首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A high-speed rotational atherectomy was performed followed by adjunct directional atherectomy in 10 patients with symptomatic coronary artery disease and calcified target lesions and the results were evaluated using quantitative coronary arteriography and intravascular ultrasound. Target lesion calcium is common in obstructive coronary artery disease. High-speed rotational coronary atherectomy preferentially abrades noncompliant atherosclerotic plaque material, especially calcium, but often requires adjunct balloon angioplasty to achieve optimal lumen dimensions. Directional coronary atherectomy has limited efficacy in heavily calcified plaque; usually, it is a definitive primary procedure in large arteries with noncalcified target lesions. Neither of these devices alone is effective in treating calcified target lesions in large coronary arteries. Before intervention, after rotational and adjunct directional atherectomy, these measurements were obtained: quantitative coronary arteriographic measurements of minimal lumen diameter and percent diameter stenosis and intravascular ultrasound measurements of external elastic membrane, lumen, and plaque+media cross-sectional areas; percent cross-sectional narrowing; minimal lumen diameter; and target-lesion arc of calcium. With use of quantitative coronary arteriography, the preintervention minimal lumen diameter measured 0.7 +/- 0.4 mm, increased to 1.5 +/- 0.5 mm after rotational atherectomy (p = 0.0013) and to 2.5 +/- 0.3 mm after adjunct directional atherectomy (p < 0.001). The preintervention percent diameter stenosis measured 78 +/- 15%, decreased to 50 +/- 17% after rotational atherectomy (p = 0.0011), and to 17 +/- 11% (p < 0.001) after adjunct directional coronary atherectomy.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

2.
OBJECTIVES: The purpose of this study was to compare the immediate angiographic and long-term results of debulking versus balloon angioplasty for treatment of true bifurcation lesions. BACKGROUND: Previous studies have shown true bifurcation lesions to be a high risk morphological subset for percutaneous transluminal coronary angioplasty (PTCA). Although atherectomy devices have been used to treat bifurcation lesions, no studies have compared the outcomes of these alternative treatment modalities. METHODS: Between January 1992 and May 1997, we treated 70 consecutive patients with true bifurcation lesions (defined as a greater than 50% stenosis in both the parent vessel and contiguous side branch) with conventional PTCA (n = 30) or debulking (with rotational or directional atherectomy) plus adjunctive PTCA (n = 40). Paired angiograms were analyzed by quantitative angiography, and clinical follow-up was obtained in all patients. RESULTS: Acute procedural success was 73% in the PTCA group and 97% in the debulking group (p = 0.01). Major in-hospital complications occurred in two patients in the PTCA group and one in the debulking group. Treatment with atherectomy plus PTCA resulted in lower postprocedure residual stenoses than PTCA alone (16+/-15% vs. 33+/-17% in the parent vessel, and 6+/-15% vs. 39+/-22% in the side branch; p < 0.001 for both comparisons). At 1 year follow-up, the incidence of target vessel revascularization (TVR) was 53% in the PTCA group as compared with 28% in the debulking group (p = 0.05). Independent predictors of the need for repeat TVR were side branch diameter >2.3 mm, longer lesion lengths, and treatment with PTCA alone. CONCLUSIONS: For the treatment of true bifurcation lesions, atherectomy with adjunctive PTCA is safe, improves acute angiographic results, and decreases target vessel revascularization compared to PTCA alone. The benefits of debulking for bifurcation lesions were especially seen in lesions involving large side branches.  相似文献   

3.
Management of in-stent restenosis has become a significant challenge in interventional cardiology. The results of balloon angioplasty have been disappointing due to the high recurrence of restenosis at follow-up. Debulking of the restenotic tissue within the stents using directional coronary atherectomy (DCA) may offer a therapeutic advantage. We report the immediate clinical and angiographic outcomes and long-term clinical follow-up results of 45 patients (46 lesions), mean age 63+/-12 years, 73% men, with a mean reference diameter of 2.9+/-0.6 mm, treated with DCA for symptomatic Palmaz-Schatz in-stent restenosis. DCA was performed successfully in all 46 lesions and resulted in a postprocedural minimal luminal diameter of 2.7+/-0.7 mm and a residual diameter stenosis of 17+/-10%. There were no in-hospital deaths, Q-wave myocardial infarctions, or emergency coronary artery bypass surgeries. Four patients (9%) suffered a non-Q-wave myocardial infarction. Target lesion revascularization was 28.3% at a mean follow-up of 10+/-4.6 months. Kaplan-Meier event-free survival (freedom from death, myocardial infarction, and repeat target lesion revascularization) was 71.2% and 64.7% at 6 and 12 months after DCA, respectively. Thus, DCA is safe and efficacious for the treatment of Palmaz-Schatz in-stent restenosis. It results in a large postprocedural minimal luminal diameter and a low rate of both target lesion revascularization and combined major clinical events at follow-up.  相似文献   

