首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
Estimating Motion From MRI Data   总被引:2,自引:0,他引:2  
Magnetic resonance imaging (MRI) is an ideal imaging modality to measure blood flow and tissue motion. It provides excellent contrast between soft tissues, and images can be acquired at positions and orientations freely defined by the user. From a temporal sequence of MR images, boundaries and edges of tissues can be tracked by image processing techniques. Additionally, MRI permits the source of the image signal to be manipulated. For example, temporary magnetic tags displaying a pattern of variable brightness may be placed in the object using MR saturation techniques, giving the user a known pattern to detect for motion tracking. The MRI signal is a modulated complex quantity, being derived from a rotating magnetic field in the form of an induced current. Well-defined patterns can also be introduced into the phase of the magnetization, and could be thought of as generalized tags. If the phase of each pixel is preserved during image reconstruction, relative phase shifts can be used to directly encode displacement, velocity and acceleration. New methods for modeling motion fields from MRI have now found application in cardiovascular and other soft tissue imaging. In this review, we shall describe the methods used for encoding, imaging, and modeling motion fields with MRI.  相似文献   

2.
Magnetic resonance imaging (MRI) allows a physician to obtain images of internal organs noninvasively. Imaging a moving organ such as the heart requires a trigger so that successive scans can be synchronized. In the case of cardiac imaging this trigger is the electrocardiogram (ECG). When a patient is in an MRI scanner he/she is subjected to both static and dynamic magnetic fields which can cause interference In the ECG. The dynamic fields consist of 8- to 64-MHz radio frequency (RF) pulses and low-frequency magnetic gradient pulses with frequency components below 100 Hz. Conventional bandpass filters are only moderately effective because the passband allows magnetic gradient-induced interference to be superimposed on the ECG, causing distortion of the signal. This paper describes a technique which can be used to remove induced MRI gradient interference from an ECG recorded on a patient inside the bore of a MRI scanner. Induced signal from an external loop is subtracted from the ECG to minimize the low-frequency interference. The gradient induced low-frequency interference was reduced to approximately 20% of its magnitude when using conventional ECG amplifiers  相似文献   

3.
This study proposes a new method to generate positive contrast in magnetic resonance imaging (MRI) using superparamagnetic contrast agents. Superparamagnetic nanostructures consisting of octahedron manganese ferrite nanoparticles embedded in spherical nanogels are fabricated using a bottom‐up approach. The composite nanoparticles are strongly magnetized in an external magnetic field and produce a unique NMR frequency shift in water protons, which can be demonstrated in MR spectroscopy and imaging to be different from the bulk pool. Moreover, the particles exhibit excellent colloidal stability in aqueous media and good cell biocompatibility. Hence, these particles are potentially useful as biomarkers by taking advantage of the positive contrast effects produced in MRI.  相似文献   

4.
This paper addresses one of the major problems in interventional magnetic resonance imaging (MRI): the visualization of interventional devices. For visualization locally induced magnetic fields are used, which disturb the homogeneity of the main magnetic field of the MR scanner. This results in signal loss in the vicinity of the device due to intravoxel dephasing, and leads to a disturbance of the phase image. The local fields are established by a low current in a closed copper loop along the device. This method is introduced as a means for catheter visualization. The basic theory behind this method is presented. Simulations are performed to determine the effect of intravoxel dephasing, without interfering effects like susceptibility or radio-frequency artifacts. Scanned and simulated data is used to verify the theoretical consideration. Different configurations of wire loops are discussed and two types of catheter visualization scans are proposed. Results from a pig study show that this methods holds promise for intravascular interventions under MRI guidance  相似文献   

5.
The accuracy of q-space measurements was evaluated at a 3.0-T clinical magnetic resonance imaging (MRI) scanner, as compared with a 4.7-T nuclear magnetic resonance (NMR) spectrometer. Measurements were performed using a stimulated-echo pulse-sequence on n-decane as well as on polyethylene glycol (PEG) mixed with different concentrations of water, in order to obtain bi-exponential signal decay curves. The diffusion coefficients as well as the modelled diffusional kurtosis K(fit) were obtained from the signal decay curve, while the full-width at half-maximum (FWHM) and the diffusional kurtosis K were obtained from the displacement distribution. Simulations of restricted diffusion, under conditions similar to those obtainable with a clinical MRI scanner, were carried out assuming various degrees of violation of the short gradient pulse (SGP) condition and of the long diffusion time limit. The results indicated that an MRI system can not be used for quantification of structural sizes less than about 10 microm by means of FWHM since the parameter underestimates the confinements due to violation of the SGP condition. However, FWHM can still be used as an important contrast parameter. The obtained kurtosis values were lower than expected from theory and the results showed that care must be taken when interpreting a kurtosis estimate deviating from zero.  相似文献   

