High frequency RFID sensors are attractive in diverse applications where sensor performance is required at a low cost and dimension restriction. An approach adapting commercial passive 13.56 MHz RFID tags has been developed for sensing corrosion stage. This investigation includes balance of sensing and positioning of RFID sensors for corrosion detection by analysing real and imaginary parts of the complex impedance. With passive HF RFID sensors, real part and imaginary part of complex impedance have been extracted from the reader coil with VNA (vector network analyser) and delivering a unique capability for corrosion sensing with different atmospheric exposure time steel samples (1 month, 6 months, 10 months and 12 months). With different positioning (5–25 mm), features extraction based on the complex impedance with PCA (principal component analysis) has been designed for position-independent corrosion evaluation.  相似文献   

2.
Low pressure drop thermal Mass Flow Controllers are generally thought to fulfill needs concerning the realization of a dynamic reference gas mixture generator for accurate gas analysis. A small air flow rate at low pressure drop must be controlled in a stable and precise way in the generator. True operative pressure drop limits, set point reproducibility, calibration needs and flow rate stability during operations were investigated for a low pressure drop thermal Mass Flow Controller. The flow rate bias due to late calibration and flow rate short-term stability were measured and discussed. The Allan method was used to calculate stability during operation. Calibration uncertainty, bias for late calibration, stability and set point reproducibility were composed to calculate the total uncertainty of the flow rate as a function of the operation time. Results show that it is possible to operate below the target uncertainty stated for a dynamic generator of gas mixtures down to 100 Pa pressure drop. Stability gives the main contribution to total uncertainty at very short operation times, while calibration uncertainty gives the main contribution to total uncertainty at normal operation times. The calibration uncertainty at 0.1% is low enough to assure the target uncertainty for operation times over 10 s. Daily verification of calibration enhances the reliability of the measurement. An accurate voltmeter is necessary for the reproducibility of the set point.  相似文献   

3.
The presented 3D-ball plate is used for testing machine tools with a workspace of 500 mm × 500 mm × 320 mm. The artefact consists of a 2D-ball plate which is either located by a kinematic correct coupling on a base plate or on a spacer. The spacers are placed between the base plate and the ball plate and are also kinematic coupled to the other elements of the artefact. The kinematic couplings provide a high repeatability of the measurement setup. Because of the specific application the known calibration procedures for 2D-ball plates are not applicable.A calibration method for the pseudo-3D-artefact on a coordinate measuring machine (CMM) is presented, with the aim to minimise the influence of geometric CMM errors. Therefore a computer simulation is used to analyse the effects of these disturbing errors on the calibration of the ball plate and the spacers. Using a reversal method, the plate is measured at four different horizontal positions after rotating the ball plate around its vertical axis. A couple of the CMM errors, e.g., a squareness error C0Y between the X- and Y-axis of the CMM, can be eliminated by that method—others have to be determined with additional measurements, e.g., the positioning errors EXX or EYY of the X- and Y-axis, respectively. The paper also contains a measurement uncertainty estimation for the calibration by use of experiments, tolerances and Monte Carlo-simulations. The achieved uncertainty for ball positions in the working volume is less than 2.1 μm (coverage factor k = 2).  相似文献   

4.
The measurement principle of vortex flowmeter is based on von Karman vortex shedding phenomenon. Frequency of vortices, behind the bluff body, is proportional to the mean flow velocity. There are different ways of detection of vortices, and different sensors are used (presser sensors, capacitive sensors, thermo-resistance sensors, ultrasonic sensors, etc.). Proposed method to vortex identification, presented in this paper is based on simultaneous detection of pair of vortices with opposite circulation, by means of two pairs of ultrasonic transducers. A beam of ultrasound, from ultrasonic transmitter to ultrasonic receiver is transmitted perpendicularly to the vortex street. The received ultrasonic signal is amplitude and phase modulated. Frequency of demodulated signal is equal to the frequency of vortices. This technique allows a number of advantages comparing to conventional solutions: reduction, or elimination of noises caused by installation vibration and disturbances in the flow, higher sensor sensitivity, which as a result leads to a possibility of a reduction of the bluff body size, i.e. reduction of the pressure drop on the flow meter, increase of the measurement range in the low flow region, the possibility of redundant operation of the flow meter, reduced measurement uncertainty, instrument technology improvements, improved reliability of the instrument, assured improved statement of complete uncertainty contributions, improved metrology of the equipment as such and calibration procedures that contribute to measuring capabilities etc. For experimental testing a prototype vortex flowmeter of a nominal inner diameter (ID) 50 mm is developed. A cylindrical bluff body for vortex shedding is used. Ultrasonic transducers based on piezo-crystal PZT-5A, inserted in the wall of the vortex meter casing are utilized. The testing of prototype ultrasonic vortex flowmeter is realized on the calibration station on the water. The results at the testing point to the possibility of measuring flow of liquid fluids at velocities less than 0.5 m/s, with an uncertainty better than ±1%.  相似文献   