4.
With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.  相似文献   

5.
We examined the relation between diabetes mellitus and outcomes in patients undergoing percutaneous coronary revascularization in the Coronary Angioplasty Versus Excisional Atherectomy Trial (CAVEAT-I), a randomized trial comparing treatment with either percutaneous transluminal coronary angioplasty or directional atherectomy for de novo lesions in native coronary arteries. Acute success and complication rates, 6-month angiographic restenosis rates, and 1-year clinical outcomes were compared between diabetic and nondiabetic patients undergoing each procedure. Acute success rates between diabetic (n = 191) and nondiabetic (n = 821) patients were similar for both revascularization techniques. Except for the need for dialysis, complication rates were also similar. Six months after atherectomy, diabetic patients had significantly more angiographic restenosis than nondiabetics (59.7% vs 47.4%) and significantly smaller minimum luminal diameters (1.20 vs 1.40 mm). Diabetics undergoing atherectomy required more frequent bypass surgery (12.8% vs 8.5%) and more repeat percutaneous revascularizations (36.5% vs 28.1%) than nondiabetics undergoing atherectomy. Restenosis rates, minimum luminal diameters and repeat revascularizations between diabetics and nondiabetics undergoing angioplasty were similar. The higher restenosis and repeat revascularization rates and the smaller minimum luminal diameter at follow-up in diabetic patients suggest that atherectomy may provide only modest benefit for these patients. The increased restenosis rate in diabetics undergoing atherectomy (but not angioplasty) requires further evaluation.  相似文献   

6.
Strategies for dilatation of bifurcation stenoses have continued to evolve over the past several years. However, there is limited experience on the efficacy of various nonballoon interventional devices and their results in comparison with balloon angioplasty. We, therefore, analysed our data in 72 patients of coronary artery disease with true bifurcation stenoses with balloon angioplasty or new device interventions (NDI). All patients underwent dilatation of both the primary vessel and side branch ostial stenosis. Balloon angioplasty using double guidewire with sequential or simultaneous (kissing balloon) balloon inflation in the two vessels was performed in 42 patients. Thirty patients underwent NDI, using directional coronary atherectomy (DCA) in 12, rotablation in 6 and elective coronary stents in 12 patients. There were no significant differences in the baseline clinical and angiographic variables between patients in the two groups. While the preprocedural luminal diameter stenosis was similar, the residual stenosis was significantly less, both in the primary vessel and side branch, after NDI compared to balloon angioplasty. The procedure was successful in 96.6 percent patients treated with NDI and 83.3 percent with balloon angioplasty (p < 0.01) with relief of obstruction in both branches without any major complications. Freedom from subsequent coronary events in the form of angina, myocardial infarction, PTCA, bypass graft surgery of death was significantly more, both at 6 months (92% versus 65.6%, p < 0.001) and 12 months (81.8% versus 53.1%, p < 0.001) in the group of patients treated with NDI compared to balloon angioplasty. It is, therefore, concluded that NDI including DCA, rotablation and elective stenting are associated with higher rate of success, lesser complications and better event-free survival in comparison to balloon angioplasty for treatment of true bifurcation stenoses.  相似文献   

7.
This study compares the immediate and long-term outcomes of a primary coronary stenting strategy with primary balloon angioplasty with stent bailout in the treatment of patients with acute myocardial infarction (AMI). One hundred forty-seven consecutive patients who underwent primary balloon angioplasty with stent bailout (n = 94) or primary stenting (n = 53) for AMI were clinically followed for 8.1 +/- 5.7 and 8.5 +/- 4.5 months, respectively. Immediate results, as well as in-hospital and long-term ischemic events (death, reinfarction, and repeat revascularization) were compared between both groups. Angiographic success was 91.5% in the balloon angioplasty group and 94% in the stent group. In-hospital and late follow-up combined ischemic events were 22 of 94 (23%) versus 0 of 53 (0%); p < 0.001 and 33 of 78 (42%) versus 13 of 53 (25%), p = 0.04 for the balloon angioplasty and stent groups, respectively. At 6 months, the cumulative probability of repeat target lesion revascularization was higher in the balloon angioplasty group (47% vs 18%, p = 0.0006) as was the probability of late target revascularization (36% vs 18%, p = 0.046); the cumulative event-free survival after 6 months was significantly lower in the balloon angioplasty group (44% vs 80%, p = 0.0001). This study demonstrates that a primary stent placement strategy in patients with AMI is safe, feasible, and superior to primary balloon angioplasty with stent bailout. Primary stenting results in a larger postprocedural minimal luminal diameter, a lower early and late recurrent ischemic event rate, and a lower incidence of target lesion revascularization at follow-up.  相似文献   