6.
This paper is motivated by the analysis of serial structural magnetic resonance imaging (MRI) data of the brain to map patterns of local tissue volume loss or gain over time, using registration-based deformation tensor morphometry. Specifically, we address the important confound of local tissue contrast changes which can be induced by neurodegenerative or neurodevelopmental processes. These not only modify apparent tissue volume, but also modify tissue integrity and its resulting MRI contrast parameters. In order to address this confound we derive an approach to the voxel-wise optimization of regional mutual information (RMI) and use this to drive a viscous fluid deformation model between images in a symmetric registration process. A quantitative evaluation of the method when compared to earlier approaches is included using both synthetic data and clinical imaging data. Results show a significant reduction in errors when tissue contrast changes locally between acquisitions. Finally, examples of applying the technique to map different patterns of atrophy rate in different neurodegenerative conditions is included.  相似文献   

7.
月球探测是我国太空探测的重要任务,月球内部结构探测是其中一个重要的研究方向.以瞬变电磁法(transient electromagnetic methods,TEM)为基础,提出了一种基于太阳风暴的月球内部结构探测方法.该方法利用太阳风暴产生的磁场跃变作为使月球内部产生极化的探测源,在太阳风暴作用下,月球内部介质极化产...  相似文献   

8.
Narrowband Magnetic Particle Imaging   总被引:1,自引:0,他引:1  
The magnetic particle imaging (MPI) method directly images the magnetization of super-paramagnetic iron oxide (SPIO) nanoparticles, which are contrast agents commonly used in magnetic resonance imaging (MRI). MPI, as originally envisioned, requires a high-bandwidth receiver coil and preamplifier, which are difficult to optimally noise match. This paper introduces Narrowband MPI, which dramatically reduces bandwidth requirements and increases the signal-to-noise ratio for a fixed specific absorption rate. We employ a two-tone excitation (called intermodulation) that can be tailored for a high-Q, narrowband receiver coil. We then demonstrate a new MPI instrument capable of full 3-D tomographic imaging of SPIO particles by imaging acrylic and tissue phantoms.   相似文献   

9.
Electric currents are applied to body in numerous applications in medicine such as electrical impedance tomography, cardiac defibrillation, electrocautery, and physiotherapy. If the magnetic field within a region is measured, the currents generating these fields can be calculated using the curl operator. In this study, magnetic fields generated within a phantom by currents passing through an external wire is measured using a magnetic resonance imaging (MRI) system. A pulse sequence that is originally designed for mapping static magnetic field inhomogeneity is adapted. AC current in the form of a burst sine wave is applied synchronously with the pulse sequence. The frequency of the applied current is in the audio range with an amplitude of 175-mA rms. It is shown that each voxel value of sequential images obtained by the proposed pulse sequence is modulated similar to a single-tone broadband frequency modulated (FM) waveform with the AC magnetic field strength determining the modulation index. An algorithm is developed to calculate the AC magnetic field intensity at each voxel using the frequency spectrum of the voxel signal. Experimental results show that the proposed algorithm can be used to calculate AC magnetic field distribution within a conducting sample that is placed in an MRI system  相似文献   

10.
Prior theoretical studies indicate that the negative spatial derivative of the electric field induced by magnetic stimulation may be one of the main factors contributing to depolarization of the nerve fiber. This paper studies this parameter for peripheral nerve stimulation (PNS) induced by time-varying gradient fields during MRI scans. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic human, full-body model. Whole-body cylindrical and planar gradient sets in MRI systems and various input signals have been explored. The spatial distributions of the induced electric field and their gradients are calculated and attempts are made to correlate these areas with reported experimental stimulation data. The induced electrical field pattern is similar for both the planar coils and cylindrical coils. This study provides some insight into the spatial characteristics of the induced field gradients for PNS in MRI, which may be used to further evaluate the sites where magnetic stimulation is likely to occur and to optimize gradient coil design.  相似文献   

11.
A significantly improved material is developed for application to chemiresistors, which are resistance‐based sensors for volatile organic compounds. This material is a polymer composite containing Au‐coated magnetic particles organized into electrically conducting pathways by magnetic fields. This improved material overcomes the various problems inherent to conventional carbon‐black chemiresistors, while achieving an unprecedented response magnitude. When exposed to chemical vapors, the polymer swells only slightly, yet this is amplified into large, reversible resistance changes, as much as (1 × 1011)% at a swelling of only 1.5%. These conductor–insulator transitions occur over such a narrow range of analyte vapor concentration that these devices can be described as chemical switches. The sensitivity and response range of these sensors can be tailored over a wide range by controlling the stress within the composite, including through the application of a magnetic field. Such tailorable sensors can be used to create sensor arrays that can accurately determine analyte concentration over a broad concentration range, or can be used to create logic circuits that signal a particular chemical environment.  相似文献   

