首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Zhen Zhou 《Ergonomics》2014,57(5):693-713
The dependence of biodynamic responses of the seated human body on the frequency, magnitude and waveform of vertical vibration has been studied in 20 males and 20 females. With sinusoidal vibration (13 frequencies from 1 to 16 Hz) at five magnitudes (0.1–1.6 ms? 2 r.m.s.) and with random vibration (1–16 Hz) at the same magnitudes, the apparent mass of the body was similar with random and sinusoidal vibration of the same overall magnitude. With increasing magnitude of vibration, the stiffness and damping of a model fitted to the apparent mass reduced and the resonance frequency decreased (from 6.5 to 4.5 Hz). Male and female subjects had similar apparent mass (after adjusting for subject weight) and a similar principal resonance frequency with both random and sinusoidal vibration. The change in biodynamic response with increasing vibration magnitude depends on the frequency of the vibration excitation, but is similar with sinusoidal and random excitation.  相似文献   

2.
This study examined how the apparent mass and transmissibility of the human body depend on the magnitude of fore-and-aft vibration excitation and the presence of vertical vibration. Fore-and-aft and vertical acceleration at five locations along the spine, and pitch acceleration at the pelvis, were measured in 12 seated male subjects during fore-and-aft random vibration excitation (0.25–20 Hz) at three vibration magnitudes (0.25, 0.5 and 1.0 ms−2 r.m.s.). With the greatest magnitude of fore-and-aft excitation, vertical vibration was added at 0.25, 0.5, or 1.0 ms−2 r.m.s. Forces in the fore-and-aft and vertical directions on the seat surface were measured to calculate apparent masses. Transmissibilities and apparent masses during fore-and-aft excitation showed a principal resonance around 1 Hz and a secondary resonance around 2–3 Hz. Increasing the magnitude of fore-and-aft excitation, or adding vertical excitation, decreased the magnitudes of the resonances. At the primary resonance frequency, the dominant mode induced by fore-and-aft excitation involved bending of the lumbar spine and the lower thoracic spine with shear deformation of tissues at the ischial tuberosities. The relative contributions to this mode from each body segment (especially the pelvis and the lower thoracic spine) varied with vibration magnitude. The nonlinearities in the apparent mass and transmissibility during dual-axis excitation indicate coupling between the principal mode of the seated human body excited by fore-and-aft excitation and the cross-axis influence of vertical excitation.Relevance to industryUnderstanding movements of the body during exposure to whole-body vibration can assist the optimisation of seating dynamics and help to control the effects of the vibration on human comfort, performance, and health. This study suggests cross-axis nonlinearity in biodynamic responses to vibration should be considered when optimising vibration environments.  相似文献   

3.
The efficiency of suspension seat can be influenced by several factors such as the input vibration, the dynamic characteristics of the seat and the dynamic characteristics of the human body. The objective of this paper is to study the effect of sitting postures and vibration magnitude on the vibration transmissibility of a suspension system of an agricultural tractor seat. Eleven (11) healthy male subjects participated in the study. All subjects were asked to sit on the suspension system. Four (4) different sitting postures were investigated – i) “relax”, ii) “slouch”, iii) “tense”, and iv) “with backrest support”. All subjects were exposed to random vertical vibration in the range of 1–20 Hz, at three vibration magnitudes - 0.5, 1.0 and 2.0 m/s2 r.m.s for 60 s. The results showed that there were three pronounced peaks in the seat transmissibility, with the primary resonance was found at 1.75–2.5 Hz for every sitting postures. The “backrest” condition had the highest transmissibility resonance (1.46), while the “slouch” posture had the highest Seat Effective Amplitude Transmissibility (SEAT) values (64.7%). Changes in vibration magnitude for “relax” posture from 0.5 to 2.0 m/s2 r.m.s resulted in greater reduction in the primary resonance frequency of seat transmissibility. The SEAT values decreased with increased vibration magnitude. It can be suggested that variations in posture and vibration magnitude affected the vibration transmission through the suspension system, indicating the non-linear effect on the interaction between the human body and the suspension system.Relevance to industry: Investigating the posture adopted during agricultural activities, and the effects of various magnitudes of vibration on the suspension system's performance are beneficial to the industry. The findings regarding their influence on the human body may be used to optimize the suspension system's performance.  相似文献   