8.
OBJECTIVES: We sought to evaluate the immediate angiographic results and intermediate-term follow-up after percutaneous treatment of left main coronary stenoses in the new device era. BACKGROUND: Historically, balloon angioplasty of left main coronary stenoses has been associated with high procedural morbidity and poor long-term results. It is not clear whether new devices are more effective in this anatomic setting. METHODS: Between July 1993 and July 1995, we performed initial left main coronary interventions on 46 patients (mean age 67 +/- 12 years, 26% women). Quantitative angiography was available for 42 of 46 interventions, and clinical follow-up was obtained for all patients at 1 month, 6 months and 1 year after initial revascularization. RESULTS: Most interventions (42 of 46) were performed in patients with "protected" coronary stenoses to the left coronary system owing to the presence of one or more patent left main coronary grafts. Seventy-seven percent of screened patients were deemed unsuitable for repeat coronary artery bypass surgery. Procedures performed included stenting in 73% of patients (alone in 30% and after rotational atherectomy in 43%), rotational atherectomy in 58% (alone in 15% and before stenting in 43%), directional atherectomy in 4% and angioplasty alone in 7%. Initial procedural success was achieved in all interventions, with no deaths, myocardial infarctions (creatine kinase, MB fraction > 50 IU/liter) or emergent bypass surgery. Follow-up data to date (median duration 9 months, range 6 to 19) demonstrate a 98% overall survival rate and a 6-month event-free survival rate of 78% (six target vessel revascularizations [TVRs], four non-TVRs). CONCLUSIONS: Treatment of protected left main coronary artery stenoses can be accomplished safely and effectively with new device technology. Intermediate-term follow-up demonstrates an acceptably low rate of death, myocardial infarction or repeat revascularization at 6 months and 1 year.  相似文献   

9.
The Bard Atherectomy Catheter is a new rotational atherectomy device that consists of a flexible, hollow, thin-walled cutting catheter that, while rotated at 1,500 revolutions per minute, is advanced across the lesion over a special spiral guidewire system. We report the initial clinical experience with this device in 20 peripheral lesions in ten patients. The majority of patients were treated for limb salvage. All lesions were successfully intervened on by atherectomy followed by adjunctive balloon angioplasty. A reduction to less than 50% stenosis was achieved in 13 of the 20 lesions (65%) after atherectomy but in all 20 lesions (100%) after adjunctive angioplasty for all lesions and stenting for dissections in two. Baseline minimal lesion lumen diameter was 0.8 +/- 0.7 mm with a reference vessel diameter of 4.2 +/- 1.7 mm (75 +/- 21% stenosis). The lumen improved to 2.0 +/- 0.8 mm (45 +/- 19% stenosis) (P < 0.001) following atherectomy and to 3.9 +/- 1.9 mm (13 +/- 16% stenosis) (P < 0.001) after adjunctive angioplasty. The average weight of removed atheroma was 45 +/- 58 mg. All ten patients had initial improvement in symptoms. At 6 months follow-up there was persistent improvement in eight patients and two subjects had undergone amputations. Our early clinical experience with this low profile, flexible atherectomy device, that enables extraction of a large amount of atheroma, suggests that it will become a valuable addition to current atherectomy technologies in small- and medium-sized vessels. The value of this device in coronary vessels is under investigation.  相似文献   

