We have developed a simple and accurate method for determining the complete positional isotopomer distribution of aspartate carbon atoms by gas chromatography/tandem mass spectrometry for (13)C-metabolic flux analysis. First, we screened tandem mass spectrometry (MS) spectra of the tert-butyldimethylsilyl (TBDMS) derivative of aspartate for daughter fragments with the necessary carbon atom fragmentations to fully resolve all 16 isotopomers of aspartate. Tandem MS scanning parameters were optimized for each daughter fragment, and the accuracy of tandem MS measurements were evaluated. We selected five accurate fragments that provided a redundant set of 47 labeling measurements to quantify the complete isotopomer distribution of aspartate by least-squares regression. The validity of the approach was demonstrated using six (13)C-labeled aspartate standards and natural aspartate.  相似文献   

2.
针对衍生化-气相色谱串联质谱(选择离子监测法)的操作繁琐费时、过程不易控制的状况,利用离子阱气相色谱质谱联用仪,建立了非衍生化-气相色谱串级质谱直接分析饲料中三聚氰胺的方法.利用三聚氰胺二级质谱进行定性,以二级质谱的特征离子峰m/z85进行定量,检测效率大大提高,定性更加直接.方法精密度为5.9%,回收率为87%-98%,满足饲料中三聚氰胺的检测要求.  相似文献   

3.
An automated gas chromatography/tandem mass spectrometry (GC/MS/MS) based method for the rapid determination of tebufelone (TE) in animal and human plasma has been routinely applied in our laboratory to more than 3000 samples over a 2-year period. The selectivity of MS/MS conducted on a triple quadrupole instrument, combined with the use of a stable-isotope-labeled internal standard, results in excellent analytical figures of merit, as well as minimal sample preparation, rapid analysis, and high assay reliability. The work described here goes beyond initial method development and validation studies by evaluating the long-term performance of quantitative GC/MS/MS. Electron ionization produces M.+ ions for TE and the [13C, 18O]TE internal standard, which are selected in Q1 and undergo collisionally activated dissociation in Q2. Quantitation is based on monitoring daughter ions at m/z 248 and 251, respectively, in Q3. A linear range of 1-3000 ng of TE/sample (20 pg to 60 ng injected) provides access to an effective concentration range of 0.5-30,000 ppb TE in plasma (0.1-2-g samples). The assay shows no bias and less than 10% relative standard deviation over this range. In the automated mode, less than 7 min elapse from injection to report printout and more than 70 plasma samples are routinely prepared and analyzed in a day. Such performance is consistently maintained throughout long-term application.  相似文献   

4.
Successful application of the Hadamard transform (HT) technique to gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS) is described. Novel sample injection devices were developed to achieve multiple sample injections in both GC and LC instruments. Air pressure was controlled by an electromagnetic valve in GC, while a syringe pump and Tee connector were employed for the injection device in LC. Two well-known, abused drugs, 3,4-methylenedioxy-N-methylamphetamine (MDMA) and N, N-dimethyltryptamine (DMT), were employed as model samples. Both of the injection devices permitted precise successive injections, resulting in clearly modulated chromatograms encoded by Hadamard matrices. After inverse Hadamard transformation of the encoded chromatogram, the signal-to-noise (S/N) ratios of the signals were substantially improved compared with those expected from theoretical values. The S/N ratios were enhanced approximately 10-fold in HT-GC/MS and 6.8 in HT-LC/MS, using the matrices of 1023 and 511, respectively. The HT-GC/MS was successfully applied to the determination of MDMA in the urine sample of a suspect.  相似文献   

5.
Microbial metabolomics with gas chromatography/mass spectrometry   总被引:6,自引:0,他引:6  
An analytical method was set up suitable for the analysis of microbial metabolomes, consisting of an oximation and silylation derivatization reaction and subsequent analysis by gas chromatography coupled to mass spectrometry. Microbial matrixes contain many compounds that potentially interfere with either the derivatization procedure or analysis, such as high concentrations of salts, complex media or buffer components, or extremely high substrate and product concentrations. The developed method was extensively validated using different microorganisms, i.e., Bacillus subtilis, Propionibacterium freudenreichii, and Escherichia coli. Many metabolite classes could be analyzed with the method: alcohols, aldehydes, amino acids, amines, fatty acids, (phospho-) organic acids, sugars, sugar acids, (acyl-) sugar amines, sugar phosphate, purines, pyrimidines, and aromatic compounds. The derivatization reaction proved to be efficient (>50% transferred to derivatized form) and repeatable (relative standard deviations <10%). Linearity for most metabolites was satisfactory with regression coefficients better than 0.996. Quantification limits were 40-500 pg on-column or 0.1-0.7 mmol/g of microbial cells (dry weight). Generally, intrabatch precision (repeatability) and interbatch precision (reproducibility) for the analysis of metabolites in cell extracts was better than 10 and 15%, respectively. Notwithstanding the nontargeted character of the method and complex microbial matrix, analytical performance for most metabolites fit the requirements for target analysis in bioanalysis. The suitability of the method was demonstrated by analysis of E. coli samples harvested at different growth phases.  相似文献   

