首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Radial modulation imaging is a new promising technique to improve contrast-enhanced ultrasound images. The method is based on dual-frequency insonation of contrast agent microbubbles. A low-frequency (LF) pulse is used to modulate the responses of the microbubbles to a high-frequency (HF) imaging pulse. Inverting the LF pulse induces amplitude and phase differences in the HF response of contrast agent microbubbles, which can be detected using Doppler techniques. Although the technique has been successfully implemented, no consensus persists on parameter choice and resulting effects. In a separate study, "compression-only" behavior of coated microbubbles was observed. Compression-only behavior could be beneficial for radial modulation imaging. This was investigated using high-speed camera recordings and simulations. We recorded the vibrations of 78 single microbubbles in a dual-frequency ultrasound field. The results showed that the LF pulse induced significant compression-only behavior, which for microbubble sizes below and at HF resonance resulted in high radial amplitude modulation. It, however, also appeared that, for radial modulation imaging, microbubble size is more important than resonance and compression-only effects.  相似文献   

2.
A contrast agent detection method is presented that potentially can improve the diagnostic significance of ultrasound contrast agents. Second order ultrasound field (SURF) contrast imaging is achieved by processing the received signals from transmitted dual frequency band pulse complexes with overlapping high-frequency (HF) and low-frequency (LF) pulses. The transmitted HF pulses are used for image reconstruction, whereas the transmitted LF pulses are used to manipulate the scattering properties of the contrast agent. In the present paper, we discuss how SURF contrast imaging potentially can overcome problems and limitations encountered with available contrast agent detection methods, and we give a few initial examples of in vitro measurements. With SURF contrast imaging, the resonant properties of the contrast agent may be decoupled from the HF imaging pulses. This technique is thus especially interesting for imaging contrast bubbles above their resonance frequency. However, to obtain adequate specificity, it is typically necessary to estimate and correct for accumulative nonlinear effects in the forward wave propagation.  相似文献   

3.
Microbubble contrast agents produce nonlinear echoes under ultrasound insonation, and current imaging techniques detect these nonlinear echoes to generate contrast agent images accordingly. For these techniques, there is a potential problem in that bubbles along the ultrasound transmission path between transducer and target can alter the ultrasound transmission nonlinearly and contribute to the nonlinear echoes. This can lead to imaging artefacts, especially in regions at depth. In this paper we provide insight, through both simulation and experimental measurement, into the nonlinear propagation caused by microbubbles and the implications for current imaging techniques. A series of investigations at frequencies below, at, and above the resonance frequency of microbubbles were performed. Three specific effects on the pulse propagation (i.e., amplitude attenuation, phase changes, and harmonic generation) were studied. It was found that all these effects are dependent on the initial pulse amplitude, and their dependence on the initial phase of the pulse is shown to be insignificant. Two types of imaging errors are shown to result from this nonlinear propagation: first, that tissue can be misclassified as microbubbles; second, the concentration of microbubbles in the image can be misrepresented. It is found that these imaging errors are significant for all three pulse frequencies when the pulses transmit through a microbubble suspension of 6 cm in path length. It also is found that the first type of error is larger at the bubble resonance frequency.  相似文献   

4.
Targeted contrast agents and ultrasound imaging are now used in combination for the assessment and tracking of biomarkers in animal models in vivo. These applications have triggered interest in the understanding and prediction of the ultrasound echoes from contrast agents attached to cells. This study describes the reflection enhancement due to microbubbles bound on a gelatin surface. The reflection enhancement was measured using ultrasound pulses at high frequency (40 MHz) and low pressure (38 kPa peak-negative pressure) allowing a linear approximation to be applied. The observed reflection coefficient increased with the number of microbubbles, until reaching saturation at 0.9 when the surface coverage fraction was 35%. A multiple scattering model assuming that the targeted microbubbles are confined within an infinitesimally thin layer appeared suitable in predicting the reflection coefficient even at very high surface densities. These results could permit the optimization of the sensitivity of high frequency ultrasound to targeted contrast agents.  相似文献   