12.
Magnetic susceptibility is an important physical property of tissues, and can be used as a contrast mechanism in magnetic resonance imaging (MRI). Recently, targeting contrast agents by conjugation with signaling molecules and labeling stem cells with contrast agents have become feasible. These contrast agents are strongly paramagnetic, and the ability to quantify magnetic susceptibility could allow accurate measurement of signaling and cell localization. Presented here is a technique to estimate arbitrary magnetic susceptibility distributions by solving an ill-posed inversion problem from field maps obtained in an MRI scanner. Two regularization strategies are considered: conventional Tikhonov regularization and a sparsity promoting nonlinear regularization using the $ell_{1}$ norm. Proof of concept is demonstrated using numerical simulations, phantoms, and in a stroke model in a rat. Initial experience indicates that the nonlinear regularization better suppresses noise and streaking artifacts common in susceptibility estimation.   相似文献   

13.
In this paper, a highly innovative concept of using ultrathin iron oxide nanowhiskers as a positive (T1) contrast agent for magnetic resonance imaging (MRI) is demonstrated. Iron oxide nanowhiskers with dimensions of approximately 2 nm × 20 nm are synthesized by heating an iron oleate/oleylamine complex under 150 °C. These nanostructures have very high surface‐to‐volume ratios, leading to strong paramagnetic signal, a property suitable for T1 contrast in MRI. The positive contrast enhancement of these nanowhiskers is demonstrated in vitro and in vivo in a rat model. Successful development of this technology has substantial commercial value in biomedical imaging, potentially leading to the advancement of human healthcare technologies.  相似文献   

14.
Internal delamination damage is detected in fiber reinforced polymer composite materials containing active functionality. Damage‐triggered magnetization of the delaminated zone is accomplished using a vascular system to deliver fluids that precipitate magnetic particles upon mixing. Multiple modes of detection are used to sense the presence of this magnetic material. Visual detection is accomplished by the high contrast between damaged and undamaged areas provided by the biomimetic “bruise” formed by the magnetic particles. Magnetic scanning is also used to detect the particles, even if obscured by paint or by opaque reinforcement, such as carbon fiber. Additionally, thermal detection is accomplished by inductively heating the magnetic particles and sensing the temperature differential with an infrared camera. The effectiveness of each detection mode is discussed and compared to industry standard C‐scan to assess accuracy. Using the damage area measured with C‐scan as the benchmark, visual detection measures the damage area with 76% accuracy, and magnetic detection measures the damage area with 91% accuracy. Thermal detection accuracy is time‐dependent as expected. All detection modes consistently detect the presence of damage. The multifunctionality of this material can tailor damage detection techniques for the application and provide a parallel system to augment and potentially enhance self‐healing.  相似文献   

15.
Ultrasound is the most commonly used clinical imaging modality. However, in applications requiring cell‐labeling, the large size and short active lifetime of ultrasound contrast agents limit their longitudinal use. Here, 100 nm radius, clinically applicable, polymeric nanoparticles containing a liquid perfluorocarbon, which enhance ultrasound contrast during repeated ultrasound imaging over the course of at least 48 h, are described. The perfluorocarbon enables monitoring the nanoparticles with quantitative 19F magnetic resonance imaging, making these particles effective multimodal imaging agents. Unlike typical core–shell perfluorocarbon‐based ultrasound contrast agents, these nanoparticles have an atypical fractal internal structure. The nonvaporizing highly hydrophobic perfluorocarbon forms multiple cores within the polymeric matrix and is, surprisingly, hydrated with water, as determined from small‐angle neutron scattering and nuclear magnetic resonance spectroscopy. Finally, the nanoparticles are used to image therapeutic dendritic cells with ultrasound in vivo, as well as with 19F MRI and fluorescence imaging, demonstrating their potential for long‐term in vivo multimodal imaging.  相似文献   

16.
MRI artifact cancellation due to rigid motion in the imaging plane   总被引:7,自引:0,他引:7  
A post-processing technique has been developed to suppress the magnetic resonance imaging (MRI) artifact arising from object planar rigid motion. In two-dimensional Fourier transform (2-DFT) MRI, rotational and translational motions of the target during magnetic resonance magnetic resonance (MR) scan respectively impose nonuniform sampling and a phase error an the collected MRI signal. The artifact correction method introduced considers the following three conditions: (1) for planar rigid motion with known parameters, a reconstruction algorithm based on bilinear interpolation and the super-position method is employed to remove the MRI artifact, (2) for planar rigid motion with known rotation angle and unknown translational motion (including an unknown rotation center), first, a super-position bilinear interpolation algorithm is used to eliminate artifact due to rotation about the center of the imaging plane, following which a phase correction algorithm is applied to reduce the remaining phase error of the MRI signal, and (3) to estimate unknown parameters of a rigid motion, a minimum energy method is proposed which utilizes the fact that planar rigid motion increases the measured energy of an ideal MR image outside the boundary of the imaging object; by using this property all unknown parameters of a typical rigid motion are accurately estimated in the presence of noise. To confirm the feasibility of employing the proposed method in a clinical setting, the technique was used to reduce unknown rigid motion artifact arising from the head movements of two volunteers.  相似文献   

