首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
The use of histidine as a protein digestion buffer followed by isoelectric trapping separations using "membrane separated wells for isoelectric focusing and trapping" (MSWIFT) and mass spectrometry (MS) analysis is described. Tryptic digestion of bovine serum albumin (BSA) performed in histidine buffered solutions yields similar amino acid sequence coverage values to those obtained using ammonium bicarbonate buffer. Time course studies suggest that histidine buffers provide faster migration of peptides from the loading compartment compared to digestions prepared in ammonium bicarbonate due to differences in conductivities of the two buffers. In addition, this sample preparation method and MSWIFT separations have been coupled with capillary electrophoresis (CE) and matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) as an alternative separation approach for proteomic studies. Tryptic peptides of ribosomal proteins in histidine are fractionated using MSWIFT followed by CE-MALDI-MS, which further illustrates the ability to couple fractions from a pI based separation device to CE-MS. Specifically, two-dimensional CE-MS plots provide a direct correlation between the numbers of basic residues within the peptide sequence displayed in charge-state trend lines. Combining MSWIFT and CE-MS provides added information regarding peptide sequence, specifically pI and in-solution charge state. Post-translational modifications can also be identified using this method.  相似文献   

2.
Wang YC  Choi MH  Han J 《Analytical chemistry》2004,76(15):4426-4431
Methods are described to achieve more efficient multidimensional protein separation in a microfluidic channel. The new methods couple isoelectric focusing (IEF) with high ionic strength electrophoretic separations by active microvalve control in a microchip. Several experiments demonstrating independent 2D separation were performed, and critical parameters for optimal chip performance were identified, including channel passivation, electroosmosis control, and IEF linearity control. This strategy can be used for integration of different heterogeneous separation techniques, such as IEF, capillary electrophoresis, and liquid chromatography. This new device can be ideal for preseparation and preconcentration of complex biomolecule samples for a streamlined biomolecule analysis using mass spectrometry.  相似文献   

3.
Extensive prefractionation is now considered to be a necessary prerequisite for the comprehensive analysis of complex proteomes where the dynamic range of protein abundances can vary from approximately 10(6) for cells to approximately 10(10) for tissues such as blood. Here, we describe a high-resolution 2D protein separation system that uses a continuous free-flow electrophoresis (FFE) device to fractionate complex protein mixtures by solution-phase isoelectric focusing (IEF) into 96 well-defined pools, each separated by approximately 0.02-0.10 pH unit depending on the gradient created, followed by rapid (approximately 6 min per analysis) reversed-phase high-performance liquid chromatography (RP-HPLC) of each FFE pool. Fractionated proteins are readily visualized in a virtual 2D format using software that plots protein loci, pI in the first dimension and relative hydrophobicity (i.e., RP-HPLC retention time) in the second dimension. By coupling a diode-array detector in line with a multiwavelength fluorescence detector, separated proteins can be monitored in the RP-HPLC eluent by both UV absorbance and intrinsic fluorescence simultaneously from a single experiment. Triplicate analyses of standard proteins using a pH 3-10 gradient conducted over a 3-day period revealed a high system reproducibility with a SD of 0.57 (0.05 pH unit) within the FFE pools and 0.003 (0.18 s) for protein retention times in the second-dimension RP-HPLC step. In addition, we demonstrate that the FFE-IEF/RP-HPLC separation strategy can also be applied to complex mixtures of low molecular weight compounds such as peptides. With the facile ability to measure the pH of the isoelectric focused pools, peptide pI values can be estimated and used to qualify peptide identifications made using either MS/MS sequencing approaches or pI discriminated peptide mass fingerprinting. The calculated peak capacity of this 2D liquid-based FFE-IEF/RP-HPLC system is 6720.  相似文献   

