首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9‐year‐old children from the PARIS birth cohort. BC and UFP were continuously measured by portable devices (microAeth® AE51 and DiSCmini®) for a minimum of 24 hours, while participating families simultaneously filled in a space‐time‐activities‐budget questionnaire. BC exposure concentration was higher during trips (principally metro/train and bus), while UFP exposure concentration was higher during indoor activities (mainly eating at restaurants) and in trips. The most important UFP peaks were measured at home, especially during cooking. Home and school together accounted for much of the total exposure, 83.8% for BC and 85.3% for UFP. The contribution of transport to total exposure was 12.4% for BC and 9.7% for UFP, while extracurricular activities were responsible for 3.8% and 5% of the total exposure to BC and UFP, respectively.  相似文献   

2.
Taxi drivers’ exposure to traffic-related air pollutants inside their vehicles has been reported in different countries but not yet in Lebanon. Thus, we conducted a cross-sectional study on 20 Lebanese taxi drivers to (1) assess their exposure to ultrafine particles (UFP) and black carbon (BC) inside their vehicles and (2) identify determinants of this exposure. UFP and BC were measured using Diffusion Size Classifier Miniature® and microAeth ® Model AE51, respectively, for 5 hours. Data on characteristics of vehicles and trips were collected by face-to-face interviews. Associations between pollutant levels and their determinants were analyzed by multiple linear regression. The mean of UFP count (35.2 ± 17.6 x 103 particles cm-3) and BC (5.2 ± 1.9 μg m-3) concentrations in-taxis was higher in the morning measurements compared with those in the afternoon measurements. UFP count increased in-taxis by 60% for every 10 minutes spent in blocked traffic and by 84% starting from two trips with smokers compared to trips without smokers. Conversely, UFP count decreased by 30% for every 10 minutes under both air-conditioning and air recirculation mode with windows closed. BC was not affected by any of these factors. Our findings suggest easy ways to reduce UFP exposure inside vehicles for all commuters.  相似文献   

3.
This study presents real-time concentrations of traffic-related air pollutants during 499 trips conducted by 50 Parisian taxi drivers from PUF-TAXI project. Ultrafine particles (UFP), black carbon (BC), and nitrogen dioxide (NO2)/carbon monoxide (CO) were measured inside vehicles by Diffusion Size Classifier Miniature®, microAeth®, and Gas-Pro®, respectively, for nine hours. Vehicle/trip data characteristics were collected by questionnaires and on ambient conditions by monitoring stations. The associations between pollutant levels and their potential determinants were analyzed using generalized estimating equation model. Determinants of in-vehicle pollutants levels were identified: (1) ambient factors (meteorology and ambient pollution)—affecting BC, NO2, and CO; (2) vehicle characteristics—affecting all pollutants; and (3) trip-related driving habits—affecting UFP, BC, and CO. We highlight that commuters can, therefore, avoid high in-vehicle air pollutant concentrations mainly by (1) closing windows and activating air-conditioning under air recirculation mode in congested traffic; (2) smooth driving; and (3) maintaining cabin air filters.  相似文献   

4.
Burning candles release a variety of pollutants to indoor air, some of which are of concern for human health. We studied emissions of particles and gases from the stressed burning of five types of pillar candles with different wax and wick compositions. The stressed burning was introduced by controlled fluctuating air velocities in a 21.6 m3 laboratory chamber. The aerosol physicochemical properties were measured both in well-mixed chamber air and directly above the candle flame with online and offline techniques. All candles showed different emission profiles over time with high repeatability among replicates. The particle mass emissions from stressed burning for all candle types were dominated by soot (black carbon; BC). The wax and wick composition strongly influenced emissions of BC, PM2.5, and particle-phase polycyclic aromatic hydrocarbons (PAHs), and to lower degree ultrafine particles, inorganic and organic carbon fraction of PM, but did not influence NOx, formaldehyde, and gas-phase PAHs. Measurements directly above the flame showed empirical evidence of short-lived strong emission peaks of soot particles. The results show the importance of including the entire burn time of candles in exposure assessments, as their emissions can vary strongly over time. Preventing stressed burning of candles can reduce exposure to pollutants in indoor air.  相似文献   

