首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Visualization of proteins inside acrylamide and other gels usually relies on different staining methods. To omit the protein-staining procedure, we visualized unstained proteins inside acrylamide gels by laser excitation with ultraviolet (UV) light (280 nm, 35 mJ/cm2) and directly detected native UV fluorescence. In one-dimensional gels, a detection limit as low as 1 ng for bovine serum albumin and 5 ng for other proteins with a linear dynamic range (2.7 orders of magnitude) comparable to state of the art fluorescent dyes could be achieved. In addition, the application of this method to 20 microg of a whole cell lysate separated in a two-dimensional gel showed more than 600 spots. Since protein labeling always represents a serious obstacle in protein identification technologies, the working efficiency with our procedure can be considered as a significant improvement for protein visualization and reproducibility in proteomics.  相似文献   

2.
We propose a novel method for the identification and C-terminal characterization of proteins separated by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE). Proteins were digested in a gel in a buffer solution containing 50% 18O-labeled water, and mixtures of 18O/16O-labeled peptides were analyzed by nanoelectrospray Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). This method was evaluated using horse skeletal muscle myoglobin as the model protein in SDS gel. The high resolution of FT-ICR MS minimized the overlapping of peptide peaks and facilitated identification of the C-terminal peptide, which was done by observing the undisrupted isotope peak pattern. As well, with its low ppm-level high mass accuracy, it can rapidly and reliably identify the in-gel-separated protein and determine its C-terminal by peptide mass fingerprinting alone. Therefore, this method should be applicable to routine and high-throughput proteome studies. Here, the method was applied to the analysis of rat liver proteins separated by 2D-PAGE. The C-termini of eight proteins were successfully identified out of 10 randomly picked Coomassie brilliant blue-stained spots. The feasibility and limitations of this approach are reported in this paper.  相似文献   

3.
The goal of this study was the development of N-terminal tags to improve peptide identification using high-throughput MALDI-TOF/TOF MS. Part 1 of the study was focused on the influence of derivatization on the intensities of MALDI-TOF MS signals of peptides. In part 2, various derivatization approaches for the improvement of peptide fragmentation efficiency in MALDI-TOF/TOF MS are explored. We demonstrate that permanent cation tags, while significantly improving signal intensity in the MS mode, lead to severe suppression of MS/MS fragmentation, making these tags unsuitable for high-throughput MALDI-TOF/TOF MS analysis. In the present work, it was found that labeling with Alexa Fluor 350, a coumarin tag containing a sulfo group, along with guanidation of epsilon-amino groups of Lys, could enhance unimolecular fragmentation of peptides with the formation of a high-intensity y-ion series, while the peptide intensities in the MS mode were not severely affected. LC-MALDI-TOF/TOF MS analysis of tryptic peptides from the SCX fractions of an E. coli lysate revealed improved peptide scores, a doubling of the total number of peptides, and a 30% increase in the number of proteins identified, as a result of labeling. Furthermore, by combining the data from native and labeled samples, confidence in correct identification was increased, as many proteins were identified by different peptides in the native and labeled data sets. Additionally, derivatization was found not to impair chromatographic behavior of peptides. All these factors suggest that labeling with Alexa Fluor 350 is a promising approach to the high-throughput LC-MALDI-TOF/TOF MS analysis of proteomic samples.  相似文献   