10.
OBJECTIVES: The purpose of this study was to assess the dual action of lumen enlargement and vessel wall damage following either balloon angioplasty or directional atherectomy, using intracoronary ultrasound, and angioscopy. BACKGROUND: Differences in the mechanisms of action of balloon angioplasty and directional atherectomy may have a significant bearing on the immediate outcome and the restenosis rate at 6 months. METHODS: A total of 36 patients were studied before and after either balloon angioplasty (n = 18) or directional atherectomy (n = 18). Ultrasound measurements included changes in lumen area, external elastic membrane area and plaque burden. In addition, the presence and extent of dissections were assessed to derive a damage score. Angioscopic assessment of the dilated or atherectomized stenotic lesions was translated into semi-quantitative dissection, thrombus and haemorrhage scores. RESULTS: Atherectomy patients had a larger angiographic vessel size compared with the angioplasty group (3.55 +/- 0.46 mm vs 3.00 +/- 0.64 mm, P < 0.05); however, minimal lumen diameter (1.18 +/- 0.96 mm vs 0.85 +/- 0.49 mm) and plaque burden (17.04 +/- 3.69 vs 15.23 +/- 4.92 mm2) measurements did not differ significantly. As a result of plaque reduction, atherectomy produced a larger increase in luminal area than the angioplasty group (5.80 +/- 1.78 mm2 vs 2.44 +/- 1.36 mm2, P < 0.0001). Lumen increase after angioplasty was the result of 'plaque compression' (50%) and wall stretching (50%). Additionally, in both groups there was indirect angioscopic evidence of thrombus 'microembolization' as an adjunctive mechanism of lumen enlargement. Angioscopy identified big flaps in six and small intimal flaps in 11 of the atherectomized patients as compared with five and 12 patients in the angioplasty group. Changes in thrombus score following both coronary interventions were identical (0.72 +/- 3.42 points atherectomy vs -0.38 +/- 3.27 points balloon angioplasty, ns). CONCLUSIONS: Lumen enlargement after directional atherectomy is mainly achieved by plaque removal (87%), whereas balloon dilation is the result of vessel wall stretching (50%) and plaque reduction (50%). Despite the fact that the luminal gain achieved by directional atherectomy is twice that achieved with balloon angioplasty, the extent of trauma induced by both techniques seems to be similar.  相似文献   

11.
Secondary to the low attrition rate of internal mammary artery grafts, limited data are available on the clinical and angiographic outcome of patients who have undergone balloon angioplasty of an internal mammary artery stenosis. This study examined a consecutive series of 68 patients who underwent balloon angioplasty of an internal mammary artery graft over a 9-year period. Procedural success was achieved in 60 of 68 (88%) patients. The primary reason for procedural failure was extreme vessel tortuosity. There were no major in-hospital complications. Angiographic follow-up was obtained in 78% of the patients with an angiographic restenosis rate of 19%. The overall event-free survival in patients with an initially successful procedure was 92%. In conclusion, internal mammary artery balloon angioplasty has both an excellent initial success rate as well as a low incidence of restenosis and repeat target lesion revascularization.  相似文献   

12.
The effect of domestically-manufactured excimer laser with adjunctive balloon angioplasty in achieving revascularization and reduction of residual stenosis was assessed. 20 femoral arteries with thrombosis and occlusion from 12 dogs were subject to angiography. At first excimer laser angioplasty was done followed by balloon angioplasty. The diameter and residual stenosis of revascularized vessel were measured. The result showed that 17 out of 20 vessels (85%) were revascularized. The diameter of revascularized vessel by excimer laser were 1.22 +/- 0.14 mm, while residual stenoses were 54% +/- 5%. After adjunctive balloon angioplasty the diameter and residual stenoses were 2.04 +/- 0.16 mm and 20% +/- 7% respectively (P < 0.05 and P < 0.01). Complication in form of vasoperforation occurred in 3/20 vessels (15%). It is concluded that China- manufactured excimer laser angioplasty is effective when used for revascularization. While the reduction of narrowing and residual stenoses was enhanced after adjunction of balloon angioplasty. This method can be employed in treating peripheral occlusive disease effectively and safely.  相似文献   

13.
Angioplasty of aorto-ostial stenosis is associated with lower procedural success and a higher complication rate. The aim of the present study was to compare the acute and long-term results of balloon and new device angioplasty in 110 consecutive patients with right coronary ostial lesions. Patients were divided into 3 groups according to the angioplasty device used: group I (balloon only, n = 26), group II (debulking devices including excimer laser, directional and rotational atherectomy, n = 26), group III (stent, n = 58). Procedural success was highest in group III (96%) followed by group I (88%), and group II (77%). In-hospital complications were similar among the groups (p = NS). Patients in group III achieved the highest acute gain (2.61 mm) followed by groups II (1.92 mm), and I (1.39 mm, p <0.05). During follow up, target lesion revascularization and/or bypass surgery was required in 24% of patients in group III compared with 47% and 40% in groups I and II, respectively (p <0.05). Cardiac-event free survival was highest in the stent group (74%, p <0.005) and was similar between the balloon (39%) and debulking device groups (45%). Thus, among the currently available technologies, stenting of right coronary ostial lesions appears to provide excellent angiographic and long-term results.  相似文献   

