 共查询到20条相似文献,搜索用时 15 毫秒
1.
Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as a powerful tool of broad utility for separation and characterization of gas-phase ions, especially in conjunction with mass spectrometry (MS). In FAIMS, ions are filtered by the dependence of mobility on electric field while being carried by gas flow through the analytical gap between two electrodes of either planar (p-) or cylindrical (c-) geometry. Most FAIMS/MS systems employ c-FAIMS because of its ease of coupling to MS, yet the merits of the two geometries have not been compared in detail. Here, a priori simulations reveal that reducing the FAIMS curvature always improves resolution at equal sensitivity. In particular, the resolving power of p-FAIMS exceeds that of c-FAIMS, typically by a factor of 2-4 depending on the ion species and carrier gas. We have constructed a new planar FAIMS incorporating a curtain plate interface for effective operation with an ESI ion source and joined to an MS using an ion funnel interface with a novel slit aperture. The resolution increases up to 4-fold over existing c-FAIMS, even though the analysis is approximately 2 times faster. This allows separation of species not feasible in previous FAIMS studies, e.g., protonated leucine and isoleucine or new bradykinin isomers. The improvement for protein conformers (of ubiquitin) is less significant, possibly because of multiple unresolved geometries.  相似文献   

2.
The lower limit of detection for low molecular weight polar and ionic analytes using electrospray ionization-mass spectrometry (ESI-MS) is often severely compromised by an intense background that obscures ions of trace components in solution. Recently, a new technique, referred to as high-field asymmetric waveform ion mobility spectrometry (FAIMS), has been shown to separate gas-phase ions at atmospheric pressure and room temperature. A FAIMS instrument is an ion filter that may be tuned, by control of electrical voltages, to continuously transmit selected ions from a complex mixture. This capability offers significant advantages when FAIMS is coupled with ESI, a source that generates a wide variety of ions, including solvent clusters and salt adducts. In this report, the tandem arrangement of ESI-FAIMS-MS is used for the analysis of haloacetic acids, a class of disinfection byproducts regulated by the US EPA. FAIMS is shown to effectively discriminate against background ions resulting from the electrospray of tap water solutions containing the haloacetic acids. Consequently, mass spectra are simplified, the selectivity of the method is improved, and the limits of detection are lowered compared with conventional ESI-MS. The detection limits of ESI-FAIMS-MS for six haloacetic acids ranged between 0.5 and 4 ng/mL in 9:1 methanol/tap water (5 and 40 ng/mL in the original tap water samples) with no preconcentration, derivatization, or chromatographic separation prior to analysis.  相似文献   

3.
Amphetamine, methamphetamine, and their methylenedioxy derivatives have been identified and measured in a human urine matrix using solid-phase microextraction (SPME) and high-field asymmetric waveform ion mobility spectrometry (FAIMS) in combination with electrospray ionization (ESI) and mass spectrometric detection (MS). Limits of detection in human urine between 200 pg/mL and 7.5 ng/mL have been achieved. The use of a simple extraction method, SPME, combined with the high sensitivity and selectivity of ESI-FAIMS-MS eliminates the need for chromatographic separation and allows for very rapid sample processing.  相似文献   

4.
The combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) makes possible lower detection limits, increased sensitivity, and increased dynamic range in the analysis of poly(ethylene glycol) (PEG) samples of low molecular weight. The signal gain obtained using FAIMS depends on ion identity, with a range between 1.8x and 14x obtained for various molecular ions of PEG 600. A 1.7-fold reduction in noise is obtained using FAIMS due to the elimination of chemical noise. The improved detection performance is predominantly due to a reduction in adverse Coulomb effects as a result of ions being selectively introduced into the mass spectrometer. The high ion transmission obtained using FAIMS combined with the high sensitivity of FTICR-MS detection make possible separation of multiple gas-phase conformers of PEG molecular cations that have low abundance (less than 0.2% relative abundance) and that have not been detected previously. Mixed dications of PEG that have the same nominal mass but differ by the number polymer subunits (m/Delta m up to 25,000) can be separately introduced into the mass spectrometer using FAIMS. Interactions of the carrier gas with the metal ions that are attached to the PEG molecules appear to be the most significant factor in these FAIMS separations.  相似文献   