4.
A stepwise mobilization strategy has been developed for the elution of complex protein mixtures, separated by capillary isoelectric focusing (CIEF) for detection using on-line electrospray ionization mass spectrometry (ESI-MS). Carrier polyampholytes are used to establish a pH gradient as well as to control the electroosmotic flow arising from the use of uncoated fused-silica capillaries. Elution of focused protein zones is achieved by controlling the mobilization pressure and voltage, leaving the remaining protein zones focused inside the capillary. Protein zones are stepwise eluted from the capillary by changing the mobilization conditions. Stepwise mobilization improves separation resolution and simplifies coupling with multistage MS (i.e., MSn) analysis since it allows more effective temporal control of protein elution from the CIEF capillary. We also describe a modified configuration for coupling CIEF with ESI-MS using a coaxial sheath flow interface that facilitate the automation of on-line CIEF-ESI-MS analyses. The stepwise mobilization strategy is demonstrated for the analysis of standard protein mixtures and soluble E. coli lysate proteins using CIEF-ESI-MS. These results indicate that inlet pressure or voltage programming to control the elution of the protein zones from the capillary (i.e., gradient mobilization) may allow for the optimization of the mobilization conditions and provide higher resolution for CIEF separation of complex mixtures with on-line MS.  相似文献   

5.
Microfluidic high-resolution free-flow isoelectric focusing   总被引:1,自引:0,他引:1  
A microfluidic free-flow isoelectric focusing glass chip for separation of proteins is described. Free-flow isoelectric focusing is demonstrated with a set of fluorescent standards covering a wide range of isoelectric points from pH 3 to 10 as well as the protein HSA. With respect to an earlier developed device, an improved microfluidic FFE chip was developed. The improvements included the usage of multiple sheath flows and the introduction of preseparated ampholytes. Preseparated ampholytes are commonly used in large-scale conventional free-flow isoelectric focusing instruments but have not been used in micromachined devices yet. Furthermore, the channel depth was further decreased. These adaptations led to a higher separation resolution and peak capacity, which were not achieved with previously published free-flow isoelectric focusing chips. An almost linear pH gradient ranging from pH 2.5 to 11.5 between 1.2 and 2 mm wide was generated. Seven isoelectric focusing markers were successfully and clearly separated within a residence time of 2.5 s and an electrical field of 20 V mm-1. Experiments with pI markers proved that the device is fully capable of separating analytes with a minimum difference in isoelectric point of Delta(pI) = 0.4. Furthermore, the results indicate that even a better resolution can be achieved. The theoretical minimum difference in isoelectric point is Delta(pI) = 0.23 resulting in a peak capacity of 29 peaks within 1.8 mm. This is an 8-fold increase in peak capacity to previously published results. The focusing of pI markers led to an increase in concentration by factor 20 and higher. Further improvement in terms of resolution seems possible, for which we envisage that the influence of electroosmotic flow has to be further reduced. The performance of the microfluidic free-flow isoelectric focusing device will enable new applications, as this device might be used in clinical analysis where often low sample volumes are available and fast separation times are essential.  相似文献   

6.
A miniaturized ion sprayer device is described which is suitable for coupling with chip-based analytical separation devices, multiwell plates, or surfaces containing residues of prepared samples. Two versions of a similar device are described. A "microsprayer" device suitable for coupling to the terminal edge of a capillary electrophoresis (CE) chip is constructed from modified 1/16-in. HPLC fittings. This microsprayer employs a free-standing liquid junction formed via continuous delivery of a flow (2-6 microL/min) of suitable solvent which carries the CE effluent through a pneumatically assisted electrospray (ion spray) needle positioned in front of an atmospheric pressure ionization (API) mass spectrometer. A related but larger "minisprayer" device is also described which employs the same features as the microsprayer, but with an extended sampling capillary tube which can reach into the depths of 96-, 384-, and 1536-multiwell plates containing either sample solutions or dried sample residues. The minisprayer may be positioned in front of an API ion sampling orifice and the multiwell plate positioned stepwise from sample to sample for analysis of trace samples contained in the wells. The resulting infusion-ion spray mass spectrometric analyses can provide sequential analysis of previously prepared biological samples containing small drug compounds, proteins, and related compounds. This same device is also shown to be useful for sampling from a surface containing trace level compounds of biological interest. Results are shown that demonstrate microscale separations and selected ion monitoring (SIM) capillary electrophoresis/mass spectrometry (CE/MS) detection of berberine and palmatine using the microsprayer. SIM ion spray determination of a 2 ng/microL solution of berberine contained as a dry residue in the bottom of a 384-well plate as well as full-scan electrospray mass spectra for low-picomole levels of cytochrome c contained in a 1536-well microtiter plate are shown. The respective micro- and minisprayer devices provide a simple yet effective means of transferring trace-level samples either from a microscale or chip-based separation device as well as samples contained in multiwell plates which are increasingly employed in high-throughput applications in the pharmaceutical industry.  相似文献   