5.
The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5‐year‐old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82 × 104 and 1.32 × 104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15 × 104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17 × 104, 3.28 × 104, and 4.09 × 104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31 × 103, 11.3 × 103, and 7.14 × 103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5‐year‐old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules.  相似文献   

6.
Emissions from candles are of concern for indoor air quality. In this work, five different types of pillar candles were burned under steady burn conditions in a new laboratory scale system for repeatable and controlled comparison of candle emissions (temperature ~25°C, relative humidity ~13%, O2 >18%, air exchange rate 1.9 h−1). Burn rate, particle number concentrations, mass concentrations, and mode diameters varied between candle types. Based on the results, the burning period was divided in two phases: initial (0–1 h) and stable (1–6 h). Burn rates were in the range 4.4–7.3 and 4.7–7.1 g/h during initial and stable phase, respectively. Relative particle number emissions, mode diameters, and mass concentrations were higher during the initial phase compared to the stable phase for a majority of the candles. We hypothesize that this is due to elevated emissions of wick additives upon ignition of the candle together with a slightly higher burn rate in the initial phase. Experiments at higher relative humidity (~40%) gave similar results with a tendency toward larger particle sizes at the higher relative humidity. Chemical composition with respect to inorganic salts was similar in the emitted particles (dry conditions) compared to the candlewicks, but with variations between different candles.  相似文献   

7.
Traffic‐related air pollution (TRAP) exposure during childhood is associated with asthma; however, the contribution of the different TRAP pollutants in each microenvironment (home, school, transportation, others) in asthmatic and non‐asthmatic children is unknown. Daily (24‐h) personal black carbon (BC), ultrafine particle (UFP), and alveolar lung‐deposited surface area (LDSA) individual exposure measurements were obtained from 100 children (29 past and 21 current asthmatics, 50 non‐asthmatics) aged 9±0.7 years from the INMA‐Sabadell cohort (Catalonia, Spain). Time spent in each microenvironment was derived by the geolocation provided by the smartphone and a new spatiotemporal map‐matching algorithm. Asthmatics and non‐asthmatics spent the same amount of time at home (60% and 61%, respectively), at school (20% and 23%), on transportation (8% and 7%), and in other microenvironments (7% and 5%). The highest concentrations of all TRAPs were attributed to transportation. No differences in TRAP concentrations were found overall or by type of microenvironment between asthmatics and non‐asthmatics, nor when considering past and current asthmatics, separately. In conclusion, asthmatic and non‐asthmatic children had a similar time‐activity pattern and similar average exposures to BC, UFP, and LDSA concentrations. This suggests that interventions should be tailored to general population, rather than to subgroups defined by disease.  相似文献   

8.
This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I‐80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir‐fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year‐round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM2.5 by 97‐98% relative to outdoors. Supply filtration systems used little energy but provided no benefits for indoor‐generated particles. Systems with MERV13‐16 filter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM2.5 by 93‐98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM2.5. Indoor ozone was 3‐4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM2.5 by 25‐75% when operated over the hour following cooking. The energy for year‐round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year.  相似文献   

9.
Airborne ultrafine particles (UFP) have been related to adverse health effects, but exposure in vulnerable population groups such as children is still not well understood. We aim to review the scientific literature regarding personal exposure to UFP in different microenvironments in populations until 18 years of age. The bibliographical search was carried out in July 2019 using the online database PubMed and was completed with references in articles found in the search. We selected the studies that used continuous counters and measured UFP levels in both specific microenvironment (houses, schools, transport, etc) and personal exposure. Finally, 32 studies fulfilled the criteria: of these, 10 analyzed personal exposure and 22 examined UFP levels in the microenvironment (especially in schools or nurseries (18/22)) and five in various microenvironments (including dwellings and means of transport, where exposure levels were higher). The characteristics of the microenvironments with the greatest levels of UFP were being close to heavy traffic or near cooking and cleaning activities. This review revealed the wide differences in exposure assessment methodologies that could lead to a lack of uniform and comparable information about the real UFP exposure in children.  相似文献   