5.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new technique that separates gas-phase ions at atmospheric pressure (760 Torr) and room temperature. A FAIMS instrument acts as an ion filter and can be set to continuously transmit one type of ion. Despite the stringent requirement for a flow of clean, dry gas in the FAIMS analyzer region, a method of coupling electrospray to FAIMS has been developed. The identity of the electrospray ions separated by FAIMS was determined using mass spectrometry (FAIMS-MS). The theory of FAIMS is discussed, and electrospray FAIMS-MS spectra of several compounds in modes P1, P2, N1, and N2 are presented. Ions appearing in P1 and N1 modes tend to have mobilities that increase as a function of increasing electric field strength, whereas ions appearing in P2 and N2 modes tend to have mobilities that decrease. In general, low-mass ions are focused in P1 and N1 modes, whereas larger ions (e.g., proteins) are focused in P2 and N2 modes. Short-chain peptides, (Gly)(n) where n = 1-6, are shown to cross over from P1 mode into P2 mode as the chain length increases. The removal of the low-mass solvent cluster ions, combined with a reduction of the background noise in electrospray FAIMS-MS, results in an improved signal-to-noise ratio for mass spectra of larger ions (e.g., cyctochrome c) when compared with conventional electrospray-MS. Preliminary results also suggest that various charge states of cytochrome c can be distinguished by FAIMS, implying that the ion mobility of these species at high electric field strength is sensitive to the structure of the protein ion. The linearity of response of electrospray FAIMS-MS was investigated using leucine enkephalin and shows the calibration curve to be linear for ~3 orders of magnitude.  相似文献   

6.
Field asymmetric waveform ion mobility spectrometry (FAIMS) has emerged as an analytical tool of broad utility, especially in conjunction with mass spectrometry. Of particular promise is the use of FAIMS and 2-D ion mobility methods that combine FAIMS with conventional IMS to resolve and characterize protein and other macromolecular conformers. However, FAIMS operation requires a strong electric field, and ions are inevitably heated by energetic collisions with buffer gas molecules. This may induce ion isomerization or dissociation, which distort the separation properties of FAIMS (and subsequent stages) or reduce instrumental sensitivity. As FAIMS employs a periodic waveform, whether those processes are controlled by ion temperature at maximum or average field intensity has been debated. Here we address this issue by measuring the unfolding of compact ubiquitin ion geometries as a function of waveform amplitude (dispersion field, E(D)) and gas temperature, T. The field heating is quantified by matching the dependences of structural transitions on E(D) and T: increasing E(D) from 12 to 16 or from 16 to 20 kV/cm is equivalent to heating the (N2) gas by approximately 15-25 degrees C. The magnitude of field heating for any E(D) can be estimated using the two-temperature theory, and raising E(D) by 4 kV/cm augments heating by approximately 15-30 degrees C for maximum and approximately 4-8 degrees C for average field in the FAIMS cycle. Hence, isomerization of ions in FAIMS appears to be determined by the excitation at waveform peaks.  相似文献   

7.
Nearly a decade after first commercialization, high field asymmetric waveform ion mobility spectrometry (FAIMS) has yet to find its place in routine chemical analysis. Prototypes have been used to demonstrate the utility of this separation technique combined with mass spectrometry (MS). Unfortunately, first generation commercial FAIMS instruments have gone practically unused by early adopters. Here, we show this to be due to poor ion transmission in the FAIMS-MS source interface. We present simple instrumental modifications and optimization of experimental conditions to achieve good performance from the first generation commercial FAIMS device (the Ionalytics Selectra) coupled to a high resolution Q-TOF-MS. In combination with nanospray ionization, we demonstrate for the first time the nontarget analysis of urine by FAIMS with minimal sample preparation. We show the unique suitability of electrospray ionization (ESI)-FAIMS-MS for identification of low abundance species such as urinary biomarkers of damage of nucleic acids in a complex biological matrix. The elimination of electrospray noise and matrix components by FAIMS and the continuous flow of analytes through FAIMS for accurate and tandem mass analysis produce high quality spectral data suitable for structural identification of unknowns. These characteristics make ESI-FAIMS-MS ideal for nontarget identification, even when compared to high efficiency LC-ESI-MS.  相似文献   

