共查询到20条相似文献,搜索用时 0 毫秒
1.
随着各种敏感设备在工业中的广泛应用,电能质量尤其是电压跌落问题越来越引起人们关注。静止型无功补偿器SVC具有快速平滑的调节无功输出的特点,能够很好地对电压跌落进行抑制。从理论上分析了SVC能有效地抑制电压跌落的原理,推导了SVC补偿容量的计算方法,并且根据实际情况建立了SVC改善电压质量的电磁暂态仿真模型,针对用户端不同的电压跌落深度,SVC的不同安装地点进行SVC补偿的仿真,对仿真结果进行对比分析。 相似文献
2.
静止无功补偿器对电压稳定性的影响 总被引:30,自引:3,他引:30
本文对静止无功补偿器(SVC)的控制建立计算机仿真模型,并在三机十一母线系统中进行负荷微增的仿真,通过仿真的结果,我们可以看出,在到达其上限之前,对系统的电压稳定性有一定改善,并比较了不同功率因数的负荷微增下的SVC对电压稳定的影响。 相似文献
3.
4.
Shoji Kawasaki Naohiro Kurokawa Hisao Taoka Yuya Nakashima 《Electrical Engineering in Japan》2016,194(1):1-9
In recent years, the number of renewable energy sources (RESs) such as photovoltaic generation systems and wind power generation systems connected to the grid has been increasing as a way of reducing negative effects on the environment. The outputs of these RESs vary rapidly because of the influence of the weather and the conditions of the location. Therefore, there are concerns that the point voltages in a distribution system may vary drastically and that the voltages may deviate from the appropriate voltage range as a result of the influence of the RES connected to the distribution system or to the diversification of loads. Furthermore, there are concerns about adverse effects on electric power quality, such as voltage imbalances and harmonics. In this paper, we propose a cooperative voltage control method for a distribution system using system voltage control equipment in order to reduce the capacity of the static synchronous compensator. Numerical calculations were performed in order to verify the validity of the proposed method. 相似文献
5.
针对华北地区某大型坑口电厂(A电厂)串联补偿送出系统次同步谐振(subsynchronousresonance,SSR)引发发电机组轴系扭振的问题,采用基于电力系统计算机辅助设计和电磁暂态模拟程序软件(powersystemcom-puteraideddesignandelectricmagnetictransientinDCsystem,PSCAD/EMTDC)的时域仿真与频域仿真分析相结合的方法,通过大量的仿真计算,对静止无功补偿器(staticvarcompensator,SvC)抑制SSR的工作原理、控制策略及其影响因素等进行了系统的研究和验证。仿真结果与实际工程应用结果均表明,SVC能有效抑制SsR的发生。该方法可解决南方电网系统内交流串联补偿输电工程中的SSR问题。 相似文献
6.
7.
本文中作者介绍了直流电弧炉变压器的基本原理及设计特点,并针对一台HZS-1250/10直流电弧炉变压器的设计过程进行了详细介绍。 相似文献
8.
9.
大容量SVC对变压器差动保护的影响及解决措施 总被引:1,自引:0,他引:1
大容量静止无功补偿器(SVC)已在实际工程中获得应用。理论分析和数字仿真表明,在变压器低压侧发生故障时,SVC设备会向故障点注入大量的3次、5次等奇次谐波电流,含量显著且衰减缓慢。现有变压器差动保护为防止在区外故障电流互感器(TA)饱和、励磁涌流及过激磁等情况下产生的差动电流造成保护误动,通常采用谐波制动方法。大容量SVC设备产生的谐波电流可能造成TA饱和判别元件误判,从而引起差动保护动作速度变慢甚至拒动。为此,应避免在低压侧TA饱和判据中采用3次谐波而改用2次谐波。通过实际工程的RTDS试验数据验证了理论分析的有效性。 相似文献
10.
11.
纯电压型SVC非线性控制器的研究 总被引:2,自引:0,他引:2
应用直接反馈线化理论设计了一种纯电压型SVC非线性控制器。其突出优点是:鲁棒性好,动态电压支撑能力强,但是SVC定电压控制不能提供系统阻尼。 相似文献
12.