5.
Stimulating high-frequency nonlinear oscillations of ultrasound contrast agents is helpful to distinguish microbubbles from background tissues. Nevertheless, inefficiency of such oscillations from most commercially available contrast agents and intense attenuation of the resultant high-frequency harmonics limit microbubble detection with high-frequency ultrasound. To avoid this high-frequency nature, we devised and explored a dual-frequency difference excitation technique to induce efficiently low-frequency, rather than high-frequency, nonlinear scattering from microbubbles by using high-frequency ultrasound. The proposed excitation pulse is comprised of 2 high-frequency sinusoids with frequency difference subject to the microbubble resonance frequency. Its envelope, with frequency being the difference between the 2 frequencies, is used to stimulate nonlinear oscillation of microbubbles for the consonant low-frequency harmonic generation, whereas high-imaging resolution is retained because of narrow high-frequency transmit beams. Hydrophone measurements and phantom experiments of speckle-generating flow phantoms were performed to demonstrate the efficacy of the proposed technique. The results show that, especially when the envelope frequency is near the microbubbleiquests resonance frequency, the envelope of the proposed excitation pulse can induce significant nonlinear scattering from microbubbles, the induced nonlinear responses tend to increase with the pulse pressures, and up to 26 dB and 36 dB contrast-to-tissue ratios with second- and fourth-order nonlinear responses, respectively, can be obtained. Potential applications of this method include microbubble fragmentation and cavitation with high-frequency ultrasound.  相似文献   

6.
SURF contrast imaging, as described previously in the literature, is a contrast agent detection technique achieved by processing of the received signals from transmitted dual frequency band pulse complexes with overlapping high-frequency (HF) and low-frequency (LF) pulses. The transmitted HF pulses are used for image reconstruction, whereas the transmitted LF pulses are used to manipulate the scattering properties of the contrast agent. As with harmonic contrast agent detection techniques, nonlinear wave propagation will, in most situations, also limit the specificity with the SURF contrast technique when transmitting overlapping HF and LF pulses. The present paper proposes an alternative SURF contrast imaging technique using transmit dual frequency band pulse complexes with non-overlapping HF and LF pulses. If the frequency of the LF manipulation pulse is close to the bubble resonance frequency, numerical simulations indicate a significant ring-down effect of the LF bubble radius response. Utilizing this bubble ring-down effect and transmitting the HF pulse just after the LF pulse, a contrast agent specificity approaching infinity accompanied by a contrast agent sensitivity only for contrast bubbles having resonance frequencies within a narrow frequency range may be obtained.  相似文献   

7.
The effect of the phase of transmission on contrast agent echoes   总被引:1,自引:0,他引:1  
Ultrasound contrast agents consist of a gas bubble, encapsulated by a shell for stabilization. The shell dampens the fluctuations in the bubble radius when insonified. The detection of contrast microbubbles during a medical examination can indicate whether a region is perfused with blood. Here, the authors consider the effect of the phase of sonification signal on the backscatter by the bubble echo. By transmitting two short pulses of ultrasound with opposite phases, the authors demonstrate that a unique pair of echoes can be generated by a single microbubble, and that the properties of these echoes may be useful in the discrimination of bubble and tissue echoes. Specifically, the significant echo amplitude begins coincident with each transmitted rarefactional half-cycle, and the mean frequency of this echo depends on the transmitted phase. When rarefaction is transmitted first for a 2.25 MHz signal, the mean frequency is 0.8 MHz higher for an albumin-shelled bubble and 0.9 MHz higher for a lipid-shelled bubble. The experimental results agree with the predictions of the Gilmore-Akulichev equation.  相似文献   

8.
Shell waves and acoustic scattering from ultrasound contrast agents   总被引:1,自引:0,他引:1  
Ultrasound contrast agents are encapsulated microbubbles, filled either with air or a higher weight molecular gas, ranging in size from 1 to 10 μm in diameter. The agents are modeled as air-filled spherical elastic shells of variable thickness and material properties. The scattered acoustic field is computed from a modal series solution, and reflectivity and angular scattering are then determined from the computed fields for agents of various properties. We show that contrast agents also support shell resonance responses in addition to the monopole response, which has been the focus of previous contrast agent studies. Lamb waves appear to be the source of these additional responses. A shell or curvature Lamb wave generates dipole peaks in the 1- to 40-MHz range for 2.5 to 3.5 μm radius agents with elastic properties approximating those of albumin protein. The inclusion of damping affects the lower frequency dipole peaks but is less important for responses occurring above approximately 30 MHz. Moreover, these responses hold untapped potential for clinical ultrasound applications such as tissue perfusion studies and high frequency contrast agent imaging  相似文献   