8.
A combination of electrospray ionization, high-field asymmetric waveform ion mobility spectrometry, and mass spectrometry (ESI-FAIMS-MS) was used for the analysis of a solution containing a mixture of the nine chlorinated and brominated haloacetic acids. For a carrier gas of nitrogen in the FAIMS analyzer, haloacetate anions of the mono- and dihalogenated acids and the decarboxylated anions of three of the trihalogenated acids were detected. No signal was observed for bromodichloroacetic acid (BDCAA) at a dispersion voltage of -3400 V. The addition of a small amount of carbon dioxide to the nitrogen carrier gas resulted in the detection of the pseudomolecular trihaloacetate anions, including BDCA-, and significant increases in sensitivities for the trihalogenated species. The addition of carbon dioxide to the nitrogen carrier gas had little effect on the mono- and dihalogenated anions. Quantitative analysis of the nine haloacetic acids, using flow injection, gave detection limits between 5 and 36 parts-per-trillion in 9/1 methanol/water (v/v) containing 0.2 mM ammonium acetate.  相似文献   

9.
High-field asymmetric waveform ion mobility spectrometry (FAIMS) is a new technology for atmospheric pressure, room temperature separation of gas-phase ions. The FAIMS system acts as an ion filter that can continuously transmit one type of ion, independent of mass-to-charge ratio (m/z). Capillary electrophoresis-electrospray mass spectrometry (CE-MS) has been extensively used for the analysis of complex bacterial lipopolysaccharides (LPS). The coupling of FAIMS to CE-MS provides a sensitive technique for the characterization of these complex glycolipids, permitting the separation of trace-level LPS oligosaccharide glycoforms for subsequent structural characterization using tandem mass spectrometry. This was demonstrated for LPS from nontypeable Haemophilus influenzae strain 375 following O-deacylation with anhydrous hydrazine. This strain of H. influenzae can express a triheptosyl-containing glycoform to which four hexose residues are linked forming the outer-core region of the molecule. This has been referred to as the Hex4 glycoform. Glycoforms have been identified which differ in the number of phosphoethanolamine substituents in the inner-core. With the use of CE-FAIMS, isomeric Hex4 glycoforms containing two PEtn groups were separated and characterized by MS/MS. FAIMS provided a significant reduction in mass spectral noise, leading to improved detection limits ( approximately 70 amol of the major glycoform). The extracted mass spectrum showed that the apparent noise was virtually eliminated. In addition to the reduction of chemical background, the ion current was increased by as much as 7.5 times as a result of the atmospheric pressure ion-focusing effect provided by the FAIMS system. The linearity of response of the CE-FAIMS-MS system was also studied. The calibration curve is linear for approximately 3 orders of magnitude, over a range of 40 pg/microL to 10 ng/microL.  相似文献   

10.
Field asymmetric waveform ion mobility spectrometry (FAIMS) is emerging as a major analytical tool, especially in conjunction with mass spectrometry (MS), conventional ion mobility spectrometry (IMS), or both. In particular, FAIMS is used to separate protein or peptide conformers prior to characterization by IMS, MS/MS, or H/D exchange. High electric fields in FAIMS induce ion heating, previously estimated at <10 degrees C on average and believed too weak to affect ion geometries. Here we use a FAIMS/IMS/MS system to compare the IMS spectra for ESI-generated ubiquitin ions that have and have not passed FAIMS and find that some unfolding occurs for most charge states. These data and their comparison with the reported protein unfolding in a Paul trap imply that at least some structural transitions observed in FAIMS, or previously in an ion trap, are not spontaneous. The observed unfolding is similar to that produced by heating of approximately 50 degrees C above room temperature, consistent with the calculated heating of ions at FAIMS waveform peaks. Hence, the ion isomerization in FAIMS likely proceeds in steps during the "hot" periods, especially right after entering the device. The process distorts ion geometries and causes ion losses by a "self-cleaning" mechanism and thus should be suppressed as much as possible. We propose achieving that via cooling FAIMS by the amount of ion heating; in most cases, cooling by approximately 75 degrees C should suffice.  相似文献   

