1.
ICP-AES法测定氧化钕中14个稀土杂质元素   总被引:1,自引:0,他引:1       下载免费PDF全文
采用等离子光谱仪测定质量分数 99%~ 99 97%氧化钕中 14个稀土杂质 ,选择了仪器的最佳工作条件。在选定条件下 ,14个稀土元素的检出限为 0.14~ 9 8μg/ g ,加标回收率为 86%~ 112 %。在体系中加入一定量乙醇后 ,可改善稀土元素的检出限。方法简单、快速、准确 ,精密度好 ,已用于产品的检测  相似文献   

2.
为准确测定粉煤灰中伴生铈(Ce)、钕(Nd)元素含量,本文采用氢氟酸-高氯酸-盐酸三元体系消解溶样,通过ICP-OES(电感耦合等离子体发射光谱仪)进行分析检测。通过研究粉煤灰样品溶样方法、优化分析测试谱线以及去除干扰等方法,无需进行样品基体匹配,即可实现粉煤灰伴生有价稀土元素Ce、Nd含量的测定。分析结果表明,该方法测定粉煤灰中稀土元素Ce、Nd含量的检出限分别为1.4μg/g、0.9μg/g,两个粉煤灰样Ce、Nd元素测试的精密度RSD值分别为0.02%~1.34%,0.11%~0.87%,加标回收率分别为96.2%~108.5%,93.2%~105.7%。研究表明,采用ICP-OES分析法测定粉煤灰中伴生有价稀土元素Ce、Nd,具有基体效应小、分析准确度高、操作快速简单、测试效率高的优点。  相似文献   

3.
基于电感耦合等离子体质谱法(ICP-MS)在稀土元素分析方面的优势,以HCl、HNO3、HF和HClO4溶解样品,控制He气流量为4.70 mL/min,实现了动能歧视碰撞池(KED)-ICP-MS对磷灰石样品中稀土元素分量和总量的测定。通过选择合适的同位素避免了质谱干扰;通过稀释基体质量浓度不大于0.25 mg/mL和选择45 ng/mL185Re为内标进行校正相结合的方法消除了非质谱干扰。实验表明,在选定的实验条件下,各稀土元素在0~100 ng/mL范围内与其对应的质谱强度呈良好的线性关系,校准曲线相关系数r为0.999 0~0.999 9,方法检出限为0.000 1~0.019 2 ng/mL。将实验方法应用于磷灰石实际样品中稀土元素分量和总量的测定,所得结果的相对标准偏差(RSD,n=6)为1.1%~4.7%,加标回收率为96%~109%。  相似文献   

4.
建立了同时测定中药颗粒剂及中草药中16种稀土元素的微波消解—ICP-MS法。结果表明:采用此法测定各稀土元素,线性相关性极好,加标回收率为93.04%~106.91%,RSD为1.23%~5.91%;方法操作简单,快速,准确,用于中药颗粒剂及中草药中稀土元素的同时测定,效果较好。  相似文献   

5.
基于电感耦合等离子体质谱法(ICP-MS)测定稀土元素的优势,在优化仪器工作参数的基础上,探究了敞口混合四酸法(HNO3-HCl-HF-HClO4)、敞口混合五酸法(HNO3-HCl-HF-HClO4-H2SO4)和高压密闭法(HNO3-HCl-HF)3种溶样方法对ICP-MS测定岩石和土壤中稀土元素的影响。结果表明:敞口混合四酸法因样品消解不完全不适宜用于ICP-MS测定岩石和土壤中稀土元素;敞口混合五酸法和高压密闭法均可以实现ICP-MS对岩石和土壤中稀土元素的测定;敞口混合五酸法结合ICP-MS测定稀土元素的方法检出限为0.001~0.035μg/g,相对标准偏差为1.4%~6.4%,相对误差在±9%范围内,加标回收率为92%~110%;高压密闭溶样法的检出限为0.001~0.009μg/g,相对标准偏差为1.0%~9.2%,相对误差在±4%范围内,加标回收率为93%~107%。敞口混合五酸法具有处理流程短的优点,适用于大批量样品处理;高压密闭溶样法具有检出限低,测试精度高及用酸量少等特点,但处理流程长不适用于大批量样品处理。  相似文献   