7.
The development of an on-line automated SPE-HPLC--ESI-MS method is described for targeted metabolomic analysis of urinary modified nucleoside levels. The setup comprises a boronate affinity column as a trapping device, a hydrophilic interaction chromatography (HILIC) separation and information-dependent MS detection modes. The system was optimized using standards and tested on biological samples, detecting a number of modified nucleosides. Other urinary biomarkers could also be analyzed by the system developed: for example, the urinary nucleobases were also available for analysis. A simultaneous creatinine-monitoring experiment was also demonstrated to be viable when utilizing the method, which is of benefit as creatinine is a urinary normalizing factor.  相似文献   

8.
The large-scale identification of proteins from proteomes of complex organisms, and the availability of various types of protein and DNA databases, increasingly require the additional information provided by tandem mass spectrometry. HPLC and microLC coupled to ESI-MS/MS presently dominate the field of protein identification by tandem mass spectrometry and database searching. The analysis of protein digests is typically performed using HPLC or LC columns with 50-100-microm diameters, requiring the delivery of solvent gradients at low to mid nanoliter per minute flow rates. This has been typically achieved using expensive generic HPLC pumping systems for the delivery of microliter per minute gradients that were either flow-split or sampled. Here we present an alternative system for the delivery of nanoliter per minute gradients. The inexpensive nanoflow gradient generator (etagrad) described here can be modulated to reproducibly deliver selected gradients. The performance of the etagrad on-line with a microLC-ESI-MS/MS system has been demonstrated for the identification of standard protein digests. Moreover, the performance of the etagrad-microLC-ESI-MS/MS system, with protein prefractionation by IPG isoelectric focusing, was also evaluated for rapid study of yeast and human proteomes.  相似文献   

9.
Huang L  Riggin RM 《Analytical chemistry》2000,72(15):3539-3546
An HPLC/MS method has been developed that allows rapid, direct analysis of underivatized sialylated as well as neutral oligosaccharides. The method involves the separation of oligosaccharides from salts and proteins using RP-HPLC with a formic acid/acetonitrile/water mobile phase system and on-line electrospray mass spectrometry analysis in the positive ion mode. Under the solution conditions employed, both neutral and acidic (sialylated) oligosaccharides are protonated and therefore detected. In contrast to MALDI-TOF MS, no loss of sialic acid is observed when operating in the positive ion mode. Furthermore, the capability of this method to provide quantitative estimates of the relative abundance of each oligosaccharide mass has been demonstrated using fetuin as a model compound.  相似文献   