4.
Apparent mass (AM) responses of the body seated with and without a back support on three different elastic seats (flat and contoured polyurethane foam (PUF) and air cushion) and a rigid seat were measured under three levels of vertical vibration (overall rms acceleration: 0.25, 0.50 and 0.75 m/s2) in the 0.5 to 20 Hz range. A pressure-sensing system was used to capture biodynamic force at the occupant-seat interface. The results revealed strong effects of visco-elastic and vibration transmissibility characteristics of seats on AM. The response magnitudes with the relatively stiff air seat were generally higher than those with the PUF seats except at low frequencies. The peak magnitude decreased when sitting condition was changed from no back support to a vertical support; the reduction however was more pronounced with the air seat. Further, a relatively higher frequency shift was evident with soft seat compared with stiff elastic seat with increasing excitation.  相似文献   

5.
Zhen Zhou 《Ergonomics》2014,57(5):714-732
Frequency weightings for predicting vibration discomfort assume the same frequency-dependence at all magnitudes of vibration, whereas biodynamic studies show that the frequency-dependence of the human body depends on the magnitude of vibration. This study investigated how the frequency-dependence of vibration discomfort depends on the acceleration and the force at the subject–seat interface. Using magnitude estimation, 20 males and 20 females judged their discomfort caused by sinusoidal vertical acceleration at 13 frequencies (1–16 Hz) at magnitudes from 0.1 to 4.0 ms? 2 r.m.s. The frequency-dependence of their equivalent comfort contours depended on the magnitude of vibration, but was less dependent on the magnitude of dynamic force than the magnitude of acceleration, consistent with the biodynamic non-linearity of the body causing some of the magnitude-dependence of equivalent comfort contours. There were significant associations between the biodynamic responses and subjective responses at all frequencies in the range 1–16 Hz.

Practitioner Summary: Vertical seat vibration causes discomfort in many forms of transport. This study provides the frequency-dependence of vibration discomfort over a range of vibration magnitudes and shows how the frequency weightings in the current standards can be improved.  相似文献   

6.
The biodynamic response of human body seated without a back support and exposed to vertical whole-body vibration have been standardized in ISO 5982 and DIN 45676 in terms of driving-point mechanical impedance and apparent mass. A comparison of ranges defined in two standards, however, reveal considerable differences in both the magnitude and phase. Greater differences are more evident for the three body mass groups, which suggests the lack of adequate reference values of biodynamic responses of seated human subjects of different body masses. In this experimental study, the biodynamic responses of seated humans within three different body mass ranges are characterized under different magnitudes of vibration and three different sitting postures in an attempt to define reference values of apparent mass for applications in mechanical-equivalent model development and anthropodynamic manikin design. Laboratory measurements were performed with adult male subjects of total body mass in the vicinity of 55, 75 and 98 kg (nine subjects for each mass group) seated with and without an inclined back support and exposed to three different magnitudes of white-noise vertical vibration (0.5, 1.0 and 2.0 m/s2 unweighted rms acceleration) in the frequency range between 0.5 and 20 Hz. The measured data were analyzed to derive the mean magnitude and phase responses for the three body masses, posture and excitation conditions. The mean magnitude responses of subjects within three mass groups were compared with idealized ranges defined in ISO 5982 and mean values described in DIN 45676 for no back support condition. The results revealed significant differences between the mean measured and standardized magnitudes, suggesting that the current standardized values do not describe the biodynamic responses of seated occupant of different masses even for the back not supported condition. The mean measured responses revealed most important effect of body mass, irrespective of the sitting posture. The reference values of apparent mass responses of seated body subject to vertical whole-body vibration are thus defined for three mass groups and different back support conditions that may be considered applicable for ranges of excitations considered. The responses of the body seated without a back support, also revealed notable influences of excitation magnitude, particularly on the primary peak frequencies.  相似文献   