5.
We report on the design, construction and evaluation of a low-cost digital environmental monitoring system based on a popular micro-computer board and mass market digital sensors. The system is based around the use of open source software and readily available digital sensors, providing key parameters required for environmentally-controlled calibration laboratories: air temperature, pressure and humidity. Each system logs data at set intervals with front-panel display, web page graphical display and email alerting when exceeding set tolerances. The sensors have been calibrated at the National Physical Laboratory using standards traceable to the SI. Long term stability of the system is estimated and in addition to monitoring of laboratory environments for regulatory purposes, the systems can also be used to provide on-demand values for local refractive index with an expanded (k = 2) uncertainty of 1.1 × 10−7 as required for many optical-based measuring systems.  相似文献   

6.
Machine tool calibration is becoming recognised as an important part of the manufacturing process. The current international standards for machine tool linear axes calibration support the use of quasi-static calibration techniques. These techniques can be time consuming but more importantly a compromise in quality due to the practical restriction on the spatial resolution of target positions on the axis under test. Continuous motion calibration techniques have the potential to dramatically increase calibration quality. Through taking several measurement values per second while the axis under test is in motion, it is possible to measure in far greater detail. Furthermore, since machine tools normally operate in dynamic mode, the calibration data can be more representative if it is captured while the machine is in motion. The drawback to measuring the axis while in motion is the potential increase in measurement uncertainty. In the following paper, different methods of continuous motion calibration are discussed. A time-based continuous motion solution is proposed as well as a novel optimisation and correlation algorithm to accurately fuse the data taken from quasi-static and continuous motion measurements. The measurement method allows for minimal quasi-static measurements to be taken while using a continuous motion measurement to enhance the calibration process with virtually no additional time constraints. The proposed method does not require any additional machine interfacing, making it a more readily accessible solution for widespread machine tool use than other techniques which require hardware links to the CNC. The result of which means a shorter calibration routine and enhanced results. The quasi-static and continuous motion measurements showed correlation to within 1 μm at the quasi-static measurement targets. An error of 13 μm was detailed on the continuous motion, but was missed using the standard test. On a larger, less accurate machine, the quasi-static and continuous motion measurements were on average within 3 μm of each other however, showed a standard deviation of 4 μm which is less than 1% of the overall error. Finally, a high frequency cyclic error was detected in the continuous motion measurement but was missed in the quasi-static measurement.  相似文献   

7.
Quality control in advanced manufacturing requires automated and high-accuracy large-scale 3D measurement. This paper proposes a high-accuracy, low-cost 3D scanning system by integrating industrial robot with precise linear rail and laser sensor. The measuring principle and system construction of the integrated system are introduced in detail. A mathematical model is established for mapping the change of the laser sensor frame while it scans along the linear rail and a sphere-based algorithm for rail orientation calibration is introduced. Subsequently, taking the robot positioning error into consideration, an enhanced hand–eye calibration method is proposed to determine the relationship between robot end-effector and rail scanning frame. Validation experiments were performed, a maximum distance error of 0.071 mm was detected within the rail range and a mean/maximum distance error of 0.309/0.604 mm was detected in the robot volume. A large-scale scanning instance also shows that integrated robotic scanning system features high-efficiency and high-accuracy.  相似文献   

8.
《Measurement》2007,40(7-8):741-745
In this paper, we investigate the characteristics of a piezoresistive AFM cantilever in the range of 0–1.6 μN by using nano force calibrator (NFC), which consists of a high precision balance with resolution of 1 nN and 1-D fine positioning stage. Brief modeling of the cantilever is presented and then, the calibration results are shown. Tests revealed a linear relationship between the probing force and sensor output (resistance change), but the force vs. deflection is not as linear as the force vs. sensor output curve. The force constant of the cantilever was measured to 0.26 N/m with a standard deviation of 0.01 N/m. It shows that there is big difference between measured and nominal spring constant of 1 N/m provided by the manufacturer’s specifications.  相似文献   

