首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We demonstrate the possibility to increase substantially the number of simultaneously detected fluorophores by utilizing both spectral and lifetime information. Using a two-detector confocal scanning laser microscope, experiments confirm that four different fluorophores can be detected with good channel separation. The signal-to-noise ratio (SNR) of the recorded images is investigated both theoretically and experimentally. It is found that in order to obtain a high SNR fluorophore lifetimes should differ by approximately an order of magnitude.  相似文献   

2.
The improved resolution and sectioning capability of a confocal microscope make it an ideal instrument for extracting three-dimensional information especially from extended biological specimens. The imaging properties, also with finite detection pinholes are considered and a number of biological applications demonstrated.  相似文献   

3.
In three-dimensional (3-D) fluorescence images produced by a confocal scanning laser microscope (CSLM), the contribution of the deeper layers is attenuated due to absorption and scattering of both the excitation and the fluorescence light. Because of these effects a quantitative analysis of the images is not always possible without restoration. Both scattering and absorption are governed by an exponential decay law. Using only one (space-dependent) extinction coefficient, the total attenuation process can be described. Given the extinction coefficient we calculate within a non-uniform object the relative intensity of the excitation light at its deeper layers. We also give a method to estimate the extinction coefficients which are required to restore 3-D images. An implementation of such a restoration filter is discussed and an example of a successful restoration is given.  相似文献   

4.
We investigate the performance of confocal pH imaging when using phase fluorometry and fluorophores with pH-dependent lifetimes. In these experiments, the specimen is illuminated by a laser beam, whose intensity is sinusoidally modulated. The lifetime-dependent phase shift in the fluorescent signal is detected by a lock-in amplifier, and converted into a pH value through a calibration procedure. A theoretical investigation is made of how the different system parameters will influence the results concerning sensitivity and noise. Experiments carried out with the fluorophore SNAFL-2 support these theoretical predictions. It is found that, under realistic experimental conditions, we can expect a pH change of 0.1 units to be easily detected in an 8-bit digital image. However, the pixel-to-pixel root mean square noise is often of the order of one pH unit. This comparatively high level of noise has its origin in photon quantum noise. pH measurements on living cells show a systematic deviation from expected values. This discrepancy appears to be the result of fluorophore interaction with various cell constituents, and is the subject of further investigation.  相似文献   

5.
A method for reflectance in situ hybridization (RISH) is presented. The importance of the method is demonstrated by results obtained on cytological and histological breast cancer specimens. Scattering reflectance signals from 1-nm colloidal-gold particles after RNA/RNA in situ hybridization, using digoxigenin-labelled riboprobes, were detected by confocal scanning laser microscopy. The mRNA expression of two ras-related genes, rho B and rho C, was analysed in human histological breast cancer specimens and in human breast cancer cell lines. Horizontal (x, y) and vertical (z) optical sections after three-dimensional imaging were used for visualization. A marked heterogeneity (between individual cells and between specimens) was noted for the expression of the rho B gene, both in cytological and in histological samples. On the other hand, rho C was always expressed and showed no heterogeneity. This method allows the identification of several cellular constituents in an heterogeneous tissue structure, as demonstrated by the simultaneous detection of rho B (or rho C) by reflectance and of DNA, cytokeratin and/or vimentin by fluorescence.  相似文献   

6.
We describe measurements of the point spread function (PSF) for a confocal microscope and compare them with the PSF for a conventional (wide-field) fluorescence microscope. In situ hybridization with probes to telomere and ribosomal rDNA sequences, combined with three-dimensional (3-D) microscopy, has been used to study interphase nuclei in root tissue of Pisum sativum and Vicia faba. Nearly all the telomeres in both species are located at the nuclear envelope, and are highly clustered in the Vicia tissues, suggesting specific binding interactions. rDNA labelling in P. sativum shows four brightly staining knobs, corresponding to condensed regions of the rDNA genes from the two pairs of nucleolar organizer genes in this species, arranged approximately tetrahedrally around each nucleolus. Deconvolution using the measured PSFs can be used to improve these images, revealing a fibrous substructure in the perinucleolar knobs, and a large amount of interconnecting internal structure, which we suggest represents rDNA both in the fibrillar centres and also more diffuse, widely dispersed rDNA. Finally we show that accurate conventional data coupled with deconvolution can produce 3-D reconstructions comparable to those obtainable with confocal microscopy, but that the clearest images are obtained by applying deconvolution to the confocal data.  相似文献   