11.
Ion mobility spectrometry (IMS), and particularly differential IMS or field asymmetric waveform IMS (FAIMS), is emerging as a versatile tool for separation and identification of gas-phase ions, especially in conjunction with mass spectrometry. For over two decades since its inception, the utility of FAIMS was constrained by resolving power (R) of less than ~20. Stronger electric fields and optimized gas mixtures have recently raised achievable R to ~200, but further progress with such approaches is impeded by electrical breakdown. However, the resolving power of planar FAIMS devices using any gas and field intensity scales as the square root of separation time (t). Here, we extended t from the previous maximum of 0.2 s up to 4-fold by reducing the carrier gas flow and increased the resolving power by up to 2-fold as predicted, to >300 for multiply charged peptides. The resulting resolution gain has enabled separation of previously "co-eluting" peptide isomers, including folding conformers and localization variants of modified peptides. More broadly, a peak capacity of ~200 has been reached in tryptic digest separations.  相似文献   

12.
Field asymmetric waveform ion mobility spectrometry (FAIMS) has significant potential for post-ionization separations in conjunction with MS analyses. FAIMS fractionates ion mixtures by exploiting the fact that ion mobilities in gases depend on the electric field in a manner specific to each ion. Nearly all previous work has used pure gases, for which FAIMS fundamentals are understood reasonably well; however, unexpected phenomena observed in some gas mixtures (e.g., N(2)/CO(2)) but not in others (N(2)/O(2)) remain unexplained. Here, we introduce and experimentally test a universal model for FAIMS separations in mixtures, derived from formalisms that determine high-field mobilities in heteromolecular gases. Overall, the theoretical findings are consistent with data for N(2)/CO(2) (although quantitative discrepancies remain), while results for N(2)/O(2) fit Blanc's law, in agreement with measurements. Calculations for He/N(2) and He/CO(2) are also consistent with observations and suggest why adding He to the working gas generally enhances FAIMS performance. As predicted, mixtures of gases with extremely disparate molecular masses and collision cross sections, such as He/SF(6), exhibit spectacular non-Blanc effects, which greatly improve the resolution and peak capacity of technique. Understanding FAIMS operation in gas mixtures is expected to enable the rational design of media for both targeted and global analyses.  相似文献   

13.
We present a new method for separation of enantiomers with high-field asymmetric waveform ion mobility spectrometry (FAIMS), coupled to mass spectrometric detection. Upon addition of an appropriate chiral reference compound to the analyte solution and subsequent ionization of the solution by electrospray ionization, analyte enantiomers formed diastereomeric complexes, which were potentially separable by FAIMS. The methodology being developed is intended to be general, but here amino acid analytes are specifically considered. In the examples presented herein, six pairs of amino acid enantiomers were successfully separated as metal-bound trimeric complexes of the form [MII(L-Ref)2(D/L-A)-H]+, where MII is a divalent metal ion, L-Ref is an amino acid in its L form acting as chiral reference compound, and A is the amino acid analyte. For example, D- and L-tryptophan were separated in FAIMS as [NiII(L-Asn)2(D-Trp)-H]+ and [NiII(L-Asn)2(L-Trp)-H]+. As FAIMS separation typically takes place over a time scale of only a few hundred milliseconds, the presented separation method opens new possibilities for rapid analysis of one analyte enantiomer in the presence of the other enantiomer. Preliminary quantification results are presented, which suggest that fast and sensitive quantitative chiral analyses can be performed with FAIMS. Method limitations are discussed in terms of diverse phenomena, which are not yet understood.  相似文献   