10.
Chen WY  Chen YC 《Analytical chemistry》2007,79(21):8061-8066
The presence of alkali cation adductions of oligonucleotides commonly deteriorates matrix-assisted laser desorption/ionization (MALDI) mass spectra. Thus, desalting is required for oligonucleotide samples prior to MALDI MS analysis in order to prevent the mass spectra from developing poor quality. In this paper, we demonstrate a new approach to extract traces of oligonucleotides from aqueous solutions containing high concentrations of salts using microwave-assisted extraction. The C18-presenting magnetite beads, capable of absorbing microwave irradiation, are used as affinity probes for oligonucleotides with the addition of triethylammonium acetate as the counterions. This new microwave-assisted extraction approach using magnetite beads as the trapping agents and as microwave-absorbers has been demonstrated to be very effective in the selective binding of oligonucleotides from aqueous solutions. The extraction of oligonucleotides from solutions onto the C18-presenting magnetite beads takes only 30 s to enrich oligonucleotides in sufficient quantities for MALDI MS analysis. After using this desalting approach, alkali cation adductions of oligonucleotides are dramatically reduced in the MALDI mass spectra. The presence of saturated NaCl (approximately 6 M) in the oligonucleotide sample is tolerated without degrading the mass spectra. The detection limit for d(A)6 is approximately 2.8 fmol.  相似文献   

11.
Direct mass spectrometric quantification of peptides and proteins is compromised by the wide variabilities in ionization efficiency which are hallmarks of both the MALDI and ESI ionization techniques. We describe here the implementation of a fluorescence detection system for measurement of the UV-excited intrinsic fluorescence (UV-IF) from peptides and proteins just prior to their exit and electrospray ionization from an ESI capillary. The fluorescence signal provides a quantifiable measure of the amount of protein or peptide present, while direct or tandem mass spectrometric analysis (MS/MS) on the ESI-generated ions provides information on identity. We fabricated an inexpensive, modular fluorescence excitation and detection device utilizing an ultraviolet light-emitting diode for excitation in a ~300 nL fluorescence detection cell integrated into the fused-silica separation column. The fluorescence signal is linear over 3 orders of magnitude with on-column limits of detection in the low femtomole range. Chromatographically separated intact proteins analyzed using UV-IF prior to top-down mass spectrometry demonstrated sensitive detection of proteins as large as 77 kDa.  相似文献   

12.
A novel microfabricated device was implemented for facile coupling of capillary electrophoresis with mass spectrometry (CE/MS). The device was constructed from glass wafers using standard photolithographic/wet chemical etching methods. The design integrated (a) sample inlet ports, (b) the separation channel, (c) a liquid junction, and (d) a guiding channel for the insertion of the electrospray capillary, which was enclosed in a miniaturized subatmospheric electrospray chamber of an ion trap MS. The replaceable electrospray capillary was precisely aligned with the exit of the separation channel by a microfabricated guiding channel. No glue was necessary to seal the electrospray capillary. This design allowed simple and fast replacement of either the microdevice or the electrospray capillary. The performance of the device was tested for CE/MS of peptides, proteins, and protein tryptic digests. On-line tandem mass spectrometry was used for the structure identification of the protein digest products. High-efficiency/high-resolution separations could be obtained on a longer channel (11 cm on-chip) microdevice, and fast separations (under 50 s) were achieved with a short (4.5 cm on-chip) separation channel. In the experiments, both electrokinetic and pressure injections were used. The separation efficiency was comparable to that obtained from conventional capillary electrophoresis.  相似文献   

13.
W Tong  A Link  J K Eng  J R Yates 《Analytical chemistry》1999,71(13):2270-2278
A method to directly identify proteins in complex mixtures by solid-phase microextraction (micro-SPE)/multistep elution/capillary electrophoresis (CE)/tandem mass spectrometry (MS/MS) is described. A sheathless liquid-metal junction interface is used to interface CE and electrospray ionization MS/MS. A subfemtomole detection limit is achieved for protein identification through database searching using MS/MS data. The SPE serves as a semiseparation dimension using an organic-phase step-elution gradient in combination with the second separation dimension for increased resolving power of complex peptide mixtures. This approach improves the concentration detection limit for CE and allows more proteins in complex mixtures to be identified. A 75-protein complex from yeast ribosome is analyzed using this method and 80-90% of the proteins in the complex can be identified by searching the database using the MS/MS data from a complete analysis. This multidimensional CE/MS/MS methodology provides an alternative to multidimensional liquid chromatography/MS/MS for direct identification of small amounts of protein in mixtures.  相似文献   