7.
Correlative microscopy is a collection of procedures that rely upon two or more imaging modalities to examine the same specimen. The imaging modalities employed should each provide unique information and the combined correlative data should be more information rich than that obtained by any of the imaging methods alone. Currently the most common form of correlative microscopy combines fluorescence and electron microscopy. While much of the correlative microscopy in the literature is derived from studies of model cell culture systems we have focused, primarily, on correlative microscopy in tissue samples. The use of tissue, particularly human tissue, may add constraints not encountered in cell culture systems. Ultrathin cryosections, typically used for immunoelectron microscopy, have served as the substrate for correlative fluorescence and electron microscopic immunolocalization in our studies. In this work, we have employed the bifunctional reporter FluoroNanogold. This labeling reagent contains both a fluorochrome and a gold-cluster compound and can be imaged by sequential fluorescence and electron microscopy. This approach permits the examination of exactly the same sub-cellular structures in both fluorescence and electron microscopy with a high level of spatial resolution.  相似文献   

8.
Test systems for measuring cell viability in optical microscopy (based on colony formation ability or lysosomal integrity) were established and applied to native cells as well as to cells incubated with fluorescence markers or transfected with genes encoding for fluorescent proteins. Human glioblastoma and Chinese hamster ovary cells were irradiated by various light doses, and maximum doses where at least 90% of the cells survived were determined. These tolerable light doses were in the range between 25 J cm?2 and about 300 J cm?2 for native cells (corresponding to about 250?3000 s of solar irradiance and depending on the wavelength as well as on the mode of illumination, e.g. epi‐ or total internal reflection illumination) and decreased to values between 50 J cm?2 and less than 1 J cm?2 upon application of fluorescent markers, fluorescent proteins or photosensitizers. In high‐resolution wide field or laser scanning microscopy of single cells, typically 10?20 individual cell layers needed for reconstruction of a 3D image could be recorded with tolerable dose values. Tolerable light doses were also maintained in fluorescence microscopy of larger 3D samples, e.g. cell spheroids exposed to structured illumination, but may be exceeded in super‐resolution microscopy based on single molecule detection.  相似文献   

9.
Quantitative evaluation of the ability of bone resorption activity in live osteoclast‐like cells (OCLs) has not yet been reported on. In this study, we observed the sequential morphological change of OCLs and measured the resorbing calcium phosphate (CP) area made by OCLs alone and with the addition of elcatonin utilizing incubator facilitated video‐enhanced microscopy. OCLs, which were obtained from a coculture of ddy‐mouse osteoblastic cells and bone marrow cells, were cultured on CP‐coated quartz cover slips. The CP‐free area increased constantly in the OCLs alone, whereas it did not increase after the addition of elcatonin. This study showed that analysis of the resorbed areas under the OCL body using this method enables the sequential quantitative evaluation of the bone resorption activity and the effect of several therapeutic agents on bone resorption in vitro. Microsc. Res. Tech, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

10.
The phenomenon of resonance energy transfer first described by Theodor Förster presents the opportunity of retrieving information on molecular proximity, orientation and conformation on the nanometre scale from (living) samples with conventional fluorescence microscopes (or even macroscopic devices). During the past 10 years Förster (or fluorescence) resonance energy transfer (FRET) microscopy has been revolutionized by the vast progress in fluorescent protein and in situ fluorescent labelling technology as well as by the commercial availability of advanced quantitative microscopy instrumentation. FRET microscopy is now routinely used in modern cell biology research. This short review will guide the reader through the most established FRET microscopy techniques, their inherent strengths and limitations, potential pitfalls, and assist the reader in making an educated choice on the FRET microscopy method most suited for their specific application.  相似文献   

11.
The imaging properties of a confocal fluorescence microscope are considered on the basis of a theoretical model. The model takes into account high-aperture objectives, the polarization state of the excitation light and a finite detector pinhole. Electromagnetic diffraction theory of the field near focus as developed by Richards and Wolf is used to compute the optical properties of the model. These are shown to be dependent on the polarization of the light. With the resulting three-dimensional point spread function we have studied the imaging of point, line and plane objects as a function of their orientation with respect to the confocal plane. In addition, the effect of the pinhole size on the image formation of these objects is discussed. The results indicate the necessity to take object orientation into account during image processing activities such as segmentation or analysis.  相似文献   

12.
The effect of refractive-index mismatch, as encountered in the observation of biological specimens, on the image acquisition process in confocal fluorescence microscopy is investigated theoretically. The analysis takes the vectorial properties of light into account and is valid for high numerical apertures. Quantitative predictions on the decrease of resolution, intensity drop and shift of focus are given for practical situations. When observing with a numerical aperture of 1·3 (oil immersion) and an excitation wavelength of 514 nm the centre of the focus shifts 1·7 μm per 10 μm of axial displacement in an aqueous medium, thus yielding an image that is scaled by a factor of 1·2 in the axial direction. Furthermore, it can be expected that for a fluorescent plane 20 μm deep inside an aqueous medium the peak intensity is 40% less than for a plane which is 10 μm deep. In addition, the axial resolution is decreased by a factor of 1·4. The theory was experimentally verified for test samples with different refractive indices.  相似文献   