9.
The present paper describes a moving permanent magnet linear synchronous motor (MPM LSM) that can move with an acceleration above 100 G (=980 m/s2), and is also capable of high-precision and high-speed positioning. The MPM LSM consists of a mover including permanent magnets and a double-sided electromagnet stator. It can produce a thrust of 4.56 × 103 N and has a working range wider than 1 m. The MPM LSM mover is improved for light weight and is driven using a suitable phase lead for flux weakening. The combination of the improved mover and the suitable phase lead provides motion at an acceleration above 100 G and a velocity above 12 m/s. The positioning characteristics of the improved MPM LSM are examined using a controller with two suitable phase lead functions. The control system shows a positioning accuracy and a positioning resolution of 500 nm, which is similar to the vibration amplitude of the sensor output in open loop. In 300-mm step positioning, the improved MPM LSM shows an acceleration above 660 m/s2 and a velocity above 8.3 m/s. It takes less than 101 ms to reduce the positioning error to less than 5 μm. The temperature rise during positioning is also examined experimentally. Continuous positioning for longer than 30 minutes increases the temperature of the MPM LSM, but by less than 6 °C.  相似文献   

10.
Quantitative measurement of hand kinematics can help us to better understand pathophysiological aspects of finger neural control and quantify hand impairments. A sensor glove was developed based on resistive bend sensors and resistive force sensors to monitor finger joint angles and forces exerted to objects by fingers. The validity and reliability of the glove were evaluated. A novel method was proposed to visualize and quantify the abnormality of the inter-joint coordination. The validity test indicated that the accuracy error of measuring joint angles was approximately ±6° and that of measuring forces was approximately ±8 g. The reliability test yielded an intraclass correlation coefficient of 0.9876 ± 0.0058 for the force sensors and 0.9561 ± 0.0431 for the bend sensors. The stability, accuracy and reliability of measuring joint angles were comparable with previous studies. The involvement of force sensors and the capacity of reflecting inter-joint coordination make the glove more comprehensive for hand function assessment.  相似文献   

11.
Large-scale rotors in the paper and steel industry are called rolls. Rolls are reground at regular intervals and roundness measurements are made throughout the machining process. Measurement systems for roundness and diameter variation of large rolls (diameter <2000 mm) are available on the market, and generally use two to four sensors and a roundness measurement algorithm. These methods are intended to separate roundness of the rotor from its movement. The hybrid four-point method has improved accuracy, even for harmonic component amplitudes. For reliable measurement results, every measurement should be traceable with an estimation of measurement uncertainty. In this paper, the Monte-Carlo method is used for uncertainty evaluation of the harmonic components of the measured roundness profile under typical industrial conditions. According to the evaluation, the standard uncertainties for the harmonic amplitudes with the hybrid method are below 0.5 μm for the even harmonics and from 1.5 μm to 2.5 μm for the odd harmonics, when the standard uncertainty for the four probes is 0.3 μm each. The standard uncertainty for roundness deviation is 3.3 μm.  相似文献   

12.
A portable device for calibration of trace humidity sensors and an adopted calibration procedure have been developed. The calibration device is based on humidity generation by permeating water through polymeric membrane tubes. Water vapour transmission rates for various polymers were experimentally determined in order to select the most suitable polymeric material. The developed trace humidity generator consists of a gas-flow polymeric hose immersed in a water reservoir thermostated by a sensor-controlled heater. Mole fractions of water vapour between 1 μmol mol−1 and 350 μmol mol−1 (equivalent to frost-point temperatures from −76 °C to −31 °C) were generated by varying either the operating temperature or gas flow. The operating temperature can be varied from 20 °C to 60 °C and kept stable within 0.1 K. Uncertainty analysis indicated that the trace humidity generator produces gas flows of constant humidity amounts with a relative expanded uncertainty less than 3.4% (k = 2) of the generated value.  相似文献   

13.
This paper presents cross-coupling effect of a polymer-based large range XY nanopositioner fabricated by an additive manufacturing (AM) process, stereolithography. The flexural properties were preliminary characterized to design the XY stage capable of ±1.0 mm range motion. The voice coil motors were aligned along the moving axes of the stage, and optical knife edge displacement sensors were placed at the center of the stage without Z-axis offset distance perpendicular to the moving axes to mitigate Abbe error and minimize cosine error. The cross-coupling of AM stage was 3.4% and 8.1% for XY and YX axes that is relatively larger than the value 1.0% estimated by the finite element method. It was considered to be responsible for AM fabrication tolerance or local irregularity in material properties because those properties are highly dependent on curing temperature and time even though the stage is fabricated layer-by-layer under the identical condition. The AM stage thus should be positioning feedback-controlled to avoid cross-coupling effect. As a result, the root-mean-square radial trajectory error was 3.62 μm under radius 1.0 mm and 1 Hz circular motion condition. These results indicated that the AM stages can be used for large range nanoprecision applications such as scanning, lithography, or fiber-optics alignments.  相似文献   