14.
A chip-based capillary electrophoresis/mass spectrometry (CE/MS) system is described for the on-chip separation and coupled electrospray detection of selected small drug molecule compounds. These studies include the quantitative determination of carnitine and acetylcarnitine in analytical standard solutions as well as imipramine and desipramine in fortified human plasma samples. A clinical human plasma sample was also analyzed following the normal administration of desipramine to a volunteer, and the parent drug was determined using the described chipbased CE/MS technique. In each instance, stable isotope-incorporated internal standards were used. The chip-based CE system was microfabricated from glass and coupled to a micro ion spray device constructed in-house. The atmospheric pressure ionization system employed in this work was a PE Sciex API III tandem triple quadrupole system operated in the selected ion monitoring (SIM) mode. The results from the work reported here demonstrate the feasibility for carrying out rapid (30 s) chipbased quantitative CE/MS determinations of samples containing small-molecule compounds. Using SIM CE/ MS techniques, the described API III quadrupole system provided acceptable ion current electropherograms from subpicomole levels of the targeted compounds loaded onto the chip. The corresponding electropherograms for the standard solution of carnitines at the 1-500 microg/mL level were obtained via SIM CE/MS techniques (R2 > 0.99). In addition, analyses of fortified samples of imipramine desipramine were measured relative to their corresponding d3 internal standards to obtain calibration curves ranging from 5 to 500 microg/mL in human plasma (R2 > 0.99). The intra-assay precision ranged from 4.1 to 7.3% RSD. The intra-assay accuracy ranged from 94.0 to 104%. These results demonstrate the feasibility for on-chip CE separation and electrospray mass spectrometric determination in applications for bioanalytical measurements for these important compounds in synthetic mixtures and human plasma extracts.  相似文献   

15.
Although well-established as a technique for protein purification, the application of continuous elution tube gel electrophoresis to proteome fractionation remains problematic. Difficulties associated with sample collection, particularly at the high mass range or at low sample loadings, continue to plague the technique. Furthermore, an upper mass limit is imposed as slow-moving higher molecular weight proteins are progressively diluted during the collection phase. In short, with current technology, effective separation over a broad mass range has not been achieved. In this work, we present improved techniques for continuous elution tube gel electrophoresis to accommodate broad mass range separation of proteins. Our device enables rapid partitioning of a proteome into discrete mass range fractions in the solution phase. High recovery is achieved at submicrogram to milligram sample loadings. We demonstrate comprehensive, reproducible separations of protein mixtures, as well as separation of a proteome in as fast as 1 h, over mass ranges from below 10 to 250 kDa. Finally, we identified proteins from a prefractionated standard protein mixture using liquid chromatography tandem mass spectrometric (LC-MS/MS) analysis.  相似文献   

16.
A preparative mass spectrometer for microarray fabrication is reported. The instrument includes an atmospheric pressure ionization source, a linear ion trap mass analyzer, an ion collection surface positioning system, and a surface loading chamber with independent vacuum pumping. It was designed for the production of protein arrays using the ion soft-landing technique to collect ions on a surface after separation by mass/charge ratio. Small microarrays have been prepared by isolating and soft landing individual protein or peptide ions after electrospray ionization of mixtures. The composition and purity of the separated materials has been confirmed using independent external mass spectrometric analysis of rinse solutions of the collected spots, either by the new method of electrosonic spray ionization MS or by nanospray ionization MS. The ability to retain bioactivity in the mass-selected and collected biomolecules has been demonstrated in particular cases. The reported instrument has also been characterized as an analytical mass spectrometer.  相似文献   