13.
In this study, we present a correlative microscopy workflow to combine detailed 3D fluorescence light microscopy data with ultrastructural information gained by 3D focused ion beam assisted scanning electron microscopy. The workflow is based on an optimized high pressure freezing/freeze substitution protocol that preserves good ultrastructural detail along with retaining the fluorescence signal in the resin embedded specimens. Consequently, cellular structures of interest can readily be identified and imaged by state of the art 3D confocal fluorescence microscopy and are precisely referenced with respect to an imprinted coordinate system on the surface of the resin block. This allows precise guidance of the focused ion beam assisted scanning electron microscopy and limits the volume to be imaged to the structure of interest. This, in turn, minimizes the total acquisition time necessary to conduct the time consuming ultrastructural scanning electron microscope imaging while eliminating the risk to miss parts of the target structure. We illustrate the value of this workflow for targeting virus compartments, which are formed in HIV‐pulsed mature human dendritic cells.  相似文献   

14.
This paper presents a new automated method for analyzing compression wood fibers in fluorescence microscopy. Abnormal wood known as compression wood is present in almost every softwood tree harvested. Compression wood fibers show a different cell wall morphology and chemistry compared to normal wood fibers, and their mechanical and physical characteristics are considered detrimental for both construction wood and pulp and paper purposes. Currently there is the need for improved methodologies for characterization of lignin distribution in wood cell walls, such as from compression wood fibers, that will allow for a better understanding of fiber mechanical properties. Traditionally, analysis of fluorescence microscopy images of fiber cross-sections has been done manually, which is time consuming and subjective. Here, we present an automatic method, using digital image analysis, that detects and delineates softwood fibers in fluorescence microscopy images, dividing them into cell lumen, normal and highly lignified areas. It also quantifies the different areas, as well as measures cell wall thickness. The method is evaluated by comparing the automatic with a manual delineation. While the boundaries between the various fiber wall regions are detected using the automatic method with precision similar to inter and intra expert variability, the position of the boundary between lumen and the cell wall has a systematic shift that can be corrected. Our method allows for transverse structural characterization of compression wood fibers, which may allow for improved understanding of the micro-mechanical modeling of wood and pulp fibers.  相似文献   

15.
Cutting-edge biophysical technologies including total internal reflection fluorescence microscopy, single molecule fluorescence, single channel opening events, fluorescence resonance energy transfer, high-speed exposures, two-photon imaging, fluorescence lifetime imaging, and other tools are becoming increasingly important in immunology as they link molecular events to cellular physiology, a key goal of modern immunology. The primary concern in all forms of microscopy is the generation of contrast; for fluorescence microscopy contrast can be thought of as the difference in intensity between the cell and background, the signal-to-noise ratio. High information-content images can be formed by enhancing the signal, suppressing the noise, or both. As improved tools, such as ICCD and EMCCD cameras, become available for fluorescence imaging in molecular and cellular immunology, it is important to optimize other aspects of the imaging system. Numerous practical strategies to enhance fluorescence microscopy experiments are reviewed. The use of instrumentation such as light traps, cameras, objectives, improved fluorescent labels, and image filtration routines applicable to low light level experiments are discussed. New methodologies providing resolution well beyond that given by the Rayleigh criterion are outlined. Ongoing and future developments in fluorescence microscopy instrumentation and technique are reviewed. This review is intended to address situations where the signal is weak, which is important for emerging techniques stressing super-resolution or live cell dynamics, but is less important for conventional applications such as indirect immunofluorescence. This review provides a broad integrative discussion of fluorescence microscopy with selected applications in immunology.  相似文献   

16.
We have built a fibre optic confocal reflectance microscope capable of imaging biological tissue in near real time. The measured lateral resolution is 3 µm and axial resolution is 6 µm. Images of epithelial cells, excised tissue biopsies, and the human lip in vivo have been obtained at 15 frames s?1. Both cell morphology and tissue architecture can be appreciated from images obtained with this microscope. This device has the potential to enable reflected light confocal imaging of internal organs for in situ detection of pathology.  相似文献   