A Cooperative Control Algorithm for Multiple SVRs Using Correlation of Measurement Data of Distribution Line 下载免费PDF全文
MASAHIRO WATANABE REIJI TAKAHASHI KATSUHIRO MATSUDA TOSHIYUKI SETO 《Electrical Engineering in Japan》2018,202(1):3-10
In this paper, a cooperative control algorithm for multiple step voltage regulator (SVR) using correlation of measurement data of distribution line is proposed. Conventionally, the control time constant of a SVR placed on the feeder end side was set slower than a SVR placed on the substation side. The unnecessary tap movement of SVR was reduced by this setting. In this case, on the condition that “the photovoltaic power generation output of the feeder end fluctuates” and “only SVR of the end side works”, it is a problem that control of SVR becomes slow. By the proposed method, the SVR settled in end side of a feeder can change its tap rapidly only if the SVR settled in sending side of a feeder will not change its tap by using proposed method. The features of the method are followings: (1) to estimate tap change possibility of the sending side SVR using correlation model of both of the SVR, (2) only use local measurement data of the SVRs for tap change control. By the proposed method, unnecessary tap change operation and lag of tap control are reduced without communication networks. 相似文献
13.
14.
在考虑发电机组及其调节系统、负荷、SVC和TCSC动态过程的情况下,列出了系统的线性化微分方程和代数方程。得出了消去代数方程后的系统线性化微分方程组系数矩阵不出现正实特征值的必要条件为:两种潮流雅可比矩阵的行列式应具有相同的符号,这一条件可以作为小干扰电压稳定性的判据。从理论上来说。它的结果与特征值分析方法一致,而所需要的计算工作量却大大减少,并避免了QR法计算特征值可能产生的数值问题。文中给出了113机542节点西北电网的计算结果。 相似文献
15.
16.
鞍山红一变SVC国产化示范工程介绍 总被引:3,自引:1,他引:3
鞍山红一变高压静止无功补偿装置(static var compensator,SVC)工程是中国第一个电网SVC国产化示范工程。SVC主要用来替代变电站原有调相机,投运后不仅能为鞍山电网提供快速动态无功电源,还能提高电网稳定性和电能质量。文章阐述了该工程的设计、运行、应用方面的主要问题,介绍了SVC容量的确定、系统主接线、技术参数,论述了装设SVC后的谐波分析结果和电压改善仿真结果以及SVC装置投运后对电网电压和谐波的实际改善效果,分析了SVC所带来的经济效益、对系统潮流分布的改善,鞍山受电断面稳定水平的提高。 相似文献
17.
18.
Keiichi Shimizu Takamu Genji Chikashi Nakazawa Yosuke Nakanishi 《Electrical Engineering in Japan》2007,160(3):1-11
This paper discusses the stability and an interactive phenomenon of one SVC, two or more sets of SVC, an SVC and an SVR in distribution systems. In particular, we focus on the saddle‐node bifurcation and Hopf bifurcation points. The two local bifurcation points show a boundary of a stable domain. © 2007 Wiley Periodicals, Inc. Electr Eng Jpn, 160(3): 1–11, 2007; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/eej.20333 相似文献
19.
本文主要介绍了电压互感器在实际使用过程中易出的问题和采取的保护措施,重点介绍了几种常见的故障类型和解决方法,并通过实例,对故障的处理方法进行了分析. 相似文献
20.
随着电力电子技术、微处理技术和控制技术的发展,柔性交流输电系统FACTS(Flexible AC Transmission System)的出现,为电力系统急待解决问题提供了新的手段或策略。静止无功补偿器(SVC)作为FACTS家族的成员之一,对电力系统性能的改善也已取得了可喜的成绩。因此,从静止无功补偿器提高稳态输送容量、提高暂态稳定性、增强系统阻尼抑制低频振荡、缓解次同步谐振、预防电压不稳定或控制电压的波动、改善直流输电系统的性能等六个方面进行综述。 相似文献