7.
Some powered hand tools can generate significant vibration at frequencies below 25 Hz. It is not clear whether such vibration can be effectively transmitted to the upper arm, shoulder, neck, and head and cause adverse effects in these substructures. The objective of this study is to investigate the vibration transmission from the human hands to these substructures. Eight human subjects participated in the experiment, which was conducted on a 1-D vibration test system. Unlike many vibration transmission studies, both the right and left hand-arm systems were simultaneously exposed to the vibration to simulate a working posture in the experiment. A laser vibrometer and three accelerometers were used to measure the vibration transmitted to the substructures. The apparent mass at the palm of each hand was also measured to help in understanding the transmitted vibration and biodynamic response. This study found that the upper arm resonance frequency was 7–12 Hz, the shoulder resonance was 7–9 Hz, and the back and neck resonances were 6–7 Hz. The responses were affected by the hand-arm posture, applied hand force, and vibration magnitude. The transmissibility measured on the upper arm had a trend similar to that of the apparent mass measured at the palm in their major resonant frequency ranges. The implications of the results are discussed.Relevance to industryMusculoskeletal disorders (MSDs) of the shoulder and neck are important issues among many workers. Many of these workers use heavy-duty powered hand tools. The combined mechanical loads and vibration exposures are among the major factors contributing to the development of MSDs. The vibration characteristics of the body segments examined in this study can be used to help understand MSDs and to help develop more effective intervention methods.  相似文献   

8.
Biodynamic models representing distributed human-seat interactions can assist seat design. This study sought to develop a finite element (FE) model representing the soft tissues of the body supported by seating and the vertical in-line apparent mass and the fore-and-aft cross-axis apparent mass of the seated human body during vertical vibration excitation. The model was developed with rigid parts representing the torso segments, skeletal structures (pelvis and femurs) and deformable parts representing the soft tissues of the buttocks and the thighs. The model had three vibration modes at frequencies less than 15 Hz and provided reasonable vertical in-line apparent mass and fore-and-aft cross-axis apparent mass. The model can be developed to represent dynamic interactions between the body and a seat over a seat surface (e.g. dynamic pressure distributions and variations in seat transmissibility over the seat surface).  相似文献   

9.
This study explored the feasibility of the flexible resistive (FlexiForce) force sensors for measurement of the hand-arm biodynamic response. Two FlexiForce sensors were installed on an instrumented handle to measure the palm-handle and finger–handle interface dynamic forces. The measurements were performed with six subjects grasping a 38 mm diameter instrumented handle with nine different combinations of grip (10, 30 and 50 N) and push (25, 50 and 75 N) forces and two levels of broad-band random vibration (1.5 and 3.0 m/s2 weighted rms acceleration) in the 4–1000 Hz frequency range. The data acquired from the instrumented handle was analyzed to determine the palm and finger impedance responses, which served as the reference values to evaluate feasibility of the FlexiForce sensors. The comparisons revealed very similar trends, while the impedance magnitude responses obtained from the FlexiForce sensors were substantially lower in the entire frequency range than the reference values, except at very low frequencies. A correction function was subsequently developed and applied to the FlexiForce measured data, which resulted in similar hand-arm impedance response trends compared to the reference values. It was concluded that the low-cost FlexiForce sensors could be applied for measurements of biodynamic responses of the hand-arm system in real tool handles in the field. Due to the physiological risks associated with prolonged exposure to tool vibration the applicability of a low-cost biodynamic response measurement system can be used as a preventative measure for such risks.Relevance to industryThe measurement of hand–handle interface forces is vital for assessing the hand-transmitted vibration exposure and the biodynamic responses of the hand-arm system to vibration. The low cost and flexible sensors, proposed in the study, could be conveniently applied to the curved surfaces of real power tool handles in the field. The most significant benefit of the sensors lies with its negligible mass and thereby the instrumented handle inertia-induced errors in the biodynamic responses can be eliminated.  相似文献   

10.
The gender and anthropometric effects on apparent mass characteristics of the seated body exposed to vertical vibration are investigated through laboratory measurements. The study was conducted on 31 male and 27 female subjects, exposed to three levels of vertical vibration (0.25, 0.50 and 0.75 m/s2 rms acceleration) in the 0.50 to 20 frequency range, while seated without a back support and against a vertical back support. The apparent mass responses were analyzed by grouping datasets in three ranges of mass-, build- and stature-related parameters for the male and female subjects. Comparisons of responses of male and female subjects with comparable anthropometric properties showed distinctly different biodynamic responses of the two genders. The primary resonance frequency of male subjects was significantly (p < 0.001) higher than the female subjects of comparable body mass but the peak magnitude was comparable for both the gender groups. The male subjects showed greater softening with increasing excitation magnitude compared to the female subjects, irrespective of the sitting condition. The male subjects showed significantly higher peak magnitude response than those of the female subjects for the same anthropometric properties, except for the total and lean body mass. The peak magnitude was linearly correlated with the body mass, body mass index, body fat and hip circumference (r2 > 0.7), irrespective of the back support and excitation conditions for both the genders.Relevance to the industryThe apparent mass responses of the human body exposed to whole-body vibration form an essential basis for an understanding of mechanical-equivalent properties of the body, developments in frequency-weightings for assessment of exposure risks and anthropodynamic manikins for assessment of seats. The effects of gender and anthropometric parameters on the AM response are vital for seeking better seat designs, and anthropodynamic manikins for assessments of seating for male as well as female workers.  相似文献   

