首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 156 毫秒
1.
BAF/UF/RO联合工艺深度处理印染废水中试   总被引:5,自引:1,他引:5  
采用中试规模(5m^3/d)的曝气生物滤池/超滤/反渗透联合工艺对棉印染废水二级生化处理出水进行了深度处理。试验结果表明:当进水COD、色度、浊度、电导率分别为308—509mg/L、128—220倍、56—158NTU、5360—6580DS/cm时,相应的出水指标分别为10~20mg/L、〈2倍、〈0.5NTU、48—59DS/cm,该水质可满足印染工艺的要求。  相似文献   

2.
UASB/水解酸化/曝气生物滤池处理高浓度聚酯废水   总被引:3,自引:0,他引:3  
介绍了UASB/水解酸化/曝气生物滤池工艺在聚酯废水处理中的应用,并进行了工艺参数的选择和运行效果的分析。结果证明,当进水COD、BOD5浓度分别为(1—1.2)×10^4mg/L和3450—4200mg/L时,处理出水COD≤150mg/L,BOD5≤30mg/L,能够达到《污水综合排放标准》(GB8978--1996)的二级排放标准。  相似文献   

3.
在工艺调控的基础上,发现限氧曝气、连续流A/O工艺在长污泥龄条件下融合外排厌氧富磷上清液的侧流除磷技术可以解决污泥减量工艺对氮、磷去除能力低的问题,以此为基础开发了具有脱氮除磷功能的污泥减量LSP&PNR工艺。应用该工艺处理校园生活污水的试验结果表明,在SRT=50d、DO=0.5~1.5mg/L以及进水COD=332~420mg/L、NH,-N=30~40mg/L、TN=34~51mg/L、TP=6~9mg/L的条件下,出水COD≤23mg/L、NH3-N≤3.2mg/L、TN≤17mg/L、TP≤0.72mg/L;表观污泥产率为0.155gMLSS/gCOD。研究还发现,在LSP&PNR工艺中同步硝化反硝化是最主要的脱氮形式,约占反硝化脱氮总量的60%;代谢BOD,的需氧量为1.38~1.57kgO2/kgBOD5;进入化学除磷池的侧流液量相当于处理水量的10%~15%。  相似文献   

4.
采用分段进水生物脱氮工艺处理小区生活污水,考察了在低DO条件下,不同曝气方式对硝化率及污泥沉降性能的影响。结果表明,在曝气量为0.27m^3/h、MLSS平均为2700mg/L左右、好氧区的DO为0.26~2.5mg/L的条件下,当进水氨氮为44~55mg/L时,对氨氮的去除率保持在95%以上,对COD的去除率〉90%;当控制好氧区第1、2格室的DO分别为0.5~0.7和1.0~1.2mg/L时,系统的硝化率维持在90%以上,出水中的氨氮〈2mg/L;在恒定曝气量下,向进水中投加有机碳源,当水质改变较快时,容易引起丝状菌污泥膨胀,但通过恒DO曝气控制,可使污泥的沉降性能得到改善。  相似文献   

5.
低压射流曝气氧化沟工艺处理制浆造纸中段废水   总被引:1,自引:0,他引:1  
采用供气式低压射流曝气系统改良型氧化沟工艺处理制浆造纸中段废水,对整个调试运行过程进行了介绍。实际运行结果表明,该工艺设计合理,运行稳定可靠,出水COD≤150mg/L、SS≤80mg/L、BOD5≤80mg/L,去除率均大于85%,出水水质达到了《造纸工业水污染物排放标准》(GB3544-2001)。  相似文献   

6.
采用水解酸化与深井曝气为主体的组合工艺处理激素类制药废水,处理规模为3 000 m3/d。工程运行结果表明:当进水COD为8 000~10 000 mg/L、BOD5为4 800~6 000 mg/L、pH值为4~6、氨氮约为300 mg/L时,处理后出水COD≤500 mg/L,BOD5≤300 mg/L,出水水质达到《污水综合排放标准》(GB 8978—1996)的三级标准。  相似文献   

7.
杨健  杨嬗  吴敏 《中国给水排水》2003,19(Z1):117-119
酒精废水经厌氧生物处理后排出的消化液COD浓度约为6 500 mg/L,BOD5/COD值较低,为此采用好氧生化-铁屑微电解混凝工艺进行了后续处理.结果表明,当好氧生物反应器容积负荷为0.65 kgCOD/(m3*d)、铁屑微电解反应与曝气时间各为1 h、聚铝(PAC)投量为300 mg/L、PAM投量为4 mg/L时,该组合工艺出水COD为156~236 mg/L、BOD5为53.1~82.0 mg/L、SS为12.5~16.10 mg/L、色度为25倍,符合GB 8978-1996的二级排放标准.  相似文献   