6.
An interface and gas chromatograph oven are described that couple a thermogravimetric analyzer with a mass spectrometer and permit multiple capillary gas chromatographic separations of volatile thermal decomposition products generated during a single thermogravimetric analysis. Examples of the use of this apparatus for identifying the volatile products generated during poly(vinyl butyral) thermal decomposition in the presence of γ-alumina and catalytic cracking of poly(styrene) and poly(ethylene) are described. TG-GC/MS analyses employing isothermal, temperature programmed, and subambient temperature ramp gas chromatography separations are described. The apparatus permits repetitive temperature-programmed capillary gas chromatographic analyses of thermogravimetric effluent containing more than 25 constituents in 3-min intervals.  相似文献   

7.
8.
The isomeric 3- and 4-hydroxyprolines are isobaric with the isomers leucine and isoleucine, and all four have, therefore, the same "residue mass" of 113. Secondary fragmentation processes were found that differentiate the hydroxyproline isomers from each other and from the leucines. Variants of synthetic bradykinin containing one or two hydroxyproline moieties were prepared by using manual Edman degradation and/or enzymatic methods. The tandem mass spectra of these peptides were recorded. The C-terminal wn fragment ions allow the differentiation of 4-hydroxyproline from the 3-isomer and isoleucine, while the N-terminal an ions containing 4-hydroxyproline undergo H2O elimination to differentiate this amino acid from the 3-isomer and leucine. Lys-C digestion of a mussel adhesive protein produced a set of decapeptides varying in the degree of hydroxylation of proline and tyrosine. Heterogeneity with respect to 3-hydroxyproline and 4-hydroxyproline at a certain position in these peptides was assessed by tandem mass spectrometry based on the wn ion series in the CID spectra of these Lys-C peptides. Some N-terminal ions further allow for the differentiation of these two isomeric species.  相似文献   

9.
The native reference peptide (NRP) method has been adapted to the measure of the degree of protein nitration at a specific tyrosine residue. In these experiments, human serum albumin was modified in a myeloperoxidase-mediated reaction in the presence of nitrite, with nitration detected predominantly at one site, Y162. The time-dependent increase in nitration at this site was measured based on the increasing abundance of the peptide 162YnLYEIAR168 and the corresponding decrease in the 162YLYEIAR168 peptide in in-gel trypsin digests. The peptide 66LVNEVTEFAK75, also formed in the tryptic digest, was used as the native reference peptide. Quantitation was achieved by determining the chromatographic peak area of the two analyte peptides relative to the native reference peptide by LC/tandem mass spectrometric analyses with selected reaction monitoring. The NRP results were validated by correlation to the time-dependent increase in total protein-nitrotyrosine content determined by Western blot analysis. The precision and limit of detection of the assay were also evaluated and were found to be approximately 10% (relative standard deviation) and 5 fmol on-column, respectively. These results demonstrate the utility of the NRP method for quantitative analyses of posttranslation modifications, in terms of broad applicability, ease of experimental design, sensitivity, and precision.  相似文献   

10.
11.
12.
Kapp T  Vetter W 《Analytical chemistry》2006,78(23):8156-8161
The use of vial closures equipped with butyl rubber septa may lead to sample contamination by rubber additives discharging from the septum material. In this study, the structure elucidation of an artifact causing intense signals in gas chromatography/electron capture negative ion mass spectrometry (GC/ECNI-MS) and gas chromatographic analyses with electron capture detection is described. Tentative identification of the leached compound was achieved by employing tandem mass spectrometric techniques both in electron capture negative ion and in electron ionization modes. The artifact could thus be characterized as 2-benzothiazolyl-N,N-dimethyl dithiocarbamate, which is a known vulcanization accelerator for rubber. It is conceivable that the identified compound or related substances are also used in other applications. Therefore, two food-related matrixes were investigated for a possible migration of this compound into foods. During these analyses, the tentatively identified rubber additive was detected in an aqueous extract of a rubber seal ring for canning jars. GC/ECNI-MS provided better sensitivity and selectivity than GC/EI-MS for the determination of the rubber additive and other mercaptobenzothiazole-derived substances.  相似文献   