11.
Prolonged, intensive exposure to vibrations from palm and orbital sanders could cause finger disorders. They are likely to be associated with the biodynamic responses of the fingers. Although the biodynamic responses of the hand-arm system have been studied by many researchers, the detailed biodynamic responses distributed in the hand substructures have not been sufficiently understood. To advance the knowledge in this aspect and to aid in the development of improved finite element models of the substructures, this study simultaneously measured the overall driving-point biodynamic response and the distribution of vibration transmissibility at the fingers and back of the hand exposed to a flat plate vibration (as an approximate simulation of the operations of the palm and orbital sanders) and examined the relationship between these two measures of biodynamic responses. Ten subjects (five males and five females) participated in the experiment. A scanning laser vibrometer was used to measure the distributed vibration. This study confirmed that the distributed hand responses generally varied with locations on each finger, vibration frequencies, and applied hand force. Two major resonances were observed in the vibration transmissibility. At the first resonance, the transmitted vibrations at different locations were more or less in phase; hence, this resonance was also observed in the driving-point biodynamic response that measures the overall biodynamic response of the system. The second resonance was observed at the fingers. Because this resonant frequency varied greatly among the fingers and the specific segments of each finger, it is difficult to identify this resonance in the driving-point biodynamic response. The implications of the findings for further model developments and applications are discussed.

Relevance to industry

This study enhanced the understanding of the biodynamic responses of the fingers and hand exposed to vibrations on a contact surface with a large effective radius such as that found on palm and orbital sanders. The results can also be used to develop and/or validate models of the substructures of the hand-arm system, which can be further used to help design and analyze these tools and associated anti-vibration devices. The results may also be applicable to help develop location-specific frequency weightings to assess the risks of the finger vibration exposure.  相似文献   

12.
The aptness of two anthropodynamic manikins for assessing vibration isolation effectiveness of suspension seats is evaluated through laboratory measurements. The evaluations were performed using five different suspension seats exposed to idealized white noise (0.5–20 Hz) and target vehicle excitations along the vertical axis using a whole-body vehicular vibration simulator. The measurements were performed to derive acceleration transmissibility and seat effective amplitude transmissibility (SEAT) characteristics of seats loaded with: human subjects of body masses in the vicinity of 55, 75 and 98 kg; manikins configured to same masses; and equivalent rigid masses. The dynamic responses of the manikins were also measured under different magnitudes of white-noise excitations and expressed in terms of apparent mass. The relative applicability of the manikins for selected seats was evaluated by comparing the measures with those obtained for the seat–human and seat–mass systems. The comparisons suggested that the SEAT measures attained with manikins are comparable with those obtained with equivalent rigid mass, irrespective of the body mass, for the low natural frequency seats (2 Hz) considered in the study. Both the manikins and the equivalent rigid masses, however, provided an overestimate of isolation effectiveness of seats, when compared to those with human subjects. The manikins resulted in better estimates of SEAT values for high natural frequency seats than the rigid mass. The dynamic responses of manikins were also compared with the ranges of standardized values reported in ISO-5982 and DIN-45676. The results revealed considerable differences between the biodynamic responses of manikins and the standardized ranges.  相似文献   

13.
The extent to which a seat can provide useful attenuation of vehicle vibration depends on three factors: the characteristics of the vehicle motion, the vibration transmissibility of the seat, and the sensitivity of the body to vibration. The ‘seat effective amplitude transmissibility’ (i.e., SEAT value) reflects how these three factors vary with the frequency and the direction of vibration so as to predict the vibration isolation efficiency of a seat. The SEAT value is mostly used to select seat cushions or seat suspensions based on the transmission of vertical vibration to the principal supporting surface of a seat. This study investigated the accuracy of SEAT values in predicting how seats with backrests influence the discomfort caused by multiple-input vibration. Twelve male subjects participated in a four-part experiment to determine equivalent comfort contours, the relative discomfort, the location of discomfort, and seat transmissibility with three foam seats and a rigid reference seat at 14 frequencies of vibration in the range 1–20 Hz at magnitudes of vibration from 0.2 to 1.6 ms−2 r.m.s. The ‘measured seat dynamic discomfort’ (MSDD) was calculated for each foam seat from the ratio of the vibration acceleration required to cause similar discomfort with the foam seat and with the rigid reference seat. Using the frequency weightings in current standards, the SEAT values of each seat were calculated from the ratio of overall ride values with the foam seat to the overall ride values with the rigid reference seat, and compared to the corresponding MSDD at each frequency. The SEAT values provided good predictions of how the foam seats increased vibration discomfort at frequencies around the 4-Hz resonance but reduced vibration discomfort at frequencies greater than about 6.3 Hz, with discrepancies explained by a known limitation of the frequency weightings.  相似文献   