9.
Ultrasound contrast agents (UCAs) are used in a clinical setting to enhance the backscattered signal from the blood pool to estimate perfusion and blood flow. The UCAs consist of encapsulated microbubbles, measuring 1-10 /spl mu/m in diameter. Acoustic characterization of UCAs is generally carried out from an ensemble of bubbles. The measured signal is a complicated summation of all signals from the individual microbubbles. Hence, characterization of a single bubble from acoustic measurements is complex. In this study, 583 optical observations of freely flowing, oscillating, individual microbubbles from an experimental UCA were analyzed. The excursions during ultrasound exposure were observed through a microscope. Images were recorded with a high frame rate camera operating at 3 MHz. Microbubbles on these images were measured offline, and maximal excursions were determined. A technique is described to determine the diameters of the bubbles observed. We compared the maximal excursions of microbubbles of the same initial size in an ultrasound field with a 500 kHz center frequency at acoustic amplitudes ranging from 0.06 MPa to 0.85 MPa. It was concluded that maximal excursions of identical bubbles can differ by 150% at low acoustic pressures (mechanical index or MI<0.2). At a high acoustic pressure (MI=1.2) an image sequence was recorded on which a bubble collapsed, but an apparently identical bubble survived.  相似文献   

10.
It has been shown that nonlinear scattering can be stimulated from microbubble contrast agents at high-transmit frequencies (14-32 MHz). This work was extended to demonstrate the feasibility of nonlinear contrast imaging through modifications of existing ultrasound biomicroscopy linear B-scan imaging instrumentation. In this study, we describe the development and evaluation of prototype coherent flow imaging instrumentation for nonlinear microbubble imaging using transmit frequencies from 10 to 50 MHz. Phantom validation experiments were conducted to demonstrate color and power flow imaging using nonlinear 10 MHz (subharmonic) scattering induced by a 20 MHz transmit frequency. In vivo flow imaging of a rabbit ear microvessel was successfully performed. This work indicates the feasibility of performing flow imaging at high frequencies using nonlinear scattering from microbubbles.  相似文献   

11.
Optical and acoustical interrogation of submicron contrast agents   总被引:4,自引:0,他引:4  
Unlike conventional ultrasound contrast agents with a diameter of several microns, in this paper we explore the use of submicron contrast agents for the detection and localization of lymph nodes. The submicron agents are gas-filled, double-walled microspheres that rupture when exposed to ultrasound energy at megahertz frequencies. In this study, three experimental systems are combined with model predictions to assist in understanding the response of these unique agents to a range of signal transmission parameters. Optical experimental results for each agent delineate the relative expansion as a function of acoustical peak negative pressure, pulse length, and center frequency. The optical images demonstrate an order of magnitude expansion in radius during the pulse rarefaction, in which the expansion magnitude is dependent on the transmitted pressure and frequency. Simulations using a modified Rayleigh-Plesset model predict an increasing relative expansion for the microbubbles (initial bubble radius ranging from 0.3-1.3 /spl mu/m) with increasing pressure and decreasing initial radius. Acoustically recorded frequency spectra reveal the presence of harmonics for a range of transmitted pulses. In addition, in-vivo results from a normal canine model demonstrate marked contrast enhancement of first order lymph nodes. We hope to offer an alternative to present intra-operative procedures for sentinel node detection.  相似文献   