6.
准确测定稀土元素含量,对是否开采含难熔金属岩石的矿山中稀土元素具有重要指导意义。实验采用Na2O2在750℃马弗炉中熔融样品,熔融体冷却后用盐酸(1+4)转入烧杯中,往溶液中加入氨水,以样品做载体,共沉淀分离除去钠盐及能与氨水形成络氨离子的金属元素,沉淀物用稀氨水洗涤、热稀盐酸溶解,以电感耦合等离子体原子发射光谱法(ICP-AES)测定试液中La、Ce、Sm、Eu、Gd、Tb、Ho、Er、Dy、Tm、Yb、Y,建立了含难熔金属岩石中12种稀土元素的测定方法。各元素校准曲线的线性范围为0.10~25μg/mL,方法的检出限0.20~1.0μg/g。按照实验方法测定含难熔金属岩石物料中La、Ce、Sm、Eu、Gd、Tb、Ho、Er、Dy、Tm、Yb、Y等12种稀土元素,结果的相对标准偏差(RSD,n=9)为3.2%~6.2%,加标回收率为90%~110%。实验方法可用于含难溶金属岩石中稀土元素含量为0.001%~0.50%(质量分数)的测定。  相似文献   

7.
准确测定稀土元素含量,对是否开采含难熔金属岩石的矿山中稀土元素具有重要指导意义。实验采用Na2O2在750℃马弗炉中熔融样品,熔融体冷却后用盐酸(1+4)转入烧杯中,往溶液中加入氨水,以样品做载体,共沉淀分离除去钠盐及能与氨水形成络氨离子的金属元素,沉淀物用稀氨水洗涤、热稀盐酸溶解,以电感耦合等离子体原子发射光谱法(ICP-AES)测定试液中La、Ce、Sm、Eu、Gd、Tb、Ho、Er、Dy、Tm、Yb、Y,建立了含难熔金属岩石中12种稀土元素的测定方法。各元素校准曲线的线性范围为0.10~25μg/mL,方法的检出限0.20~1.0μg/g。按照实验方法测定含难熔金属岩石物料中La、Ce、Sm、Eu、Gd、Tb、Ho、Er、Dy、Tm、Yb、Y等12种稀土元素,结果的相对标准偏差(RSD,n=9)为3.2%~6.2%,加标回收率为90%~110%。实验方法可用于含难溶金属岩石中稀土元素含量为0.001%~0.50%(质量分数)的测定。  相似文献   

8.
南昌耐火材料厂研制成功一种体积密度小、力学强度高、导热系数低的新型高效轻质耐火砖。这种高强度轻质耐火砖是以漂珠为主要原料(从电厂废弃的粉煤灰中分离出  相似文献   

9.
粉煤灰是一种宝贵的铀资源,为了满足我国日益增长的核电对铀的需求,必须加大对粉煤灰中铀的综合回收利用,因此准确测定粉煤灰中铀含量意义重大。采用HNO3-HF-HClO4体系微波消解样品,选择187Re为内标元素,238U为铀测定同位素,建立了微波消解-电感耦合等离子体质谱法(ICP-MS)准确快速测定粉煤灰中铀的分析方法。对溶样条件进行了优化,确定溶样酸用量为5.0mL HNO3、3.0mL HF、0.50mL HClO4,消解程序如下所示:消解功率为800W,15min从室温升到150℃,保温10min,15min从150℃升到200℃,保温30min。实验表明,当铀的质量浓度范围为0.5~20ng/mL时,铀的质量浓度与其对应的信号强度呈线性关系,线性相关系数为0.9999,方法检出限为0.05μg/g。将实验方法应用于粉煤灰实际样品分析,测定结果的相对标准偏差(RSD,n=6)为3.2%,加标回收率为95%~104%。选取来自不同地方燃煤电厂的粉煤灰,按照实验方法进行铀的测定,并与激光荧光法进行对比,两种方法测定结果基本一致。  相似文献   

10.
采用火焰原子吸收光谱法(FAAS)与电感耦合等离子体原子发射光谱法(ICP-AES)两种方法对仿真饰品中铅、镉进行了测定,系统地考察了两种分析方法的校准曲线、相关系数、检出限、准确度和精密度。实验结果显示两种方法均可以对仿真饰品中铅、镉进行准确的定量分析。FAAS光谱干扰小,能够有效地规避仿真饰品溶液中高浓度铁基体对铅、镉测定的干扰,对基体复杂的仿真饰品的测定不需要基体匹配就可实现准确的分析测定,其中铅的检出限为0.000 975%,加标回收率为93%~105%;镉的检出限为0.000 225%,加标回收率为95%~103%。ICP-AES对于高基体样品使用基体匹配法能够减少基体效应带来的误差,使分析结果准确,其中铅、镉的检出限分别为0.000 060 0%和0.000 023 5%,加标回收率分别为97%~102%和95%~104%。  相似文献   