10.
The ability to inexpensively monitor PM2.5 to identify sources and enable controls would advance residential indoor air quality (IAQ) management. Consumer IAQ monitors incorporating low‐cost optical particle sensors and connections with smart home platforms could provide this service if they reliably detect PM2.5 in homes. In this study, particles from typical residential sources were generated in a 120 m3 laboratory and time‐concentration profiles were measured with 7 consumer monitors (2‐3 units each), 2 research monitors (Thermo pDR‐1500, MetOne BT‐645), a Grimm Mini Wide‐Range Aerosol Spectrometer (GRM), and a Tapered Element Oscillating Microbalance with Filter Dynamic Measurement System (FDMS), a Federal Equivalent Method for PM2.5. Sources included recreational combustion (candles, cigarettes, incense), cooking activities, an unfiltered ultrasonic humidifier, and dust. FDMS measurements, filter samples, and known densities were used to adjust the GRM to obtain time‐resolved mass concentrations. Data from the research monitors and 4 of the consumer monitors—AirBeam, AirVisual, Foobot, Purple Air—were time correlated and within a factor of 2 of the estimated mass concentrations for most sources. All 7 of the consumer and both research monitors substantially under‐reported or missed events for which the emitted mass was comprised of particles smaller than 0.3 μm diameter.  相似文献   

11.
研究了炭黑碳纤维复相导电混凝土的导电性能,分析了导电混凝土的电阻率变化,为实际应用于道路融雪化冰提供理论依据与试验依据。利用纳米导电炭黑和碳纤维作为导电相来改善混凝土的导电性能,进行炭黑碳纤维复相导电混凝土的导电性能试验,分析环境温度、干湿度和外加电压对炭黑碳纤维导电混凝土电阻率的影响。导电混凝土的电阻率受温度、湿度和外加电压的影响,当环境条件发生变化时,导电混凝土的导电性能也会发生变化。炭黑碳纤维复相导电混凝土的电阻率随着温度的升高出现一定程度的减小;干燥状态下的电阻率高于潮湿状态下的电阻率;电阻率随着外加电压的增大有一定程度的减小,当电压达到一定数值时,电阻率趋于稳定。  相似文献   

12.
在分析现有火灾探测器的探测原理、火灾发展过程及其产物的基础上,提出基于火灾产物炭黑粒子的一种感烟探测器的设想,为火灾探测器的研究提出了新的思路和方向。  相似文献   

13.
We present the first results of a source apportionment for the urban aerosol in Erfurt, Germany, for the period 1995-1998. The analysis is based on data of particle number concentrations (0.01-2.5 microm; mean 1.8 x 10(4) cm(-3), continuous), the concentration of the ambient gases SO(2), NO, NO(2) and CO (continuous), particle mass less than 2.5 microm (PM(2.5)) and less than 10 microm (PM(10)) (Harvard Impactor sampling, mean PM(2.5) 26.3 micro/m(3), mean PM(10) 38.2 microg/m(3)) and the size fractionated concentrations of 19 elements (impactor sampling 0.05-1.62 microm, PIXE analysis). We determined: (a) the correlations between (i) the 1- and 24-h average concentrations of the gaseous pollutants and the particle number as well as the particle mass concentration and (ii) between the 24-h elemental concentrations; (b) Crustal Enrichment Factors for the PIXE elements using Si as reference element; and (c) the diurnal pattern of the measured pollutants on weekdays and on weekends. The highly correlated PIXE elements Si, Al, Ti and Ca having low enrichment factors were identified as soil elements. The strong correlation of particle number concentrations with NO, which is considered to be typically emitted by traffic, and the striking similarity of their diurnal variation suggest that a sizable fraction of the particle number concentration is associated with emission from vehicles. Besides NO and particle number concentrations other pollutants such as NO(2), CO as well as the elements Zn and Cu were strongly correlated and appear to reflect motor vehicle traffic. Sulfur could be a tracer for coal combustion, however, it was not correlated with any of the quoted elements. Highly correlated elements V and Ni have similar enrichment factors and are considered as tracers for oil combustion.  相似文献   