4.
Human brain proteins containing phosphorus, copper, and zinc were detected directly in protein spots in gels of a human brain sample after separation by two-dimensional gel electrophoresis using laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS). A powerful laser ablation system with cooled laser ablation chamber was coupled to a double-focusing sector field ICPMS. The separated protein spots in 2D gels were fast screened using the optimized microanalytical LA-ICPMS technique measured at medium mass resolution with a focused laser beam (wavelength, 213 nm; diameter of laser crater, 50 mum; and laser power density, 3 x 10(9) W cm(-2)) with respect to selected three essential elements. Of 176 protein spots in 2D gel from a human brain sample, phosphorus, copper, and zinc were detected in 31, 43, and 49 protein spots, respectively. For the first time, uranium as a naturally occurring radioactive element was found in 20 selected protein spots. The detection limits for P, S, Cu, Zn and U were determined in singular protein spots with 0.0013, 1.29, 0.029, 0.063, and 0.000 01 mg g(-1), respectively. A combination of LA-ICPMS with matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR-MS) was applied for the identification of selected protein spots from human brain protein separated by 2D gel electrophoresis. Combining MALDI-FTICR-MS for the structure analysis of metal- and phosphorus-containing human brain proteins with LA-ICPMS, the direct analysis of heteroelements on separated proteins in 2D gels can be performed. For quantification of analytical LA-ICPMS data, the number of sulfur atoms per protein (and following the sulfur concentration) determined by MALDI-FTICR-MS was used for internal standardization. From the known sulfur concentration in protein, the concentration of other heteroelements was calculated. In addition, the number of phosphorylation and the phosphorylation sites of phosphorylated proteins in the human brain sample detected by LA-ICPMS were determined by MALDI-FTICR-MS. This technique allows the study of posttranslational modifications in human brain proteins.  相似文献   

5.
Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increase sample throughput, we have developed a novel in-gel digestion protocol where sample preparation is performed directly on a MALDI probe with prestructured sample support. The protocol consists of few sample-handling steps and has minimal consumption of reagents, making the protocol sensitive, timesaving, and cost-efficient. Performance of the on-probe sample preparation protocol was demonstrated by analysis of a set of rat liver proteins obtained from a fluorescently stained (Cy3 and SyproRuby) two-dimensional polyacrylamide gel. The success rate of protein identification by on-probe tryptic digestion and MALDI peptide mass mapping was 89%. The on-probe in-gel digestion procedure provided superior sensitivity and peptide mass mapping performance as compared to our standard in-gel digestion protocol. The on-probe digestion technique resulted in significantly improved amino acid sequence coverage of proteins, mainly due to efficient recovery and detection of large (>1.5 kDa) hydrophobic peptides. These observations indicate that numerous tryptic peptides are lost when using the standard in-gel digestion methods and sample preparation techniques for MALDI MS. This study also demonstrates that the on-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications.  相似文献   

6.
For analysis of intact proteins by mass spectrometry (MS), a new twist to a two-dimensional approach to proteome fractionation employs an acid-labile detergent instead of sodium dodecyl sulfate during continuous-elution gel electrophoresis. Use of this acid-labile surfactant (ALS) facilitates subsequent reversed-phase liquid chromatography (RPLC) for a net two-dimensional fractionation illustrated by transforming thousands of intact proteins from Saccharomyces cerevisiae to mixtures of 5-20 components (all within approximately 5 kDa of one another) for presentation via electrospray ionization (ESI) to a Fourier transform MS (FTMS). Between 3 and 13 proteins have been detected directly using ESI-FTMS (or MALDI-TOF), and the fractionation showed a peak capacity of approximately 400 between 0 and 70 kDa. A probability-based identification was made automatically from raw MS/MS data (obtained using a quadrupole-FTMS hybrid instrument) for one protein that differed from that predicted in a yeast database of approximately 19,000 protein forms. This ALS-PAGE/RPLC approach to proteome processing ameliorates the "front end" problem that accompanies direct analysis of whole proteins and assists the future realization of protein identification with 100% sequence coverage in a high-throughput format.  相似文献   

7.
Systematic identification of mitochondrial proteins by LC-MS/MS   总被引:6,自引:0,他引:6  
In eukaryotic cells, the mitochondrion is the key organelle for cellular respiration. Mitochondrial proteome analysis is difficult to perform by the classical proteomic approach involving two-dimensional gel electrophoresis (2DE), because this organelle contains a large number of membrane-associated and highly alkaline proteins usually requiring specific treatments to be successfully analyzed. Here, an alternative approach was evaluated and led to the rapid and sensitive identification of approximately 35% of the yeast mitochondrial proteins. It consists of an SDS-PAGE gel electrophoresis of the total mitochondrial protein in combination with the LC-MS/MS analysis of the digestion products of gel slices. The use of only 40 microg of mitochondrial protein enabled the identification of 179 different gene products divided into similar proportions of membrane and soluble proteins. The distribution of the identified proteins in terms of pI and hydrophobicity revealed that the present analytical strategy is largely unbiased. The identification of 28 proteins of previously unknown subcellular localization demonstrated the ability of SDS-PAGE-LC-MS/MS to rapidly supplement the knowledge of the mitochondrial proteome.  相似文献   