14.
Wireless sensors have become a focus of study in the field of measurement technologies. The power supply of many wireless sensors is based on batteries or external power sources. However, there is increasing interest in finding solutions where the batteries can be leaved away and the power for the wireless sensors is produced from the environment in which the sensors operate. The technologies required are called energy harvesting or scavenging technologies.This paper introduces the principles, modeling and a practical implementation of a self-powering solution for a wireless sensor for energy boilers or other hot reactor vessels. With the aid of energy solution introduced, the wireless sensor can operate autonomously without any batteries. One of the design targets in this work was that the top part of harvester’s mechanics must fit to the opening or assembly tube of diameter less than 15 mm in the boiler wall reserved for standard instrument assemblies. So the top of harvester collects and conducts thermal energy to element generating electricity from it. The harvester and further the measuring and communication electronics are mounted outside the hot area.The harvester solution introduced in the paper can produce about 114 mW power, when top of harvester mechanics was inserted to the test oven heated to temperature of +500 °C. The sensor function or type is not defined nor limited in this study. The electric energy generated by harvester can be used to power, for example, temperature, heat flux, flow, vibration or other little energy needing sensors.  相似文献   

15.
Two miniaturized liquid film sensors (MLFS) based on electrical conductance measurement have been developed and tested. The sensors are non-intrusive and produced with materials and technologies fully compatible and integrable with standard microfluidics. They consist of a line of 20 electrodes with a purpose-designed shape, flush against the wall, covering a total length of 5.00 and 6.68 mm. The governing electronics achieve 10 kHz of time resolution. The electrode spacing of the two sensors is 230 μm and 330 μm, which allows measurements of liquid films up to 150 μm and 400 μm for sensors MLFSA and MLFSB, respectively. The sensor characteristics were obtained by imposing static liquid films of known thickness on top of the actual sensor. Further dynamic measurements of concurrent air-water flow in a horizontal microchannel were performed. The line of electrodes is placed across the flow direction with an angle of 3.53° from the direction of flow, allowing for a spatial resolution perpendicular to the flow of 14.2 μm for sensor MLFSA and 20.5 μm for sensor MLFSB. The high time and spatial resolution allows for fast and accurate detection of the presence of bubbles, and even measurement of film thickness and bubble velocity. Further information, such as the bubble shape, can be gathered based on the shape of the liquid layer underneath the bubble, which is particularly important for heat transfer studies in microchannels.  相似文献   

16.
Structural health monitoring (SHM) technique is increasingly used in civil engineering structures, with which the authentic environmental and structural response data can be obtained directly. To get accurate structural condition assessment and damage detection, it is important to make sure the monitoring system is robust and the sensors are functioning properly. When sensor fault occurs, data cannot be correctly acquired at the faulty sensor(s). In such situations, approaches are needed to help reconstruct the missing data. This paper presents an investigation on wind pressure monitoring of a super-tall structure of 600 m high during a strong typhoon, aiming to compare the performance of data reconstruction using two different neural network (NN) techniques: back-propagation neural network (BPNN) and generalized regression neural network (GRNN). The early stopping technique and the Bayesian regularization technique are introduced to enhance the generalization capability of the BPNN. The field monitoring data of wind pressure collected during the typhoon are used to formulate the models. In the verification, wind pressure time series at faulty sensor location are reconstructed by using the monitoring data acquired at the adjacent sensor locations. It is found that the NN models perform satisfactorily in reconstructing the missing data, among which the BPNN model adopting Bayesian regularization (BR-BPNN) performs best. The reconstructed wind pressure dataset has maximum root mean square error about 23.4 Pa and minimum correlation coefficient about 0.81 in reference to the field monitoring data. It is also shown that the reconstruction capability of the NN models decreases as the faulty sensor location moves from center to corner of the sensor array. While the BR-BPNN model performs best in reconstructing the missing data, it takes the longest computational time in model formulation.  相似文献   