14.
Recently, we introduced a new approach to chiral separation and analysis of amino acids by chiral complexation and electrospray high-field asymmetric waveform ion mobility spectrometry coupled to mass spectrometry (ESI-FAIMS-MS). In the present work, we extended this approach to the separation of the drug compound terbutaline. Terbutaline enantiomers were complexed with metal ions and an amino acid to form diastereomeric complexes of the type [M(II)(L-Ref)2((+)/(-)-A)-H](+), where M(II) is a divalent metal ion, L-Ref is an amino acid in its L-form, and A is the terbutaline analyte. When metal and reference compound were suitably chosen, these complexes were separable by FAIMS. We also detected and characterized larger clusters that were transmitted at distinct FAIMS compensation voltages (CV), disturbing data analysis by disintegrating after the FAIMS separation and forming complexes of the same composition [M(II)(L-Ref)2((+)/(-)-A)-H](+), thus giving rise to additional peaks in the FAIMS CV spectra. This undesired phenomenon could be largely avoided by adjusting the mass spectrometer skimmer voltages in such a way that said larger clusters remained intact. In the quantitative part of the present work, we achieved a limit of detection of 0.10% (-)-terbutaline in a sample of (+)-terbutaline. The limit of detection and analysis time per sample compared favorably to literature values for chiral terbutaline separation by HPLC and CE.  相似文献   

15.
Miniaturized ultra high field asymmetric waveform ion mobility spectrometry (FAIMS) is used for the selective transmission of differential mobility-selected ions prior to in-source collision-induced dissociation (CID) and time-of-flight mass spectrometry (TOFMS) analysis. The FAIMS-in-source collision induced dissociation-TOFMS (FISCID-MS) method requires only minor modification of the ion source region of the mass spectrometer and is shown to significantly enhance analyte detection in complex mixtures. Improved mass measurement accuracy and simplified product ion mass spectra were observed following FAIMS preselection and subsequent in-source CID of ions derived from pharmaceutical excipients, sufficiently close in m/z (17.7 ppm mass difference) that they could not be resolved by TOFMS alone. The FISCID-MS approach is also demonstrated for the qualitative and quantitative analysis of mixtures of peptides with FAIMS used to filter out unrelated precursor ions thereby simplifying the resulting product ion mass spectra. Liquid chromatography combined with FISCID-MS was applied to the analysis of coeluting model peptides and tryptic peptides derived from human plasma proteins, allowing precursor ion selection and CID to yield product ion data suitable for peptide identification via database searching. The potential of FISCID-MS for the quantitative determination of a model peptide spiked into human plasma in the range of 0.45-9.0 μg/mL is demonstrated, showing good reproducibility (%RSD < 14.6%) and linearity (R(2) > 0.99).  相似文献   

16.
Flow injection high field asymmetric waveform ion mobility spectrometry (FAIMS)-mass spectrometry (MS) methodology was developed for the detection and identification of chemical warfare (CW) agents in spiked food products. The CW agents, soman (GD), sarin (GB), tabun (GA), cyclohexyl sarin (GF), and four hydrolysis products, ethylphosphonic acid (EPA), methylphosphonic acid (MPA), pinacolyl methylphosphonic acid (Pin MPA), and isopropyl methylphosphonic acid (IMPA) were separated and detected by positive ion and negative ion atmospheric pressure ionization-FAIMS-MS. Under optimized conditions, the compensation voltages were 7.2 V for GD, 8.0 V for GA, 7.2 V for GF, 7.6 V for GB, 18.2 V for EPA, 25.9 V for MPA, -1.9 V for PinMPA, and +6.8 V for IMPA. Sample preparation was kept to a minimum, resulting in analysis times of 3 min or less per sample. The developed methodology was evaluated by spiking bottled water, canola oil, cornmeal, and honey samples at low microgram per gram (or microg/mL) levels with the CW agents or CW agent hydrolysis products. The detection limits observed for the CW agents in the spiked food samples ranged from 3 to 15 ng/mL in bottled water, 1-33 ng/mL in canola oil, 1-34 ng/g in cornmeal, and 13-18 ng/g in honey. Detection limits were much higher for the CW agent hydrolysis products, with only MPA being detected in spiked honey samples.  相似文献   