12.
Pulse-inversion-based fundamental imaging for contrast detection   总被引:2,自引:0,他引:2  
Pulse-inversion-based fundamental imaging was experimentally investigated for the enhancement of contrast detection. The pulse-inversion technique involves two firings with inverted waveforms. When the returning echoes from the two firings are summed, the residue signal is limited to even-order harmonics for tissue. However, when the returning echoes are from microbubbles, the fundamental signal is not completely cancelled because the reaction of the bubbles under compression is different from that under rarefaction. Thus, with the application of pulse-inversion technique, the fundamental signal can be used to enhance the contrast-to-tissue ratio. In this paper, B-mode, pulse-inversion-based fundamental images were constructed with various transmit waveforms. Motion artifacts also were studied. The results indicate that the contrast-to-tissue ratio was significantly enhanced compared to that obtained using either conventional, fundamental imaging or second-harmonic imaging. Longer transmit pulses resulted in a better signal-to-noise ratio, but did not noticeably affect the nonlinear response of the bubbles. In addition, the optimal ratio of the magnitude of the positive pulse to that of the negative pulse was unity, in terms of avoiding the uncancelled, third-order response in the fundamental frequency range. It also was found that the pulse-inversion fundamental technique is highly sensitive to tissue motion because the fundamental tissue signal is not cancelled when motion is present.  相似文献   

13.
We present a technique that uses Golay phase encoding, pulse inversion, and amplitude modulation (GPIAM) for microbubble contrast agent imaging with ultrasound. This technique improves the contrast-to-tissue ratio (CTR) by increasing the time-bandwidth product of the insonating waveforms. A nonlinear pulse compression algorithm is used to compress the signal energy upon receive. A 6.5-dB improvement in CTR was observed using an 8-chip GPIAM sequence compared to a conventional pulse-inversion amplitude-modulation sequence. The CTR improvement comes at the cost of a reduction in frame rate: GPIAM coding uses four input pulses whereas most contrast imaging sequences require two or three pulses. Our results showed that the microbubble response can be phase encoded and subsequently compressed using a nonlinear matched-filtering algorithm, in order to enhance the signal from the contrast agent, while maintaining resolution and suppressing the tissue signal.  相似文献   

14.
In order to improve the sensitivity of ultrasound imaging, the contrast agents, a powerful non-invasive and real-time medical imaging technique, are used. However, air or N2 or perfluorocarbon only encapsulated microbubbles which are currently used have lower efficiency and short imaging time. So the novel contrast agents with a higher efficiency are required. To achieve this objective, the strategy that we have explored involves the use of superparamagnetic iron oxide (SPIO) Fe3O4 nanoparticles multilayer emulsion microbubbles. This multilayer structure consists of three layers. The core is poly-d, l-lactide (PLA) encapsulated N2 nanobubble with the SPIO nanoparticles forming oil-in-water (W/O) layer. The outermost is water-in-oil-in-water ((W/O)/W) emulsion layer with PVA solution. Herein we describe the synthesis and characterization of ultrasound imaging microstructure with an overall diameter of around 2μm-8μm. On the one hand, the stable gas encapsulated microstructure can provide a high scattering intensity resulting in high echogenicity, On the other hand, SPIO nanoparticles have shown the potential of high-resolution sonography. So the multiple emulsion microbubbles with SPIO can have double action to enhance the ultrasound imaging. Besides, because SPIO can also serve as magnetic resonance imaging (MRI) contrast agents, such microstructure may be useful for multimodality imaging studies in ultrasound imaging and MRI.  相似文献   

15.
Current harmonic imaging scanners transmit a narrowband signal that limits spatial resolution in order to differentiate the echoes from tissue from the echoes from microbubbles. Because spatial resolution is particularly important in applications, including mapping vessel density in tumors, we explore the use of wideband signals in contrast imaging. It is first demonstrated that microspheres can be destroyed using one or two pulses of ultrasound. Thus, temporal signal processing strategies that use the change in the echo over time can be used to differentiate echoes from bubbles and echoes from tissue. Echo parameters, including intensity and spectral shape for narrowband and wideband transmission, are then evaluated. Through these experiments, the echo intensity received from bubbles after wideband transmission is shown to be at least as large as that for narrowband transmission, and can be larger. In each case, the echo intensity increases in a nonlinear fashion in comparison with the transmitted signal intensity. Although the echo intensity at harmonic multiples of the transmitted wave center frequency can be larger for narrowband insonation, echoes received after wideband insonation demonstrate a broadband spectrum with significant amplitude over a very wide range of frequencies.  相似文献   