14.
Yu Huang  Penglin Zhang 《Ergonomics》2019,62(3):420-430
Current standards assume the same frequency weightings for discomfort at all magnitudes of vibration, whereas biodynamic and psychological studies show that the frequency-dependence of objective and subjective responses of the human body depends on the magnitude of vibration. This study investigated the discomfort of seated human body caused by vertical whole-body vibration over the frequency range 2–100?Hz at relatively high magnitudes from 1.0 to 2.5?ms?2 r.m.s. Twenty-eight subjects (15 males and 13 females) judged the discomfort using the absolute magnitude estimation method. The rate of growth of discomfort with increasing vibration magnitude was highly dependent on the frequency, so the shapes of the equivalent comfort contours depended on the magnitude of vibration and no single frequency weighting would be appropriate for all magnitudes. The equivalent comfort contours indicated that the standards and previous relevant studies underestimated the vibration discomfort at frequencies greater than about 30?Hz.

Practitioner Summary: The discomfort caused by vertical vibration at relatively high frequencies can be severe, particularly at relatively great magnitudes in transport. This study provides the frequency-dependence of vibration discomfort at 2–100?Hz, and shows how the frequency weightings in the current standards can be improved at relatively high frequencies.  相似文献   


15.
《Ergonomics》2012,55(12):1806-1822
The apparent mass (AM) responses of human body seated on elastic seat, without and with a vertical back support, are measured using a seat pressure sensing mat under three levels of vertical vibration (0.25, 0.50 and 0.75 m/s2 rms acceleration) in 0.50–20 Hz frequency range. The responses were also measured with a rigid seat using the pressure mat and a force plate in order to examine the validity of the pressure mat. The pressure mat resulted in considerably lower AM magnitudes compared to the force plate. A correction function was proposed and applied, which resulted in comparable AM from both measurement systems for the rigid seat. The correction function was subsequently applied to derive AM of subjects seated on elastic seat. The responses revealed lower peak magnitude and corresponding frequency compared to those measured with rigid seat, irrespective of back support and excitation considered.  相似文献   

16.
Need and importance of modelling in human body vibration research studies are well established. The study of biodynamic responses of human beings can be classified into experimental and analytical methods. In the past few decades, plenty of mathematical models have been developed based on the diverse field measurements to describe the biodynamic responses of human beings. In this paper, a complete study on lumped parameter model derived from 50th percentile anthropometric data for a seated 54- kg Indian male subject without backrest support under free un-damped conditions has been carried out considering human body segments to be of ellipsoidal shape. Conventional lumped parameter modelling considers the human body as several rigid masses interconnected by springs and dampers. In this study, concept of mass of interconnecting springs has been incorporated and eigenvalues thus obtained are found to be closer to the values reported in the literature. Results obtained clearly establish decoupling of vertical and fore-and-aft oscillations.  相似文献   

17.
《Ergonomics》2012,55(5):833-855
Operation of vibrating power hand tools can result in excessive grip force, which may increase the risk of cumulative trauma disorders in the upper extremities. An experiment was performed to study grip force exerted by 14 subjects operating a simulated hand tool vibrating at 9.8 m/s2 and 49 m/s2 acceleration magnitudes, at 40 Hz and 160 Hz frequencies, with vibration delivered in three orthogonal directions, and with 1.5kg and 3.0kg load weights. Average grip force increased from 25.3 N without vibration to 32.1 N (27%) for vibration at 40 Hz, and to 27.1N (7%) for vibration at 160 Hz. Average grip force also increased from 27.4 N at 9.8 m/s2 acceleration to 31.8 N (16%) at 49m/s2. Significant interactions between acceleration x frequency, and frequency x direction were also found. The largest average grip force increase was from 25.3N without vibration to 35.8N (42%) for 40 Hz and 49 m/s2 vibration. The magnitude of this increase was of the same order as for a two-fold increase in load weight, where average grip force increased from 22.5N to 35.0N (56%). A second experiment studied hand flexor and extensor muscle responses using electromyography for five subjects holding a handle vibrating at 8 m/s2 using ISO weighted acceleration, with frequencies of 20 Hz, 40 Hz, 80 Hz and 160 Hz, and grip forces of 5%, 10% and 15% of maximum voluntary contraction. Muscle responses were greatest at frequencies where grip force was affected, indicating that the tonic vibration reflex was the likely cause of increased grip exertions.  相似文献   