14.
At city level, personal monitoring is the best way to assess people's exposure. However, it is usually estimated from a few monitoring stations. Our aim was to determine the exposure to black carbon (BC) and BC dose for 45 schoolchildren with portable microaethalometers and to evaluate the relationship between personal monitoring and fixed stations at schools (indoor and outdoor) and in an urban background (UB) site. Personal BC concentra‐tions were 20% higher than in fixed stations at schools. Linear mixed‐effect models showed low R2 between personal measurements and fixed stations at schools (R2 ≤ 0.28), increasing to R2 ≥ 0.70 if considering only periods when children were at schools. For the UB station, the respective R2 were 0.18 and 0.45, indicating the importance of the distance to the monitoring station when assessing exposure. During the warm season, the fixed stations agreed better with personal measurements than during the cold one. Children spent 6% of their time on commuting but received 20% of their daily BC dose, due to co‐occurrence with road traffic rush hours and the close proximity to the source. Children received 37% of their daily‐integrated BC dose at school. Indoor environments (classroom and home) were responsible for the 56% BC dose.  相似文献   

15.
王铁宝  陈淼  张国强 《山西建筑》2007,33(7):170-171
根据白炭黑的特点,提出在SBS改性沥青中复配加入白炭黑的方法,并通过试验研究探讨了白炭黑对SBS改性沥青常规性能和储存稳定性的影响,试图使SBS改性沥青的性能在基本不受影响的前提下,得到高温储存稳定性良好的改性沥青,从而延长SBS改性沥青在路面中的使用寿命。  相似文献   

16.
Estimating personal exposure to air pollution is a crucial component in identifying high-risk populations and situations. It will enable policy makers to determine efficient control strategies. Cycling is again becoming a favorite mode of transport both in developing and in developed countries due to increasing traffic congestion and environmental concerns. In Europe, it is also seen as a healthy sports activity. However, due to high levels of hazardous pollutants in the present day road microenvironment the cyclist might be at a higher health risk due to higher breathing rate and proximity to the vehicular exhaust.In this paper we present estimates of the exposure of a cyclist to particles of various size fractions including ultrafine particles (UFP) in the town of Mol (Flanders, Belgium). The results indicate relatively higher UFP concentration exposure during morning office hours and moderate UFP levels during afternoon. The major sources of UFP and PM10 were identified, which are vehicular emission and construction activities, respectively. We also present a dust mapping technique which can be a useful tool for town planners and local policy makers.  相似文献   

17.
A six‐month winter‐spring study was conducted in a suburb of the northern European city of Kuopio, Finland, to identify and quantify factors determining daily personal exposure and home indoor levels of fine particulate matter (PM2.5, diameter <2.5 µm) and its light absorption coefficient (PM2.5abs), a proxy for combustion‐derived black carbon. Moreover, determinants of home indoor ozone (O3) concentration were examined. Local central site outdoor, home indoor, and personal daily levels of pollutants were monitored in this suburb among 37 elderly residents. Outdoor concentrations of the pollutants were significant determinants of their levels in home indoor air and personal exposures. Natural ventilation in the detached and row houses increased personal exposure to PM2.5, but not to PM2.5abs, when compared with mechanical ventilation. Only cooking out of the recorded household activities increased indoor PM2.5. The use of a wood stove room heater or wood‐fired sauna stove was associated with elevated concentrations of personal PM2.5 and PM2.5abs, and indoor PM2.5abs. Candle burning increased daily indoor and personal PM2.5abs, and it was also a determinant of indoor ozone level. In conclusion, relatively short‐lasting wood and candle burning of a few hours increased residents’ daily exposure to potentially hazardous, combustion‐derived carbonaceous particulate matter.  相似文献   