8.
—体化间歇曝气多级生物膜反应器处理低温、低浓污水   总被引:1,自引:0,他引:1  
采用新型一体化间歇曝气多级生物膜反应器处理低浓度小城镇污水,重点考察了冬季低温(5~8℃)对反应器处理效能的影响,以及采用分级间歇曝气方式能否解决连续流生物膜反应器除磷效能低的问题。试验结果表明:在水温为5~8℃、有机负荷为0.5kgCOD/(m^3·d)、氮负荷为0.12kgN/(m^3·d)、DO为6.0mg/L、HRT为6.0h、挂膜密度为30%,以及第一、二级生物膜反应区的停曝与曝气时间比均为1.0h/2.0h的条件下,处理平均COD为120mg/L、TN为30mg/L、NH4^+-N为27mg/L、PO4^3--P为1.9mg/L的低浓度城镇污水,可使出水COD≤35mg/L,NH4^+-N≤3.3mg/L,TN≤19mg/L,PO4^3--P≤0.8mg/L,达到了《城镇污水处理厂污染物排放标准》(GB 18918-2002)的一级B标准。  相似文献   

9.
混凝/化学氧化/曝气生物滤池深度处理垃圾渗滤液   总被引:8,自引:4,他引:4  
随着垃圾渗滤液的老龄化,常规的生化处理已经不能使出水达标排放,需要进行深度处理。采用混凝/化学氧化/曝气生物滤池联合工艺深度处理垃圾渗滤液,进水COD为700mg/L左右,出水COD〈100mg/L,去除率〉85%,排放口水质达到《生活垃圾填埋污染控制标准》(GB16889--1997)一级标准。  相似文献   

10.
粉末炭/SBR工艺处理高浓豆制品废水研究   总被引:3,自引:0,他引:3  
对粉末炭(PAC)/SBR工艺处理高浓度豆制品生产废水进行了研究,探讨了PAC用量、曝气时间、曝气方式对处理效果的影响.结果表明:在PAC用量为400 mg/L、PAC/SBR反应器进水COD负荷<6 000 mg/L及限制曝气时间为6h时,最终出水的COD和NH 4-N浓度均能达标.COD由2850 mg/L降至611mg/L时,反应符合零级反应动力学规律;COD<611 mg/L时,反应符合一级反应动力学规律.  相似文献   

11.
传统膜生物反应器(MBR)的能耗较大、运行费用较高,为此开发了射流曝气MBR工艺。采用其处理某开发区污水,在进水COD为60~300 mg/L、氨氮为3~30 mg/L、总磷为0.8~5 mg/L、水力停留时间为2 h的条件下,出水COD、氨氮、总磷的平均值分别为25、1.27、1.66 mg/L,平均去除率分别为84%、93%、46%。反应器采用射流曝气方式,提高了氧的转移效率,大幅降低了能耗,与常规MBR相比则节能达70%。近一年的运行表明,射流曝气对膜丝的正常工作没有任何影响,其清洗周期保持不变。  相似文献   

12.
Tan TW  Ng HY 《Water research》2008,42(4-5):1122-1132
The conflicting influence of mixed liquor recycle ratio and dissolved oxygen on nitrogen removal and membrane fouling of a pre-denitrification submerged MBR was investigated in this study. It was found that a high aeration rate of 10 L air/min was able to minimize membrane fouling as compared with lower aeration rates of 5 and 2.5L air/min in this study. Faster fouling at lower aeration rate was due to the decrease in cross-flow velocity across the membrane surface. However, high DO concentration (average of 5.1+/-0.5mg O2/L) present in the recycle mixed liquor at an aeration rate of 10 L air/min deteriorated the TN removal efficiency when operating at a recycle ratio of more than 3. A lower aeration rate of 5L air/min, resulting in an average DO concentration of 3.4+/-0.7 mg O2/L in the recycle mixed liquor, led to an improvement in TN removal efficiency: 63%, 80%, 84% and 89% for mixed liquor recycle ratio of 1, 3, 5 and 10, respectively. Further decrease in aeration rate to 2.5L air/min, resulting in an average DO concentration of 1.9+/-0.8 mg O2/L, did not improve the TN removal efficiency. Using a newly developed simplified nitrification-denitrification model, it was calculated that the COD/NO3(-)-N required for denitrification at 10 L air/min aeration rate was higher than those associated with 5 and 2.5L air/min aeration rates. The model also revealed that denitrification at an aeration rate of 10 L air/min was limited by COD concentration present in the wastewater when operating at a mixed liquor recycle ratio of 3 and higher.  相似文献   