18.
《Ergonomics》2012,55(5):488-496
The extent to which a glove modifies the risks from hand-transmitted vibration is quantified in ISO 10819:1996 by a measure of glove transmissibility determined with one vibration magnitude, one contact force with a handle and only three subjects. This study was designed to investigate systematically the vibration transmissibility of four ‘anti-vibration’ gloves over the frequency range 16–1600 Hz with 12 subjects, at six magnitudes of vibration (0.25–8.0 ms?2 r.m.s.) and with six push forces (5 N to 80 N). The four gloves showed different transmissibility characteristics that were not greatly affected by vibration magnitude but highly dependent on push force. In all conditions, the variability in transmissibility between subjects was as great as the variability between gloves. It is concluded that a standardised test of glove dynamic performance should include a wide range of hands and a range of forces representative of those occurring in work with vibratory tools.

Statement of Relevance: The transmission of vibration through anti-vibration gloves is highly dependent on the push force between the hand and a handle and also highly dependent on the hand that is inside the glove. The influence of neither factor is well reflected in ISO 10819:1996, the current standard for anti-vibration gloves.  相似文献   

19.
Helicopter seats are designed to a specified mass range including equipment and can only provide limited energy absorbing protection within its designed energy absorbing capability. Over recent years, military occupants have been required to carry increasing amounts of equipment, which may affect the probability of injury during a crash. To investigate the effects of increasing equipment mass during a helicopter crash on injury, a linear 7-degree-of-freedom mass–spring–damper model is developed to simulate an occupant wearing body-borne equipment on a crashworthy helicopter seat. A fixed load energy absorption mechanism is also included in the model. To examine the effects of equipment attachment types, the mass bodies representing the equipment are attached with a spring and damper, with low and high stiffness values indicating loose and tight attachment respectively. Dimensional analysis shows that the maximum forces are proportional to the initial impact velocity prior to stroke. The results demonstrate that increasing the equipment mass reduces the seat's capability to absorb the total impact energy at higher initial impact velocities. The safe velocity, the velocity that prevents bottoming out, reduces from 10.2 m/s, for an occupant without equipment, to 7.4 m/s for an occupant with an equipment mass of 40 kg at the lower and upper torso and 2 kg at the head. When the equipment mass is 40 kg at the hip and at the upper torso and 2 kg at the head, a maximum increase on the underside of the pelvis of 173% is measured, providing an increased possibility of injury in the lumbar region. Increases of 321%, 889% and 335% on the maximum forces on the hip, upper torso and head respectively create the potential for contact injury at the hip, upper torso and head from equipment and more than a 50% chance of spinal injury. The results show that increasing equipment mass significantly increases the potential for injury at the lumbar, hip, upper torso and head.  相似文献   

20.
This study conducted two series of experiments to investigate the relationships between hand coupling force and biodynamic responses of the hand–arm system. In the first experiment, the vibration transmissibility on the system was measured as a continuous function of grip force while the hand was subjected to discrete sinusoidal excitations. In the second experiment, the biodynamic responses of the system subjected to a broadband random vibration were measured under five levels of grip forces and a combination of grip and push forces. This study found that the transmissibility at each given frequency increased with the increase in the grip force before reaching a maximum level. The transmissibility then tended to plateau or decrease when the grip force was further increased. This threshold force increased with an increase in the vibration frequency. These relationships remained the same for both types of vibrations. The implications of the experimental results are discussed.

Practitioner Summary: Shocks and vibrations transmitted to the hand–arm system may cause injuries and disorders of the system. How to take hand coupling force into account in the risk assessment of vibration exposure remains an important issue for further studies. This study is designed and conducted to help resolve this issue.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号