16.
Previous studies have revealed that hard-shelled submicron contrast agents exhibit large relative expansions and strong acoustical echoes that can be observed experimentally, and predicted by theoretical simulations. In this paper, we study harmonic imaging and pulse-pair imaging techniques designed to assist in the differentiation of these contrast agents from tissue. For harmonic imaging, we apply a high-sensitivity, narrowband strategy that differentiates the microbubble from tissue based on the generation of strong harmonic echoes. For pulse-pair imaging, we apply high spatial resolution, wideband strategies using phase inversion, which relies on the frequency differences observed in response to phase-inverted pulses, and signal subtraction, which takes advantage of the amplitude differences in response to identical pulses. The bubble-to-phantom signal amplitude ratio in the absence of motion approaches 20 dB using phase inversion and 30 dB using signal subtraction; both techniques are robust for up to 50 microm of simulated motion. With the experience gained in these studies, we hope to advance the development of multi-pulse or shaped-pulse techniques that are optimized for specific clinical applications.  相似文献   

17.
Micron- to nanometer-sized ultrasound agents, like encapsulated microbubbles and echogenic liposomes, are being developed for diagnostic imaging and ultrasound mediated drug/gene delivery. This review provides an overview of the current state of the art of the mathematical models of the acoustic behavior of ultrasound contrast microbubbles. We also present a review of the in vitro experimental characterization of the acoustic properties of microbubble based contrast agents undertaken in our laboratory. The hierarchical two-pronged approach of modeling contrast agents we developed is demonstrated for a lipid coated (Sonazoid $^\mathrm{TM})$ and a polymer shelled (poly D-L-lactic acid) contrast microbubbles. The acoustic and drug release properties of the newly developed echogenic liposomes are discussed for their use as simultaneous imaging and drug/gene delivery agents. Although echogenicity is conclusively demonstrated in experiments, its physical mechanisms remain uncertain. Addressing questions raised here will accelerate further development and eventual clinical approval of these novel technologies.  相似文献   

18.
微泡由于其特殊的结构,广泛地应用于食品、化妆品、医学等领域.尤其是在医学超声造影方面的应用,开创了无创超声医学的新领域.而医学造影用微泡材料的制备是一个复杂、有相当难度的过程.微胶囊技术的引入大大加快了微泡造影荆制备方法的发展.对近年来国内外微泡造影剂的各种制备方法及其优缺点进行了介绍.指出采用化学方法能得到更加个性化的声学造影剂,并使其具有成像和靶向治疗的双重功效.  相似文献   

19.
Golay-encoded excitation in combination with the third harmonic (3f?) transmit phasing is examined for both signal-to-noise ratio (SNR) and contrast-to-tissue ratio (CTR) improvements in harmonic imaging of contrast microbubbles. To produce the cancellation pair of tissue harmonic signal in 3f? transmit phasing, the phase of the bit waveform is properly designed for both the fundamental and the 3f? transmit signals to provide the Golay encoding of the received harmonic responses. Results indicate that the proposed Golay excitation can effectively suppress the tissue harmonic amplitude to increase CTR. Meanwhile, the SNR of the contrast harmonic signal also improves because of the elongated waveform of Golay excitation. Nevertheless, the generation of marked range side-lobes of the bubble region would degrade the achievable SNR improvement and the image contrast, especially when the bit of Golay excitation increases. The range side-lobes could result from the nonlinear resonance of the microbubbles that interferes with the phase modulation of the Golay encoding.  相似文献   

20.
Vibro-acoustography is an imaging method that uses the radiation force of two interfering ultrasound beams of slightly different frequency to probe an object. An image is made using the acoustic emission resulted from the object vibration at the difference frequency. In this paper, the feasibility of imaging objects at twice the difference frequency (harmonic acoustic emission) is studied. Several possible origins of harmonic acoustic emission are explored. As an example, it is shown that microbubbles close to resonance can produce significant harmonic acoustic emission due to its high nonlinearity. Experiments demonstrate that, compared to the fundamental acoustic emission, harmonic acoustic emission greatly improves the contrast between microbubbles and other objects in vibro-acoustography (an improvement of 17-23 dB in these experiments). Applications of this technique include imaging the nonlinearity of the object and selective detection of microbubbles for perfusion imaging. The impact of microbubble destruction during the imaging process also is discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号