8.
The large-scale identification and quantitation of proteins via nanoliquid chromatography (LC)-tandem mass spectrometry (MS/MS) offers a unique opportunity to gain unprecedented insight into the microbial composition and biomolecular activity of true environmental samples. However, in order to realize this potential for marine biofilms, new methods of protein extraction must be developed as many compounds naturally present in biofilms are known to interfere with common proteomic manipulations and LC-MS/MS techniques. In this study, we used amino acid analyses (AAA) and LC-MS/MS to compare the efficacy of three sample preparation methods [6 M guanidine hydrochloride (GuHCl) protein extraction + in-solution digestion + 2D LC; sodium dodecyl sulfate (SDS) protein extraction + 1D gel LC; phenol protein extraction + 1D gel LC] for the metaproteomic analyses of an environmental marine biofilm. The AAA demonstrated that proteins constitute 1.24% of the biofilm wet weight and that the compared methods varied in their protein extraction efficiencies (0.85-15.15%). Subsequent LC-MS/MS analyses revealed that the GuHCl method resulted in the greatest number of proteins identified by one or more peptides whereas the phenol method provided the greatest sequence coverage of identified proteins. As expected, metagenomic sequencing of the same biofilm sample enabled the creation of a searchable database that increased the number of protein identifications by 48.7% (≥1 peptide) or 54.7% (≥2 peptides) when compared to SwissProt database identifications. Taken together, our results provide methods and evidence-based recommendations to consider for qualitative or quantitative biofilm metaproteome experimental design.  相似文献   

9.
A novel extension of the "top-down" approach is introduced for the selective characterization of protein termini that does not involve proteolytic digestion steps. N- and C-terminal peptides were generated from intact proteins in the mass spectrometer and further analyzed by MS/MS-an approach referred to as T(3)-sequencing. N-terminal and C-terminal fragment ion series were obtained by the pseudo-MS/MS technique in-source decay (ISD) on a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI-TOF MS). These ions provided near-terminal sequence tags from the undigested protein in the ISD spectrum acquired in reflector mode and allowed to screen for the proper processing state of the terminus with respect to a reference sequence. In the second step of T(3)-sequencing, the precursor ions, which have been generated by ISD and which included the N- or C-terminal sequence, were selected in the timed ion gate of a MALDI-TOF/TOF mass spectrometer for MS/MS analysis. These spectra allowed identification of the protein, the proper definition of both termini, and allowed confirmation of suspected terminal modifications. T(3)-Sequencing appears to be an alternative to classical Edman sequencing, which is fast and even permits the analysis of N-terminally blocked proteins and their C-terminus.  相似文献   

10.
The direct combination of gel electrophoresis and infrared laser desorption/ionization time-of-flight mass spectrometry has been demonstrated. We present results for infrared laser desorption and ionization mass spectrometry of peptides and proteins directly from a polyacrylamide gel without the addition of a matrix. Analyte molecules up to 6 kDa were ionized directly from a vacuum-dried sodium dodecyl sulfate-polyacrylamide gel after electrophoretic separation. Mass spectra were obtained at the wavelength of 2.94 microm, which is consistent with IR absorption by N-H and O-H stretch vibrations of water and other constituents of the gel. A 5-nmol quantity of peptide or protein was loaded per gel slot, although it was possible to obtain mass spectra from a small fraction of the gel spot. This technique shows promise for the direct identification of both parent and fragment masses of proteins contained in polyacrylamide gels.  相似文献   