17.
Two-dimensional polyacrylmide gel electrophoresis (2D-PAGE), perhaps the most widely used method in proteomics research, is often limited by sensitivity and throughput. Capillary isoelectric focusing (CIEF) coupled with electrospray ionization (ESI) mass spectrometry (MS) provides a liquid-based alternative to 2D-PAGE that can overcome these problems but is limited by ampholyte interference and signal quenching in ESI-MS. Inserting a reversed-phase liquid chromatography (RPLC) step between CIEF and MS can remove this interference. In this work, a CIEF-RPLC-MS system is described for separation and characterization of proteins in complex mixtures. CIEF is performed with a microdialysis membrane-based cathodic cell that also permits protein fractions to be collected, washed to remove ampholyte, and analyzed by RPLC-MS. CIEF performance with this cell is equivalent to that achieved with a conventional cathodic cell, and no loss of protein is observed during faction collection. The cell can be easily and safely retrofitted into commercial instrumentation and is applicable for peptide analysis as well. Protein detection at the low-femtomole level is demonstrated with little or no interference from ampholyte, and CIEF-RPLC-MS data are used to construct a plot of pI vs MW for a protein mixture. The current instrumental configuration allows seven fractions in the pI range 3-10 to be analyzed by RPLC-MS in 2 h.  相似文献   

18.
Data-dependent acquisition of MS/MS spectra from lipid precursors enables to emulate the simultaneous acquisition of an unlimited number of precursor and neutral loss scans in a single analysis. This approach takes full advantage of rich fragment patterns in tandem mass spectra of lipids and enables their profiling by complex (Boolean) scans, in which masses of several fragment ions are considered within a single logical framework. No separation of lipids is required, and the accuracy of identification and quantification is not compromised, compared to conventional precursor and neutral loss scanning.  相似文献   

19.
X Jin  J Kim  S Parus  D M Lubman  R Zand 《Analytical chemistry》1999,71(16):3591-3597
The development of a system capable of the speed required for on-line capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) of tryptic digests is described. The ion trap storage/reflectron time-of-flight (IT/reTOF) mass spectrometer is used as a nonscanning detector for rapid CE separation, where the peptides are ionized on-line using electrospray ionization (ESI). The ESI produced ions are stored in the ion trap and dc pulse injected into the reTOF-MS at a rate sufficient to maintain the separation achieved by CE. Using methodology generated by software and hardware developed in our lab, we can produce SWIFT (Stored Waveform Inverse Fourier Transform) ion isolation and TICKLE activation/fragmentation voltage waveforms to generate MS/MS at a rate as high as 10 Hz so that the MS/MS spectra can be optimized on even a 1-2 s eluting peak. In CE separations performed on tryptic digests of dogfish myelin basic protein (MBP) where eluting peaks 4-8 s wide are observed, it is demonstrated that an acquisition rate of 4 Hz provides > 20 spectra/peak and is more than sufficient to provide optimized MS/MS spectra of each of the eluting peaks in the electropherogram. The detailed structural analysis of dogfish MBP including several posttranslational modifications using CE-MS and CE-MS/MS is demonstrated using this method with < 10 fmol of material consumed.  相似文献   

20.
Salt is abundant in biological samples and can cause problems in capillary electrophoresis (CE) due to excessive Joule heating and electrodispersion. Desalting with solid phase minibeds is currently most compatible with the small sample volumes of CE. They are however difficult to prepare and suffer from poor bed-to-bed reproducibility. Alternatively, enrichment of proteins and peptides was developed using CE, by trapping them at their isoelectric points with a discontinuous buffer of mismatched pH. Ionic salts, such as sodium chloride, do not possess isoelectric points and therefore are not retained by the discontinuous buffer. In this work, the removal of ionic salt during protein enrichment using CE with discontinuous buffers was investigated. Nonbuffering ions were found to electromigrate through the pH junction without disrupting the enrichment process and were eventually removed from the capillary. Mass spectral data obtained from the enriched and desalted sample confirmed a significant signal enhancement. Finally, a strong acid was introduced to remove the pH junction and thus facilitated a subsequent capillary zone electrophoresis separation. An integrated procedure of enrichment, desalting, and separation was demonstrated on a mixture of three protein standards.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号