14.
BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.  相似文献   

15.
BACKGROUND: The type of remodeling of the human femoral artery (enlargement or shrinkage) is related to the percentage luminal stenosis. OBJECTIVE: To assess how local changes in vessel size, together with plaque load, determine luminal narrowing in atherosclerotic human coronary arteries. METHODS: We obtained 576 segments of 28 coronary arteries from 10 patients who had died from noncardiac causes. The lumen area and area circumscribed by the internal elastic lamina (IEL) area, a measure of local vessel size in each histologic cross-section were measured, and the mean lumen diameter and mean IEL diameter were calculated. To correct for arterial tapering, expected reference diameter values were calculated at the same location using linear regression of all data points along the artery. The IEL diameter and lumen diameter were expressed as percentages of the calculated IEL diameter and lumen diameter at the same location (percentage lumen diameter stenosis and relative IEL diameter, respectively). RESULTS: We found a negative relation between the relative IEL diameter and the percentage lumen diameter stenosis. On average, a narrower than expected lumen diameter was accompanied by a smaller than expected IEL diameter. A larger than expected lumen diameter was accompanied by a larger than expected IEL diameter. This relation was found for the left anterior descending, circumflex, and right coronary arteries (y = -0.60x + 105.33, r = 0.48; y = -0.45x + 100.69, r = 0.84; and y = -0.39x + 101.84, r = 0.61, respectively, all P < 0.05). CONCLUSIONS: Local luminal narrowing was correlated with a decrease in vessel size. Local remodeling of the artery is one of the determinants of luminal narrowing in the atherosclerotic human coronary artery.  相似文献   

16.
Rotational atherectomy is effective acutely in treating complex coronary disease, but less is known about its long-term clinical outcome. We examined the acute results and late clinical outcome in 178 patients undergoing treatment with this device. Rotational atherectomy was used to treat 240 lesions in 178 individual patients. Nineteen percent had multilesion or staged multivessel procedures, and 71% had AHA-ACC Type B2/C lesions. The procedure was completed successfully in 94% of patients. Major complications occurred in 6% (death 1%, Q-MI 2.8%, and emergency bypass surgery 2.2%). Clinical follow-up was available for 167 (94%) patients at 13+/-6 months. Thirty-five percent required additional catheterization because of recurrent symptoms or an abnormal stress test. Clinical restenosis was confirmed in 18%, and an additional 2.2% of patients had progression of disease in previously untreated segments. At the end of 1 year, 14% had undergone repeat target vessel revascularization. Cumulatively at follow-up, approximately 80% had avoided an acute major complication and repeat revascularization for restenosis. Rotational atherectomy provides excellent acute and good late clinical results. At 1 year follow-up, the likelihood of developing clinical restenosis or significant progression of disease was 1 in 5, and patients had a 1 in 7 chance of requiring revascularization because of restenosis. These findings are encouraging and indicate that rotational atherectomy can be performed safely and with a high degree of acute and late clinical success in complex coronary disease characterized by multivessel or multilesion involvement and a predominance of B2 and C lesions.  相似文献   

17.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

18.
BACKGROUND: Treatment of stenosis in saphenous-vein grafts after coronary-artery bypass surgery is a difficult challenge. The purpose of this study was to compare the effects of stent placement with those of balloon angioplasty on clinical and angiographic outcomes in patients with obstructive disease of saphenous-vein grafts. METHODS: A total of 220 patients with new lesions in aortocoronary-venous bypass grafts were randomly assigned to placement of Palmaz-Schatz stents or standard balloon angioplasty. Coronary angiography was performed during the index procedure and six months later. RESULTS: As compared with the patients assigned to angioplasty, those assigned to stenting had a higher rate of procedural efficacy, defined as a reduction in stenosis to less than 50 percent of the vessel diameter without a major cardiac complication (92 percent vs. 69 percent, P<0.001), but they had more frequent hemorrhagic complications (17 percent vs. 5 percent, P<0.01). Patients in the stent group had a larger mean (+/-SD) increase in luminal diameter immediately after the procedure (1.92+/-0.30 mm, as compared with 1.21+/-0.37 mm in the angioplasty group; P<0.001) and a greater mean net gain in luminal diameter at six months (0.85+/-0.96 vs. 0.54+/-0.91 mm, P=0.002). Restenosis occurred in 37 percent of the patients in the stent group and in 46 percent of the patients in the angioplasty group (P=0.24). The outcome in terms of freedom from death, myocardial infarction, repeated bypass surgery, or revascularization of the target lesion was significantly better in the stent group (73 percent vs. 58 percent, P = 0.03). CONCLUSIONS: As compared with balloon angioplasty, stenting of selected venous bypass-graft lesions resulted in superior procedural outcomes, a larger gain in luminal diameter, and a reduction in major cardiac events. However, there was no significant benefit in the rate of angiographic restenosis, which was the primary end point of the study.  相似文献   