11.
采用硝酸-氢氟酸-高氯酸混酸溶解试样,以电感耦合等离子体质谱法(ICP-MS)对试样溶解液进行测定,提出了以ICP-MS测定离子吸附型稀土矿中全相稀土总量的方法。对氢氟酸用量和测定液中硝酸的含量进行了考察,最终确定氢氟酸用量为5.0mL,测定液介质为体积分数为2%的硝酸。在优化的仪器条件下,15种单一稀土元素校准曲线的线性相关系数均大于0.9999,方法检出限为2.4μg/g。采用实验方法对稀土矿石国家标准物质GBW07158、GBW07160、GBW07161(用于标样制定的样品均采自江西省龙南离子吸附型稀土矿区)中的稀土总量进行测定,测定结果与认定值基本一致。将实验方法应用于稀土矿石国家标准物质GBW07159、GBW07160与离子吸附型稀土矿实际试样中稀土总量的测定,测得结果的相对标准偏差(RSD,n=11)为1.7%~3.1%。  相似文献   

12.
Coal and coal combustion byproducts can be considered as an alternative source of rare earth elements and yttrium (REY). The study of relationships between REY and other main coal properties could have several advantages such as estimating REY content of coal particles and designing beneficial extraction method. In this investigation, inter-correlations between REY content with coal parameters (proximate and ash elements) for a wide range of eastern Kentucky coal samples (708 records) were explored. Results demonstrate that zircon and monazite are the main source of heavy and light rare earth elements (HREE and LREE), respectively. Zr has the highest correlation with Y and Th has the strength relationship with Ce and La. In general, LREE have higher interaction with coal ash content in comparison with HREE. Results indicated that REY can be estimated quite satisfactorily by using their associated elements in coal ash.  相似文献   

13.
The advancement and increasing interests in green energy production and environmental protection technologies have spurred the demand for rare earth elements.On the other hand,the U.S.has to rely 100% on import of these materials as the industry was crashed because of the environmental issues associated with mining and processing,and more importantly lack competitiveness.As rare earth elements have many applications in defense and national security sectors,some of the elements were listed as strategic materials or critical materials because of the uncertainties in supply and prices.Therefore,it has become imperative in searching for alternative resources for supplying rare earth elements including unconventional resources.With the strong incentive,coal fly ash is identified as one of the candidates among them.In this study,we present rare earth element data for the 42 ash samples(all derived from Powder River Basin coal) that we collected from seven states(UT,WY,10,WI,ND,CO,and MI) representing 158 million tons of fly ash.The results indicate scattered distributions of rare earth elements with concentration ranging from 156 to 590 ppm although all the ash samples originated from the same coal basin(Powder River Basin).The rare earth element resource in these ashes is estimated between 74000 and 106000 t.The ash samples were also characterized by elemental analysis,XRD,SEM-EDS and BET surface area.The characterizations of the ashes were discussed as they might have implications in the subsequent rare earth element extraction processes.In summary,fly ash may represent a potential resource for rare earth element production.  相似文献   

14.
建立了利用电感耦合等离子体原子发射光谱法(ICP-AES法)同时测定稀土镁铸铁中常量及痕量共12种元素(Si,Mn,P,Cu,Mo,V,Ti,Sn,Sb,Mg,La,Ce)的分析方法。研究了稀土镁铸铁试样的前处理方法、优选了适宜的仪器测定参数和分析谱线,采用基体匹配法进行基体效应的校正。实验结果表明,各元素分析谱线线性相关系数大于0.999 0,方法检出限在0.000 12%~0.001 4%之间。方法用于稀土镁铸铁标准物质分析,测定值与认定值相符,测定结果的相对标准偏差在0.59%(Si)~6.9%(La)范围。  相似文献   