11.
Identification and characterization of all proteins expressed by a genome in biological samples represent major challenges in proteomics. Today's commonly used high-throughput approaches combine two-dimensional electrophoresis (2-DE) with peptide mass fingerprinting (PMF) analysis. Although automation is often possible, a number of limitations still adversely affect the rate of protein identification and annotation in 2-DE databases: the sequential excision process of pieces of gel containing protein; the enzymatic digestion step; the interpretation of mass spectra (reliability of identifications); and the manual updating of 2-DE databases. We present a highly automated method that generates a fully annoated 2-DE map. Using a parallel process, all proteins of a 2-DE are first simultaneously digested proteolytically and electro-transferred onto a poly(vinylidene difluoride) membrane. The membrane is then directly scanned by MALDI-TOF MS. After automated protein identification from the obtained peptide mass fingerprints using PeptIdent software (http://www.expasy.ch/tools/peptident.html + ++), a fully annotated 2-D map is created on-line. It is a multidimensional representation of a proteome that contains interpreted PMF data in addition to protein identification results. This "MS-imaging" method represents a major step toward the development of a clinical molecular scanner.  相似文献   

12.
Online liquid chromatography-mass spectrometric (LC-MS) analysis of intact proteins (i.e., top-down proteomics) is a growing area of research in the mass spectrometry community. A major advantage of top-down MS characterization of proteins is that the information of the intact protein is retained over the vastly more common bottom-up approach that uses protease-generated peptides to search genomic databases for protein identification. Concurrent to the emergence of top-down MS characterization of proteins has been the development and implementation of the stable isotope labeling of amino acids in cell culture (SILAC) method for relative quantification of proteins by LC-MS. Herein we describe the qualitative and quantitative top-down characterization of proteins derived from SILAC-labeled Aspergillus flavus using nanoflow reversed-phase liquid chromatography directly coupled to a linear ion trap Fourier transform ion cyclotron resonance mass spectrometer (nLC-LTQ-FTICR-MS). A. flavus is a toxic filamentous fungus that significantly impacts the agricultural economy and human health. SILAC labeling improved the confidence of protein identification, and we observed 1318 unique protein masses corresponding to 659 SILAC pairs, of which 22 were confidently identified. However, we have observed some limiting issues with regard to protein quantification using top-down MS/MS analyses of SILAC-labeled proteins. The role of SILAC labeling in the presence of competing endogenously produced amino acid residues and its impact on quantification of intact species are discussed in detail.  相似文献   

13.
We describe a method for comparative quantitation and de novo peptide sequencing of proteins separated either by standard chromatographic methods or by one- and two-dimensional polyacrylamide gel electrophoresis. The approach is based on the use of an isotopically labeled reagent to quantitate (by mass spectrometry) the ratio of peptides from digests of a protein being expressed under different conditions. The method allows quantitation of the changes occurring in spots or bands that contain more than one protein and has a greater dynamic range than most staining methods. Since the reagent carries a fixed positive charge under acidic conditions and labels only the N-terminal of peptides, the interpretation of tandem mass spectra to obtain sequence information is greatly simplified. The sequences can easily be extracted for homology searches instead of using indirect mass spectral-based searches and are independent of posttranslational modifications.  相似文献   

14.
Significant identification of proteins by mass fingerprinting and partial sequencing of tryptic peptides is central to proteomics. However, peptide masses cluster with distances of approximately 1 Da. Expanding these clusters will give more peptides of unique masses, thereby identifying proteins with a higher significance. The mass clusters can be expanded downward by including more oxygen atoms in the peptides. Classic performic acid oxidation modifies three residues, Cys to CysO(3), Met to MetO(2), and Trp to TrpO(2). In this study, we compare the mass distributions of tryptic peptides computed from the predicted proteomes of Bacillus subtilis, Drosophila melanogaster, Arabidopsis thaliana, and Homo sapiens modified by oxidation, reduction, and reduction followed by carboxymethylation, carboxamidomethylation, or pyridylethylation. Forty to 46% of the eukaryotic tryptic peptides contain Cys, Met, or Trp. Additionally, the importance of mass accuracy of differentially modified tryptic peptides for significant protein identification by database searches was analyzed. The results show that performic acid oxidation gives markedly extended mass distributions at mass accuracies from +/-0.002 to +/-0.25 Da for the eukaryotes. The effect of the expanded mass distribution on significant protein identification was illustrated by searching simulated mass peak lists against the databases containing oxidized and reduced tryptic peptides. The specificity of formic acid oxidation was tested experimentally, and no general adverse effects were detected. Tryptic peptides provided a 100% sequence coverage of oxidized barley grain peroxidase by LC-MS, and the sequence coverages of oxidized and carboxymethylated bovine serum albumin were similar by MALDI-TOF MS analyses.  相似文献   