17.
Two‐photon fluorescence microscopy, in combination with tetracycline labelling, was used to observe the remineralising potentials of a calcium silicate‐based restorative material (BiodentineTM) and a glass ionomer cement (GIC:?Fuji?IX) on totally demineralised dentine. Forty demineralised dentine discs were stored with either cement in three different solutions: phosphate buffered saline (PBS) with tetracycline, phosphate‐free tetracycline, and tetracycline‐free PBS. Additional samples of demineralised dentine were stored alone in the first solution. After 8‐week storage at 37 °C, dentine samples were imaged using two‐photon fluorescence microscopy and Raman spectroscopy. Samples were later embedded in PMMA and polished block surfaces studied by 20 kV BSE imaging in an SEM to study variations in mineral concentration. The highest fluorescence intensity was exhibited by the dentine stored with BiodentineTM in the PBS/tetracycline solution. These samples also showed microscopic features of matrix remineralisation including a mineralisation front and intra‐ and intertubular mineralisation. In the other solutions, dentine exhibited much weaker fluorescence with none of these features detectable. Raman spectra confirmed the formation of calcium phosphate mineral with Raman peaks similar to apatite, while no mineral formation was detected in the dentine stored in cement‐free or PBS‐free media, or with GIC. It could therefore be concluded that BiodentineTM induced calcium phosphate mineral formation within the dentine matrix when stored in phosphate‐rich media, which was selectively detectable using the tetracycline labelling.  相似文献   

18.
Integrated array tomography combines fluorescence and electron imaging of ultrathin sections in one microscope, and enables accurate high‐resolution correlation of fluorescent proteins to cell organelles and membranes. Large numbers of serial sections can be imaged sequentially to produce aligned volumes from both imaging modalities, thus producing enormous amounts of data that must be handled and processed using novel techniques. Here, we present a scheme for automated detection of fluorescent cells within thin resin sections, which could then be used to drive automated electron image acquisition from target regions via ‘smart tracking’. The aim of this work is to aid in optimization of the data acquisition process through automation, freeing the operator to work on other tasks and speeding up the process, while reducing data rates by only acquiring images from regions of interest. This new method is shown to be robust against noise and able to deal with regions of low fluorescence.  相似文献   

19.
We have employed field-emission secondary electron microscopy (FESEM) for morphological evaluation of freeze-fractured frozen-hydrated renal epithelial LLC-PK1 cells prepared with our simple cryogenic sandwich-fracture method that does not require any high-vacuum freeze-fracture instrumentation (Chandra et al. (1986) J. Microsc. 144 , 15–37). The cells fractured on the substrate side of the sandwich were matched one-to-one with their corresponding complementary fractured faces on the other side of the sandwich. The FESEM analysis of the frozen-hydrated cells revealed three types of fracture: (i) apical membrane fracture that produces groups of cells together on the substrate fractured at the ectoplasmic face of the plasma membrane; (ii) basal membrane fracture that produces basal plasma membrane-halves on the substrate; and (iii) cross-fracture that passes randomly through the cells. The ectoplasmic face (E-face) and protoplasmic face (P-face) of the membrane were recognized based on the density of intramembranous particles. Feasibility of fractured cells was shown for intracellular ion localization with ion microscopy, and fluorescence imaging with laser scanning confocal microscopy. Ion microscopy imaging of freeze-dried cells fractured at the apical membrane revealed well-preserved intracellular ionic composition of even the most diffusible ions (total concentrations of K+, Na+ and Ca+). Structurally damaged cells revealed lower K+ and higher Na+ and Ca+ contents than in well-preserved cells. Frozen-freeze-dried cells also allowed imaging of fluorescently labelled mitochondria with a laser scanning confocal microscope. Since these cells are prepared without washing away the nutrient medium or using any chemical pretreatment to affect their native chemical and structural makeup, the characterization of fracture faces introduces ideal sample types for chemical and morphological studies with ion and electron microscopes and other techniques such as laser scanning confocal microscopy, atomic force microscopy and near-field scanning optical microscopy.  相似文献   

20.
Measurements of the transport of circulating sulphorhodamine B-labelled albumin into the arterial wall, made by applying digital imaging fluorescence microscopy to sections of arteries fixed in situ , are limited in sensitivity by the low levels of tracer fluorescence and high levels of autofluorescence emitted from the tissue. Three attempts to improve these ratios are described. In the first, spectra of the tracer in solution and of arterial autofluorescence were used to design novel microscope filters for rhodamine-like dyes. By exciting with the rarely used yellow lines of the mercury arc lamp and detecting a narrow band of emission with Stokes shifts as small as 15 nm, the ratio of tracer fluorescence to autofluorescence was tripled. In the second, effects of different fixatives were investigated. Using a model system, it was confirmed that Karnovsky's fixative gives good tracer immobilization but elevates autofluorescence, whereas fixative-free buffer solutions give low autofluorescence but do not retain the tracer. It was further found that simple formaldehyde-based fixatives, hitherto considered to be poor fixatives of albumin, immobilized the tracer as well as the glutaraldehyde-based fixative, whilst giving autofluorescence levels comparable to those seen with buffer alone; they therefore give excellent tracer fluorescence to autofluorescence ratios. In the third, lowering specimen temperature by 50 °C was found to increase the intensity of tracer fluorescence by 30% whilst autofluorescence was unaffected. These data may have relevance to microscopical studies using other tissues and fluorescent tracers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号