15.
使用HNO3-HF混合酸体系微波消解煤飞灰样品,建立了电感耦合等离子体质谱法(ICP-MS)测定煤飞灰中14种痕量元素含量的分析方法。样品微波消解的程序为:0.2 g样品中加入10 mL HNO3和5 mL HF,5 min加热到110 ℃保持5 min、5 min升温到150 ℃保持5 min、5 min升至190 ℃恒温30 min。实验对较高浓度元素Be、Co、Cr、Cu、Mn、Mo、Ni、Pb、Sn、V和Zn采取稀释10倍、降低总溶解性固体(TDS)含量后以外标法进行测定,Cd、Sb、Tl等低含量元素则采用标准加入法以消除基体干扰;方法检出限为0.001~0.04 mg/kg。将实验方法应用于煤飞灰标准物质SRM 1633c中11种金属元素(Be、Cd、Co、Cr、Cu、Mn、Ni、Pb、Sb、V、Zn)的测定,结果与认定值基本一致,相对标准偏差(RSD,n=6)为0.3%~3.6%,加标回收率在83%~112%之间。采用实验方法测定煤飞灰实际样品的结果与12个实验室采用电感耦合等离子体原子发射光谱法(ICP-AES)、ICP-MS、原子吸收光谱法(AAS)、X射线荧光光谱法(XRF)和滴定法等其他方法测得结果的平均值对比,经t检验统计表明无显著性差异。  相似文献   

16.
作为稀土工业的原料,稀土精矿中稀土总量的测定方法步骤多、流程长。实验采用熔融制样-X射线荧光光谱法测定轻稀土精矿中稀土总量,研究了制样和测量条件。准确称取6.000 0g无水四硼酸锂和偏硼酸锂混合熔剂(质量比2∶1)于铂黄坩埚中,以0.500 0g硝酸锂为氧化剂消除试样中还原物质对铂黄坩埚的侵蚀,称取0.600 0g稀土精矿试样,再于试样表面均匀覆盖0.500 0g氧化硼防止试样喷溅,滴加0.5mL 20mg/mL的溴化铵溶液作为脱模剂。将坩埚放进预加热到1 050℃的熔样机内熔融19min制备样片,可消除矿物效应、粒度效应及表面效应。通过各稀土元素X射线荧光谱线的选择减少谱线干扰,以经验系数法校正谱线干扰和基体效应,用稀土精矿标样建立各稀土元素校准曲线。各组分校准曲线的相关系数在0.991~0.999之间,试样重复测量的相对标准偏差(RSD)小于0.5%,稀土总量测定结果与重量法一致。方法的精密度和正确度能够满足生产要求。  相似文献   

17.
钨矿石和钼矿石具有难熔的特征,常需要用碱熔法才能将其溶解完全,但若用碱熔法对样品进行前处理,样品溶液会因加入大量熔剂引入钠离子从而导致盐度过高进而造成基体干扰及锥孔堵塞,不利于电感耦合等离子体质谱法(ICP-MS)对其中痕量稀土元素进行测定。针对这一问题,实验提出了用NaOH和Na2O2高温熔融样品、热水提取后过滤的方法将稀土元素富集在稀土氢氧化物沉淀中,从而与大量的Na及K、W、Mo等金属离子分离,加入酒石酸-HCl体系溶解沉淀后稀释,可实现ICP-MS对钨矿石和钼矿石样品中稀土元素的测定。实验表明:称取0.500 0 g样品,加入3.0 g NaOH和1.5 g Na2O2,在马弗炉中于700 ℃熔融20 min可将样品分解完全;通过选择合适的同位素及数学校正方法可消除质谱干扰,以10 μg/L103Rh为内标可有效地监测和校正分析信号的漂移和基体效应。在优化的实验条件下,各元素校准曲线的相关系数均大于0.999 5,方法检出限为0.004~0.08 μg/g。采用实验方法对钼矿石和钨矿石成分分析标准物质中的稀土元素进行测定,结果与标准物质认定值对数误差(ΔlgC)的绝对值均小于0.1(地质矿产行业标准DZ/T 0130-2006的要求),相对标准偏差(RSD,n=6)小于5%。  相似文献   