19.
OBJECTIVE: This study assesses artifactual luminal distortion, or eccentricity, that affects measurement of stenosis on CT angiography performed with a variety of helical protocols. MATERIALS AND METHODS: A 32-vessel carotid artery phantom was built with five known grades of stenoses (25%, 50%, 75%, 88%, and 94%) and three lengths of stenosis (1, 3, and 5 mm). This phantom was scanned with conventional and 1.0-, 1.5-, and 2.0-pitch helical CT with slice thicknesses of 2, 4, and 8 mm, and three vessel orientations: parallel, 45 degrees oblique, and perpendicular to the z-axis. Oblique multiplanar reconstruction was performed with the latter two vessel orientations to produce images similar to the parallel to z-axis orientation. The cross-sectional images were then used to measure the maximum and minimum (longest and shortest) luminal diameters in and out of each stenosis at a computer workstation by a single investigator who was unaware of the scanning technique. Percentage of stenosis was assessed by three methods: cross-sectional area in and out of the stenosis, maximum diameter out of stenosis and minimum in stenosis (North American Symptomatic Carotid Endarterectomy Trial method), and minimum diameter in and out of the stenosis. Comparisons were made with the gold standard using the equation (measured percentage of stenosis-actual percentage of stenosis) based on known luminal diameters of the phantom. Luminal eccentricity was assessed for each of the vessels and scanning parameters as a ratio of minimum to maximum diameters. RESULTS: All three methods of measuring stenoses were strongly affected by luminal eccentricity. The North American Symptomatic Carotid Endarterectomy Trial method overestimated percentage of stenosis an average of 1.64%. The most accurate results were obtained when using the minimum diameter in and out of the stenoses (-0.45% from the gold standard). Eccentricity was significantly greater in stenoses than in normal lumen (p < .0001) and when the vessels were oriented perpendicular to the z-axis (p = .0003). A progressive increase in eccentricity was seen in the 4- and 8-mm slice thicknesses and the 3- and 5-mm-long stenoses (p < .001; p < .001). CONCLUSION: Artifactual luminal eccentricity has significant implications for measuring percentage of stenosis revealed by CT angiography. Eccentricity increases in longer stenoses, thicker slices, and vessels oriented perpendicular to the z-axis. With CT angiography, measurement of minimum diameters in and out of a stenosis provides the most accurate assessment of percentage of stenosis.  相似文献   

20.
Intravascular ultrasound (IVUS) imaging was used to measure internal luminal area immediately after percutaneous transluminal coronary angioplasty (PTCA) in 83 patients (59 males, 24 females, mean age 63 +/- 12 years) with angina pectoris to determine the need for additional intervention. The effectiveness of these interventions to prevent restenosis was also studied. Thirty-five patients (42%) with insufficient dilatation revealed an internal luminal area less than 5 mm2 or luminal stenosis greater than 60% as evaluated by IVUS imaging following the procedure. The luminal area increased from 4.5 +/- 1.1 to 7.9 +/- 2.8 mm2 and the percentage luminal stenosis improved from 66 +/- 9% to 54 +/- 9% in patients who underwent further dilatation with a larger size balloon, longer dilatation time, directional coronary atherectomy, or stenting. The insufficient dilatation group exhibited hard plaque and calcification more frequently than in the other group (48 patients, 58%) in whom sufficient dilatation of the target lesion was achieved. The incidence of restenosis in the sufficient dilatation group was 25%, compared to 33% of the patients receiving additional treatment after IVUS imaging and 42% in the 192 patients who underwent PTCA without IVUS imaging. IVUS imaging is a useful method for evaluation of complex luminal morphology to decrease the incidence of restenosis and for determination of the end point and the extent of dilatation required.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号