17.
Magnetic resonance imaging (MRI) has been established as a reliable and safe imaging method for the human body. However, electric conductors, such as cables situated near or in the human body, should be avoided because induced currents in the cables can cause hazardous heating in the surrounding tissue. In this paper, a new principle for the design of a transmission line is introduced and demonstrated, which is capable of avoiding dangerous heating of cables. The principle is based on transformers placed along the line, splitting the long line into several short not resonant and thus safe sections. A transformer design is introduced along with the theoretical aspects for both the avoidance of the undesired induced currents and the reduction of signal attenuation. Furthermore, the design fulfills the geometrical requirements of the side lumen of a standard catheter. Matching networks, whose elements are determined by power matching, are used to reduce signal attenuation by the transformers. A prototype was built to validate both theory and the simulations. As demonstrated in this work, it is possible to build safe transmission lines for MRI, making applications such as active catheter tracking possible. We expect that even new applications, such as safe intravascular imaging will be possible in a safe manner in the future.  相似文献   

18.
Contrast-enhanced magnetic resonance imaging (MRI) is useful to study the infiltration of cells in vivo. This research adopts ultrasmall superparamagnetic iron oxide (USPIO) particles as contrast agents. USPIO particles administered intravenously can be endocytosed by circulating immune cells, in particular, macrophages. Hence, macrophages are labeled with USPIO particles. When a transplanted heart undergoes rejection, immune cells will infiltrate the allograft. Imaged by T(2)(*)-weighted MRI, USPIO-labeled macrophages display dark pixel intensities. Detecting these labeled cells in the image facilitates the identification of acute heart rejection. This paper develops a classifier to detect the presence of USPIO-labeled macrophages in the myocardium in the framework of spectral graph theory. First, we describe a USPIO-enhanced heart image with a graph. Classification becomes equivalent to partitioning the graph into two disjoint subgraphs. We use the Cheeger constant of the graph as an objective functional to derive the classifier. We represent the classifier as a linear combination of basis functions given from the spectral analysis of the graph Laplacian. Minimization of the Cheeger constant based functional leads to the optimal classifier. Experimental results and comparisons with other methods suggest the feasibility of our approach to study the rejection of hearts imaged by USPIO-enhanced MRI.  相似文献   

19.
The goal of this study was to propose a general numerical analysis methodology to evaluate the magnetic resonance imaging (MRI)-safety of active implants. Numerical models based on the finite element (FE) technique were used to estimate if the normal operation of an active device was altered during MRI imaging. An active implanted pump was chosen to illustrate the method. A set of controlled experiments were proposed and performed to validate the numerical model. The calculated induced voltages in the important electronic components of the device showed dependence with the MRI field strength. For the MRI radiofrequency fields, significant induced voltages of up to 20 V were calculated for a 0.3T field-strength MRI. For the 1.5 and 3.0OT MRIs, the calculated voltages were insignificant. On the other hand, induced voltages up to 11 V were calculated in the critical electronic components for the 3.0T MRI due to the gradient fields. Values obtained in this work reflect to the worst case situation which is virtually impossible to achieve in normal scanning situations. Since the calculated voltages may be removed by appropriate protection circuits, no critical problems affecting the normal operation of the pump were identified. This study showed that the proposed methodology helps the identification of the possible incompatibilities between active implants and MR imaging, and can be used to aid the design of critical electronic systems to ensure MRI-safety.  相似文献   

20.
This paper evaluates the use of electrorheological fluids (ERFs) within a magnetic resonance imaging (MRI) environment. ERF is a semiactive variable impedance material, which could be used as an alternative type of resistive force/torque generation or in combination with other actuators as a damper/clutch to modulate the output force/torque of the actuator. In this paper, an ERF damper/brake is introduced and its magnetic resonance (MR) compatibility is examined at a 3-T MR imaging environment by measuring the output performance of the damper and the SNR of the MRI images. The experimental results showed that damper's resistive force generation while positioned within the MRI is almost the same as that in normal operation. The signal-to-noise investigation was performed both with a phantom and human. The results indicated that the ERF damper did not affect the MRI images when it was operated over 30 cm away from the MRI's RF coil. We hope that the synthesis and tables presented in this paper can facilitate the choice of ERF brake actuation principle to various applications in an MR environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号