18.
锆钛矿中存在耐高温且硬度高的锆和钛,常规酸溶法难以将其完全分解,碱熔法处理样品时样品易粘埚。采用碳酸钠-硼酸熔融样品,以50 ng/mL185Re为内标,动能歧视碰撞池(KED)模式和干扰系数校正法克服了轻稀土元素氧化物或氢氧化物对重稀土元素的干扰,建立了电感耦合等离子体质谱法(ICP-MS)测定锆钛矿中16种稀土元素(钪、钇、镧、铈、镨、钕、钐、铕、钆、铽、镝、钬、铒、铥、镱、镥)分量及其总量的分析方法。对比了盐酸-硝酸-氢氟酸-高氯酸敞开酸溶、硝酸-氢氟酸密闭酸溶、氢氟酸微波消解、过氧化钠-氢氧化钠熔融、硼砂熔融和碳酸钠-硼酸熔融6种分解方法,结果表明,碳酸钠-硼酸熔剂对样品分解的效果最佳。采用样品稀释法控制基体质量浓度为0.20 mg/mL和内标元素校正法降低基体效应。实验表明:各稀土元素的校准曲线线性相关系数在0.999 1~1.000 0之间,方法检出限为0.000 1~0.008 4 μg/g,定量限为0.000 5~0.042 0 μg/g。采用实验方法测定与锆钛矿成分类似的锆矿石标准样品中16种稀土元素分量及总量,结果与认定值基本一致。将实验方法应用于锆钛矿实际样品的测定,测定结果的相对标准偏差(RSD, n=8)为1.2%~4.0%,加标回收率为94%~110%,符合国家地质矿产行业标准DZ/T 0130—2006第3部分规定的加标回收率允许限90%~110%的范围。  相似文献   

19.
白云鄂博矿物为典型的晶格型矿物,含有铌、锆、钛等难溶金属的矿物,常规酸溶法处理难以将其溶解完全。采用氢氧化钠和过氧化钠碱熔融分解白云鄂博矿石样品,热水浸取,碱分离后,用盐酸和过氧化氢破坏滤纸和溶解沉淀,以1%盐酸为测定介质,通过控制基体质量浓度不大于0.5 g/L和采用Cs内标进行校正以消除基体效应,建立了电感耦合等离子体质谱法(ICP-MS)测定白云鄂博矿石中包括镧、铈、镨、钕、钐、铕、钆、铽、镝、钬、铒、铥、镱、镥、钇在内的15种稀土元素含量及其总量的方法。实验表明,各稀土元素在质量浓度为5.00~100.0 ng/mL(以氧化物计,下同)范围内和稀土元素与内标元素的强度比呈良好的线性关系,相关系数均不小于0.999 6。方法检出限为0.010~0.034 ng/mL,定量限为0.030~0.10 ng/mL。按照实验方法对白云鄂博矿石样品中稀土元素总量及其分量进行测定,测定结果与电感耦合等离子体原子发射光谱法或X射线荧光光谱法基本一致;相对标准偏差(RSD,n=6)在1.0%~4.9%之间,加标回收率在95%~105%之间。将实验方法应用于稀土矿石成分分析标准物质中稀土元素总量及其分量的测定,结果与认定值基本一致。  相似文献   

20.
白云鄂博矿物为典型的晶格型矿物,含有铌、锆、钛等难溶金属的矿物,常规酸溶法处理难以将其溶解完全。采用氢氧化钠和过氧化钠碱熔融分解白云鄂博矿石样品,热水浸取,碱分离后,用盐酸和过氧化氢破坏滤纸和溶解沉淀,以1%盐酸为测定介质,通过控制基体质量浓度不大于0.5 g/L和采用Cs内标进行校正以消除基体效应,建立了电感耦合等离子体质谱法(ICP-MS)测定白云鄂博矿石中包括镧、铈、镨、钕、钐、铕、钆、铽、镝、钬、铒、铥、镱、镥、钇在内的15种稀土元素含量及其总量的方法。实验表明,各稀土元素在质量浓度为5.00~100.0 ng/mL(以氧化物计,下同)范围内和稀土元素与内标元素的强度比呈良好的线性关系,相关系数均不小于0.999 6。方法检出限为0.010~0.034 ng/mL,定量限为0.030~0.10 ng/mL。按照实验方法对白云鄂博矿石样品中稀土元素总量及其分量进行测定,测定结果与电感耦合等离子体原子发射光谱法或X射线荧光光谱法基本一致;相对标准偏差(RSD,n=6)在1.0%~4.9%之间,加标回收率在95%~105%之间。将实验方法应用于稀土矿石成分分析标准物质中稀土元素总量及其分量的测定,结果与认定值基本一致。  相似文献   