an impact hammer. The live-load test was performed by slowly driving a truck at a crawl speed across the bridge. Velocity transducers, accelerometers, and strain gauges were utilized to record the response of the bridge. The analysis and compilation of recorded dynamic response of the bridge enabled the preparation of mode shapes and natural frequencies for each boundary condition. This paper discusses the resulting changes in relevant dynamic properties and compares them with the changes in the static properties that were determined from the bridge response recorded from the live-load tests.  相似文献   

7.
A series of 1G loading tests under the plane-strain condition were conducted on stiff ground with continuous square voids with the view of shallow foundation on calcareous sediment rocks, which contain voids because of their susceptibility to water dissolution. Detailed experimental observation revealed three types of failure modes for a single void: bearing failure without void failure, bearing failure with void failure, and void failure without bearing failure, depending on the location of the void as well as the size of the void. Upper-bound calculations were presented to interpret the changes of bearing capacity observed because of the existence of a void.  相似文献   

8.
This article discusses the use of nondestructive and laboratory testing techniques and load testing in evaluation of fire damage to precast prestressed concrete members in a parking structure. The in situ evaluation phase consisted of nondestructive testing of concrete using ultrasonic pulse velocity and radiographic exposures to locate tendons prior to the removal of cores. Flexural strength of concrete and dynamic Young’s modulus of elasticity and air permeability index of 25?mm (1?in.) thick disks sawed from the cores were determined in the subsequent laboratory testing phase. Analysis of concrete properties at small depth increments permitted assessment of whether a damage gradient was present and the nature of any gradient found, as expressed by changes in these properties. Based on the compromise in material properties indicated by nondestructive and laboratory testing, two affected double-tees were load tested. The deflection pattern observed during load testing confirmed the compromise indicated by the findings of the testing program.  相似文献   

9.
The study presented in this article concentrated on investigating the ductility and characterization of damage in concrete beams post tensioned with hybrid carbon-glass fiber-reinforced polymer (HFRP) composites. The investigation included an approach for design of flexural members with HFRP tendons and characterization of damage, load deformation response, ultimate strength, and failure modes. Direct tensile tests of hybrid FRP rods in a previous study had indicated elastoplastic response, enhanced ductility, and increased strain capacity. In this context, the current study focused on design and fabrication of post tensioned beams using glass or steel rebars for partial prestressing. All the beams were tested in flexure under four-point bending configuration. Results of the study are presented in terms of ductility index and enhanced load-deflection response in comparison with the conventional FRP materials. Damage characterization involved evaluating the specific features of the acoustic emissions for detecting the elastoplastic transition in the hybrid tendons. The method involved use of a high-resolution fiber-optic interferometer for detection and separation of acoustic emissions. By using the time domain response, it was possible to spatially localize the damage at various stages of the loading. Spectral energy of the acoustic emissions facilitated separation of carbon and glass fiber fractures.  相似文献   

10.
A full-scale unreinforced masonry (URM) wall with an opening was tested under in-plane lateral loading. The wall was first subjected to monotonically increasing displacements until a moderate damage level was reached. The damaged specimen was then cyclically tested up to almost the same maximum drift attained during the monotonic test to investigate the effects of previous damage on its nonlinear response. Finally, the masonry wall was repaired with inorganic matrix-grid (IMG) composites and subjected to a cyclic displacement-controlled test up to a near-collapse state. Most of the observed damage developed in the spandrel panel affecting both lateral resistance and strength degradation. Rocking of piers governed lateral stiffness and hysteretic response, which was characterized by low residual displacements and recentering behavior. The comparison between the experimental force-displacement curves demonstrated that the IMG strengthening system was able to provide energy dissipation capacity to the spandrel panel, restoring load-bearing capacity of the as-built wall, and delaying strength degradation that was indeed observed at larger displacements. Bilinear idealizations of force-displacement curves allowed the identification of displacement ductility, global overstrength, and strength reduction factor of the tested wall systems.  相似文献   