18.
Singapore is a tropical country with a high density of day-care facilities whose indoor environments may be adversely affected by outdoor fine particle (PM2.5) air pollution. To reduce this problem requires effective, evidence-based exposure-reduction strategies. Little information is available on the penetration of outdoor PM2.5 into day-care environments. Our study attempted to address the following objectives: to measure indoor infiltration factor (Finf) of PM2.5 from outdoor PM2.5 and to determine the building parameters that modify the indoor PM2.5. We collected indoor/outdoor 1-min PM2.5 from 50 day-care classrooms. We noted mean Finf ± SD of 0.65 ± 0.22 in day-care rooms which are naturally ventilated and lower Finf ± SD values of 0.47 ± 0.18 for those that are air-conditioned: values which are lower than those reported in Singapore residences. The air exchange rates were higher in naturally ventilated rooms (1.47 vs 0.86 h−1). However, fine particle deposition rates were lower for naturally ventilated rooms (0.67 ± 0.43 h−1) compared with air-conditioned ones (1.03 ± 0.55 h−1) presumably due to composite rates linked to the filters within the split unit air-conditioners, higher recirculation rates, and interior surfaces in the latter. Our findings indicate that children remaining indoor in daycares where air-conditioning is used can reduce their PM2.5 exposures during outdoor pollution episodes.  相似文献   

19.
Modulus is one of the main parameters during the design of asphalt pavement structure, the newest specifications of China gives the dynamic moduli ranges of commonly used asphalt mixtures with base asphalt (BA) or styrene-butadiene-styrene modified asphalt (SBS MA), while the moduli ranges of mixtures with carbon black modified asphalt (CB MA) are not recommended. To investigate the CB effect on the dynamic moduli of CB MA mixtures, one commonly used asphalt mixture (AC-20) was designed with BA, SBS MA, and CB MA, respectively. Then, the uniaxial compression dynamic modulus tests were conducted at different temperatures and loading frequencies, the master curves of asphalt mixtures were analyzed based on the time-temperature equivalence principle. The results show that with increasing loading frequency, the temperature dependence of dynamic moduli of all asphalt mixtures tend to be less obvious. Both SBS and CB can decrease the temperature sensitivity of asphalt mixture, the SBS MA mixture has the lowest temperature sensitivity, followed by CB MA and BA mixture. In addition, CB and SBS can obviously improve the dynamic modulus of the BA mixture, enhance the anti-deformation performance of pavement structure, and the improvement effect of CB is almost the same with SBS.  相似文献   

20.
Zhang Q  Zhu Y 《Indoor air》2012,22(1):33-42
This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvironments. Human activities, ventilation settings, and occupancy were recorded. The study found a greater variation of indoor particle number concentration (0.6 × 10(3) -29.3 × 10(3) #/cm(3) ) than of outdoor (1.6 × 10(3) -16.0 × 10(3) #/cm(3) ). The most important factors affecting indoor UFP levels were related to various indoor sources. Gas fan heaters increased the indoor-to-outdoor ratio (I/O ratio) of total particle number concentrations to 30.0. Food-related activities, cleaning, and painting also contributed to the increased indoor particle number concentration with I/O ratios larger than 1.0. Without indoor sources, the I/O ratios for total particles varied from 0.12 to 0.66 for the five ventilation systems studied. The I/O ratio decreased when the outdoor total particle number concentration increased. Particles with diameters <60 nm were less likely to penetrate and stay airborne in indoor environments than larger particles and were measured with smaller I/O ratios. PRACTICAL IMPLICATIONS: From an exposure assessment perspective, schools are important and little-studied microenvironments where students congregate and spend a large proportion of their active time. This study provides information for indoor and outdoor ultrafine particle concentrations at different types of school microenvironments. These data may allow future epidemiological studies to better estimate exposure and assess ultrafine particles health effects among students.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号