15.
For automated production of tandem mass spectrometric data for proteins and peptides >3 kDa at >50 000 resolution, a dual online-offline approach is presented here that improves upon standard liquid chromatography-tandem mass spectrometry (LC-MS/MS) strategies. An integrated hardware and software infrastructure analyzes online LC-MS data and intelligently determines which targets to interrogate offline using a posteriori knowledge such as prior observation, identification, and degree of characterization. This platform represents a way to implement accurate mass inclusion and exclusion lists in the context of a proteome project, automating collection of high-resolution MS/MS data that cannot currently be acquired on a chromatographic time scale at equivalent spectral quality. For intact proteins from an acid extract of human nuclei fractionated by reversed-phase liquid chromatography (RPLC), the automated offline system generated 57 successful identifications of protein forms arising from 30 distinct genes, a substantial improvement over online LC-MS/MS using the same 12 T LTQ FT Ultra instrument. Analysis of human nuclei subjected to a shotgun Lys-C digest using the same RPLC/automated offline sampling identified 147 unique peptides containing 29 co- and post-translational modifications. Expectation values ranged from 10 (-5) to 10 (-99), allowing routine multiplexed identifications.  相似文献   

16.
Proteomics has grown significantly with the aid of new technologies that consistently are becoming more streamlined. While processing of proteins from a whole cell lysate is typically done in a bottom-up fashion utilizing MS/MS of peptides from enzymatically digested proteins, top-down proteomics is becoming a viable alternative that until recently has been limited largely to offline analysis by tandem mass spectrometry. Here we describe a method for high-resolution tandem mass spectrometery of intact proteins on a chromatographic time scale. In a single liquid chromatography-tandem mass spectrometry (LC-MS/MS) run, we have identified 22 yeast proteins with molecular weights from 14 to 35 kDa. Using anion exchange chromatography to fractionate a whole cell lysate before online LC-MS/MS, we have detected 231 metabolically labeled (14N/15N) protein pairs from Saccharomyces cerevisiae. Thirty-nine additional proteins were identified and characterized from LC-MS/MS of selected anion exchange fractions. Automated localization of multiple acetylations on Histone H4 was also accomplished on an LC time scale from a complex protein mixture. To our knowledge, this is the first demonstration of top-down proteomics (i.e., many identifications) on linear ion trap Fourier transform (LTQ FT) systems using high-resolution MS/MS data obtained on a chromatographic time scale.  相似文献   

17.
We describe the first implementation of negative electron-transfer dissociation (NETD) on a hybrid ion trap-orbitrap mass spectrometer and its application to high-throughput sequencing of peptide anions. NETD, coupled with high pH separations, negative electrospray ionization (ESI), and an NETD compatible version of OMSSA, is part of a complete workflow that includes the formation, interrogation, and sequencing of peptide anions. Together these interlocking pieces facilitated the identification of more than 2000 unique peptides from Saccharomyces cerevisiae representing the most comprehensive analysis of peptide anions by tandem mass spectrometry to date. The same S. cerevisiae samples were interrogated using traditional, positive modes of peptide LC-MS/MS analysis (e.g., acidic LC separations, positive ESI, and collision activated dissociation), and the resulting peptide identifications of the different workflows were compared. Due to a decreased flux of peptide anions and a tendency to produce lowly charged precursors, the NETD-based LC-MS/MS workflow was not as sensitive as the positive mode methods. However, the use of NETD readily permits access to underrepresented acidic portions of the proteome by identifying peptides that tend to have lower pI values. As such, NETD improves sequence coverage, filling out the acidic portions of proteins that are often overlooked by the other methods.  相似文献   