13.
Hyperforin is one of the essential active ingredients of St. John's wort extract, which is used as an antidepressant for mild to moderately severe depressions. In vitro and in vivo data as well as several clinical studies and meta analyses have confirmed the pharmacological effect of treatment with hyperforin-containing preparations. However, little is known about the brain availability of hyperforin until now. Accordingly, a highly sensitive and selective LC/MS method for this purpose was developed and validated. This method proved suitable for the determination of hyperforin in mouse brain, after oral administration of hyperforin sodium salt and St. John's wort extract. This method involves liquid-liquid extraction of hyperforin with ethyl acetate followed by separation with rapid reversed-phase high-performance liquid chromatography and tandem mass spectrometry detection using electrospray ionization. Excellent linearity was obtained for the entire calibration range from 0.25 to 10 ng/mL (corresponding to 2.5-100 ng/g brain tissue concentration, calculated with the factor derived from sample processing) with an average coefficient of correlation of 0.9992. The recovery of hyperforin from mouse brain homogenates was between 71.4 and 75.3% with a relative standard deviation of less than 3%. Validation assays for the lower limit of quantitation yielded an accuracy of 5.8%. Intraday accuracy and precision for the developed method were between 4.6 and 10.6% and 4.3-8.4%, respectively, while the interday parameters varied between 6.7 and 12.2% for accuracy and 2.0-5.0% for precision. After the method validation, hyperforin brain levels in mice, treated with 15 mg/kg hyperforin (either as the sodium salt or as 5% St. John's wort extract), were investigated. The average concentration of hyperforin found for the sodium salt group was 28.8+/-10.1 ng/g of brain (n = 8), which was somewhat higher than the hyperforin concentration of 15.8+/-10.9 ng/g of brain (n = 8), determined in the extract-treated group. This method is robust, selective, and highly sensitive and represents an appropriate tool to further prove the occurrence and distribution of hyperforin in mouse brain.  相似文献   

14.
Davis WE  Li Y 《Analytical chemistry》2008,80(14):5449-5453
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.  相似文献   

15.
16.
Alkylbenzenesulfonates together with soap are the most widely used anionic surfactants. Linear alkylbenzenesulfonates (LAS) were introduced in the mid-1960s as substitutes for the poorly biodegradable tetrapropylenebenzenesulfonates (TPS). A method is presented for the selective and quantitative determination of LAS and TPS in recent sediments. Alkylbenzenesulfonates were extracted from sediments using methanol. The methanolic extract was passed through a strong anionic exchange column. The alkylbenzenesulfonates contained in the acidic eluate were then derivatized to their corresponding trifluoroethyl esters and quantitatively determined by gas chromatography/mass spectrometry using positive chemical ionization. Limits of quantitation for 10 g sediment samples varied between 1.5 and 21 μg/kg of dry sediment for single LAS isomers and between 71 and 220 μg/kg for total LAS. Limits of quantitation for the total of TPS were at ~200 μg/kg. Relative standard deviations of replicate analyses typically ranged from 5 to 10%. Recovery rates of LAS in spiked sediment samples ranged from 79 to 113%. The presented method was applied to surface and subsurface sediments also containing long-chain (C(14)-C(16))-LAS and mixtures of LAS and TPS.  相似文献   

17.
Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of (37)Cl/(35)Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ(37)Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1‰), to GC/qMS (1σ ≈ 0.2-0.5‰ for Agilent GC/qMS and 1σ ≈ 0.2-0.9‰ for Thermo GC/qMS). Nonetheless, δ(37)Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications.  相似文献   

18.
19.
This study establishes the rationale necessary for determining the time to change engine oil. This is based on identifying gaseous components in new and used automobile lubricants. Key compounds, so-called "signature", are separated and identified qualitatively by coupled gas chromatography/mass spectrometry. Volatile antioxidants at zero miles and fuel contaminants at low mileage are observed in the headspace of engine oil. Several oxidative degradation components have been positively identified in the used oil, which include the following: acetaldehyde, acetone, butanal, 2-propanol, acetic acid, 2-hexanol, benzoic acid, benzaldehyde, and 1-pentanol. This study strongly suggests that the status of lubricating oil can be determined by the analysis of the gas phase above the oil. Most importantly, it opens the possibility of performing conditional maintenance of the combustion engine based on information obtained from gas sensors.  相似文献   