17.
With recent development in advanced manufacturing, demand for nanometric accuracy in dimensional metrology has increased dramatically. To satisfy these requirements, we propose a high-accuracy micro-roundness measuring machine (micro-RMM) using a multi-beam angle sensor (MBAS). The micro-RMM includes three main parts: the MBAS, a rotary unit, and a bearing system. The MBAS has been designed and established in order to improve motion accuracy of the micro-RMM. The dimensions of the MBAS are 125(L) mm × 130(W) mm × 90(H) mm. Compared with other methods, an MBAS is less susceptible to spindle error (stage-independence) when detecting angles, can maintain high sensitivity with miniaturized size, and can be used conveniently at the factory level. The optical probe, reported in this paper, is based on the principle of an autocollimator, and the stability is improved when using the MBAS. Unlike multi-probe methods, the micro-RMM is constructed to realize roundness measurement by using only one probe, which is less susceptible to instrumental errors. Experimental results confirming the feasibility of the multi-beam angle sensor for roundness measurement are also presented.  相似文献   

18.
A completely newly designed multi-functional facility for the primary calibration of reference solar cells and the spectral characterization of all solar cell types has been developed and built at PTB. The new facility is based on the successfully applied Differential Spectral Responsivity (DSR) method that allows the determination of the absolute spectral responsivity and nonlinearity of solar cells with the lowest uncertainties. By using a tunable laser system, the new setup avoids the main problem of monochromator-based systems: the low optical power level of the monochromatic beam. Thus it enables a significant reduction of the uncertainty for the short circuit current under standard test conditions ISTC of solar cells. It enables the calibration of World Photovoltaic Scale (WPVS) reference solar cells with an uncertainty of 0.4% (k = 2), the lowest value stated by any WPVS laboratory.  相似文献   

19.
This paper presents the design and calibration of an ISO non-compliant orifice plate flowmeter whose intended use is for respiratory function measurements in the bidirectional air flow range ±9 L/min.The novelty of the proposed sensor consists of a plate beveled in both upstream and downstream sides: a symmetrical geometry is adopted in order to perform bidirectional measurements of flow rate. A mathematical model is introduced to quantify the influence of temperature on the sensor output. Four different positions of the pressure static taps are evaluated in order to maximize bidirectionality. An index is also introduced in order to quantitatively estimate the anti-symmetry of the sensor's response curve.Trials are carried out to evaluate the influence on sensor output of air temperatures (22 °C, 30 °C and 37 °C) at different values of relative humidity (5%, 55% and 85%). Experimental data show a quite good agreement with the theoretical model (R2>0.98 in each condition).The influence of air temperature on the sensor output is minimized by introducing a correction factor based on the theoretical model leading to measurement repeatability better than 2% in overall range of calibration. The mean sensitivity in the calibration range is about 2 kPa L−1·min allowing to obtain a sensor discrimination threshold lower than 0.2 L/min in both directions. The time constant of the whole measurement system, equal to 2.40±0.03 ms, leads to a bandwidth up to 80 Hz making the sensor suitable for respiratory function measurements.  相似文献   

20.
Cost-effective velocity measurements at lab and field scales are required for understanding and modeling the flow characteristics in aquatic environments such as constructed wetlands, coastal marshes, lakes and reservoirs. This paper presents a new measurement device—the automatic pulse tracer velocimeter (APTV) that is designed to measure water velocities for low flow regimes (0.2–5.0 cm s−1) in heterogeneous aquatic environments using NaCl pulse tracer measurements. Hydraulic data collected in a laboratory-scale flume and field-scale constructed wetland were analyzed to determine velocity, directional flow and dispersion coefficients measured by using a cross-type and arc-type APTV. Acoustic Doppler velocimeters (ADVs) were used to collect calibration measurements in a hydraulic flume to gain fundamental understanding in support of field experiments. To test the effects of vegetation, four scenarios of laboratory-scale tests having both submerged and emergent artificial vegetation were conducted in a flume including; (1) no artificial vegetation (NAV), (2) submerged artificial vegetation (SAV) (3) emergent artificial vegetation (EAV), and (4) mix artificial vegetation (MAV). Directional flow detection and simulated storm event flow tests were conducted using an arc-type APTV data in the flume to gain perspectives of APTV performance in variable flow conditions. Cross-type APTV pulse data were eventually analyzed to determine dispersion coefficients based on the tracer curves. Finally APTVs were tested alongside an ADV for a three-day duration in a constructed wetland nearby the Everglades, Florida. Operating advantages of the APTV compared to other similar sensors were summarized in the end to enhance the application potential. Results indicate that APTVs are ideal device for affordable measurements of velocities in a 0.2–4.5 cm s−1 range with the prediction of both velocity field, direction and dispersion coefficients, and capable of autonomous deployment and control in a sensor network.  相似文献   