13.
龚安军  刘氚 《山西建筑》2011,37(15):106-108
采用CASS工艺对低碳氮比生活污水进行处理研究,试验结果表明:通过外加甲醇将碳氮比调整到5∶1,排水比50%,混合液回流比100%的情况下,最佳运行工况为充水曝气6 h,沉淀1 h,滗水0.5 h,静置0.5 h,在进水COD为210 mg/L-375 mg/L,TN为52 mg/L-62 mg/L,TP为1.9 mg/L-2.9 mg/L,SS为100 mg/L-202 mg/L的情况下,出水COD为5 mg/L-50 mg/L,TN为10 mg/L-21 mg/L,TP为0.5 mg/L-1.2 mg/L,SS为6 mg/L-19 mg/L,出水各项指标稳定且达到排放标准。  相似文献   

14.
间歇曝气折流BAF处理小城镇生活污水的效能研究   总被引:1,自引:1,他引:0  
在间歇曝气运行方式下对折流曝气生物滤池(BBAF)处理小城镇生活污水的效能进行了研究,考察了曝气/停曝时间对处理效果的影响.结果表明,在气水比为8:1、曝气/停曝时间分别为1.5 h/1 h和1.25 h/1.25 h的条件下,当进水COD为53~275 mg/L、TN为16.83~47.68 mg/L、TP为1.58~3.75 mg/L时,出水水质均能满足<城镇污水处理厂污染物排放标准>(GB 18918--2002)的一级B标准.曝气/停曝时间为1.25 h/1.25 h相对节能,可作为今后运行的主要工况.  相似文献   

15.
曝气/微生物/人工湿地组合工艺处理黑臭河水   总被引:2,自引:0,他引:2  
针对河北省东部某黑臭河流治理项目,开展了曝气/微生物/人工湿地组合工艺处理黑臭河水的中试研究.经过2个月的运行,在进水污染物浓度高且水质波动大的情况下,系统仍运行效果良好,COD、NH3-N、TP分别从519、11.5、6.5 mg/L左右下降到33、1.5、0.25 mg/L,出水水质达到了<地表水环境质量标准>中的V类水质标准.  相似文献   

16.
以微碳非限量曝气SBR法处理港口有机散化洗舱废水,稳定有效。进水COD浓度3000mg/L,出水〈200mg/L,COD去除率90%以上。工艺运行周期12h(其中进水3h,曝气8h,沉淀2h,排水及闲置各1h)。还对有机物降解去除规律进行了分析探讨。  相似文献   

17.
CAST工艺处理城市污水的强化脱氮研究   总被引:8,自引:4,他引:8  
介绍了镇江征润州污水处理厂CAST工艺的运行情况,结合该厂实际运行状况开展了强化脱氮效果的生产性试验研究。结果表明,该工艺对COD、SS和TP的去除率均能维持在80%以上,但对氨氮的去除效果较差;在该厂运行模式下,控制进水/曝气前30min的DO〈0.5mg/L、进水/曝气后30min的DO浓度在1.0-3.0mg/L、纯曝气DO浓度在2.0-3.0mg/L,可以实现同步硝化反硝化和硝化/反硝化作用下的共同脱氮,使脱氮效率提高了57%左右;在控制进水/曝气后DO〈0.5mg/L、纯曝气DO浓度在1.0-3.0mg/L的条件下,可以实现同步硝化反硝化作用下的脱氮,但较难实现理想的脱氮效果。  相似文献   

18.
Fe-H2O2深度处理造纸中段废水的研究   总被引:1,自引:0,他引:1  
为解决零价铁法处理废水时效率偏低的问题,采用Fe-H2O2法对造纸中段废水的二级处理出水进行了深度处理,分别考察了pH值、反应时间、铁炭比、曝气量和H2O2投量对色度和COD去除率的影响.结果表明:在pH值为3.5、铁炭比(体积比)为1.2、曝气量为1.4 L/min、铁屑粒径为60~80目、H2O2投量为40~60 mg/L的最优条件下,当处理时间控制在35 min时,对色度和COD的去除率可分别达到98%和77%左右,出水可回用.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