17.
Differential ion mobility spectrometry (FAIMS) integrated with mass spectrometry (MS) is a powerful new tool for biological and environmental analyses. Large proteins occupy regions of FAIMS spectra distinct from peptides, lipids, or other medium-size biomolecules, likely because strong electric fields align huge dipoles common to macroions. Here we confirm this phenomenon in separations of proteins at extreme fields using FAIMS chips coupled to MS and demonstrate their use to detect even minor amounts of large proteins in complex matrixes of smaller proteins and peptides.  相似文献   

18.
Because of health concerns surrounding widespread exposure to perchlorate, we developed a sensitive and selective method for quantifying perchlorate in human urine using ion chromatography coupled with electrospray ionization tandem mass spectrometry. Perchlorate was quantified using a stable isotope-labeled internal standard ((18)O(4)-perchlorate) with excellent assay precision (coefficient of variation <5% for repetitively analyzed quality control material). Analytical accuracy was established by blind analysis of certified proficiency testing materials prepared in synthetic urine matrix; calculated amounts deviated minimally from true amounts, with percent differences ranging from 2% to 5%. Selective chromatography and tandem mass spectrometry reduced the need for sample cleanup, resulting in a rugged and rapid method capable of routinely analyzing 75 samples/day. The lowest reportable level (0.025 ng/mL) was sufficiently sensitive to detect perchlorate in all human urine samples evaluated to date, with a linear response range from 0.025 to 100 ng/mL. This selective, sensitive, and rapid method will help elucidate any potential associations between human exposure to low levels of perchlorate and adverse health effects.  相似文献   

19.
Electrospray ionization (ESI) high-field asymmetric waveform ion mobility spectrometry (FAIMS) was combined with quadrupole, time-of-flight, and tandem mass spectrometry to characterize commercial and naturally occurring naphthenic acids (NA) mixtures. This new method provides quantitatively reliable mass and isomer distributions of NA components in approximately 3 min without extensive sample preparation. ESI-FAIMS-MS seems to be especially useful for characterization of fragile ions that cannot be detected by other methods. A unique part of this technique is separation of structural isomers that proved to be critical in determination of elemental composition and in structure elucidation. Tandem mass spectrometry of NA ions separated by FAIMS provides more information about the structure of NA than other methods in the field of NA analysis.  相似文献   

20.
The analysis of intact glycopeptides by mass spectrometry is challenging due to the numerous possibilities for isomerization, both within the attached glycan and the location of the modification on the peptide backbone. Here, we demonstrate that high field asymmetric wave ion mobility spectrometry (FAIMS), also known as differential ion mobility, is able to separate isomeric O-linked glycopeptides that have identical sequences but differing sites of glycosylation. Two glycopeptides from the glycoprotein mucin 5AC, GT(GalNAc)TPSPVPTTSTTSAP and GTTPSPVPTTST(GalNAc)TSAP (where GalNAc is O-linked N-acetylgalactosamine), were shown to coelute following reversed-phase liquid chromatography. However, FAIMS analysis of the glycopeptides revealed that the compensation voltage ranges in which the peptides were transmitted differed. Thus, it is possible at certain compensation voltages to completely separate the glycopeptides. Separation of the glycopeptides was confirmed by unique reporter ions produced by supplemental activation electron transfer dissociation mass spectrometry. These fragments also enable localization of the site of glycosylation. The results suggest that glycan position plays a key role in determining gas-phase glycopeptide structure and have implications for the application of FAIMS in glycoproteomics.  相似文献   