18.
We demonstrate the use of capillary zone electrophoresis with an electrokinetically pumped sheath-flow electrospray interface for the analysis of a tryptic digest of a sample of intermediate protein complexity, the secreted protein fraction of Mycobacterium marinum. For electrophoretic analysis, 11 fractions were generated from the sample using reverse-phase liquid chromatography; each fraction was analyzed by CZE-ESI-MS/MS, and 334 peptides corresponding to 140 proteins were identified in 165 min of mass spectrometer time at 95% confidence (FDR < 0.15%). In comparison, 388 peptides corresponding to 134 proteins were identified in 180 min of mass spectrometer time by triplicate UPLC-ESI-MS/MS analyses, each using 250 ng of the unfractionated peptide mixture, at 95% confidence (FDR < 0.15%). Overall, 62% of peptides identified in CZE-ESI-MS/MS and 67% in UPLC-ESI-MS/MS were unique. CZE-ESI-MS/MS favored basic and hydrophilic peptides with low molecular masses. Combining the two data sets increased the number of unique peptides by 53%. Our approach identified more than twice as many proteins as the previous record for capillary electrophoresis proteome analysis. CE-ESI-MS/MS is a useful tool for the analysis of proteome samples of intermediate complexity.  相似文献   

19.
Biomarkers in the cerebrospinal fluid (CSF) may be important for the diagnosis of chronic degenerative disorders in the central nervous system including dementia. Existing CSF biomarkers for dementia, however, are relatively nonspecific. More specific markers may be found by targeting investigations based on knowledge of the molecular pathology of the disease in question. In Alzheimer's disease, hyperphosphorylation of the tau protein is a characteristic feature and thus a comprehensive characterization of the phosphoproteome of the CSF may be pursued to obtain a complete picture of phosphorylation aberrations in health and disease. Toward that goal we here describe a method for a comprehensive isolation and identification of phosphorylated tryptic peptides derived from CSF proteins using a simple sample preparation step and titanium dioxide-affinity chromatography followed by MALDI-TOF or LC-MS/MS linear ion-trap-FT mass spectrometry. Whereas not all previously reported phosphoproteins were found in normal CSF, we detected 56 putative novel phosphorylation sites in 38 proteins in addition to known sites. The approach seems to be a promising foundation for the discovery of new biomarkers embedded in the CSF phosphoproteome.  相似文献   

20.
With the advent of soft ionization methods such as MALDI and ESI, mass spectrometry has become the most important technique for the analysis of proteins and peptides. ESI-MS is often preceded by separation of the peptide sample by reversed-phase liquid chromatography (LC). Acetonitrile (ACN) is the most commonly employed organic solvent in LC-ESI-MS analysis of peptides. In this report, we demonstrate that the use of methanol (MeOH) as the organic modifier improves the detection limits for analysis of peptide mixtures such as those found in tryptic digests of proteins. A nanoLC-ESI-quadrupole ion trap instrument (LCQ Deca, ThermoFinnigan) was used to analyze peptide standards, protein digests of known concentrations, and tryptic digests of 2-DGE-separated proteins. MeOH displayed excellent chromatographic performance (separation and sensitivity), and shorter gradient times were possible for chromatographic separation with MeOH versus ACN. Sensitivity levels of a few hundred attomoles were achieved with MeOH; those levels could not be achieved with ACN. In addition, MeOH-based nanoLC-MS/MS yielded superior results for the analysis of digests of 2-DGE-separated proteins. For the 14 protein spots analyzed, the success rate of protein identification with MeOH-based nanoLC-ESI-MS/MS was 100%, with multiple proteins identified in several of the spots. In contrast, ACN-based procedure failed to identify any proteins in 21% of the spots and overall identified 33% fewer proteins than the MeOH-based procedure. In summary, higher sensitivity and shorter gradient times make MeOH an excellent organic modifier for the use in nanoLC-ESI-MS/MS analysis of peptides.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号